• Title/Summary/Keyword: Form factor

Search Result 2,675, Processing Time 0.025 seconds

Various Genioplasty techniques and case presentations (턱끝 성형술의 다양한 절골술식과 임상증례)

  • Choi, Jin Young
    • The Journal of the Korean dental association
    • /
    • v.58 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • The form and location of chin is very important factor which determine the facial impression. Genioplasty is getting popular in order to improve the facial impression as facial beauty is considered as improvable factor. Through the geniplasty, chin can be moved to wanted location 3 dimensionally Genioplasty is relative simple but precise diagnosis and accurate surgical technique is very important for accurate and satisfying results. The form and shape of chin itself can be analysized and also must be evalulated in relation to the nose and lip and face. Author introduces the analysis of the chin, various surgical techniques of genioplasty and presents some cases.

  • PDF

A Recombinant Mous GM-CSF Protein Expressed as an Inclusion Form Shows Colony Stimulating Activity

  • Hyun Joo Youn;Jin-Kyoo Kim;Eun-Jung Sohn;Soo-O Lee;Choon-Taek Lee
    • Journal of Microbiology
    • /
    • v.38 no.2
    • /
    • pp.109-112
    • /
    • 2000
  • Granulocyte-macrophage colony-stimulating factor (GM-CSF) is a pleiotropic hematopoietic growth factor and an activator of lmature myeloid cells and recombinant GM-CSF is increasingly under clinical studies for the treatment of various diseases including cancer, infectious diseases and hematopoietic diseases. We constructed a reconbinant mouse GM-CSF expression plasmid with pelB leader sequence and His. Tag under T7 promoter control, and showed that the construct produced a 20 kDa recombinant protein in 8M urea. We also showed that the 20 kDa recombinant protein prepared in 8M urea sitmulated colony formation in vitro, indicating that the recombinant mGM-CSF can be renatured to its native form to show the colony stimulating activity.

  • PDF

Fabrication of micro mirror array for small form factor optical pick-up by micro UV-molding (마이크로 UV 성형을 통한 초소형 광픽업용 마이크로 미러 어레이 제작)

  • Choi Yong;Lim Jiseok;Kim Seokmin;Sohn Jin-Seung;Kim Hae-Sung;Kang Shinill
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.47-50
    • /
    • 2005
  • In this study, micro mirror array for small form factor optical pick-up was replicated by micro UV-molding. First, mold for micro mirror array was fabricated using micromachining. Also, to analyze the characteristics of the surface quality, flatness of replicated mirror surface were measured by white light scanning inteferometry system. The results show that the micro mirror array with a sufficient surface quality can be obtained by polymer replication process.

  • PDF

2.3mm Height Actuator for Small Form factor Optical Drive (초소형드라이브를 위한 2.3mm 액추에어터)

  • Cheong, Young-Min;Lee, Jin-Won;Kim, Kwang;Kang, Jong-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.61-64
    • /
    • 2004
  • Recently, as the requirements of several mobile products come to the front, to cope with the market needs, various mobile storage applications have appeared. Therefore, the core components and technologies for mobile optical disc drives have been developed continuously. In case of the optical storage, the small sized optical pickup is necessary to realize the mobile optical disc drive, because the optical pickup height is determined by the optical parts and an actuator. In this paper, we propose the optical pickup actuator using the horizontally arranged magnetic circuit, and apply to 5mm height Small Form-factor Optical Drive.

  • PDF

Development of Night Vision Imaging System Green A Compatible LED for Avionic Applications (항공전자 응용을 위한 NVIS (Night Vision Imaging System) Green A 호환 LED 개발)

  • Kim, Tae Hoon;Yu, Chang Han;Yoon, Hyeon Ju;Kim, Min Pyung;Yoon, Ho Shin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.1-5
    • /
    • 2020
  • By adapting black body leadflame and thin film type Green A filter, we successfully demonstrated night vision imaging system (NVIS) Green A compatible LED. Fabricated NVIS compatible LEDs show small form factor compared to that of commercialized NVIS compatible LED. Especially, NVIS radiance and chromaticity of MIL-STD-3009 specification can be satisfied simultaneously and easily by controlling the color temperature of the white LED as well as the concentration of the Green A dye and the thickness of the Green A filter. The optimal dye concentration of the NVIS Green A filter is expected to be about 1 wt%. The results of this study are expected to contribute to miniaturization, weight reduction and localization of avionic display and lighting devices.

