• Title/Summary/Keyword: Force measuring

Search Result 948, Processing Time 0.036 seconds

The gene expression programming method to generate an equation to estimate fracture toughness of reinforced concrete

  • Ahmadreza Khodayari;Danial Fakhri;Adil Hussein, Mohammed;Ibrahim Albaijan;Arsalan Mahmoodzadeh;Hawkar Hashim Ibrahim;Ahmed Babeker Elhag;Shima Rashidi
    • Steel and Composite Structures
    • /
    • v.48 no.2
    • /
    • pp.163-177
    • /
    • 2023
  • Complex and intricate preparation techniques, the imperative for utmost precision and sensitivity in instrumentation, premature sample failure, and fragile specimens collectively contribute to the arduous task of measuring the fracture toughness of concrete in the laboratory. The objective of this research is to introduce and refine an equation based on the gene expression programming (GEP) method to calculate the fracture toughness of reinforced concrete, thereby minimizing the need for costly and time-consuming laboratory experiments. To accomplish this, various types of reinforced concrete, each incorporating distinct ratios of fibers and additives, were subjected to diverse loading angles relative to the initial crack (α) in order to ascertain the effective fracture toughness (Keff) of 660 samples utilizing the central straight notched Brazilian disc (CSNBD) test. Within the datasets, six pivotal input factors influencing the Keff of concrete, namely sample type (ST), diameter (D), thickness (t), length (L), force (F), and α, were taken into account. The ST and α parameters represent crucial inputs in the model presented in this study, marking the first instance that their influence has been examined via the CSNBD test. Of the 660 datasets, 460 were utilized for training purposes, while 100 each were allotted for testing and validation of the model. The GEP model was fine-tuned based on the training datasets, and its efficacy was evaluated using the separate test and validation datasets. In subsequent stages, the GEP model was optimized, yielding the most robust models. Ultimately, an equation was derived by averaging the most exemplary models, providing a means to predict the Keff parameter. This averaged equation exhibited exceptional proficiency in predicting the Keff of concrete. The significance of this work lies in the possibility of obtaining the Keff parameter without investing copious amounts of time and resources into the CSNBD test, simply by inputting the relevant parameters into the equation derived for diverse samples of reinforced concrete subject to varied loading angles.

The Experimental Study on the Transient Brake Time of Vehicles by Road Pavement and Friction Coefficient (노면 포장별 차량의 제동경과시간 및 마찰계수에 관한 실험적 연구)

  • Lim, Chang-Sik;Choi, Yang-Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6D
    • /
    • pp.587-597
    • /
    • 2010
  • When a car accident occurs, people who had an accident are not free from civil and criminal issues so that the accident investigator should reenact and analyze the accident situation accurately. In addition, the obtained documents through the analysis of such car accident occurrence and related factors have to be used to carry out the improvement of the areas that has numerous car accidents and complementary actions. The vehicle speed, accelerating force, braking power are currently known as the most affecting factors in accordance with many car accidents, traffic facilities, road design, etc. The vehicle's performance and rode friction coefficient road surface friction coefficient are affecting the most closely in this field. Especially, once the estimate of the speed of the accident moment relating to main eleven articles of Traffic Accident Exemption Law is very important and accuracy is required. However, currently the researches of these matters have not made exclusively yet in Korea. In this study by reflecting this current situation, until the sudden braking history is found from the car's sudden braking, it estimates accurately the transient brake time and rode friction coefficient by measuring a time of transient brake time through the precision speed detector (Vericom VC2000PC). The analysis of the experimental results calculated the transient brake time and friction coefficient to fit into the purpose of this study in the basis of different kind of various special purpose asphalt pavement and slip-prevention pavement and provided the fundamental data.

