• Title/Summary/Keyword: Force measurement

Search Result 1,614, Processing Time 0.025 seconds

Analysis and Test for Turn-buckle of Capacity for Measuring Tensile Force (용량별 인장력 측정용 턴버클의 해석 및 실험)

  • Shin, Kyung-Jae;Lee, Swoo-Heon;Lee, Hee-Du
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.715-724
    • /
    • 2011
  • A turn buckle inserted between tension members that sustain the structural loads in a suspension structure system is a device that is capable of adjusting the tensile force. The tension member is an important element of a tension structure, but no simple and economical method of measuring a tensile force applied to members has been proposed yet. Thus, a turn buckle for measuring the tensile force in a tension member was developed in this study. The turn buckles of the measurement limit loads of 100kN, 200kN, and 300kN were tested through a theoretical analysis and a finite element analysis. There was no significant difference in the results of the theoretical analysis, FEA, and the test. In addition, the ultimate strength of the turn buckle using FEA showed that a new turn buckle is sufficiently safe to use even when there is a five-times overload in the measurement limit load.

An Analysis of Tribological Properties of Metal Interlayered DLC Films Prepared by PECVD Method (PECVD로 증착된 금속층을 포함하는 DLC 박막의 기계적 특성 분석)

  • Jeon, Young-Sook;Choi, Won-Seok;Hong, Byung-You
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.7
    • /
    • pp.631-635
    • /
    • 2006
  • The properties of metal interlayered DLC films between the Si substrate and the DLC films were studied. DC magnetron sputtering method has been used to deposit intermediate layers of metals. And RF-PECVD method has been employed to synthesize DLC onto substrates of the silicon and metal layers. After we used metal Inter-layers, such as chromium, nickel, titanium and we studied tribological properties of the DLC films. The thickness of films were observed by field emission scanning electron microscope (FE-SEM). Also the surface morphology of the films were observed by an atomic force microscope (AFM). The crystallographic properties of the films were analyzed with X-ray diffraction (XRD), the friction coefficients were investigated by AFM in friction force microscope (FFM) mode. Tribological performances of the films were estimated by nano-indenter, stress tester measurement.

A Development of Measurement System for Diathesis-Diagnosis (체질 진단을 위한 센서 시스템의 개발)

  • Jung, Yong-Rae;Kim, Seong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.260-263
    • /
    • 2001
  • This paper is to develop the sensing system for opening-force measurement such as O-Ring muscular meridian. We designed to overcome the functional limit that the conventional force-sensor can measure just the closing-force. Therefore, the new sensor can meet a variety of application as well as O-Ring test. The structure of the new sensor is an actuator-type system using an electromagnet. That is made up of mechanical system, electromagnet, current transformer and computer interface circuit. Driving software and user interface program of the new sensor system also is explained in this paper.

  • PDF

Physical Properties of Diamond-like Carbon Thin Films Prepared by a Microwave Plasma-Enhanced Chemical Vapor Deposition (마이크로웨이브 화학기상증착법으로 성장된 다이아몬드상 카본박막의 물리적인 특성연구)

  • Choi, Won-Seok;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.791-794
    • /
    • 2003
  • DLC thin films were prepared by microwave plasma-enhanced chemical vapor deposition method on silicon substrates using methane ($CH_4$) and hydrogen ($H_2$) gas mixture. The negative DC bias ($-450V{\sim}-550V$) was applied to enhance the adhesion between the film and the substrate. The films were characterized by Raman spectrometer. The surface morphology was observed by an atomic force microscope (AFM). And also, the friction coefficients were investigated by AFM in friction force microscope (FFM) mode, which were compared with the pin-on-disc (POD) measurement.

  • PDF

Physical Properties of Diamond-like Carbon Thin Films Prepared by a Microwave Plasma-Enhanced Chemical Vapor Deposition (마이크로웨이브 화학기상증착법으로 성장된 다이아몬드상 카본박막의 물리적인 특성연구)

  • Choi, Won-Seok;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.842-845
    • /
    • 2003
  • DLC thin films were prepared by microwave plasma-enhanced chemical vapor deposition method on silicon substrates using methane ($CH_4$) and hydrogen ($H_2$) gas mixture. The negative DC bias ($-450V{\sim}-550V$) was applied to enhance the adhesion between the film and the substrate. The films were characterized by Raman spectrometer. The surface morphology was observed by an atomic force microscope (AFM). And also, the friction coefficients were investigated by AFM in friction force microscope (FFM) mode, which were compared with the pin-on-disc (POD) measurement.

