• Title/Summary/Keyword: Foot contact area

Search Result 58, Processing Time 0.035 seconds

The Effects of Baby Carrier and Sling in Muscle Activation of Trunk, Low Extremity and Foot Pressure (아기띠와 슬링 착용이 체간과 하지의 근활성 및 족저압에 미치는 영향)

  • Yuk, Goon-Chang;Park, Rae-Joon;Lee, Hyun-Young;Lee, Myoung-Hee;Lee, Jeon-Hyeong;Kuk, Jung-Seok;Jang, Jong-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.2
    • /
    • pp.223-231
    • /
    • 2010
  • Purpose : The Purpose of this study was to compare muscle activation and foot pressure on baby carrier and sling for baby care. Methods : Thirty one women subjects (mean age 23.2 years) participated in four static conditions : unloaded quite standing, carrying an anterior baby carrier, carrying a posterior baby carrier, and sling. The baby carrier and sling were loaded with baby model that filled 7.6kg loads. Surface electromyography was used to measure activity in the internal oblique, T4, L3, L5 paraspinal muscle, vastus medialis, biceps femoris, tibialis anterior, and gastrocnemius for four conditions. And foot pressure was measured by using MatScan system(Tekscan, USA). Results : The activation of Biceps femoris, T4, L3, and L5 paraspinal muscle were significant differences(p<.05), but other muscles were no significant differences in four conditions(p>.05). Right foot contact area and peak pressure of right mid foot area were significant differences in four conditions(p<.05). Conclusion : The results of this study indicate that the use of baby carrier of sling for baby care were influenced postural responses of young women. Further work is recommended to find out the influences of various assistive devices for baby care.

Effects of Rear-Foot Wedged Insoles on the Foot Pressure in Walking (발 뒤축 내·외측 경사진 안창이 족부압력에 미치는 영향)

  • Ryu, Taebeum;Chae, Byungkee;Lim, Wansoo;Choi, Hwa Soon;Chung, Min K.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.34 no.1
    • /
    • pp.90-97
    • /
    • 2008
  • Wedged insoles are frequently used to reduce the pains caused by the knee arthritis or the foot overuse syndrome. The present study analyzed the effect of wedged rear-foot insoles on the foot pressure in walking. Three medially wedged insoles with three angles (5, 8 and 15") and three laterally wedged insoles with the same angles were made, and a flat insole were prepared. Ten healthy males in twenties walked in a specified line with each insole. Center of pressure (COP), relative vertical force and maximum force on anatomical areas were analyzed from the measured foot pressure data. At heel contact, medially wedged insoles significantly increased the pressure of the medial foot side (COP moved medially by 2-5 mm and maximum pressure of 1st metatarsal head increased by 110-120% relative to the flat insole), In contrast, laterally wedged insoles significantly increased the lateral side pressure (COP moved laterally by 1-5 mm and the ratio of $2^{nd}$ metatarsal head pressure to $1^{st}$ metatarsal head increased by 0.5-2.0 relative to the flat insole). At toe off, both wedged insoles significantly increased the pressure of the medial foot side (COP moved medially by 0.5-10 mm and the ratio of $1^{st}$ metatarsal head pressure to $5^{th}$ metatarsal head increased by 2.0 relative to the flat insole). Especially, the laterally wedged insoles significantly increased the relative vertical force (6-12%) of the rear-foot more than the flat insole.

Effect of Taping Therapy and Inner Arch Support on Plantar Lower Body Alignment and Gait

  • Lee, Sojung;Jeong, Dawun;Kim, Dong-Eun;Yi, Kyungock
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.3
    • /
    • pp.229-238
    • /
    • 2017
  • Objective: The purpose of this study was to identify the effects of taping therapy and inner arch support on pes planus lower extremity alignment and gait. Method: The study was conducted on 13 women in their 20s who had pes planus and no gait problems. Independent variables were the condition of wearing basic socks (S1) and the condition of wearing socks with taping therapy and inner arch support (S2). The dependent variables were resting calcaneal stance position (RCSP), plantar pressure distribution during gait, and underlying and medial longitudinal arch angle measured using radiography. Statistical analysis was performed using the Wilcoxon test with SPSS 23.0 for comparison of S1 and S2. Results: In the RCSP measurement, the angle range of S2 changed to normal. Meary's angle appeared to be less than the angle of S1, indicating alleviation of the degree of pes planus. The calcaneal pitch angle increased at S2 from that at S1. The plantar pressure distribution was divided into four areas (toe, forefoot, midfoot, and hindfoot). At S2, the maximum pressure increased in the toe and midfoot. The maximum force increased significantly in the toe and midfoot but decreased significantly in the forefoot and hindfoot. In addition, the contact area increased overall especially at the midfoot and hindfoot. Contact time decreased in the toe and forefoot, but increased in the midfoot and hindfoot. Conclusion: Taping therapy and inner arch support showed structural improvement of the pes planus. In addition, the force and pressure applied to the foot during walking are distributed evenly in the area of the sole, thus positively affecting walking.

