• Title/Summary/Keyword: Force Standards

Search Result 334, Processing Time 0.024 seconds

An Exploratory Study on the Possibility of Quantitative Measurement during Abdominal Examinations - A Preliminary Study on the Development of a Diagnostic Device for Abdominal Examinations (한의복진법의 정량화를 위한 탐색적 임상연구 - 한의 복진기기 개발을 위한 예비 연구 -)

  • Lee, Jae-hong;Kim, Sang-jin;Ko, Seok-jae;Park, Jae-woo
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.6
    • /
    • pp.940-948
    • /
    • 2016
  • Objectives: This exploratory trial evaluated the possibility of quantitatively measuring several aspects during the "abdominal examination" of traditional Korean medicine. The main results of this study will be used to develop a new diagnostic device for abdominal examinations. Methods: Fifteen healthy volunteers were recruited for this study. Three certified Korean medical doctors assessed the existence of pressure pain, the elasticity of the abdominal muscle, and the tonus at CV12 as gold standards. Then, 2 well-trained investigators measured the pressure pain threshold (PPT), the indentation depth of a bar, and repelling force by pressing CV12. Each investigator measured the above 3 variables 2 times at 1 min intervals using a modified digital algometer. Reliability and validity tests of the 3 variables were performed. Results: There were statistically significant coefficients of intraclass correlation on the 3 variables both between and within the investigators (P<0.001). Also, PPT and repelling force showed statistically significant high sensitivity and specificity in a ROC curve. However, the indentation depth of the bar presented relatively low sensitivity. Conclusions: This new diagnostic method using a modified digital algometer could be a useful tool for quantitative measurement in "abdominal examinations". However, future rigorous clinical studies with a large population will be needed for the verification of its usefulness.

Analysis on Specific Cutting Resistance Variation by Tool Angles Based on a Concept of Representative Stres (겉보기 응력 개념에 기반한 공구각에 따른 비절삭저항 변화 분석)

  • Jeon, Eun-Chae;Choi, Hwan-Jin;Lee, Kyu-Min;Lee, Yun-Hee;Je, Tae-Jin;Kim, Jeong-Hwan;Choi, Doo-Sun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.64-72
    • /
    • 2014
  • In the past, prism patterns have been linear triangular shapeswith a $90^{\circ}$ angle; however, new micro prism patterns having acute angles or obtuse angles have recently been the subject of demandin the display, lighting and photovoltaic industries. Micro-cutting experiments for micro-prism patterns having $60^{\circ}$, $90^{\circ}$, and $120^{\circ}$ angles on an electroplated Ni mold were performed and it was found in this study that the specific cutting resistance increased with a decrease in the tool angles (prism pattern angles). The cause of this variation had been thought to be the increase of the ploughing force due to tip rounding and the friction force due to the edge effect. However, the depth of the cut was large enough that it was possible to neglect these effects. Therefore, this study introduced the concept of representative stress of indentation. The measured stress was varied according to the indentation depth eventhoughthetestedspecimenswereidentical ; the varied stress was termed the representative stress. According to indentation theory, the strain that the Ni mold experienced increased with a decrease in the tool angle. Based on the stress-strain relationship, higher strain means higher stress and higher specific cutting resistance. Therefore, the specific cutting resistance was higher at smaller tool angles that had higher strain and stress.

Assessment of ASCE 7-10 for wind effects on low-rise wood frame buildings with database-assisted design methodology

  • He, Jing;Pan, Fang;Cai, C.S.
    • Wind and Structures
    • /
    • v.27 no.3
    • /
    • pp.163-173
    • /
    • 2018
  • The design wind pressure for low-rise buildings in the ASCE 7-10 is defined by procedures that are categorized into the Main Wind Force-Resisting System (MWFRS) and the Components and Cladding (C&C). Some of these procedures were originally developed based on steel portal frames of industrial buildings, while the residential structures are a completely different structural system, most of which are designed as low-rise light-frame wood constructions. The purpose of this study is to discuss the rationality (or irrationality) of the extension of the wind loads calculated by the ASCE 7-10 to the light-frame wood residential buildings that represent the most vulnerable structures under extreme wind conditions. To serve this purpose, the same approach as used in the development of Chapter 28 of the ASCE 7-10 that envelops peak responses is adopted in the present study. Database-assisted design (DAD) methodology is used by applying the dynamic wind loads from Louisiana State University (LSU) database on a typical residential building model to assess the applicability of the standard by comparing the induced responses. Rather than the postulated critical member demands on the industrial building such as the bending moments at the knee, the maximum values at the critical points for wood frame buildings under wind loads are used as indicators for the comparison. Then, the critical members are identified through these indicators in terms of the displacement or the uplift force at connections and roof envelope. As a result, some situations for each of the ASCE 7 procedures yielding unconservative wind loads on the typical low-rise residential building are identified.

