• 제목/요약/키워드: Focused Plasma

검색결과 211건 처리시간 0.031초

Analysis of Biological Effect of DBD-type Non-thermal Atmospheric Pressure Plasma on Saccharomyces Cerevisiae

  • Park, Gyung-Soon;Baik, Ku-Yeon;Kim, Jung-Gil;Kim, Yun-Jung;Lee, Kyung-Ae;Choi, Eun-Ha;Uhm, Hwan-Sup;Jung, Ran-Ju;Cho, Kwang-Sup
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.337-337
    • /
    • 2011
  • Application of plasma technology on microbial sterilization has been frequently studied. In spite of accumulating number of studies, many have been focused on bacteria. Reports on eukaryotic yeasts and filamentous fungi are limited. In addition, mechanism of plasma effect still needs to be clarified. In this study, we analyzed the effect of non-thermal atmospheric pressure plasma on the budding yeast, Saccharomyces cerevisiae using DBD-type device. When yeast cells were exposed to plasma (at 2 mm distance) and then cultured on YPD-agar plate, number of cells survived (shown as colony) were reduced proportionally to exposure time. More than 50% reduction in number of colonies were observed after twice exposure of 5min. each. Colonies much smaller than those of control (no plasma exposure) were appeared after twice exposure of 5 min. each. It seems that small colonies are resulted from delayed cell growth due to the damage caused by plasma treatment. Microscopic analysis demonstrates that yeast cells treated with plasma for 5 min. twice have more rough and shrinked shape compared to oval shape with smooth surface of control.

  • PDF

Measurement of EUV (Extreme Ultraviolet) and electron temperature in a hypocycloidal pinch device for EUV lithography

  • Lee, Sung-Hee;Hong, Young-June;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.108-108
    • /
    • 2010
  • We have generated Ne-Xe plasma in dense plasma focus device with hypocycloidal pinch for extreme ultraviolet (EUV) lithography and investigated an electron temperature. We have applied an input voltage 4.5 kV to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ne-Xe(30%) gas in accordance with pressure. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium (LTE) conditions, the electron temperature of the hypocycloidal pinch plasma focus could be obtained by the optical emission spectroscopy (OES). The electron temperature has been measured by Boltzmann plot. The light intensity is proportion to the Bolzman factor. We have been measured the electron temperature by observation of relative Ne-Xe intensity. The EUV emission signal whose wavelength is about 6~16 nm has been detected by using a photo-detector (AXUV-100 Zr/C, IRD) and the line intensity has been detected by using a HR4000CG Composite-grating Spectrometer.

  • PDF

Development of CO Laser-Arc Hybrid Welding Process

  • Lee, Se-Hwan
    • 한국레이저가공학회지
    • /
    • 제5권3호
    • /
    • pp.15-20
    • /
    • 2002
  • The principal obstacle to selection of a laser processing method in production is its relatively high equipment cost and the natural unwillingness of production supervision to try something new until it is thoroughly proven. The major objective of this work is focused on the combined features of gas tungsten arc and a low-power cold laser beam. In this work, the laser beam from a 7 watts carbon monoxide laser was combined with electrical discharges from a short-pulsed capacitive discharge GTA welding power supply. When the low power CO laser beam passes through a special composition shielding gas, the CO molecules in the gas absorbs the radiation, and ionizes through a process blown as non-equilibrium, vibration-vibration pumping. The resulting laser-induced plasma(LIP) was positioned between various configurations of electrodes. The high-voltage impulse applied to the electrodes forced rapid electrical breakdown between the electrodes. Electrical discharges between tungsten electrodes and aluminum sheet specimens followed the ionized path provided by LIP. The result was well-focused melted spots.

