• 제목/요약/키워드: Force Distribution

검색결과 1,957건 처리시간 0.035초

유한요소법을 이용한 고분자전해질연료전지 기체확산층의 응력분포 연구 (The Stress Distribution Analysis of PEMFC GDL using FEM)

  • 김철현;손영준;박구곤;김민진;이종욱;김창수;최유송;조성백
    • 한국수소및신에너지학회논문집
    • /
    • 제23권5호
    • /
    • pp.468-475
    • /
    • 2012
  • A proper stacking force and assembly are important to the performance of fuel cell. Improper assembly pressure may lead to leakage of fuels and high interfacial contact resistance, excessive assembly pressure may result in damage to the gas diffusion layer and other components. The pressure distribution of gas diffusion layer is important to make interfacial contact resistance less for stack performance. To analyze the influence of design parameter factors for pressure distribution, and to optimize stack design, DOE (Design of Experiment) was used for polymer electrolyte membrane fuel cell stack pressure test. As commonly known, the higher clamping force improves the fuel cell stack performance. However, non-uniformity of stress distribution is also increased. It shows that optimization between clamping force and stress distribution is needed for well designed structure of fuel cell stack. In this study, stack design optimization method is suggested by using FEM (Finite Element Methode) and DOE for light-weighted fuel cell stack.

대형 뉴메틱케이슨 강성기초의 접지압분포 (Distribution of Ground Contact Pressure under Rigid Foundation of Large Pneumatic Caisson)

  • 홍원표;여규권
    • 대한토목학회논문집
    • /
    • 제28권2C호
    • /
    • pp.105-115
    • /
    • 2008
  • 다양한 지층에 설치된 대형 뉴메틱케이슨의 강성기초에 작용하는 접지압분포를 파악하기 위하여 영종대교하부기초로 채택된 뉴메틱케이슨 시공시 실시한 현장계측자료를 분석하였다. 뉴메틱케이슨의 침설시 케이슨의 하부 접지면에 케이슨의 침설에 저항하여 저항력이 작용할 것이다. 이 저항력을 뉴메틱케이슨 기초저면 모서리에 설치한 반압계로 측정할 수 있었다. 그리고 이 저항력측정기록을 이용하여 접지압을 산정하였다. 측정기록의 분석결과 기반암구간에서 뉴메틱케이슨기초에 작용하는 접지압분포는 아래로 볼록한 형상의 접지압분포를 보이는 반면에 해성퇴적층과 풍화암층에서의 접지압분포는 위로 볼록한 형상을 보인다. 그리고 이들 접지압분포는 대체적으로 모든 지층에서 대칭분포를 나타내고 있다. 대형 뉴메틱케이슨기초에 작용한 최대접지압에 의하여 제시된 접지압분포는 Kgler(1936)와 Fang(1991)이 강성기초를 대상으로 제시한 접지압분포특성과 잘 일치하는 것으로 나타났다.

MIVB 용접용 개폐형 자속발생기에 의한 자원밀도분포의 수치해석 (Numerical Analysis of Magnetic Flux Density Distribution by an Openable Magnetic Flux Generator for MIAB Welding)

  • 구진모;김재웅
    • Journal of Welding and Joining
    • /
    • 제22권6호
    • /
    • pp.50-56
    • /
    • 2004
  • MlAB(magnetically impelled arc butt) welding is a sort of pressure welding method by melting two pipe sections with high speed rotating arc and upsetting two pipes in the axial direction. The electro-magnetic force, the driving force of the arc rotation, is generated by interaction of arc current and magnetic field induced from the magnetic flux generator in the welding system. In this study, an openable coil system for the generation of magnetic flux and a 3-dimensional numerical model for analyzing the electro-magnetic field were proposed. Through the fundamental numerical analyses, a magnetic concentrator was adopted for smoothing the magnetic flux density distribution in the circumferential direction. And then a series of numerical analysis were performed for investigating the effect of system parameters on the magnetic flux density distribution in the interested welding area.. Numerical quantitative analyses showed that magnetic flux density distribution generated from the proposed coil system is mainly dependent on the exciting current in the coil and the position of coil or concentrator from the pipe outer surface. And the gap between pipe ends and arc current are also considered as important factors on arc rotating behavior.

Vertical distributions of lateral forces on base isolated structures considering higher mode effects

  • Tsai, C.S.;Chen, Wen-Shin;Chen, Bo-Jen;Pong, Wen-Shen
    • Structural Engineering and Mechanics
    • /
    • 제23권5호
    • /
    • pp.543-562
    • /
    • 2006
  • Base isolation technology has been accepted as a feasible and attractive way in improving seismic resistance of structures. The seismic design of new seismically isolated structures is mainly governed by the Uniform Building Code (UBC-97) published by the International Conference of Building Officials. In the UBC code, the distribution formula of the inertial (or lateral) forces leads to an inverted triangular shape in the vertical direction. It has been found to be too conservative for most isolated structures through experimental, computational and real earthquake examinations. In this paper, four simple and reasonable design formulae, based on the first mode of the base-isolated structures, for the lateral force distribution on isolated structures have been validated by a multiple-bay three-story base-isolated steel structure tested on the shaking table. Moreover, to obtain more accurate results for base-isolated structures in which higher mode contributions are more likely expected during earthquakes, another four inertial force distribution formulae are also proposed to include higher mode effects. Besides the experimental verification through shaking table tests, the vertical distributions of peak accelerations computed by the proposed design formulae are in good agreement with the recorded floor accelerations of the USC University Hospital during the Northridge earthquake.

