• Title/Summary/Keyword: Food Wastewater

Search Result 246, Processing Time 0.026 seconds

Microbial Immobilization, Characterization and Isolation of Nitrogen Oxidizing Bacteria (암모니아 및 아질산성 질소 산화세균의 분리 및 특성)

  • Lee, Yong-Seok;Yoo, Ju-Soon;Chung, Soo-Yeol;Park, Choon-Soo;Choi, Yong-Lark
    • Applied Biological Chemistry
    • /
    • v.46 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • Abstract: In order to improve the system for biological nitrogen oxidizing process in sewage and wastewater, a bacterium having high abilities to oxidize of nitrogen was isolated from wastewater and polluted soils. The strain was identified to Bacillus sp. CH-N, based on the physiological and biochemical properties. Characteristics and oxidizing ability of both ammonia and nitrite were examined for the strain, Bacillus sp. CH-N. The strain showed the oxidizing rate about 80% to 90% on the sewage and wastewater after 48 h culture. The nitrogen oxidizing rate was increased in proportion to the initial concentration of glucose. The microorganism, Bacillus sp. CH-N cell immobilized on ceramic carrier were evaluated for the oxidation of ammonia in culture media.

Comparison of response surface methods for the optimization of an upflow anaerobic sludge blanket for the treatment of slaughterhouse wastewater

  • Chollom, Martha Noro;Rathilal, Sudesh;Swalaha, Feroz Mohammed;Bakare, Babatunde Femi;Tetteh, Emmanuel Kweinor
    • Environmental Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.114-122
    • /
    • 2020
  • This study was aimed at using the Central Composite Design (CCD) and Box-Behnken Design (BBD) to compare the efficiency and to elucidate the main interacting parameters in the upflow anaerobic sludge blanket (UASB) reactor, namely: Organic Loading Rate (OLR), Hydraulic Retention Times (HRT) and pH at a constant temperature of 35℃. Optimum HRT (15 h), OLR (3.5 kg.m-3.d-1) and pH (7) resulted in biogas production of 5,800 mL/d and COD removal of 80.8%. BBD produced a higher desirability efficiency of 94% as compared to the CCD which was 92%. The regression quadratic models developed with high R2 values of 0.961 and 0.978 for both CCD and BBD, respectively, demonstrated that the interaction models could be used to pilot the design space. BBD model developed was more reliable with a higher prediction of biogas production (5,955.4 ± 225.3 mL/d) and COD removal (81.5 ± 1.014%), much close to the experimental results at a 95% confidence level. CCD model predictions was greater in terms of COD removal (82.6 ± 1.06% > 80.8%) and biogas production (4,636.31 mL/d ± 439.81 < 5,800 mL/d) which was less than the experimental results. Therefore, RSM can be adapted for optimizing various wastewater treatment processes.

Field Application of Least Cost Design Model on Water Distribution Systems using Ant Colony Optimization Algorithm (개미군집 최적화 알고리즘을 이용한 상수도관망 시스템의 최저비용설계 모델의 현장 적용)

  • Park, Sanghyuk;Choi, Hongsoon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.413-428
    • /
    • 2013
  • In this study, Ant Colony Algorithm(ACO) was used for optimal model. ACO which are metaheuristic algorithm for combinatorial optimization problem are inspired by the fact that ants are able to find the shortest route between their nest and food source. For applying the model to water distribution systems, pipes, tanks(reservoirs), pump construction and pump operation cost were considered as object function and pressure at each node and reservoir level were considered as constraints. Modified model from Ostfeld and Tubaltzev(2008) was verified by applying 2-Looped, Hanoi and Ostfeld's networks. And sensitivity analysis about ant number, number of ants in a best group and pheromone decrease rate was accomplished. After the verification, it was applied to real water network from S water treatment plant. As a result of the analysis, in the Two-looped network, the best design cost was found to $419,000 and in the Hanoi network, the best design cost was calculated to $6,164,384, and in the Ostfeld's network, the best design cost was found to $3,525,096. These are almost equal or better result compared with previous researches. Last, the cost of optimal design for real network, was found for 66 billion dollar that is 8.8 % lower than before. In addition, optimal diameter for aged pipes was found in this study and the 5 of 8 aged pipes were changed the diameter. Through this result, pipe construction cost reduction was found to 11 percent lower than before. And to conclusion, The least cost design model on water distribution system was developed and verified successfully in this study and it will be very useful not only optimal pipe change plan but optimization plan for whole water distribution system.

