• 제목/요약/키워드: Formaldehyde(HCHO)

Search Result 123, Processing Time 0.027 seconds

The Assessment and Recognition on Indoor Air Quality at Schools in Korea (전국 일부 학교 건축물 내의 실내 공기 및 인식도 조사)

  • Sohn Jong-Ryeul;Yoon Seung-Uk;Kim Jong-Hyuk;Lee Yong-Sik;Choi Han-Young;Kim Young-Sung;Son Bu-Soon;Yang Won-Ho;Kim Min-Hoi
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.1-9
    • /
    • 2005
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the healthy effectsrelated to IAQ, specially in schools in Korea. Therefore, objectives of this study in this study were to measure and compare the perception of TAQ of selected air pollutants in Seoul from April to September 2004. Measurement place measured 2 schools of Seoul and local 9 schools (by Kyonggi Province, Chungchong-bukdo Chungchong-namdo, Chollado-bukdo, Cholla-namdo, Kyongsang-bukdo, Kyongsang-namdo, Kwangju, schoolin Pusan each 1 place). Temperature, humidity, illumination, carbon monoxide, carbon dioxide, TBC (total bacteria count), noise, PM10, TVOC(total volatile organic compounds), HCHO (formaldehyde) were measured simultaneously. Also, we Performed a questionnaire survey of 250 students and 50 teachers about their awareness for the importance of IAQ in their schools. Among this article, we handled noise, carbon monoxide, carbon dioxide, TBC, TVOC, HCHO, PM 10 in our conclusion. Major results were as follows ; Carbon monoxide (CO) was lower than indoor air standard of Korea. Carbon dioxide $(CO_2)$ appeared that 4 schools among our sample target school exceeded in normal standard. 4 schools were almost similar with normal standard. TBC appeared that 7 schools among 11 schools were higher than standard. Noise measured school's mean value passed exceeded standard. And school which passed over standard appeared to 7 schools among 11 schools. HCHO was exceeded 4 schools by standard that excess and certainly interrelation between school's establishment year and facilities of construction was detected. PM10 was exposed all schools by fitness in standard. TVOC appeared that 9 schools among 11 measurement school was exceeded health effect standard of Japan.

Characteristics of indoor air quality in the overground and underground railway stations (지상과 지하역사의 실내공기질 특성과 외기영향 평가)

  • Namgung, Hyeong-Kyu;Song, Ji-Han;Kim, Soo-Yeon;Kim, Hee-Man;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.17-25
    • /
    • 2016
  • In this study, the air quality of underground and overground railway stations was evaluated focusing on the degree of influence of the outside air quality. The measured components were particulate matter ($PM_{10}$), carbon dioxide ($CO_2$), carbon monoxide (CO), nitrogen dioxide ($NO_2$), formaldehyde (HCHO), ozone ($O_3$), total airborne bacteria (TAB), total volatile organic carbon (TVOC), and Radon (Rn), which are included in the maintenance standards and recommended standards of the Indoor Air Quality Management Act. Also, the indoor/outdoor concentration ratios of $PM_{10}$, $NO_2$, and $O_3$ were calculated to estimate the influence of the outdoor air quality. The concentrations of $PM_{10}$ HCHO, TVOC, $NO_2$, and Rn in the underground stations were found to be higher than those in the overground stations. These results indicate that the (present) generation of contaminants are caused by the indoor source of the underground station. The ozone concentration of the overground stations was higher than that of the underground stations, which indicates that the outdoor ozone concentration influenced that of the overground stations directly. Thus, methods of improving the IAQ should take into consideration the types of contamination.

Development and Characterizations of Environment-friendly Lime Paint (친환경성 석회 도료의 개발 및 특성 연구)

  • Hwang, Dae-Ju;Kim, Ho-Sung;Lee, Seung-Kwan;Choi, Moon-Kwan;Kim, Hwan;Lee, Jong-Dae
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.1
    • /
    • pp.47-52
    • /
    • 2009
  • Lime paint surpassing others in execution efficiency, anti-bacterial, anti-mold and small quantity emission of VOCs(Volatile Organic Compounds) characteristics was developed using a limestone as raw materials. The lime paint prepared by mixing slaked lime($37{\sim}40\;wt%$), PVA:EVA(9 wt%:1 wt%), talc(23 wt%), $TiO_2$(14 wt%), zeolite (3 wt%), antifoaming agent(5 wt%), wetting agent (5 wt%) was indicated over 99.8% of anti-bacterial and anti-mold characteristics. Also, the environment-friendly function of the lime paint was confirmed by detection of small amount of TVOCs($0.01\;mg/m^2h$) and formaldehyde($0.008\;mg/m^2h$). Execution efficiency, economy-and environment-friendly characteristics of this lime paint can make up for defects of established paints. And, it also presents the advantage of a limestone as high value added materials.