A study on the strategy of concerned parties with regard to the performance standards and implementation schedule of ballast water treatment systems (평형수처리장치 성능기준 및 시행시기 차이에 의한 관련 당사자들의 대응전략 연구)

  • Kim, Kyong-Min;Kim, Hoi-Jun;Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.325-332
    • /
    • 2014
  • In installing ballast water treatment system, the cost of the system is high and many technical aspects are to be considered and also it takes significant time to retro-fitting on the existing ships. In addition, in the current circumstance which the Ballast Water Management Convention has not been entered into force, the 28th IMO Assembly adopted a resolution to mediate the implementation schedule of the treatment systems. In the mean time, California State and New York State have declared more stringent discharge requirements of ballast water and are planning to implement them earlier than the schedule of the Convention. In these circumstances, the implication in the difference between ballast water treatment system manufacturers and ship owners need to be considered. In this study, through the review on the considerations when installing the system onboard, stringent requirements of United States of America, and determent or mediated implementation schedules of Convention and California and New York States, the author would like to suggest the strategy of concerned parties for anticipated entrry into force of the Convention and implementation of the stringent requirements of United States of America.

Mercury Emission Control in Japan

  • Takiguchi, Hiroaki;Tamura, Tomonori
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.37-46
    • /
    • 2018
  • The Minamata Convention on Mercury entered into force on August 16, 2017. It requires Parties to the Convention to control and, where feasible, reduce mercury emissions from the listed sources. To implement the Convention, Japan amended the Air Pollution Control Law and added clauses that force operators to control their mercury emissions below emission limit values (ELVs). The ELVs have been established separately for new and existing sources, targeting the source categories listed in the Convention: coal-fired boilers, smelting and roasting processes used in the production of non-ferrous metals (lead, zinc, copper and industrial gold), waste incineration facilities and cement clinker production facilities. The factors used to establish the ELVs include the present state of mercury emissions from the targeted categories as well as the mercury content in fuels and materials, best available techniques (BATs) and best environmental practices (BEPs) to control and reduce mercury emissions and ELVs or equivalent standards to control mercury emissions in other countries. In this regard, extensive data on mercury emissions from flue gas and the mercury content of fuels and materials were collected and analyzed. The established ELVs range from $8{\mu}g/Nm^3$ for new coal-fired boilers to $400{\mu}g/Nm^3$ for existing secondary smelting processes used in the production of copper, lead and zinc. This paper illustrates the ELVs for the targeted source categories, explaining the rationales and approaches used to set the values. The amended Law is to be enforced on April 1, 2018. From future perspectives, checks of the material flow of mercury, following up on the state of compliance, review of the ELVs and of the measurement and monitoring methods have been noted as important issues.

Enhancing the Applicability and Improvement Direction of Integrated Environmental Permit System (통합환경허가시스템의 활용도 제고 및 개선방향)

  • Park, Jae Hong;Shin, Su Jeong;Lee, Dae Gyun
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.339-345
    • /
    • 2018
  • The integrated environmental permit system is currently in operation online. It carries out various functions of postmanagement such as the submission of annual reports containing operations management data onto integrated management workplaces, the operation and management of emission facilities and prevention facilities, and the disclosure of information on the integrated permission. On the other hand, the integrated environmental permit system needs to perform various roles in order to stably manage and smoothly perform the permitting work. It is necessary to utilize this system to establish policies by using diverse operations management data onto integrated management workplaces collected in the integrated environmental permit system. This system can also play a role in improving the post-management system and user convenience after the permission review and approval processes. The integrated environmental permit system can be effectively used to set up the BAT-AEL because it collects all of the cross-media data and identifies the overall status of the workplace. In order to establish a post management system after the approval, it is necessary to provide performance management and performance evaluation functions as conditions of the permit after approval. In addition, a variety of support functions should be provided to enable the permission authority and the environmental expert examination agency to facilitate the review of permits. It will be necessary to provide an evaluation system and a proactive diagnostic function to determine whether permission conditions and permit emission standards will change in the future. Also, it is important to adopt an information exchange platform that can be used to collect the status data onto the workplaces; the platform can also be used as an information exchange site for technical working groups (TWG), and for collecting field experts' opinions.