Development Direction of Maritime Manned-Unmanned Systems through Measurement of Combat Effectiveness against Major Threats on Sea Lines of Communication (해상교통로 상 주요 위협별 전투 효과 측정을 통한 해양 유·무인 복합체계 발전방향)

  • Yong-Hoon Kim;Yonghoon Ha
    • Journal of Industrial Convergence
    • /
    • v.21 no.11
    • /
    • pp.29-41
    • /
    • 2023
  • In this study, assuming that the maritime manned-unmanned systems, which will be used as the main force of the ROK Navy in the future, conducts its sea line of communication(SLOC) protection operations, the combat effectiveness against major threats was measured, and through this, the development direction of the manned-unmanned systems was suggested. Multi-criteria decision-making techniques such as Delphi and AHP were used to measure combat effectiveness, and the AHP survey was conducted on 40 naval officers, including 25 senior officers who are well-understood in the combat effectiveness of the weapons system and MUM-T. As an evaluation index for measuring combat effectiveness, the OODA loop was set as the main attribute, followed by Observe(0.358), Orient(0.315), Act(0.217), and Decide(0.110). The combat effectiveness of each major threat in SLOC, the lowest alternative, was measured to be 1.68 times higher than the response to maritime conflicts in neighboring countries and 3.61 times higher than the response to transnational threats. These results are expected to support rational decision-making in determining the level of technology required for acquisition of marine manned-unmanned systems and establishing operational plans for naval forces.

The effect of a static magnetic field of Nd-Fe-B magnet on alkaline phosphatase activity of MC3T3-E1 cells (Nd-Fe-B 자석의 정자기장이 MC3T3-E1 세포의 alkaline phosphatase 활성도에 미치는 영향)

  • Kim, Sook-Hee;Kwon, Oh-Won;Ryoo, Hyun-Mo
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.205-214
    • /
    • 2000
  • Recently, the magnetic force has been considered as a method for a more efficient tooth movement. The purpose of this study was to evaluate the effects of different static magnetic fields of Nd-Fe-B magnet on MC3T3-E1 cells by measuring the alkaline phosphatase activity and observing the amount of stained alkaline phosphatase. For measuring of alkaline phosphatase activity, MC3T3-E1 cells were seeded in first and third row of 12 well culture plates. And Nd-Fe-B magnets were positioned under the first column of first and third row to apply different static magnetic fields(first column:100mT ; second column:4.6mT ; third column:0.5mT ; forth column:0.0mT) to the cells for 7, 13, 19, and 25 days. For staining of alkaline phosphatase, MC3T3-E1 cells were seeded in 100mm culture plates. And Nd-Fe-B magnets were positioned under the corner of plates to apply different static magnetic fields(magnet side:100mT : the opposite side:0.5mT) to the cells for 7, 13, 19, and 25 days. The results were as follows : 1. ALP activity was increased until day 19 in biochemical determination as well as in histochemical staining, 2. The application of higher magnetic field(100mT) suppressed ALP activity at day 13, 19, 25. On the contrary, the application of the lower magnetic field(4.6mT, 0.5mT) significantly enhanced the ALP activity. 3. Consistent with enzyme assay, histochemical staining of ALP also demonstrated that higher magnetic field(100mT) suppressed ALP activity, lower one(0.5mT) enhanced.

  • PDF

Increased Water Resistance and Adhesion Force to Skin through the Hybrid of Fatty Acid Ester and Titanium Dioxide (지방산 에스테르와 티타늄다이옥사이드의 복합화를 통한 내수성과 피부 밀착력 개선)