The photo-removal Characteristic of NOx by photocatalyst/scoria/loess concrete (광촉매가 첨가된 스코리아/황토 콘크리트의 NOx 제거 특성)

  • Ko, Seong-Hyun;Lee, Jae-Hoon;Hong, Chong-Hyun;Ryu, Soong-Phil;Kim, Moon-Hoon;Moon, Kyung-Jong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.593-596
    • /
    • 2006
  • The environment-friendly building material, photocatalyst/scoria/loess concrete, was prepared using scoria and loess (which have merits as building materials) and photocatalyst (which has the functions to compose the environmental contaminants and of self cleaning). In order to apply this material as a building material, the compressive and flexible strengths, and water absorptivity (which have been set by Korea Industrial Standard) were measured. In order to know the environment-friendly characteristics of this material, several tests, such as, the tests of emissivity and emission power of far infrared ray and acoustic absorptivity, antibacterial test for Escherichia coli and Pseudomonas aeruginosa, antifungal test for mixed fungal strains, and deodorization test of ammonia were carried out. Moreover, the removal characteristics of NOx, and formaldehyde (HCHO) by photocatalyst/scoria/loess concrete were examined as the following different parameters: the removal characteristics of these contaminants with the substitution ratio and the kind of photocatalyst, light source, UV intensity of sunlight, relative humidity, intial NOx concentration.

  • PDF

Studying indoor contaminant value according to vary ventilation and humidity, when operating bake-out on a new apartment (신축 공동주택 베이크 아웃시 환기.습도 변화에 따른 실내오염물질 저감비교)

  • Cho, Yeon-Hyo;Shin, Sung-Woo;Lee, Ji-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.702-707
    • /
    • 2008
  • Improving quality of life and wellbeing of the residential environment and increased interests and importance is growing confidentiality, insulation, high-rise due to a lack of ventilation and indoor air pollution. Several human diseases caused tremendously due to the indoor air which consists of formaldehyde, radon, pollutants such as volatile substances that is called the phenomenon of a new house syndrome. It has become a world-wide issue that the United States, Japan and several other countries of Europe are showing more interests. Furthermore, a lot of damages caused by the syndrome occurs in the new house should be resolved by somehow is urgent. Thus, this study would like to propose the measures based on the whether condition and the way of heating in korea against a new house syndrome via analysis of indoor contaminant Reduction comparison according to vary ventilation and humidity when operating bake-out on a new apartment.

  • PDF

Improved Mechanical and Durability Properties of PVC Sheet by Designing Three-Layered Structures

  • Park, Jun-Young;Kim, Woo-Sang;Kang, Hae-Cheon;Bae, Seokhu;Yoon, Jeong-Hwan;Yun, Juho;Lee, Eun-Kyoung;Kim, Namil
    • Elastomers and Composites
    • /
    • v.54 no.4
    • /
    • pp.294-298
    • /
    • 2019
  • A three-layered PVC sheet consisting of polyvinyl chloride (PVC) and woven polyester fabric was prepared by extrusion and calendering. The flexibility and durability of the PVC were tuned by adding plasticizers, additives, and surface coatings. The tensile and tear strengths of the three-layered PVC sheet were higher than those of commercial two-layered sheet, while exhibiting low weight. The concentrations of the total volatile organic compounds (TVOCs) and formaldehyde (HCHO) emitted from the sheet were also lowered. The PVC sheet remained stable after prolonged exposure to UV light, signifying that the PVC sheet is suitable for cargo screen applications.

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

GEMS BrO Retrieval Sensitivity Test Using a Radiative Transfer Model (복사전달모델을 이용한 GEMS 일산화브로민 산출 민감도 시험)

