• Title/Summary/Keyword: Force of fire

Search Result 211, Processing Time 0.029 seconds

Consideration on Fire-prevention Facilities for Wooden Cultural Heritages (목조문화재 보존을 위한 소방시설에 대한 고찰)

  • Kim, Tae-Goo
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.155-171
    • /
    • 2010
  • Wooden cultural heritages have many factors of fires and structural characteristics vulnerable to the fire extinguishing. Also, they are surrounded with forests and so remote from fire stations, which make it difficult to handle it quickly when fires break out. Wooden cultural heritages made of wood materials belong to the general fire in a Class A. Taking characteristics such as a smoldering and a backfire from the that fire of wooden materials into consideration, extinguishing the fire by the cooling system is the most effective. If the fire can't be put out at the early stage, it is almost impossible to protect wooden cultural heritages from the fire, because wooden structures can be destroyed in a high temperature and in a short time and it takes around average 7 minutes to reach its peak of flames in the process of a fire. According to the geographical and environmental situation of the cultural heritages, currently, the fire-prevention facilities such as the auto fire detector for the prompt detection, the water mist fire suppression system for the 1st early and urgent fire suppression and the outdoor fire hydrant and the water curtain etc. for the 2nd full-scale suppression and the prevention of the fire gaining force are being installed for the wooden cultural heritages.

  • PDF

Analysis of Foot Pressure according to the Work Postures on Fire Fighters (소방대원들의 작업자세에 따른 족저압력 분석)

  • Son, Sung Min;Roh, Hyo Lyun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.88-94
    • /
    • 2013
  • The purpose of this study is to find out the difference of foot pressure according to the firefighter's work postures for providing the basic information to prevent Musculoskeletal disorders. This study was conducted by 9 male firefighters. Work postures were selected for rescuee handling, fire hose and hydraulic rescue equipment work postures. These were divided into 3 position, "High", "Middle" and the postures of taking out and letting down hydraulic rescue equipment were analyzed as starting point and end point respectively. Foot Pressure was used to analyze contact area, peak pressure, and maximum force in terms of work postures, and compared between fire hose and hydraulic rescue equipment work postures. The results of foot pressure are as follows. According to the results of rescuee handling work postures, one person handling posture showed wide contact area and foot pressure showed the highest at right foot. Accoridng to the (High), (Middle), (Low) postures of fire hose, the results didn't show the difference among the contact area, peak pressure and maximum force. As the results of hydraulic rescue equipment work postures, (Low) postures showed the highest in terms of the right foot of contact area, peak pressure and maximum force and (High) postures showed the highest in left foot. The increase of foot pressure lead to be inconvenience of low extremity and muscle fatigue for maintaining postural control cause pain. Thus, it is necessary to design insole-equipped working shoe for reduce the impulse and effect of foot during the rescuee handling work which standing out as foot pressure.

A Study on the Closing Force according to the Opening Angle of the Door in the Smoke Control System (제연구역 출입문 개방 각도에 따른 폐쇄력에 관한 연구)

  • Oh, Won-Sin;Joung, Suck-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.43-48
    • /
    • 2021
  • In this study, the experiment was conducted on a fire door(W × H = 0.98 m × 2.19 m) installed on the vestibule. The effective leakage area for each opening angles and closing forces derived from the impulse-momentum equation was compared and analyzed with the experimental results. As a result of the experiment, the major factors affecting the door closing forces were the pressure difference and the area of the door. The difference of door closing forces between measured and calculated values by the impulse-momentum equation showed a deviation of less than ±15% at the opening angles of 5°to 10°. At the door opening angle of 2.5°, the dynamic pressure was much higher than the measured static pressure, and this pressure difference is estimated to be air resistance acting to prevent the door from being completely closed.

Assessment of Post-Earthquake Fire Behavior of a Steel MRF Building in a Low Seismic Region

  • Chicchi, Rachel;Varma, Amit
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1470-1481
    • /
    • 2018
  • Building-level response to post-earthquake fire hazards in steel buildings has been assessed using primarily two-dimensional analyses of the lateral force resisting system. This approach may not adequately consider potential vulnerabilities in the gravity framing system. For this reason, three-dimensional (3D) finite element models of a 10-story case study building with perimeter moment resisting frames were developed to analyze post-earthquake fire events and better understand building response. Earthquakes are simulated using ground motion time histories, while Eurocode parametric time-temperature curves are used to represent compartment fires. Incremental dynamic analysis and incremental fire analysis procedures capture a range of hazard intensities. Findings show that the structural response due to earthquake and fire hazards are somewhat decoupled from one another. Regardless of the level of plastic hinging present in the moment framing system due to a seismic event, gravity column failure is the initiating failure mode in a fire event.

A Study on the Slip Test of Shear Connector in Fire (전단 연결재의 고온 성능 평가에 관한 연구)

  • Han, Sang-Hoon;Park, Won-Sup;Lee, Choul-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.48-51
    • /
    • 2008
  • Shear connector is the element which resist in the horizontal shear force between steel and concrete of composite members and the stud bolt is often used because of its constructional convenience and serviceability. Although the push-out test is the most common method to evaluate shear slip behaviour, it is suitable for only room temperature conditions. In this study, we investigated about shear force, temperature distribution and slip displacement of shear connector in high temperature through the modified push-out test with electronic furnace invented for steel part heating.