  • PDF

레이저 유도 플라즈마에 대한 자기장 감금의 영향 연구 (Research on the magnetic confinement of laser-induced plasma)

  • 현은주;김용현
    • 전기전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.38-45
    • /
    • 2024
  • 간단한 자기장 감금이 레이저 유도 플라즈마의 전하 입자들에 미치는 영향이 논의 되었다. 자기장 영향에 대한 이전 연구들은 주로 플라즈마 방전 세기의 향상이나 수명시간 연장에 집중되었다. 이와 대조적으로, 본 개발은 과거에 거의 다뤄지지 않았던, 플라즈마 소멸에 대해 연구하였다. 이는 플라즈마를 활용한 기술개발에 혁신적인 도움이 될 것으로 기대한다. Nd:YAG 레이저(1064 nm, 6 ns)가 3가지 타입의 금속 물질(Al, Ti, STS)과 공기 중에 집광되었다. Nd2Fe14B 자석으로 0.4T 크기의 자기장을 만들었고, 이를 레이저 유도 플라즈마에 관통시켰다. 플라즈마 스펙트럼은 레이저 파워와 분광기의 딜레이 타임을 조정해 가면서 자기장 여부에 따른 수치가 측정되었다. O I(777.42 nm), Fe I (520.447 nm), Ti I (503.649 nm), Al I (396.147 nm) 스펙트럼 분석을 통해 자기장에 의한 플라즈마의 소멸이 특정 조건에 상관없이 항상 촉진됨을 독점적으로 발견하였다.

고전압 방전 플라즈마에 의한 질화탄소 박막 증착 시 플라즈마 영역에 가한 레이저 애블레이션의 효과 (Effect of a Laser Ablation on High Voltage Discharge Plasma Area for Carbon Nitride Film Deposition)

  • 김종일
    • 한국전기전자재료학회논문지
    • /
    • 제15권6호
    • /
    • pp.551-557
    • /
    • 2002
  • Carbon nitride films have been deposited on Si(100) substrate by a high voltage discharge plasma combined with laser ablation in a nitrogen atmosphere. The films were grown both with the without the presence of an assisting focused Nd:YAG laser ablation. The laser ablation of the graphite target leads to vapor plume plasma expending into th ambient nitrogen arc discharge area. X-ray photoelectron spectroscopy and Auger electron spectroscopy were used to identify the binding structure and the content of the nitrogen species in the deposited films. The nitrogen content of the films was found to increase drastically with an increase of nitrogen pressure. The surface morphology of the films was studied using a scanning electron microscopy. Data of infrared spectroscopy and x-ray photoelectron spectroscopy indicate the existence of carbon-nitrogen bonds in the films. The x-ray diffraction measurements have also been taken to characterize the crystal properties of the obtained films.

집속된 레이저빔에 의한 레이저 유도 플라즈마 채널의 형성 및 팽창에 관한 연구 (Plasma Channel Expansion in a Laser-Induced Plasma (LIP) Using a Focused Laser Beam)

  • Kim, Jong-Uk;Kim, Chang-Bum;Kim, Guang-Hoon;Lee, Hae-June;Hyyong Suk
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 하계학술발표회
    • /
    • pp.240-241
    • /
    • 2002
  • Propagation of an intense laser pulse through fully ionized plasma has been an interesting topic in many fields. It includes laser-driven electron accelerators,(1) generation of high harmonics,(2) soft x-ray laser development(3) and so on. Specifically, in the application of laser-driven electron accelerators a large laser-plasma interaction length is required to get sufficient acceleration energy of electron. (omitted)

  • PDF

Influence of sintering temperature of MgO pellet on the electro-optical characteristics of alternating current plasma display panel (AC-PDP)

  • Hong, Sung-Hee;Son, Chang-Gil;Jung, Seok;Kim, Jung-Seok;Paik, Jong-Hoo;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.400-403
    • /
    • 2008
  • We have investigated the electro-optical characteristics of AC-PDP with different MgO protective layers, which have been deposited by electron beam evaporation from various sintered pellets with different temperatures. We have measured the secondary electron emission coefficient ($\gamma$) by using the Gamma Focused Ion Beam ($\gamma$-FIB) system, the static margin, and the address delay time. Also, we have investigated photoluminescence (PL) characteristics for understanding the energy levels of MgO pellets and protective layers.