  • Chong, Heesung;Kim, Jhoon;Jeong, Ukkyo;Park, Sang Seo;Hong, Jaemin;Ahn, Dha Hyun;Cha, Hyeji;Lee, Won-Jin;Lee, Hae-jung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1491-1506
    • /
    • 2021
  • To estimate errors in GEMS retrievals for bromine monoxide (BrO) total vertical column densities(VCDs), we perform a sensitivity test using synthetic spectra generated by a radiative transfer model. Hourly synthetic data are produced for 00-07 UTC on the first day of every month in Jul 2013- Jun 2014. Solution errors estimated by the optimal estimation method tend to decrease with increasing air mass factors (AMFs) but increase when AMFs are larger than 5. Interference errors induced by formaldehyde (HCHO) absorption appear to be larger with smaller BrO AMFs. Total BrO retrieval errors estimated by combining solution and interference errors show an average of 26.74±30.18% for all data samples and 60.39±133.78% for those with solar zenith angles higher than 80°. Due to interfering spectral features and measurement errors not considered in thisstudy, errorsin BrO retrievals from actual GEMS measurements may have different magnitudes from our estimates. However, the variability of errors assessed in this study is still expected to appear in the actual BrO retrievals.

Carrageenan-Based Liquid Bioadhesives for Paper and Their Physical Properties (카라기난 기반 액상형 바이오 종이 접착제의 제조 및 물성에 관한 연구)

  • Oh, Seung-Jun;Han, Won-Sik;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.36 no.6
    • /
    • pp.541-548
    • /
    • 2020
  • There is a growing demand for natural materials to replace adhesives based on volatile organic compounds (VOCs). However, the exclusion of VOCs from the manufacturing process leads to difficulties in manufacturing, and reduction in productivity and preservability. In this paper, we report the manufacture of natural bioadhesives using the carrageenan component of seaweed. λ-carrageenan, isolated from the extracted total carrageenan, was used to prepare a highly stable adhesive for paper. The resulting composition was 52.0 ± 1.0% λ-carrageenan, 30.5 ± 0.5% Polyvinylpyrrolidone, 1.0 ± 0.05% ethylhexylglycerin, 1.5 ± 0.05% glycerin, 13.5 ± 0.5% dextrine, and 0.6 ± 0.05% food-grade antifoam emulsion. The viscosity was found to be 1.13 ± 0.07 × 105 cP (25℃), UV degradation occurred at pH6.22, drying rate was 15min, △b* was -10.79, and △E* ab was 8.18. The bioadhesive showed an excellent adhesion strength of 44.63 kgf/cm2. Thus this adhesive showed excellent fungal resistance and good adhesive persistence, without the presence of total volatile organic compounds (TVOC), formaldehyde (HCHO), and heavy metals.

A Study on the Air Quality of Indoor Screen Golf in Seoul (수도권 일부지역의 실내 스크린골프장의 공기질 평가)

  • Jo, Ho-Dong;Roh, Jae-Hoon;Kim, Chi-Nyon;Sim, Sang-Hyo;Won, Jong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.192-202
    • /
    • 2010
  • This study aimed to suggest the severity of indoor air pollutants in screen gold arenas which were not sufficiently investigated in Korea up to now and to help users to enjoy golf in more pleasant indoor environment. The indoor environment survey was conducted with 21 screen gold arenas in Seoul from Oct. 28, 2008 to March 13, 2009. Indoor air quality was measured and analyzed in accordance with the Air Pollution Process Test Method specified bu NIOSH(2005). The screen golf arenas are mostly in the underground floors in this study, 4 on the ground floors(19.0%) and 17 in the underground floors(81.0%). In the air in screen golf arenas, the geometric mean of benzene, toluene, ethylbenzene and xylene were 2.92 ${\mu}g/m^3$, 70.34 ${\mu}g/m^3$, 14.00${\mu}g/m^3$ and 31.43 ${\mu}g/m^3$, respectively, which exceeded the exposure limites. Each arena exceeded the exposure limit for one pollutant each. However, styrene didn't exceed the limit as 8.09 ${\mu}g/m^3$. Furthermore, the geometric mean of formaldehyde was 63.11${\mu}g/m^3$ and 7 arenas exceeded the limit. The geometric mean of volatile organic compounds(VOCs) was 428.41${\mu}g/m^3$ and 10 arenas exceeded the limit. For the density distribution of pollutants by location, benzene, toluene, ethylbenzene, xylene, styrene and formaldehyde showed higher density distribution in underground spaces, for which the statistically significant difference was not found. However, PM10 showed the statistically significant difference (p<0.05). In accordance with the analysis on the correlation between the density of pollutants in the screen golf arenas, Pearson correlation coefficient between ethylbenzene and styrene was 0.980, very significant correlation(p<0.01). The correlation coefficients between the density of toluene, ethylbenzene, xylene and styrene and that of VOCs were 0.543, 0.434, 0.451 and 0.459, respectively, which demonstrated the statistically significant difference (p<0.05).