• 제목/요약/키워드: Formaldehyde-Resorcinol

검색결과 53건 처리시간 0.02초

In-situ 중합에 의한 향료와 항균제의 마이크로 캡슐화에 관한 연구(I) (A Study on Microencapsulation of Perfume and Antibiotics by In-situ Polymerzation(I))

  • 박차철;정영진;박찬영;민성기
    • 한국염색가공학회지
    • /
    • 제9권6호
    • /
    • pp.68-73
    • /
    • 1997
  • Urea/formaldehyde(UF) and melamine/formaldehyde(MF) microcapsules containing perfume and 2,4,4'-trichlroro-2-hydroxydiphenyl ether(DP) were prepared by the in-situ polymerization using urea and formaldehyde. Effects of dispersing agent, accelerating agent, formaldehyde, agitation speed on the mean diameter of microcapsules were investigated. The diameter of microcapsule was decreased with increasing dispersing agent concentration. A slight increase in the diameter was observed when the concentration of film forming material was increased. The diameter of microcapsule was decreased with increasing agitation speed up to 8,000rpm. The mean diameters of UF microcapsule prepared at 8,000rpm are about 3$\mu$m. A slight decrease in the diameter was observed when the concentration of resorcinol was increased.

  • PDF

Bonding Performance of Adhesives with Lamina in Structural Glulam Manufactured by High Frequency Heating System

  • Kim, Keon-Ho;Kim, Se-Jong;Yang, Sang-Yun;Yeo, Hwanmyeong;Eom, Chang-Deuk;Shim, Kugbo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.682-690
    • /
    • 2015
  • The bonding performance of two types of wood adhesives, namely phenol-resorcinol-formaldehyde (PRF) resin and melamine-urea-formaldehyde (MUF) resin for glued laminated timber manufactured by high frequency (HF) heating was evaluated. The HF heating system consists of HF oscillator with dielectric heating system for curing adhesives, and hydraulic press system for clamping glued laminated timber. The designed frequency and output power of the HF system was as 5 MHz and 60 kW, respectively. To verify dielectric heating mechanism under HF oscillation, the heat loss factors of laminae and adhesives were measured. The results show that it is possible to selectively heat adhesives for their curing due to the remarkably higher loss factor of the adhesives than those of wood laminae. The temperature of adhesive in the bonding line reached up to the set temperature within a few seconds by high frequency oscillating, which advanced the curing of adhesive afterwards. The bonding performance, such as shear strength of bonding line, water soaking delamination, and boiling water soaking delamination of PRF resin met the requirement of Korean Standard (KS), however the MUF resin did not meet the KS requirement of boiling water soaking delamination. These results indicate that the HF heating system is successful to manufacture glued laminated timbers with PRF resins to meet the bonding requirements.

메조포러스 Xerogels의 톨루엔 흡착특성

  • 손우정;김윤갑;최성우
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2006년도 학술발표회 발표논문집
    • /
    • pp.113-114
    • /
    • 2006
  • VOCs의 제어를 위하여 흡착법이 널리 사용되는데 흡착제로서 다공성 탄소가 가장 뛰어남을 보여준다. 이를 resorcinol-formaldehyde과 $Na_2CO_3$으로 졸-겔법으로 메조포러스 xerogels을 제조하고 VOCs의 대표적인 물질인 톨루엔을 흡착시켜 흡착효율을 연구한 결과 흡착효율이 뛰어남을 알 수 있었다.

  • PDF

전기이중층 캐패시터 전극용 meso-pore구조의 미소구형 활성탄소 제조 (Preparation of Micro-spherical Activated Carbon with Meso-porous Structure for the Electrode Materials of Electric Double Layer Capacitor)

  • 엄의흠;이철태
    • 공업화학
    • /
    • 제20권4호
    • /
    • pp.396-401
    • /
    • 2009
  • 전기이중층 캐패시터의 성능향상을 위한 전극물질로서 resorcinol-formaldehyde수지를 탄소원으로 사용하여 meso-pore 비율 52~64%의 기공특성을 지니며 직경 $2{\sim}10{\mu}m$의 미세구형 활성탄을 제조하였다. 이 활성탄을 전기이중층에 적용한 결과, meso-pore구조의 미세구형활성탄은 전하전달저항의 저감 및 충방전율 수용능력 향상에 효과적인 영향을 나타내어 전기이중층 캐패시터의 성능향상을 위한 효과적인 전극물질이 될 수 있음을 확인할 수 있었다.