The Plantar Pressure Comparison between the Curved Rear Balance Shoes and Normal Shoes (유선형 후방 밸런스 신발과 일반 신발의 족저압 비교)

  • Kim, Youn-Joung;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.173-180
    • /
    • 2007
  • The purpose of study was to compare plantar pressure during walking wearing the curved rear balance and normal shoes. Twelve university students(height: $177.2{\pm}4.6cm$, weight: $68.4{\pm}5.8kg$, age: $26.2{\pm}1.6yrs.$) who have no known musculoskeletal disorders were recruited as the subjects. Plantar foot pressures were evaluated using the Tekscan's pressure measurement systems while subjects walked upright position wearing the curved rear balance and normal shoes in random order at a speed of 1.3 m/s. The contacting dimension, the mean plantar pressure, and the peak plantar pressure were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). As a result, the curved rear balanced shoes showed as large as 38 up to 50 % of area at the rear side of feet than the normal shoes when measuring the contact area with upright position. In the distribution of average pressure, the curved rear balanced shoes displayed fairly low pressure compared to other normal shoes in general except for one area, which is M2, and especially, the measured pressures at the both rear (M1) and middle (M5) side of feet were low and statically significant. The contact area of the curved rear balanced shoes when walking was significantly larger at the rear (M1) and fore (M6, M7) side of feet. When considering pressure distribution at walking, low pressure was detected at the rear side of feet with the curved rear balanced shoes and at the fore side of feet for other normal shoes. The results showed that the contacting dimension of the curved rear balance shoes that acts between shoes and feet was higher than the corresponding value for the normal shoes in general; therefore it would reduce the pressure to the feet by allowing the each sole of the foot on the ground evenly.

Reconstruction for the Soft Tissue Defect of Heel using Free Lateral Arm Neurosensory Flap (유리 외측 상박 감각신경 피판술을 이용한 종부 연부조직 결손의 재건)

  • Kim, Dong-Churl;Kim, Sang-Soo;Ha, Dae-Ho;Yoo, Hee-Jun;Lee, Dong-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.15-21
    • /
    • 1999
  • Soft tissue defect on heel area of the foot present difficult problems particularly because of anatomic property of plantar surface of the foot. There is a paucity of available local tissue in the foot for coverage. In addition to having little expandable tissue, the foot's plantar surface has a unique structure, making its replacement especially challenging. Plantar skin is attached to the underlying bone by fibrous septa, preventing shear of the soft-tissue surfaces from the underlying skeleton. Plantar surface of foot is in constant contact with the environment. Protective sensibility also would be maintained or restored in the ideal reconstruction. So the ideal flap for reconstruction of the heel should include thin, durable hairless skin with potential for reinnervation. The aim of this article is to present a clinical experience of free lateral arm neurosensory flap for reconstruction of the heel. From March 1995 to December 1997, a total 16 lateral arm free flaps were performed to soft tissue defects on the weight-bearing area of the hindfoot. we used tibial nerve as recepient nerve in 11 and calcaneal branch of tibial nerve in 5 for restoration of sensibility of flap. All cases survived completely. A static two-point discrimination of 14 to 34mm was detected in the flap. Radial nerve palsy which was caused by hematoma in donor site occured in one case, but recorverd in 3 weeks later completely. In conclusion, the lateral arm free flaps are versatile, reliable and sensible cutaneous flap and especially indicated for soft tissue defect on plantar surface of the hindfoot which are not good indications for other better-known flaps.

  • PDF

Development of a Pressure Distribution Measurement System (압력분포 측정시스템의 개발)

  • 정진호;이기원;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.213-218
    • /
    • 2000
  • Pressure distributions of the soft tissue are valuable for understanding and diagnosing the disease characteristics due to the mechanical loading. Our system measures dynamic pressure distributions in real-time under the general PC environment, and analyzes various foot disorders. Main features of the developed system are as follows: (1) With the resistive pressure sensor matrix of 40${\times}$40 cells, the data is sent to the PC with the maximum sampling rate of 40 frames/sec. (2) For each frame, contact area, pressure and force are analyzed by graphic forms. Thus, various biomechanical parameters are easily determined at specific areas of interests. (3) A certain stance phase can be chosen for the analysis from the continuous walking, and the detailed biomechanical analysis can be done according to an arbitrary line dividing anterior/posterior or medial/lateral plantar areas. (4) The center of pressure (COP) is calculated and traced from the pressure distribution data, and thus the movement of the COP is monitored in detail. A few experiments revealed that our system successfully measured the dynamic plantar distribution during normal walking.