Calculation of X-ray attenuation coefficients for normal and cancerous breast tissues

  • Aysun Boke
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.241-246
    • /
    • 2024
  • The study was carried out by numerical integration based on the diffraction properties and elemental composition. The elemental compositions of breast tissues in the literature were tested. The photon attenuation coefficients calculated using the recent elemental composition were found within 0.2-16% for adipose tissue and within 0.04-17% for glandular tissue with the experimental reference data. The attenuation coefficients of cancerous breast tissue calculated according to the elemental content previously measured in breast cancer patients were found within 0-17% with experimental data in the literature. The attenuation coefficients are of great interest to medical research. To calculate realistic attenuation coefficients, the characteristic coherent scatter, which is most intense at small angles, must be considered. For this reason, experimentally measured form factor data were reviewed, and the most compatible one with the theoretical form factor data produced in this study was used at low momentum transfer x (0 < x ≤ 8 nm-1). The differential linear coherent scattering distributions were calculated for an energy value of 17.44 keV and compared with their experimental counterparts.

An Objective Procedure to Decide the Scale Factors for Applying Land-form Classification Methodology Using TPI (TPI 응용에 의한 산악지형 분류기법의 적용을 위한 scale factor 선정방법 개발)

  • Jang, Kwangmin;Song, Jungeun;Park, Kyeung;Chung, Joosang
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.6
    • /
    • pp.639-645
    • /
    • 2009
  • The objective of this research was to introduce the TPI approach for interpreting land-forms of mountain forests in South Korea. We develop an objective procedure to decide the scale factor as a basic analytical unit in land-form classification of rugged mountain areas using TPI. In order to determine the scale factor associated with the pattern of slope profiles, the gradient variance curve was derived from a revised hypsometric curve developed using the relief energy of topographic profiles. Using the gradient variance curve, found was the grid size with which the change in relief energy got the peak point. The grid size at the peak point was determined as the scale factor for the study area. In order to investigate the performance of the procedure based on the gradient variance curve, it was applied to determination of the site-specific scale factors of 3 different terrain conditions; highly-rugged, moderately-rugged and relatively less-rugged. The TPI associated with the corresponding scale factors by study site was, then, determined and used in classifying the land-forms. According to the results of this study, the scale factor gets shorter with more rugged terrain conditions. It was also found that the numbers of valleys and ridges estimated with TPI show almost the same trends as those of the observed and the scale factors tends to approach to the mean distance of ridges.

A New Dual Hardy-Hilbert's Inequality with some Parameters and its Reverse

  • Zhong, Wuyi
    • Kyungpook Mathematical Journal
    • /
    • v.49 no.3
    • /
    • pp.493-506
    • /
    • 2009
  • By using the improved Euler-Maclaurin summation formula and estimating the weight coefficients in this paper, a new dual Hardy-Hilbert's inequality and its reverse form are obtained, which are all with two pairs of conjugate exponents (p, q); (r, s) and a independent parameter ${\lambda}$. In addition, some equivalent forms of the inequalities are considered. We also prove that the constant factors in the new inequalities are all the best possible. As a particular case of our results, we obtain the reverse form of a famous Hardy-Hilbert's inequality.

Productivity Assessment of Form Works According to Work Elements (공동주택 거푸집공사의 작업요소별 생산성 분석)

  • Ha, Gee-Joo;Choi, Min-Kwon;Yi, Dong-Ryul;Ha, Young-Joo;Ha, Min-Su;Kim, Jin-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.161-163
    • /
    • 2010
  • In this study, it was accomplished the analysis of apartment house shape and the work factor productivity of the form work for the application of rational construction cost in apartment house. The form work is highly depended on the manpower in frame construction, and it has been a high impact during estimating of frame work cost.

  • PDF

The OMM system for machined form and surface roughness measurement concerned with volumetric error (기계 체적오차가 고려된 가공형상-거칠기 측정 OMM 시스템)

  • 이상준;김선호;김옥현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.681-686
    • /
    • 2000
  • Machining information such as machined form and surface roughness accuracy is an important factor for manufacturing precise parts. To this regard, OMM(On the Machine Measurement) has been issued for last several decades to alternate with CMM. In this research, measuring system consisting of a laser probe is developed for machined form and surface roughness measurement on the machine tool. The obtained machined form accuracy is compared with reference one defined in CAD model. The measured surface roughness data is compared with measured master surface beforehand. Furthermore, using the pre-defined volumetric error map approach compensates the geometric accuracy of the machine tool. The overall performance is compared with CMM, and verified the feasibility of the measurement system.

  • PDF