Rate Capability of Electric Double-Layer Capacitor (EDLC) Electrodes According to Pore Length in Spherical Porous Carbons

  • Ka, Bok-H.;Yoon, Song-Hun;Oh, Seung-M.
    • 전기화학회지
    • /
    • 제10권4호
    • /
    • pp.252-256
    • /
    • 2007
  • A series of spherical porous carbons were prepared via resorcinol-formaldehyde (RF) sol-gel polymerization in the presence of cationic surfactant (CTAB, cetyltrimethylammonium bromide), wherein the carbon sphere size was controlled by varying the CTAB introduction time after a pre-determined period of addition reaction (termed as "pre-curing"). The sphere size gradually decreases with an increase in the pre-curing time within the range of 30-150 nm. The carbons possess two types of pores; one inside carbon spheres (intra-particle pores) and the other at the interstitial sites made by carbon spheres (inter-particle pores). Of the two, the surface exposed on the former was dominant to determine the electric double-layer capacitor (EDLC) performance of porous carbons. As the intra-particle pores were generated inside RF gel spheres by gasification, the pore diameter was similar for all these carbons, thereby the pore length turned out to be a decisive factor controlling the EDLC performance. The charge-discharge voltage profiles and complex capacitance analysis consistently illustrate that the smaller-sized RF carbons deliver a better rate capability, which must be the direct result of facilitated ion penetration into shorter pores.

RFL 프라이머 처리에 따른 폴리케톤 코드사와 고무 간의 계면접착성 변화에 열노화가 미치는 영향 (Effect of Thermal Aging on the Change of Interfacial Adhesion between Polyketone Cord and Rubber by RFL Primer Treatment)

  • 조하니;오우진;강송희;이승구
    • 한국염색가공학회지
    • /
    • 제30권2호
    • /
    • pp.77-89
    • /
    • 2018
  • In the case of fiber/rubber composites for tire applications, the interfacial adhesion between fiber and rubber significantly affects the physical properties of the finished products. Generally, organic synthetic fibers used for tire cords are treated with resorcinol formaldehyde latex(RFL) primer on the surface of the fiber to improve the adhesion to rubber. Changes of adhesion between rubber and tire cords might weaken as temperature rises due to overheating of car engine and friction with road. In this study, the effects of temperature on the primer treated polyketone cord/rubber composites and the changes in interfacial adhesion were investigated. Polyketone cord/rubber composites were prepared after RFL solution treatment on the surface of polyketone fibers. After that, composites was thermally aged at different temperature conditions(60, 80, 100, $120^{\circ}C$) and times(1, 5, 10, 15days). The adhesion strength of polyketone cord/rubber composite treated with RFL primer was higher than untreated composite by more than 3 times. After heat aging, the adhesion strength of untreated polyketone cord/rubber composites increased while the RFL treated polyketone cord/rubber composites decreased somewhat.

Triton X-100 존재하에 Thorin에 의한 미량의 알루미늄 이온의 분광학적 정량 및 이온-교환 분리 (Ion-exchange Separation and Spectrophotometric Determination of Trace Amount of Aluminium with Thorinin the Presence of Triton X-100)

  • 박찬일;차기원;정덕채
    • 분석과학
    • /
    • 제12권6호
    • /
    • pp.515-520
    • /
    • 1999
  • Al(III)-thorin 착물에 대한 분광학적 정량 방법을 연구하였다. pH, 리간드와 계면활성제의 농도 및 안정화 시간에 대한 최적 조건을 결정하였다. thorin 리간드는 Fe(III), Ni(II), Cu(II), Pb(II) 그리고 Co(II)를 포함한 시료용액으로부터 Al(III)을 선택적으로 분리할 수 있도록 해준다. 여러 계면활성제중에서 비이온성인 Triton X-100에서 가장 안정한 상태를 나타냈고 수용액 중에서 Al(III)-Thorin-Triton X-100 착물은 526 nm에서 최대 흡광도를 가진다. 이 방법은 혼합된 시료용액에서 Al(III)을 정량하는데 이용되었다. 그리고, 분리 및 예비농축과정은 resoreinol-fermaldehyde 수지로 채워진 컬럼을 이용하였다. 컬럼 단계에서 수지의 흡착 능력은 pH변화에 매우 민감하기 때문에 pH를 조절하는 것이 필수적이다. 분리과정은 0.2 M acetic acid-sodium acetate 완충용액 (pH 4.5)와 1.0 M $HNO_3$용액으로 이루어졌다.