  • Ji Yeon Hong;Chi Je Park;Yong Woo Kim;Sang Keun Han;Sung Bong Kye;Ho Sik Roh;Soo Nam Park
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.3
    • /
    • pp.247-258
    • /
    • 2023
  • This study aims to investigate the enhancement of water resistance and improvement in adhesion to the skin by combining dextrin palmitate and isopropyl titanium triisostearate coating materials with titanium dioxide. Due to the recent increase in consumers who enjoy outdoor activities, the demand for sunscreen with excellent water resistance is increasing. Prior research was conducted with O/W, Pickering, and W/O/W multiple formulations, but there was a limit to water resistance. The purpose of this study is to develop a complex inorganic powder that can improve water resistance and increase adhesion to the skin to solve this problem. First, we combined dextrin palmitate and isopropyl titanium triisostearate coating materials to form a composite with titanium dioxide. The coating of the inorganic powder was confirmed using FE-SEM and FT-IR analysis. The composite exhibited significantly higher in vitro water resistance compared to other formulations. The hydrophobicity of the coated inorganic powder was compared by measuring the contact angles. When the coated inorganic powder was applied to the W/O sunscreen formulation and the non-coated inorganic powder was applied to the W/O sunscreen formulation as a control, the SPF of the sunscreen containing the coated inorganic powder was higher. These results were the same when observed with a UV camera. Finally the adhesion of the coated inorganic powder to the skin was assessed by applying it to a foundation product. In vivo study, it was observed that the product formulated with the coated powder exhibited less smudging compared to the foundation product formulated with the non-coated powder. The developed inorganic powder in this study demonstrated excellent adhesion to the skin, providing a superior sensory experience, as well as enhanced hydrophobicity and remarkable water resistance effects. In the future, the result of this study is expected to help develop various sunscreen products to improve water resistance.

Effect of Experimental Muscle Fatigue on Muscle Pain and Occlusal Pattern (실험적으로 유발되는 근피로가 근통증 및 교합양상에 미치는 영향)

  • Kim, Jae-Chang;Lim, Hyun-Dae;Kang, Jin-Kyu;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.3
    • /
    • pp.279-294
    • /
    • 2008
  • This study aimed to make an analysis of the occlusion in the state of muscle fatigue produced by excessive mouth opening and clenching during the dental treatment to control the dental pain and to evaluate the sensory nerve in the muscle pain state. Most of the reasons why patients visit the dental office result in pain-either conceivably the dental origin pain or the non-dental origin pain. The dental offices have many therapeutic actions to produce the masticatory muscle fatigue for the treatment. Dental treatment with long minutes of mouth opening can cause some headaches, masticatory muscle pain and mouth opening difficulties. Patients with mastication problems who visits a dental office to alleviate pain run against another unexpected pain with other aspects. This study uses T-scan II system(Tekscan Co., USA) for the evaluation on the occlusal pattern in the experimental muscle fatigue after clenching, opening the mouth excessively and chewing gum. The occlusal contact pattern is analyzed by the contact timing, namely first, intercuspal, maximum and end point of contact. This inspection was performed at frequencies of 2000Hz, 250 Hz and 5 Hz before and after each experimental muscle pain was produced to 24 subjects who had normal occlusion without the orthodontic treatment or a wide range of the prosthesis by using $neurometer^{\circledR}$ CPT/C(Neurotron, Inc. Baltimore, Maryland, USA). The measuring sites were mandibular nerve experimental muscle fatigue respectively. This study could obtain the following results after the assessment of occlusion and sensory nerve of the experimental muscle fatigue. 1. There were the fastest expression after the excessive mouth opening in muscle fatigue and after tooth clenching in muscle pain. In the visual analog scale that records the subjective level, there was the highest scale after the clenching in the muscle fatigue in jumping off the point of pain. 2. Tooth contact time, contact force, relative contact force on the point of the first contact had no difference, and there were decreases in the contact force after the excessive mouth opening on intercuspal position point, after the excessive mouth opening and the gum chewing on the point of the maximum, and in the contact time after all the experimental muscle fatigue state on the point of the end contact. 3. There was no statistic significance in the current perception threshold before and after the experimental muscle fatigue. 4. There was no significant difference in the contact number, the maximal contact number on the point of the first contact, and the contact number after the mouth opening and gum chewing on the point of the intercuspal position and the contact number after the experimental muscle fatigue on the maximum point, and showed significant decreases. In conclusion, it was found that the occlusal pattern can cause the changes on the case of the clinical muscle weakness by intra-external oral events. It was important that the sedulous attention to details is required during dental treatment in case of excessive mouth opening, mastication and clenching.