  • PDF

P018 Comparison between Cutoff Probe and Langmuir Probe: Focused on Measurement Technique Error

  • 권준혁;김대웅;유신재;신용현
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.235.1-235.1
    • /
    • 2014
  • Precise measurement of plasma parameters including density and temperature is the most essential part for understanding plasma characteristics. To persue more accurate measurement, it is very important to understand the intrinsic error of the measurement method. In this paper, we performed the plasma measurement with different method; langmuire probe and cutoff probe. Both measurement technology are known to be exactly correlate with etch other. We conducted the four set of same experiments process by diffrent persons to observe the intrinsic error based on measurement tools. As a result, the cutoff probe is relatively reliable then the Langmuir probe. This difference is analyzed to be intrinsic since it cames from the inevitable error such as manufacturing of probe tip. From this study, we sure that it is good decision to choose cutoff probe as repeatable measurement independent with intrinsic human factor.

  • PDF

Optical Diagnostics for Pulse-discharged Plasma by Marx Generator and Its Application for Modifications of Hemoglobin and Myoglobin Proteins

  • Park, Ji Hoon;Attri, Pankaj;Hong, Young June;Park, Bong Sang;Jeon, Su Nam;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.176.2-176.2
    • /
    • 2013
  • Property of optical diagnostics for pulse-discharged plasma in liquid and its biological applications to proteins are investigated by making use of high voltage Marx generator. The Marx generator has been consisted of 5 stages, where each charging capacitor is 0.5 ${\mu}F$, to generate a high voltage pulse with rising time of $1{\mu}s$. We have applied an input voltage of 6 kV to the each capacitor of 0.5 ${\mu}F$. High voltage pulsed plasma has been generated inside a polycarbonate tube by a single-shot operation, where the breakdown voltage is measured to be 7 kV, current of 1.2 kA, and pulse width of ~ 1 ${\mu}s$ between the two electrodes of anode-cathode whose material is made of tungsten pin, which are immersed into the liquids. We have investigated the emitted hydrogen lines for optical diagnostics of high voltage pulsed plasma. The emission line of 656.3 nm from $H-{\alpha}$ and 486.1 nm from $H-{\beta}$ have been measured by a monochromator. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium conditions, the electron temperature and density of the high voltage pulsed plasma in liquid could be obtained by the Stark broadening of optical emission spectroscopy. For the investigation of the influence of pulsed plasma on biological proteins, we have exposed it onto the proteins such as hemoglobin and myoglobin. The structural changes in these proteins and their analysis have also been obtained by circular dichroism (CD) and ultraviolet (UV) visible spectroscopy.

  • PDF

유도결합형 플라즈마 소스를 이용한 집속 이온빔용 가스 이온원 개발 (Development of Inductively Coupled Plasma Gas Ion Source for Focused Ion Beam)

  • 이승훈;김도근;강재욱;김태곤;민병권;김종국
    • 한국정밀공학회지
    • /
    • 제28권1호
    • /
    • pp.19-23
    • /
    • 2011
  • Recently, focused ion beam (FIB) applications have been investigated for the modification of VLSI circuit, the MEMS processing, and the localized ion doping, A multi aperture FIB system has been introduced as the demands of FIB applications for high speed and large area processing increase. A liquid metal ion source has problems, a large angular divergence and a metal contamination into a substrate. In this study, a gas ion source was introduced to replace a liquid metal ion source. The gas ion source generated inductively coupled plasma (ICP) in a quartz tube (diameter: 45 mm). Ar gas fed into the quartz was ionized by a 2 turned radio frequency antenna. The Ar ions were extracted by 2 extraction grids. The maximum extraction voltage was 10 kV. A numerical simulation was used to optimize the design of extraction grids and to predict an ion trajectory. As a result, the maximum ion current density was 38 $mA/cm^2$ and the spread of ion energy was 1.6 % for the extraction voltage.