• 제목/요약/키워드: Force Evaluation

검색결과 2,063건 처리시간 0.032초

초음파모터를 이용한 역감장치에 관한 연구 (A Study on Force-Reflecting Interface using Ultrasonic Motros)

  • 강원찬;김대현;김영동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.123-128
    • /
    • 1998
  • This paper describes the evaluation of a force-reflecting interface with ultrasonic motors(USMs). The force-reflecting interface allows a human to feel object within virtual environment. To effectively display the mechanical impedance of the human hand we need a haptic device with specific characteristics, such as low inertia, almost zero friction and very high stiffness. USMs have attracted considerable attention as the actuator satisfied these conditions. USMs combine features such as high driving torque at low rotational speed, high holding torque and fast response therefore we studied two degree of freedom force-reflecting haptic system.

  • PDF

Crystal Geometry Optimization of β-Lactam Antibiotics Using MMFF Parameters

  • 원영도
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권10호
    • /
    • pp.944-952
    • /
    • 1995
  • A generic force field approach has been applied to geometry optimization of penam and cephem crystals. The crystalline state energy and force evaluation with the universal force field (MMFF: Merck Molecular Force Field) results in good agreements with the crystallographic data. Bond lengths are usually correct to within 0.02 Å and bond angles usually to within 2.5°. The conformation of the β-lactam bicyclic rings in the crystal environment is also well reproduced. The results thus demonstrate the applicability of MMFF to modeling of newer molecular constructs in condensed phase.

2축 힘/모멘트센서를 이용한 원통형 손가락 힘측정장치 개발 및 특성평가 (Development of Cylindrical-type Finger Force Measuring System Using Two-axis Force/Moment Sensor and its Characteristic Evaluation)

  • 김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제17권5호
    • /
    • pp.484-489
    • /
    • 2011
  • Some patients can't use their hands because of inherent and acquired paralysis of their fingers. Their fingers can recover with rehabilitative training, and the extent of rehabilitation can be judged by grasping a cylindrical-object with their fingers. At present, the cylindrical-object used in hospitals is only a cylinder which cannot measure grasping force of the fingers. Therefore, doctors must judge the extent of rehabilitation by watching patients' fingers as they grasp the cylinder. A cylindrical-type finger force measuring system which can measure the grasping force of patients' fingers should be developed. This paper looks at the development of a cylindrical-type finger force measuring system with two-axis force/moment sensor which can measure grasping force. The two-axis force/moment sensor was designed and fabricated, and the high-speed force measuring device was designed and manufactured by using DSP (digital signal processing). Also, cylindrical-type finger force measuring system was developed using the developed two-axis force/moment sensor and the high-speed force measuring device, and the grasping force tests of men were performed using the developed system. The tests confirm that the average finger forces of right and left hands for men were about 186N and 172N respectively.

지면반력분석기를 이용한 골프 스윙의 분석 평가 방법 (A Method for Analyzing and Evaluating the Golf Swing Using the Force Platform Data)

  • 성낙준
    • 한국운동역학회지
    • /
    • 제20권2호
    • /
    • pp.213-219
    • /
    • 2010
  • The purpose of this study is developing a method to analyze and evaluate a golf swing motion using the ground reaction force (GRF) data. Proper weight shifting is essential for a successful shot in golf swing and this could be evaluated by means of the forces between the feet and ground. GRF during the swing were measured from 15 low-handicapped male golfers including professionals. Four clubs(driver, iron 3, iron 5, and iron 7) were selected to analyze the differences due to different characteristics of club. Swings of each subject were taken using a high speed video camera and GRF data were taken simultaneously by two AMTI force platforms. To simplify the GRF data, forces of the three major component of GRF(vertical, lateral, anterior-posterior force) at 10 predefined temporal events for each trial were selected and the mean of each event were calculated and evaluated. Analyzed vertical GRF (VGRF) data could be divided into two different styles, one-legged and two legged. One-legged style shows good weight transfer to the target leg and most of the previous study shows this style as a typical pattern of good players. Therefore the data from the iron 5 swing obtained from 10 one-legged style golfers are provided as criteria for the evaluation of a swing.