  • PDF

Friction Characteristics of the Piston-Ring Assembly Varying Engine Operation Coditions (운전조건변화에 따른 피스톤-링 결합체 마찰특성)

  • 윤정의;김승수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.6
    • /
    • pp.1510-1519
    • /
    • 1994
  • It is important to understand the friction characteristics between piston-ring assembly and cylinder wall for the friction loss reduction as well as the solution of problem such as scuffing wear and oil consumption. A new system was developed for the piston-ring assembly friction force measurement. This system was applied to the friction force measurement to find its functional relationship with variables such as engine speed, oil viscosity, and engine load. The friction mean effective pressure(fmep) was found to have a linear relationship with$(\vpsilon{U})^{0.42}$ under motering and with$(\vpsilon{U})^{0.45}$ under firing operations, where $\vpsilon$ is the kinematic oil viscosity and U is mean piston speed.

Air Flow Sensor with Corrugation Structure for Low Air Velocity Detection (주름구조를 적용한 저속 유속 센서)

  • Choi, Dae-Keun;Lee, Sang-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.393-399
    • /
    • 2011
  • In this paper, we designed and fabricated the novel air flow sensor using air drag force, which can be applied to the low air flow detection. To measure the low air flow, we should enlarge the air drag force and the output signal at the given air flow. The paddle structure is applied to the device, and the device is vertically located against the air flow to magnify the air drag force. We also adapt the corrugation structure to improve the output signals on the given air velocity. The device structure is made up of the silicon nitride layer and the output signal is measured with the piezoresistive layer. The output signals from the corrugated device show the better measurement sensitivity and the response time than that of flat one. The repeated measurement also shows the stabilized signals.

Structural Strength Analysis and Static Load Test of a Wheelset of Korean High Speed Rail for Measuring Whee/Rail Force (한국형 고속철도차량의 차륜/궤도 작용력 측정을 위한 윤축의 구조강도 해석 및 정하중 시험)

  • 전응식;함영삼;허현무;강부병
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.898-903
    • /
    • 2002
  • The railroad is a means of large transportation which has many talents such as a safety and a regularity. That is a results from various confidential performance tests and evaluations of the system. The railroad system consist of various subsystems - vehicle, power supply, signal, communications, track structures, operations, etc. Among them, as an item of safety evaluation there is a measurement of wheel/rail force, so called a measurement of derailment coefficient. This is a very important item because a derailment of a train will bring about a big accident. Especially it is more inportant in high speed rail of which operation speed is over two times as fast as existing rail. In this paper, it is introduced to preprocess the wheelset for measuring wheel/rail force of high speed rail, such as to treat a measuring wheelset, its finite element analysis, adhesion of strain gauges and static load test.

  • PDF

Protective System from Medical Needle-sticks. Part II: Evaluation of Woven Structures and Bifid Needles

  • Seyam, Abdelfattah M.;Turner, LaDawnya C.;Banks-Lee, Pamela
    • Fibers and Polymers
    • /
    • v.4 no.3
    • /
    • pp.129-134
    • /
    • 2003
  • We have shown in Part I [1] of this study that medical needle-stick injuries are causing serious health problems to healthcare personnel and other professionals that require the attention of healthcare and textile researchers to develop new protective systems. Responding to such need, a needle force measurement device that is capable of measuring dynamic forces experienced by medical needles during needle penetration through protective articles was developed and described in part I. This paper reports the results of evaluation of protective woven fabrics from high performance fibers and standard and bifid medical needles using the force measurement system. The woven fabrics varied in cover factor, number of layers, and orientation angle. Standard and bifid needles with different gap widths were used to evaluate the resistance of the fabric to needle penetration.

A Study on the Grinding Characteristics for Various Grinding Wheels in the Cylindrical Grinding (원통연삭시 연삭휠의 종류에 따른 연삭 가공특성에 관한 연구)

  • Lee, Choong-Seok;Chae, Seung-Su;Kim, Taeck-Su;Lee, Sang-Min;Park, Hwi-Keun;Lee, Jong-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.1
    • /
    • pp.3-8
    • /
    • 2008
  • This paper reports some experimental results of cylindrical external grinding using CBN wheels. Many experimental studies for surface grinding have been done, but not for the cylindrical grinding due to the difficulty of grinding force measurement. In this paper a new experimental device has been proposed for the grinding force measurement in cylindrical grinding. The cylindrical grinding experiments were carried out at various grinding conditions with several CBN grinding wheels. The experimental results indicate that the CBN wheels with smaller grains result in the higher grinding forces in both SCM415 and STD11 workpieces. The grinding forces of all wheels were proportional to the infeed speeds and the difference of each wheels was prominent at high infeed speed for SCM415.

  • PDF