Construction and Application of Intelligent Decision Support System through Defense Ontology - Application example of Air Force Logistics Situation Management System (국방 온톨로지를 통한 지능형 의사결정지원시스템 구축 및 활용 - 공군 군수상황관리체계 적용 사례)

  • Jo, Wongi;Kim, Hak-Jin
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.2
    • /
    • pp.77-97
    • /
    • 2019
  • The large amount of data that emerges from the initial connection environment of the Fourth Industrial Revolution is a major factor that distinguishes the Fourth Industrial Revolution from the existing production environment. This environment has two-sided features that allow it to produce data while using it. And the data produced so produces another value. Due to the massive scale of data, future information systems need to process more data in terms of quantities than existing information systems. In addition, in terms of quality, only a large amount of data, Ability is required. In a small-scale information system, it is possible for a person to accurately understand the system and obtain the necessary information, but in a variety of complex systems where it is difficult to understand the system accurately, it becomes increasingly difficult to acquire the desired information. In other words, more accurate processing of large amounts of data has become a basic condition for future information systems. This problem related to the efficient performance of the information system can be solved by building a semantic web which enables various information processing by expressing the collected data as an ontology that can be understood by not only people but also computers. For example, as in most other organizations, IT has been introduced in the military, and most of the work has been done through information systems. Currently, most of the work is done through information systems. As existing systems contain increasingly large amounts of data, efforts are needed to make the system easier to use through its data utilization. An ontology-based system has a large data semantic network through connection with other systems, and has a wide range of databases that can be utilized, and has the advantage of searching more precisely and quickly through relationships between predefined concepts. In this paper, we propose a defense ontology as a method for effective data management and decision support. In order to judge the applicability and effectiveness of the actual system, we reconstructed the existing air force munitions situation management system as an ontology based system. It is a system constructed to strengthen management and control of logistics situation of commanders and practitioners by providing real - time information on maintenance and distribution situation as it becomes difficult to use complicated logistics information system with large amount of data. Although it is a method to take pre-specified necessary information from the existing logistics system and display it as a web page, it is also difficult to confirm this system except for a few specified items in advance, and it is also time-consuming to extend the additional function if necessary And it is a system composed of category type without search function. Therefore, it has a disadvantage that it can be easily utilized only when the system is well known as in the existing system. The ontology-based logistics situation management system is designed to provide the intuitive visualization of the complex information of the existing logistics information system through the ontology. In order to construct the logistics situation management system through the ontology, And the useful functions such as performance - based logistics support contract management and component dictionary are further identified and included in the ontology. In order to confirm whether the constructed ontology can be used for decision support, it is necessary to implement a meaningful analysis function such as calculation of the utilization rate of the aircraft, inquiry about performance-based military contract. Especially, in contrast to building ontology database in ontology study in the past, in this study, time series data which change value according to time such as the state of aircraft by date are constructed by ontology, and through the constructed ontology, It is confirmed that it is possible to calculate the utilization rate based on various criteria as well as the computable utilization rate. In addition, the data related to performance-based logistics contracts introduced as a new maintenance method of aircraft and other munitions can be inquired into various contents, and it is easy to calculate performance indexes used in performance-based logistics contract through reasoning and functions. Of course, we propose a new performance index that complements the limitations of the currently applied performance indicators, and calculate it through the ontology, confirming the possibility of using the constructed ontology. Finally, it is possible to calculate the failure rate or reliability of each component, including MTBF data of the selected fault-tolerant item based on the actual part consumption performance. The reliability of the mission and the reliability of the system are calculated. In order to confirm the usability of the constructed ontology-based logistics situation management system, the proposed system through the Technology Acceptance Model (TAM), which is a representative model for measuring the acceptability of the technology, is more useful and convenient than the existing system.

Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength (경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교)

  • Park, Choon-Keun;Hwang, Jang-Hoe;Ji, Chul;Lee, Jae Un;Sung, Jae Hoon;Choi, Seung-Jin;Lee, Sang-Won;Seybold, Eric;Park, Sung-Chan;Cho, Kyung-Suok;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1210-1219
    • /
    • 2001
  • Introduction : The purpose of this study was to analyze the safety, pullout strength and radiographic characteristics of unicortical and bicortical screws of cervical facet within cadaveric specimens and evaluate the influence of level of training on the positioning of these screws. Methods : Twenty-one cadavers, mean 78.9 years of age, underwent bilateral placement of 3.5mm AO lateral mass screw from C3-C6(n=168) using a slight variation of the Magerl technique. Intraoperative imaging was not used. The right side(unicortical) utilized only 14mm screws(effective length of 11mm) while on the left side to determine the length of the screw after the ventral cortex had been drilled. Three spine surgeons(attending, fellow, chief resident) with varying levels of spine training performed the procedure on seven cadavers each. All spines were harvested and lateral radiographs were taken. Individual cervical vertebrae were carefully dissected and then axial radiographs were taken. The screws were evaluated clinically and radiographically for their safety. Screws were graded clinically for their safety with respect to the spinal cord, facet joint, nerve root and vertebral artery. The grades consisted of the following categories : "satisfactory", "at risk" and "direct injury". Each screw was also graded according to its zone placement. Screw position was quantified by measuring a sagittal angle from the lateral radiograph and an axial angle from the axial radiograph. Pull-out force was determined for all screws using a material testing machine. Results : Dissection revealed that fifteen screws on the left side actually had only unicortical and not bicortical purchase as intended. The majority of screws(92.8%) were satisfactory in terms of safety. There were no injuries to the spinal cord. On the right side(unicortical), 98.9% of the screws were "satisfactory" and on the left side(bicortical) 68.1% were "satisfactory". There was a 5.8% incidence of direct arterial injury and a 17.4% incidence of direct nerve root injury with the bicortical screws. There were no "direct injuries" with the unicortical screws for the nerve root or vertebral artery. The unicortical screws had a 21.4% incidence of direct injury of the facet joint, while the bicortical screws had a 21.7% incidence. The majority of "direct injury" of bicortical screws were placed by the surgeon with the least experience. The performance of the resident surgeon was significantly different from the attending or fellow(p<0.05) in terms of safety of the nerve root and vertebral artery. The attending's performance was significantly better than the resident or fellow(p<0.05) in terms of safety of the facet joint. There was no relationship between the safety of a screw and its zone placement. The axial deviation angle measured $23.5{\pm}6.6$ degrees and $19.8{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The resident surgeon had a significantly lower angle than the attending or fellow(p<0.05). The sagittal angle measured $66.3{\pm}7.0$ degrees and $62.3{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The attending had a significantly lower sagittal angle than the fellow or resident(p<0.05). Thirty-three screws that entered the facet joint were tested for pull-out strength but excluded from the data because they were not lateral mass screws per-se and had deviated substantially from the intended final trajectory. The mean pull-out force for all screws was $542.9{\pm}296.6N$. There was no statistically significant difference between the pull-out force for unicortical($519.9{\pm}286.9N$) and bicortical($565.2{\pm}306N$) screws. There was no significant difference in pull-out strengths with respect to zone placement. Conclusion : It is our belief that the risk associated with bicortical purchase mandates formal spine training if it is to be done safely and accurately. Unicortical screws are safer regardless of level of training. It is apparent that 14mm lateral mass screws placed in a supero-lateral trajectory in the adult cervical spine provide an equivalent strength with a much lower risk of injury than the longer bicortical screws placed in a similar orientation.

  • PDF

A study on physical examination of middle school students (중학교 체질검사 실태에 관한 연구)