가상환경에서의 냉장고 도어 개폐의 현실감 평가 (Presence evaluation of virtual refrigerator doors in opening and closing)

  • 박재희;이인석;김진욱;고희동
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2003년도 춘계학술대회 논문집
    • /
    • pp.90-93
    • /
    • 2003
  • This study aims to validate the effectiveness of VE system with an arm-master in the evaluation of virtual prototype. A virtual kitchen with a refrigerator was presented in a CAVE system. Subjects put in and pull out virtual objects by using the arm-master. Twelve subjects participated in six experimental conditions: three types of refrigerator door grips and two reaction forces. After each trial, subjects evaluated a virtual refrigerator in terms of easiness of operation, similarity in force, presence etc. The results show the subjects preferred vertical grip than horizontal grip and light reaction force than heavy one. The VE system with the arm-master will be very helpful in the design evaluation of virtual prototypes.

  • PDF

방수재료의 거동대응성능 시험시 비 구속조건에서의 구조물 거동 대응성능 평가의 한계와 향후 개선 방안 제안 (Limitations of Structural Behavior Response Performance Evaluation for Waterproofing Materials Under Non-Constrained Conditions and Suggestions for Future Improvement Measures)

  • 안기원;오규환;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.212-213
    • /
    • 2021
  • As structure and the waterproofing material are compressed through the backfilling process after the waterproofing material is installed on the underground structure at the actual site, there is a difference between the behavioral response force of the waterproofing material in the compressed state and the behavioral response force in the non-constrained state. In this regard, we will analyze the limitations of the current structural behavioral response evaluation and suggest an improvement plan so that the future test and evaluation environment can be evaluated under conditions similar to the field.

  • PDF

다기능 재활운동을 위한 힘 센서가 없는 상지 재활 로봇의 힘 제어 (Sensorless Force Control with Observer for Multi-functional Upper Limb Rehabilitation Robot)

  • 최정현;오세훈;안진웅
    • 로봇학회논문지
    • /
    • 제12권3호
    • /
    • pp.356-364
    • /
    • 2017
  • This paper presents a force control based on the observer without taking any force or torque measurement from the robot which allows realizing more stable and robust human robot interaction for the developed multi-functional upper limb rehabilitation robot. The robot has four functional training modes which can be classified by the human robot interaction types: passive, active, assistive, and resistive mode. The proposed observer consists of internal disturbance observer and external force observer for distinctive performance evaluation. Since four training modes can be quantitatively identified as impedance variation, position-based impedance control with feedback and feedforward controller was applied to the assistive training mode. The results showed that the proposed sensorless observer estimated cleaner and more accurate force compared to the force sensor and the impedance controller embedded with the proposed observer completed the assistive training mode safely and properly.

고정밀 전기식 힘측정기의 불확도평가 절차 및 응용 (Procedure for Uncertainty Evaluation of a Precision Electric Force Measuring Device and Its Application)

  • 김갑순;강대임
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.161-167
    • /
    • 1999
  • This paper describes the calibration method and the calculation equations of expanded uncertainty for a precision electric force measuring device. The calibration of the electric force measuring device is performed three times (0 ${\circ}$(first time), $120{\circ}$(second time), $240{\circ}$(third time)) at each calibration point. It is usually selected ten points from zero load to rated load of the electric force measuring device. The expanded uncertainty is calculated by combining A type standard uncertainty and B type standard uncertainty. The calibration method and the calculation equations of expanded uncertainty can be widely used in the calibration of the precision electric force measuring device.

  • PDF

바이패스홀을 특징으로 하는 승용차용 MR 댐퍼의 성능 평가 (Performance Evaluation on an MR Damper Featuring Bypass Hole for Passenger Vehicle)

  • 오종석;신도균;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.998-999
    • /
    • 2014
  • This paper proposes a method for damping force modeling of magnetorheological (MR) damper featuring bypass hole. After describing configuration and of the MR damper, a damping force modeling of the MR damper is derived based on Bingham model of MR fluid. MR damper consists of piston, accumulator, gap, bypass hole and coil. Damping force is consists of spring force induced by accumulator, viscous force induced at gap and bypass hole, and controllable force induced at gap.

  • PDF