  • PDF

Fragmented Split-Thickness Skin Graft Using a Razor Blade in Burn Induced Diabetic Foot (화상을 동반한 당뇨발 환자에게 Razor Blade를 이용한 부분층피부조각 이식술의 효용성)

  • Park, Cheol-Heum;Choi, Manki;Kang, Chan-Su;Kim, Tae-Gon
    • Journal of the Korean Burn Society
    • /
    • v.23 no.1
    • /
    • pp.20-24
    • /
    • 2020
  • Diabetic patients have an increased risk of burn injuries on foot. Because of their diabetic neuropathy, they could contact with hot water or warming device without being aware of it. Split-thickness skin graft (STSG) is successful in treatment of various wound types; however, donor site wounds are sometimes problematic, and complications such as pain and impaired healing often occur. Although, donor site wounds in healthy young individuals can rapidly heal without complications, the wound-healing capacity of elderly patients or those with a comorbidity has been reported to be low. The dermatome is the most commonly used tool because it can harvest a large skin graft in one attempt. However, it is difficult to harvest tissues if the area is not flat. Furthermore, because the harvested skin is usually rectangular, additional skin usually remains after skin grafting. Therefore, use of razor blade and fragmented STSG on a large defect area is advantageous for harvesting a graft with a desired size, shape, and thickness. From January 2018 to July 2018, fragmented STSG was used in 9 patients who suffered from burn induced open wound on foot with diabetic neuropathy. With this approach, healing process was relatively rapid. The mean age of patients was 70 (57~86 years) and all of 9 patients had diabetes mellitus type 2. In all patients, the skin graft on the defect site healed well and did not result in complications such as hematoma or seroma.

Plantar foot pressure distribution depending on ground conditions and shoe type (지반조건과 신발의 종류에 따른 족저압 분포)

  • Kim, Sang-Hwan;Lee, Hye-Yoon;Kim, Yeon-Deok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2899-2905
    • /
    • 2015
  • This paper presents is a study on the pressure distribution families low in response to ground conditions. Indoor shoes, outdoor shoes, working shoes, are four categories of shoes sports shoes, has been used in the present study, Concrete to target men in their 20s of 45people wearing the 260mm(Euro Code EU40), the experiments were carried out in the sand ground. Measurement of stress and pressure at the time of walking, Techstorm company Insole System the measured toe of the foot using, foot binding, was the metatarsal, the low pressure come from Fujoku four areas measured. Depending on the shoes and ground conditions findings, the results of this study represents the distribution of other stress and pressure, is expected to be useful in the development of a wearable shoe sand soil.

The Research on Functional Midsole that can Minimize Forefoot Pressure - Focusing on High-Heeled Pumps Type - (전족부 압력을 최소화할 수 있는 기능성 중창에 관한 연구 - 굽높은 펌프스형을 중심으로 -)

  • Kim, Dong-Yeoub;Choi, Soon-Bok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.2 s.161
    • /
    • pp.258-268
    • /
    • 2007
  • The purpose of this research is to develop functional midsole that can restrain the heightening of plantar pressure in forefoot pressure so as to develop high-heeled shoes that can lessen foot ailments among women. The pumps shoes used for the research were of the same pumps type last. The variant was heel height, 3cm, 6cm, and 9cm, and the shoes were made in both normal midsole and functional midsole. The variant was applied to investigate the changes of foot pressure on forefoot and hindfoot according to heel height.'Heel Cup' was chosen for modification of functional midsolepumps type. to enlarge contact area in hindfoot, and 'Heel Posting Pad' was attached under sustentaculum tali to suppress the weight moving to forefoot pressure. If such functional parts are developed and used, it is possible to lessen the amount of Pmax or Impulse imposed by high-heeled pumps type on forefoot pressure. This can greatly lessen foot ailments, largely caused by high-heeled shoes, among women.

Effects for Running Shoes with Resilience of Midsole on Biomechanical Properties (미드솔의 반발탄성이 러닝화의 생체역학적 특성에 미치는 영향)

  • Yoo, Chan-Il;Won, Yonggwan;Kim, Jung-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.103-111
    • /
    • 2015
  • Objective : The purpose of this study was to evaluate the effect for running shoes with resilience of midsole on biomechanical properties. Methods : 10 healthy males who had no history of injury in the lower extremity with an average age of 26.5 year(SD=1.84), height of 172.22 cm(SD=4.44) and weight of 67.51 kg(SD=6.17) participated in this study. All subjects ran on the treadmill wearing three different running shoes. Foot pressure data was collected using Pedar-X system(Novel Gmbh, Germany) operating at 100 Hz. Surface EMG signals for biceps femoris, rectus femoris, vastus lateralis, medial lateralis, tibialis anterior, medial gastrocnemius, soleus and peroneus longus were acquired at 1000 Hz using Bignoli 8 System(Delsys Inc., USA). To normalize the difference of the magnitude of muscle contractions, it was expressed as a percentage relative to the maximum voluntary contraction (MVC). The impact resilience of the midsole data was collected using Fastcam SA5 system(Photron Inc., USA). Collected data was analyzed using One-way ANOVA in order to investigate the effects of each running shoes. Results : TPU midsole was significantly wider in contact area than EVA, TPE midsole in midfoot and higher in EMG activity than EVA midsole at biceps femoris. TPE midsole was significantly wider in contact area than EVA midsole in rearfoot and higher in peak pressure than EVA midsole in forefoot. EVA midsole was significantly higher in EMG activity than TPU midsole at tibia anterior. In medial resilience of midsoles, TPE midsole was significantly higher than EVA, TPU midsole. Conclusion : TPU midsole can reduce the load on the midfoot effectively and activate tibialis anterior, biceps femoris to give help to running.