The Joining Quality of High Strength Bolt, Nut and Washer Set (A490) in the Extreme Conditions (극한 상태에서 A490 고장력 볼트 세트의 체결 품질 연구)

  • Suk, Han-Gil;Cho, In-Seup;Hong, Hyeon-Sun
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.1
    • /
    • pp.21-25
    • /
    • 2011
  • This test focuses on the correlation between the lubrication, ductility and strength through the change of nut lubricant which decides joining angle for A490 bolt sets required in the AASHTO (American Association of State Highway & Transportation Officials). Because the lubrication of high tension bolt, nut, washer sets becomes an important factor to ductility and joining load, the quality improvement is required for improving reliability and securing enough lubrication of maker and user. This study examines the quality characteristics required in the specification through tests because only this standard specifies joining quality in the extreme conditions (as much about two times of the joining angle on site as normal condition). Moreover, this study is limited to the test on joining axial force required in the AASHTO for the three nut lubrication conditions of A490 bolt set. It is concluded that the nuts should be coated or waxed enough for the improvement of the joining axial force and ductility of bolts required in the standards. It is shown that in the case of plain high tension bolt sets, a rust preventing lubricative oil shall be applied and the torque coefficient value for A490 bolt sets should be maintained below 0.175.

An Experimental Study on the Ventilation Characteristics of a Wind-Turbine Natural Ventilator According to the Outdoor-Wind Velocity and the Indoor/Outdoor-Temperature Difference (윈드터빈 자연환기 장치의 외기풍속 및 온도차에 따른 환기특성에 관한 실험연구)

  • Han, Dong-Hun;Kim, Yeong-Sik;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.175-184
    • /
    • 2017
  • With the improvement of living standards, the ventilation for the mitigation of indoor or outdoor air-pollution problems has recently attracted a lot of attention. Consequently, the ventilation for the supply of outdoor fresh air into a room is treated as an important building-design factor. The ventilation is generally divided into the forced and natural types; here, the former can control the ventilation rate by using mechanical devices, but it has the disadvantages of the equipment costs, maintenance costs, and noise generation, while the latter is applied to most workshops due to the absence of noise and the low installation and maintenance costs. In this experimental study, the ventilation performance of a typical rotating-type natural ventilator, which is called a "wind turbine," was investigated with the outdoor-wind velocity and the indoor/outdoor-temperature difference. From the experiment results, it was confirmed that the temperature difference of $10^{\circ}C$ corresponds to the ventilation driving force with an outdoor-wind velocity of 1.0 m/s. Additionally, the intake-opening area of a building also exerts a great effect on the ventilation rates.

Nanoprobing Charge Transport Properties of Strained and Indented Topological Insulator

  • Hwang, Jin Heui;Kwon, Sangku;Park, Joonbum;Lee, Jhinhwan;Kim, Jun Sung;Lyeo, Ho-Ki;Park, Jeong Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.128.1-128.1
    • /
    • 2013
  • We investigated the correlation between electrical transport and mechanical stress in $Bi_2Te_2Se$ by using a conductive probe atomic force microscopy in an ultra-high vacuum environment. Uniform distribution of measured friction and current were observed over a single quintuple layer terrace, which is an indication of the uniform chemical composition of the surface. By measuring the charge transport of $Bi_2Te_2Se$ surface as a function of the load applied by a tip to the sample, we found that the current density varies with applied load. The variation of current density was explained in light of the combined effect of the changes in the in-plane conductance and spin-orbit coupling that were theoretically predicted. We suppose that the local density of states is modified by tip-induced strain, but topological phase still remains. We exposed a clean topological insulator surface by tip-induced indentation. The surface conductance on the indented $Bi_2Te_2Se$ surface was studied, and the role of surface oxide on the surface conductance is discussed.

  • PDF

Evaluation of Mechanical Joint Structural Performance through Actual Performance Testing of PC Connections (PC 접합부의 실물 성능실험을 통한 기계식이음 구조성능 평가)

  • Kim, Jae Young;Kim, Yong Nam;Seo, Min Jung;Kim, Beom Jin;Kim, Sung Jig;Lee, Kihak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.129-139
    • /
    • 2024
  • In this study, the SBC system, a new mechanical joint method, was developed to improve the constructability of precast concrete (PC) beam-column connections. The reliability of the finite element analysis model was verified through the comparison of experimental results and FEM analysis results. Recently, the intermediate moment frame, a seismic force resistance system, has served as a ramen structure that resists seismic force through beams and columns and has few load-bearing walls, so it is increasingly being applied to PC warehouses and PC factories with high loads and long spans. However, looking at the existing PC beam-column anchorage details, the wire, strand, and lower main bar are overlapped with the anchorage rebar at the end, so they do not satisfy the joint and anchorage requirements for reinforcing bars (KDS 41 17 00 9.3). Therefore, a mechanical joint method (SBC) was developed to meet the relevant standards and improve constructability. Tensile and bending experiments were conducted to examine structural performance, and a finite element analysis model was created. The load-displacement curve and failure pattern confirmed that both the experimental and analysis results were similar, and it was verified that a reliable finite element analysis model was built. In addition, bending tests showed that the larger the thickness of the bolt joint surface of the SBC, the better its structural performance. It was also determined that the system could improve energy dissipation ability and ductility through buckling and yielding occurring in the SBC.