  • Park, Sung-Hee
    • Journal of the Korean Society of School Health
    • /
    • v.14 no.1
    • /
    • pp.131-143
    • /
    • 2001
  • The primary aim of this dissertation is to contribute to the improvement of methods in physical examination by providing quality information for the current school system and advice for improving status. Present status, controversial points and possible remedies in physical examination were analyzed on a frequency and percentage basis. An $x^2$-test was used to verify the statistics between the results from the examination and each variable. In case of multiple categories of variables, an $x^2$ cs was adopted. Chronological data as well as both total and sampling physical examination data verified the statistics using an $x^2$-test. This thesis is based both on the data from middle school health care specialists in Gyunggi Province and on the analysis of physical examinations reported from local schools to the municipal education agency from 1997 to 1999. The results of the study are as follows: First, according to the survey, only 29.0% of the total schools had their school doctors examine all the students while most of the educational institutions failed to implement the whole process of physical examination on the list. It also turned out that the more students the schools have, the lower the rate of implementation of physical examination by school doctors(p=0.014). Second, the average time a school doctor spends for checkup turned out to be approximately 1.7 minutes per student This means that the quality of the physical examination is not guaranteed in the process. Third, 47.7% of those surveryed say that a dental examination was performed, each taking 21.24 seconds on average. In addition, it shows that some 31.5% wanted to have a task force team for dental checkups at the local health center. Given the fact that dental caries among students is progressively on the rise, the dental health centers that are now set up in some elementary schools should be expanded to cover the whole educational institution in order to raise awareness of the importance of dental care. Fourth, 48.5% of those surveyed say that a comprehensive physical examination should be adopted to promote the health of high schoolers. Since it takes a lot of public funds to implement a comprehensive method, it is essential to make sure that in-depth studies should be based on the frequency and methods of physical examination. Fifth, regarding such diseases among 3rd year middle school students in 1999, statistics shows that there was a slight difference in the prevalence rate of color blindness, and allergic diseases for male students ; and color blindness, hearing disturbance and allergic disease for female students. For those items, however, it is too little to say that there is a significant difference and accordingly it is assumed to be a problem of the measuring process. Sixth, the result of analysis on the sample physical examination and the total physical examination of the year 1999 shows as follows: For male students in the 3rd year of middle school, a slight difference appeared to those students in 11 items including eye problems and eye disease, otitis media, tonsillar hypertrophy, spinal shape, respiratory urinary allergic disease and other abnormal diseases(p<0.05). Particularly, the prevalence rate between students with and without disease was shown to be two times more in the following: eye problems, otitis media, tonsill hypertrophy, allergic diseases, etc. For female students in the 3rd year, prevalence rate showed little difference in 14 items(p<0.05). For items including eye problem, otitis media, tonsill hypertrophy, allergic disease, etc. it was shown that the rate was two times more between students with and without diseases. Physical examinations under the current school system are not producing any fundamental results for the health of the students. Methods and results are not trustworthy. Accordingly, a drastic overhaul of the current practices is needed in frequency, methods and items on the list in order to promote the health of the students. Cost-benefit studies as well as political considerations to ensure the development of efficient methods for physical examination are urgently needed at this moment.

  • PDF

A study on accuracy and application of the implant torque controller used in dental clinic (임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태)

  • Joo, Young-Hun;Lee, Jin-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.197-205
    • /
    • 2011
  • Purpose: This study was to evaluate the accuracy of the implant torque controller used in dental clinics and to investigate whether it was applied appropriately. Materials and methods: Fifty dentists who work in dental clinics were enrolled in this study. Dental (implant) practice career, experience frequency of implant screw loosening and fracture, education of implant torque controller application and infection control methods were included in the survey. 25 Ncm and 30 Ncm of the tightening torque applied to the implant screw were measured by 50 clinicians. After measuring the torque value by using the torque controller, the torque mean according to where education about the implant torque controller was received was analyzed with independent t-test at the significance level of 0.05. Results: The torque controller used in private dental clinics showed 4.78% error ratio. When 50 dentists applied 25 Ncm to the implant screw was $29.0{\pm}8.4$ Ncm, and that in 30 Ncm was $34.3{\pm}9.1$ Ncm. Statistical significance was found between the group that was educated about implant torque application and the group that was not educated. Conclusion: During the prosthodontic treatment with implant, there was difference between actual applied torsion force and the amount torque controller indicated. Clinicians have to not only be well-informed about the accurate usage method of the torque controller, but also keep and manage the torque controller so as to maintain continuous and accurate torque values. Through this, it is considered to achieve clinical results to minimize problems of screw loosening or fracture.