  • PDF

A Numerical Study on Hydrodynamic Force Affecting the Vertical Wall of a Portable Water Storage Tank (자유수면의 출렁임이 이동형 소방용수 저장탱크의 수직 벽면에 미치는 동수력에 대한 수치해석)

  • Park, Jinsoo;So, Soohyun;Jang, Taek Soo
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.49-53
    • /
    • 2017
  • In the present study, the hydrodynamic force acting on the vertical wall of a portable water storage tank is examined. A Dispersion Relation Preserving (DRP) method, proposed by Jang, is applied for simulating lapping waves and their impact on the wall. A meaningful investigation has been observed, which may be applied to the strength design for the portable water storage tank.

Numerical and Experimental Study on the Fire Whirl Characteristics of Oriental Oak Leaves (굴참나무 낙엽의 Fire Whirl 특성에 관한 실험 및 수치해석 연구)

  • Bae, Sung-Yong;Ryou, Hong-Sun;Hong, Gi-Bae
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.73-78
    • /
    • 2009
  • The fire whirl occurring in the urban and/or wildland fire is generated by the instabilities of atmosphere. The fire whirl is a rare phenomenon, but highly destructive because it has high inhalation and lift force. In this study, experimental and numerical studies are performed with oriental oak leaves, for investigating of the fire whirl characteristics occurred in wildland fire. As a result of experiment, the circulation intensity increases as the induced air speed increases, then the heat release rate and flame height increase 22.8%, 18.4% compared with open fire in highest circulation. Furthermore the numerical results shows same trend with the experiment.

Reduction of Hydrodynamic Force Acting on the Vertical Wall of a Portable Water Storage Tank by Convex bottom Design (볼록한 바닥면 설계를 통한 소방용수 저장탱크의 수직 벽면에서의 동수력 저감 연구)

  • So, Soohyun;Park, Jinsoo;Sung, Hong Gun;Jang, Taek Soo
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.69-73
    • /
    • 2018
  • This study examined the reduction effect of a hydrodynamic force acting on the vertical wall of a portable water storage tank with a convex bottom floor. For the numerical simulation, the linearized Peregrine's equation was used to analyze the lapping waves in the tank caused by water falling from a supplying nozzle. The hydrodynamic force could be calculated by measuring the maximum run-up wave height at the vertical wall. The initial conditions of the numerical experiments were set up by controlling the positions and heights of the water supplying nozzle. Finally, the hydrodynamic force acting on the vertical wall can be reduced by the convex bottom design of the portable water storage tank so it can be applied to improve the structural stability.

Study on Improvement of Fire Investigation System (화재조사제도 개선방안에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.101-110
    • /
    • 2009
  • As the current fire investigation system in Korea has been performed mainly by the public sector such as fire service, police, etc., private fire investigation system such as 'private fire investigator system' to protect rights and interests of the sufferers from the fire accidents due to defective products showed very deficient. In addition, since the laws and regulations concerned about fire investigation are distributed into and applied for each organization, a lot of problems have been generated such as civil appeals due to duplicated investigations among similar organizations, excess reaction to exclude other organization from the fire investigation field, inefficient waste of administration force due to duplicated operation of fire investigation organization and manpower, etc. This study has surveyed generation operation conditions and problems of the fire investigation system in Korea and drawn its improvement method on the public and private sectors.

Study on the fire resistance of castellated composite beams with ortho-hexagonal holes and different beam-end constraints

  • Junli Lyu;Encong Zhu;Rukai Li;Bai Sun;Zili Wang
    • Steel and Composite Structures
    • /
    • v.46 no.4
    • /
    • pp.539-551
    • /
    • 2023
  • In order to study the fire resistance of castellated composite beams with ortho-hexagonal holes and different beam-end restraints, temperature rise tests with constant load were conducted on full-scale castellated composite beams with ortho-hexagonal holes and hinge or rigid joint constraints to investigate the temperature distribution, displacement changes and failure patterns of castellated composite beams with two different beam-end constraints during the whole course of fire. The results show that (1) During the fire, the axial pressure and horizontal expansion deformation generated in the rigid joint constrained composite beam were larger than those in the hinge joint constrained castellated composite beam, and their maximum horizontal expansion displacements were 30.2 mm and 17.8 mm, respectively. (2) After the fire, the cracks on the slab surface of the castellated composite beam with rigid joint constraint were more complicated than hinge restraint, and the failure more serious; the lower flange and web at the ends of the castellated steal beams with hinge and rigid joint constraint produced serious local buckling, and the angles of the ortho-hexagonal holes at the support cracked; the welds at both ends of the castellated composite beam with rigid joint constraint cracked. (3) Based on the simplified calculation method of solid-web composite beam, considering the effect of holes on the web, this paper calculated the axial force and displacement of the beam-end constrained castellated composite beams under fire. The calculation results agreed well with the test results.