Simultaneous Removal of Organic and Nitrogen in the Treatment of Fish Processing Wastewater using Entrapped Mixed Microbial Cell (EMMC) Process (Entrapped Mixed Microbial Cell (EMMC) 공정을 이용한 수산물 가공 폐수처리에서 유기물 및 질소 동시제거)

  • Jeong, Byung Cheol;Park, Kwon Sam;Jeong, Byung Gon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.492-497
    • /
    • 2006
  • Feasibility of simultaneous removal of organic materials and nitrogen in the wastewater from fisheries processing plant was evaluated using entrapped mixed microbial cell (EMMC) process. The experiment was performed using activated sludge from municipal sewage treatment plant which was immobilized with gel matrix by cellulose triacetate. It was found the stable operation at the treatment system which is composed of anoxic and oxic tank, was possible when the organic and nitrogen loading rates were increased stepwise. The organic and nitrogen loading rates were conducted from 0.65 to $1.72kgCOD/m^3/d$ and from 0.119 to $0.317kg\;T-N/m^3/d$ with four steps, respectively. The maximum nitrogen loading rate which could satisfy the regulated effluent standard of nitrogen concentration, was $0.3kg\;T-N/m^3/d$. The removal efficiency of total nitrogen was decreased apparently as increasing nitrogen loading rates, whereas the removal efficiency of ammonium nitrogen was effective at the all tested nitrogen loading rates. Therefore, it was concluded that nitrification was efficient at the system. Nitrate was removed efficiently at the anoxic tank. whereas the nitrification efficiency at the oxic tank ranged 94.0% to 96.9% at the tested loading rates. The removal efficiencies of chemical oxygen demand (COD) and those of total nitrogen at the entire system ranged from 94.2% to 96.6% and 73.4% to 83.4%, respectively.

Optimization of Operating Conditions for Each Linked Treatment Scenario using Sewage Treatment Modeling (하수처리 모델링을 이용한 연계처리 시나리오별 운전조건 최적화)

  • Kim, Sungji;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.7-13
    • /
    • 2021
  • Due to rapid industrial development, population growth, and improvement of living standards, the amount of sewage and wastewater, including nutrients, is increasing every year. In addition to the increasing amount of sewage and wastewater generation, untreated linked treated water (manure, livestock manure, industrial wastewater, leachate, food waste) is also increasing, and many of the linked treated water flows directly into nearby sewage treatment plants. The associated treated water causes many problems because of its own characteristics, low flow rate with high concentration compared to existing inflow sewage. In order to solve this problem, it is necessary to investigate the quantity and quality of the connected treated water whichh is flowed into the sewage treatment plant, and a study the effect on sewage treatment. Therefore, in this paper, we would like to examine the effect of the linked treated water. Seasonal effect associated with water pollution conditions was considered. In addition, a scenario was created through the distribution and inflow of connected treated water along with the water temperature conditions. Through scenario analysis, we intend to optimize the operating conditions of linked processing.

Ceramic based Nanofiltration Membrane for Wastewater Treatment: A Review (폐수처리를 위한 세라믹계 나노여과막: 리뷰)

  • Yeonsoo, Kwak;Rajkumar, Patel
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.390-400
    • /
    • 2022
  • Nanofiltration (NF) membranes are more popular than reverse osmosis (RO) membranes as they can be operated at much lower pressures for applications in treatment of wastewater from industries like food processing and pharmaceutical as well as municipal sewage water. The separation mechanism in case of NF membranes is based on solution diffusion as well as sieving, for which the crosslinking density of the thin film of the composite membrane is less then RO membrane. Unlike ceramic membranes, membrane fouling is one of the chronic problems that occur during the nanofiltration process in polymeric membranes. Membrane cleaning is done to get rid of reversible as well as irreversible fouling by treatment with sodium hypochlorite. Compared to polymeric membranes, ceramic membranes show higher stability against these agents. In this review different types of ceramic membrane applied wastewater treatment by NF process are discussed.

Isolation and Characterization of a Antimicrobial Compound from Bacillus coagulans

  • Abada, Emad Abd El-moniem
    • Animal cells and systems
    • /
    • v.12 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • A bacterium strain called Bacillus coagulans was isolated from an industrial wastewater drainage and selected for its antimicrobial activities against bacteria and fungi. Characterization studies strongly suggested that this strain is Bacillus coagulans. Antimicrobial activity was found against gram-positive, gram-negative bacteria and yeast strain. Maximal activity was observed after 24 h when incubated at $30^{\circ}C$ and pH 8. The activity was found to be stable at $75^{\circ}C$ for 30 min and at pH range of 2-12. Analysis of the antimicrobial compound by SDS-PAGE suggested a molecular mass of approximately 7.5 KDa. The substance was characterized as a bacteriocin, because of its proteinaceous nature and low molecular weight. Our bacteriocin could potentially be used as a food preservative, because of its thermostable property and broad antimicrobial spectrum.

