• 제목/요약/키워드: Form of current

검색결과 2,593건 처리시간 0.026초

Phasor Estimation Algorithm Based on the Least Square Technique during CT Saturation

  • Lee, Dong-Gyu;Kang, Sang-Hee;Nam, Soon-Ryul
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.459-465
    • /
    • 2011
  • A phasor estimation algorithm based on the least square curve fitting technique for the distorted secondary current due to current transformer (CT) saturation is proposed. The mathematical form of the secondary current during CT saturation is represented as the scaled primary current with magnetizing current. The information on the scaled primary current is estimated using the least square technique, with the measured secondary current in the saturated section. The proposed method can estimate the phasor of a fundamental frequency component during the saturated period. The performance of the algorithm is validated under various fault and CT conditions using a C400 CT model. A series of performance evaluations shows that the proposed phasor estimation algorithm can estimate the phasor of the fundamental frequency component with high accuracy, regardless of fault conditions and CT characteristics.

유한요소해석을 이용한 전주공정에서의 전류밀도 분포 예측 (Estimate of Current Density Distribution in Electroforming Process Using Finite Element Analysis)

  • 강대철;김헌영;전병희
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.279-284
    • /
    • 2004
  • Electroforming is the highly specialized use of electrodeposition for the manufacture of metal parts and basically a specialized form of electroplating. So, we can apply electrochemical system analysis for electroforming process. Electrochemical systems are concerned with the interplay between electricity and chemistry, namely the measurements of electrical quantities, such as current density, potential, and charge, and their relationship to chemical parameters. This paper based on the basic equations of electrics and electrochemical kinetics, was employed for a theoretical explanation of the current density distribution on electroforming process. We calculated current density distribution and potential distribution on cathode. Also, calculated current density distribution of vertical direction. It was shown that current density is related with distance of between anode and cathode and mass transfer process.

와전류감쇠기의 동특성에 관한 연구 (A study on Dynamic Characteristics of an Eddy Current Damping)

  • 박정삼;배재성;황재혁;강국정
    • 항공우주시스템공학회지
    • /
    • 제2권3호
    • /
    • pp.24-28
    • /
    • 2008
  • Eddy current are induced when a nonmagnetic, conductive material is moving as the result of being subjected to the magnetic field, or if it is placed in a time-varying magnetic field. These currents circulate in the conductive material and are dissipated, causing a repulsive force between the magnet and conductor. Using this concept, eddy current damping can be used as a form of viscous damping. This paper investigated analytically and experimentally the characteristics of an eddy current damping when a permanent magnet is placed in a conductive tube. The theoretical model of the eddy current damping is developed from electromagnetics and is verified from Maxwell program and experiments. From these comparisons, although predictability is not accurate at high excitation frequencies, the present model can be used to predict damping force at low excitation frequencies. In order to improve the prediction of the characteristics of an eddy current damping, the induced magnetic flux densities have to be considered in following researches.

  • PDF

트랩을 통한 열적 천이와 터널링 천이를 동시에 고려할 수 있는 새로운 터널링 모델에 관한 연구 (New Tunneling Model Including both the Thermal and the Tunneling Transition through Trap)

  • 박장우;곽계달
    • 전자공학회논문지A
    • /
    • 제29A권8호
    • /
    • pp.71-77
    • /
    • 1992
  • According to increasing the doping concentration in p-n junction, a tunneling current through trap as well as SRH(Shockley-Read-Hall) generation-recombination current in depletion region occurs. It is the tunneling current that is a dominant current at the forward bias. In this paper, the new tunneling-recombination equation is derived. The thermal generation-recombination current and tunneling current though trap can be easily calculated at the same time because this equation has the same form as the SRH generation-recombination equation. For the validity of this equation, 2 kind of samples are simulated. The one is $n^{+}$-p junction device fabricated with MCT(Mercury Cadmium Telluride, mole fraction=0.29), the other Si n$^{+}-p^{+}$ junction. From the results for MCT $n^{+}$-p junction device and comparing the simulated and expermental I-V characteristics for Si n$^{+}-p^{+}$ junction, it is shown that this equation is a good description for tunneling through trap and thermal generation-recombination current calculation.

  • PDF

Obtaining the zwitterionic form of L-lysine from L-lysine monohydrochloride by electrodialysis

  • Aghajanyan, A.E.;Tsaturyan, A.O.;Hambardzumyan, A.A.;Saghyan, A.S.
    • Membrane and Water Treatment
    • /
    • 제4권1호
    • /
    • pp.1-9
    • /
    • 2013
  • The process of electromembrane transformation of L-lysine monohydrochlorides into their zwitterionic form in four- and two-chamber electrodialysis apparatus was investigated. The process of transformation at various concentrations of lysine monohydrochloride (0.1-0.6 mol.L-1) was studied and it was established that at the optimum density of current optimal concentrations of lysine hydrochloride during electrodyalisis was in the range of 0.2-0.4 mol.L-1. It was determined that the process of total transformation was accomplished when pH of the lysine solution achieved 10. Changes of concentrations of $Cl^-$ ions and lysine diffused into the neighboring chamber were determined depending on the time. The method developed by us allows adjusting the removal coefficient of $Cl^-$ ions during transformation to a maximal value, the losses of lysine diffused into the next chamber after its return to the technological cycle being less than 1.0 %. The specific energy consumption during the process of transformation in two- and four-chamber electrodialyzers was 0.19 and 0.205 A.h.kg-1 and the current efficiency was 75.9 and 73.1 %, correspondingly. Study of the process of electromembrane transformation allowed obtaining zwitterionic form of L-lysine from L-lysine monohydrochloride with minimal reagent and energy consumption.