Effects of Joint Mobilization on Foot Pressure, Ankle Moment, and Vertical Ground Reaction Force in Subjects with Ankle Instability

  • Yoon, Na Mi;Seo, Yeon Soon;Kang, Yang-Hoon
    • 한국운동역학회지
    • /
    • 제26권2호
    • /
    • pp.153-159
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effects of joint mobilization on foot pressure, ankle moment, and vertical ground reaction force in subjects with ankle instability. Method: Twenty male subjects (age, $25.38{\pm}3.62yr$; height, $170.92{\pm}5.41cm$; weight, $60.74{\pm}9.63kg$; body mass index (BMI), $19.20{\pm}1.67kg/m^2$) participated and underwent ankle joint mobilization. Weight-bearing distribution, ankle dorsi/plantar flexion moment, and vertical ground reaction force were measured using a GPS 400 and a VICON Motion System (Oxford, UK), and subsequently analyzed. SPSS 20.0 for Windows was used for data processing and paired t-tests were used to compare pre- and post-mobilization measurements. The significance level was set at ${\alpha}$ = .05. Results: The results indicated changes in weight-bearing, ankle dorsi/plantar flexion moment, and vertical ground reaction force. The findings showed changes in weight-bearing distribution on the left (pre $29.51{\pm}6.31kg$, post $29.57{\pm}5.02kg$) and right foot (pre $32.40{\pm}6.30kg$, post $31.18{\pm}5.47kg$). There were significant differences in dorsi/plantar flexion moment (p < .01), and there were significant increases in vertical ground reaction forces at initial stance (Fz1) and terminal stance (Fz2, p < .05). Additionally, there was a significant reduction in vertical ground reaction force at midstance (Fz2, p < .001). Conclusion: Joint mobilization appears to alter weight-bearing distribution in subjects with ankle instability, with resultant improvements in stability.

부스바 접점 가동시 접촉면에서 압점력 해석 (Analysis for Force Distribution on Surface Between Busbar Contacts)

  • 오연호;송기동;김귀식;김진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.82-84
    • /
    • 2003
  • In case contact between point of contacts is not achieved well, contact resistance is grown, and by current concentration at current conducting contacts can weld. In order to decrease contact resistance between contacts in case of busbar, installing spring between fixed contact and moving contact. and then force on faying surface of contacts increase and contact resistance decrease. But, in case increase force of spring to widen contact area, operating force moving contact can grow, on the contrary force of spring is small, contact resistance becomes low. Therefore, need to optimize force and number of spring. position, and also need to examine force change on contact surface at point of contact moving. In this paper, dynamic kinetics analysis for force on faying surface of contacts is performed at unsteady state. It is showed to not uniform force on surface between contacts, and we can got more uniform force by means of change spring position.

  • PDF

Fault Tolerant Control of Magnetic Bearings with Force Invariance

  • Na, Uhn-Joo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.731-742
    • /
    • 2005
  • A magnetic bearing even with multiple coil failure can produce the same decoupled magnetic forces as those before failure if the remaining coil currents are properly redistributed. This fault-tolerant, force invariance control can be achieved with simply replacing the distribution matrix with the appropriate one shortly after coils fail, without modifying feedback control law. The distribution gain matrix that satisfies the necessary constraint conditions of decoupling linearized magnetic forces is determined with the Lagrange Multiplier optimization method.

회절을 고려한 반무한방파제 형식의 직립구조물에 작용하는 지점별 파력 분포 (Distribution of Wave Forces at Points on a Vertical Structure of Semi-Infinite Breakwater Considering Diffraction)

  • 정재상;이창훈;조용식
    • 한국해안·해양공학회논문집
    • /
    • 제28권4호
    • /
    • pp.240-249
    • /
    • 2016
  • 본 연구에서는 회절을 고려하여 반무한방파제 형식의 직립구조물에 작용하는 지점별 파력 분포를 검토하였다. 비쇄파 조건에서 직립구조물에 작용하는 규칙파 및 불규칙파의 파력에 대해 방파제 전, 후면의 회절을 모두 고려하여 연구하였다. 방파제의 폭이 0인 조건을 비교 대상의 기준 조건으로 채택하였다. 규칙파의 경우 방파제 두부(head of breakwater)에서는 전후면의 입사파 및 회절파가 동시에 작용하여 상대 파력이 0이 되었으며, 두부에서 멀어지면 상대 파력 1.0을 중심으로 진동하는 패턴이 나타났다. 또한 경사입사각이 증가할 경우 규칙파의 상대 파력은 감소하는 경향을 보였다. 본 연구에서는 제곱평균의 제곱근비와 파력 스펙트럼을 이용하여 불규칙파의 상대 파력을 정의하였다. 각 성분파가 갖는 임의의 위상을 고려한 경우와 고려하지 않은 경우를 비교하였으며, 그 결과는 거의 동일하게 나타났다. 불규칙파의 경우 방파제 두부 근처에서 규칙파와 마찬가지로 상대 파력이 0으로 나타났으며, 두부에서 멀어질 때에는 다양한 성분파의 합성에 의해 상대 파력 1.0을 기준으로 진동하는 패턴이 비교적 약하게 나타났다.

밀링가공에서의 온도분포와 절삭력 예측을 위한 연구 (A Study on the Prediction of Temperature Distribution and Machining Force in the Milling Process)

  • 강재훈;송준엽;박종권
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.394-397
    • /
    • 2004
  • This paper presents a simple analytic method using 2D simulation program for predications of cutting force and machining temperature in dry type milling process. And also, comparison of cutting force and machining temperature obtained from experiment and simulation work is accomplished to distinguish of suitability.

  • PDF