A Study on the Degradation Process of Organophosphorus Insecticides depending on Variation of pH in Several Waters (몇 종류의 물에서 pH 변화에 의한 유기인계 살충제의 분해과정에 관한 고찰)

  • 김종향;하대식
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.4
    • /
    • pp.185-189
    • /
    • 1994
  • This study was to investigate time-dependent degradation process under various pH condition for organophosphorus(org-p) insecticides, namely Demeton-s-methyl, diazinon, Parathion, Phenthoate, and EPN in several waters. They were analysed by GC-FTD according to standard methods for the examination of water and wastewater. In pH=4, diazinon showed disappearance after 14 days in chromatogram. In pH=11, org-p insecticides were almost degradable after 7 days. In this condition, effect of pH on degradation process was greater than of light. In pH=7, org-p insecticides persisted residues after 112 days except Demeton-s-methyl. In BOD5 120, 250 ppm and domestic water, org-p insecticides showed also rapid degradation process.

  • PDF

A Study on the Optimum Treatment Criteria of the Leachate for Food Waste Composting (음식물 쓰레기 퇴비화를 위한 탈리액의 적정 처리 기준 설정 연구)

  • Kwon, Woo-Seok;Sin, Jin-Ho;Nam, Duk-Hyon;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.397-402
    • /
    • 2006
  • The treatment characteristics of leachate produced from pretreatment facilities like composting and feeding were investigated in a mesophilic anaerobic treatment. Experiments were performed in two phase which were acidification and methane fermentation. The acidification step was optimized for OLR from 1 to $4.5kg\;COD/kg\;VS{\cdot}day$ without adding NaOH. As experiment dates became longer, the solubilization ratio of particles increased up to 30% over 70 days. TVA was generated up to maximum 9,970mg HAc/L at OLR of $2kg\;COD/kg\;VS{\cdot}day$. But TVA was generated to minimum 6,519mg HAc/L at OLR of $4.5kg\;COD/kg\;VS{\cdot}day$. The acidification ratio was analyzed from 10.9% to 3.8% at OLR of $2kg\;COD/kg\;VS{\cdot}day$ and $4.5kg\;COD/kg\;VS{\cdot}day$ respectively. After 55 days, salt contents in the acid fermenter were accumulated and stabilized at the concentration of 3,150mg/L. Sodium ion($Na^+$) concentration was stabilized at 1,300mg/L. At methane fermentation step, biogas was generated up to 750ml and 937.5ml at the feeding volume of 20ml and 25ml respectively for acid fermented liquid during 25 days. About 80% of total biogas was generated during early 15 days and 95% were generated during 18 days respectively. After 25 days of the BMP test, acetic acid was removed approximately 97% and 98%, in case of those two experimental conditions.

Study on precipitate formation and the change of cations and anions in domestic bottled water (국내 시판 먹는샘물의 물성에 따른 이온성분의 변화 및 침전물 생성)

  • Lee, Eun-Kyeong;Jang, Seong-Il;Jung, Yeon-Wook;Jeon, Seong-Sook;Ju, Myeong-Hui;Lee, Soon-Ae;Park, Jong-Sook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.561-569
    • /
    • 2008
  • We analyzed contents of cations and anions for the domestic bottled drinking water. Results showed that total cation content was 45.81 mg/L and contained 40% of Ca. The content of cations were decreased in the order of Ca>Si>Na>Mg>K. Total anion content was 12.20 mg/L and contained 90% of ${SO_4}^{2-}$ and $Cl^-$. $F^-$ and $NO_{3-}N$ were a little contained. While Si content was reduced 2.3~75.7%(mean value:38.5%) after freezing, Ca content was reduced 45.2% after boiling. It showed that water containing higher Ca content was significantly decreased after boiling. Precipitates formed by freezing and boiling is composed of minerals such as Si and Ca. Compared to minerals from food intake, concentrations of minerals from water intake are expected to be less influenced. It is recommended Bottled Water that contains more than 20 mg/L of Ca(exceeding water-quality standard for turbidity) is safe to drink without thawing and boiling.