비대칭과 대칭 단동선형을 가진 쌍동선의 조파저항성능 분석 (Wave-resistance Performance Analysis of the Twin Hull for a Type of the Asymmetric and Symmetric Mono Hull)

  • 최희종;박동우
    • 해양환경안전학회지
    • /
    • 제19권1호
    • /
    • pp.78-84
    • /
    • 2013
  • 본 연구의 주목적은 쌍동선형의 조파저항성능을 평가할 수 있는 수치해석 프로그램을 개발하는 것이다. 개발된 프로그램을 이용하여 비대칭과 대칭인 단동선형을 가진 서로 다른 두 가지 쌍동선에 대하여 수치계산을 수행하여 저항성능을 평가 하였다. 타당성 검증을 위해서 수치해석 결과 중 선수와 선미에서의 침하량, 트림 그리고 조파저항 계수를 수조모형시험 결과와 비교하였다. 이러한 비대칭 그리고 대칭 선형이 가지는 쌍동선의 유체역학적 특성에 관한 비교분석 자료는 향후 선형개발 시 충분한 활용 가치가 있다고 판단된다.

공업화자재의 활용을 통한 공정합리화 (Building construction process improvement using prefabricated materia)

  • 윤유상;이형수;서상욱
    • 한국건설관리학회논문집
    • /
    • 제4권1호
    • /
    • pp.90-96
    • /
    • 2003
  • 도심지 건축공사가 증가하고 있는 우리나라에서 작업공간의 부족 및 자재의 적시공급에 대한 문제는 반드시 해결해야 할 과제이다. 이 중에서도 주택건설에 있어 가장 큰 비중을 차지하고 있는 아파트 시공의 경우, 초고층화로 골조공사의 중요성과 함께 친환경적 공법과 합리적 공정개선 및 원가절감을 구현할 새로운 공법이 요구되고 있다. 본 연구에서는 국내 건설현장의 사례조사를 통해 슬래브 거푸집공사와 마감공사의 프로세스에서 불필요한 요소를 최소화하고자 공업화 자재를 활용한 (골조-마감공사)통합공법을 제시한다 가치흐름분석기법(Value Stream Mapping)을 활용하여 기존 프로세스에서의 비 가치 창출작업을 가치창출작업에 통합시키거나 제거하여 슬래브 공사 내에서 공기 및 투입인력의 절감 가능성을 확인하고, 공기단축과 원가절감 효과를 측정하였다. 이와 같이 공업화 자재의 활용으로 현장작업에 따른 변이를 최소화하여 공정의 안정성 및 공정계획의 신뢰성을 확보 등 공정의 합리화를 구현하고자 한다.

HgCdTe 광 다이오드의 터널링 전류 계산 (Tunneling Current Calculation in HgCdTe Photodiode)

  • 박장우;곽계달
    • 전자공학회논문지A
    • /
    • 제29A권9호
    • /
    • pp.56-64
    • /
    • 1992
  • Because of a small bandgap energy, a high doping density, and a low operating temperature, the dark current in HgCdTe photodiode is almost composed of a tunneling current. The tunneling current is devided into an indirect tunneling current via traps and a band-to-band direct tunneling current. The indirect tunneling current dominates the dark current for a relatively high temperature and a low reverse bias and forward bias. For a low temperature and a high reverse bias the direct tunneling current dominates. In this paper, to verify the tunneling currents in HgCdTe photodiode, the new tunneling-recombination equation via trap is introduced and tunneling-recombination current is calculated. The new tunneling-recombination equation via trap have the same form as SRH (Shockley-Read-Hall) generation-recombination equation and the tunneling effect is included in recombination times in this equation. Chakrabory and Biswas's equation being introduced, band to band direct tunneling current are calculated. By using these equations, HgCdTe (mole fraction, 0.29 and 0.222) photodiodes are analyzed. Then the temperature dependence of the tunneling-recombination current via trap and band to band direct tunneling current are shown and it can be known what is dominant current according to the applied bias at athe special temperature.

  • PDF

제어기 성능을 고려한 전압형 인버터의 출력 LC필터 설계 (Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller)

  • 민완기;김재식;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.206-211
    • /
    • 2005
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.

  • PDF

무정전전원장치용 단상 전압형 인버터의 출력 LC필터 설계 (Output LC Filter Design of Single Phase Voltage Source Inverter Used for Uninterruptible Power Supply)

  • 민완기;김재식;최재호
    • 전기학회논문지P
    • /
    • 제56권2호
    • /
    • pp.83-89
    • /
    • 2007
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.