  • PDF

열연화시킨 근관충전방법에 따른 근단폐쇄성에 관한 연구 (A COMPARISON OF THE APICAL SEALING ABILITY OF OBTURATION TECHNIQUES BY THERMALLY SOFTENED GUTTA PERCHA)

  • 백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.607-617
    • /
    • 1998
  • The purpose of this study was to evaluate the apical sealing ability of lateral condensation method, vertical condensation method, and MicroSeal obturation system. Sixty-four extracted anterior teeth were instrumented to #40 using Profile. Three groups of 20 teeth were obturated by lateral condensation technique, vertical condensation technique, and and MicroSeal obturation system. Control group were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were ground horizontally at 1,5mm(level 1), 2.5mm(level 2), and 3.5mm(level 3) from the anatomic apex and examined with a stereomicroscope at X40 magnification. The photographs were taken a at X40 magnification of the filling in each level and scanned. The leakage area, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was evaluated by calculating the ratio of thearea of the resin to the total area of the canal and was analyzed statistically. The results were as followed: 1. Vertical condensation group had significantly higher percentage of the area which was obturated by gutta percha than other two technique at each level. 2. At the level 1, there was the greatest leakage in the lateral condensation group, but there was no statistically significant(P>0.05) 3. At the level 2, there was the least leakage in the MicroSeal group, and the most leakage in the lateral condensation group. There was statistically significant difference between the MicroSeal group and the lateral condensation group(P<0.05). 4. At the level 3, there was least leakage in the vertical condensation group, and the most leakage in the lateral condensation group. There was statistically significant difference between the vertical condensation group and the lateral condensation group(P<0.05).

  • PDF

Hexamethoxymethylmelamine이 고무-황동피복코드간의 접착에 미치는 영향 (The Effects of Hexamethoxymethylmelamine on the Adhesion of Rubber to Brase-Plated Steel Cord)

  • 김완영;김윤섭;육경창;김형순;이정용;최상원
    • 공업화학
    • /
    • 제3권3호
    • /
    • pp.422-429
    • /
    • 1992
  • 본 연구는 고무와 황동피복 코드간의 접착력 향상을 위하여 사용되는 resorcinol formaldehyde(RF) resin과 hexamethoxymethylmelamine(HMMM)이 고무 컴파운드내에서 나타내는 morphology와 접착특성에 대하여 고찰하였다. 가황후 resin은 구형의 형태로 시편 전체에 고르게 분포되어 있었고 그의 입경은 약 $2000{\AA}$정도였다. 코드와 함께 가황시킨 시편에서 코드 주위에 존재하는 resin함량이 감소한 것으로 보아 resin이 코드쪽으로 이동이 있었던 것으로 생각된다. 또한 모듈러스는 methylene donor인 HMMM의 양이 많을수록 증가하였으며, 접착층이 더 두껍게 형성되었다. 접착력은 열 노화에 의하여 상실되며 이는 대부분 초기에 발생함을 알 수 있었다. 접착컴파운드에서 가장 유리한 RF resin과 HMMM의 비는 물성, 접착층의 안정성, 열노화특성 등을 고려할 때 1 : 0.9이었다.

  • PDF

근관충전방법에 따른 폐쇄효과의 비교 (COMPARISON OF THE SEALING ABILITY OF VARIOUS ROOT CANAL FILLING TECHNIQUES)

  • 이동경;윤수한;배광식
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.346-356
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of various canal filling methods. Palatal roots of ninety extracted human maxillary molar teeth were resected at cementoenamel junction. Eighty of them were randomly assigned to four experimental groups, ten were served as positive and negative controls. All canals were prepared to # 40 using Profile. Experimental groups were obturated by lateral condensation technique, Thermafil technique, Continuous Wave of Condensation Technique, and down-pack & back-fill technique of Obtura-II, each with root canal sealer. Control groups were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then ground horizontally at 1.5mm(level 1), 2.5mm(level 2), 3.5 mm(level 3) from the anatomical apex and examined with a stereomicroscope at ${\times}40$ magnification. The gap between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (Rank-sum test). The results were as follows : 1. At the level 1, there was the greatest leakage in the Thermafil group and Obtura-II group, and the difference between the Obtura-II group and Continuous Wave of Condensation Technique group was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the Continuous Wave of Condensation Technique group, but there was no statistically significant difference between each group (p>0.05). 3. At the level 3, there was no statistically significant difference between each group(p>0.05).

  • PDF