• 제목/요약/키워드: Focal

검색결과 2,377건 처리시간 0.033초

치과 구내 X-선 촬영기의 사용연한에 따른 해상능에 관한 연구 (A STUDY OF THE RESOLUTION OF DENTAL INTRAORAL X-RAY MACHINES)

  • 김선주;정현대
    • 치과방사선
    • /
    • 제20권2호
    • /
    • pp.289-297
    • /
    • 1990
  • The purpose of this study was to assess the resolution and focal spot size of dental X-ray machines. Fifty dental X-ray machines were selected for measuring resolution and focal spot size. These machines were used in general dental clinics. The time of installation of the X-ray machine varies from 1 year to 10 years. The resolution of these machines was measured with the test pattern. The focal spot size of these machines was measured with the star test pattern. The following results were obtained: 1. The resolution of dental intraoral X-ray machines was not significantly changed in ten years. 2. The focal spot size of dental intraoral X-ray machines was not significantly increased in ten years. The statistical analysis between the mean focal spot size and nominal focal spot size was significant at the 0.05 level about the more than 3 years used machines.

  • PDF

A Simple Method for Determining Focal Distances Using Talbot Self-Images

  • Spires, Oliver;Sasian, Jose;Lee, Sukmock
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.638-642
    • /
    • 2015
  • We present a simple method to determine the focal distances of lenses with the Talbot self-images. This method uses only one grating, and a priori knowledge of the period of the grating is replaced with a linear relation between the (de)magnified periods of the Talbot images and the lens-to-grating distance. A thick lens whose effective focal length is 500 mm was used to validate the method, and the focal distance of the converging beam was determined with the difference of 0.15% for the nominal focal distance of 521.9 mm. The determined period of the grating with the difference of 0.2% also supports the validation.

다공초점형(多孔焦点型) 콜리메타의 감도(感度)와 해상력(解像力)에 관(關)한 검토(檢討) (Study on Sensitivity and Resolution of Multihole Focusing Type Collimator)

  • 박성옥;경광현;박준철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제5권1호
    • /
    • pp.63-70
    • /
    • 1982
  • In order to estimate characteristics and functions of multi hole focusing type collimator, the authors measured the sensitivity and resolution varing with the distance between the face of collimator and source by experimental study. The results obtained with this study are as follows. 1. In comparison with focal distance obtained fram sensitivity measurement of various multi hole focusing type collimator, collimator A, C, E was 10 cm and collimator B, D was 12 cm in focal distance. 2. In regard of resolution of collimators having 10 cm focal distance, collimator A showed the finest resolutions than any other collimator(C, E). 3. By comparison regarding sensitivity by focal dist ante, the shorter the distance than a give focal distance of collimator, the worse the sensitivity of collimator. 4. With regard to resolution by focal distance, the shorter the distance than a given focal distance of collimator, the worse the resolution of collimator.

  • PDF

Focal Reducer for CQUEAN

  • Lim, Ju-Hee;Chang, Seung-Hyuk;Kim, Young-Ju;Kim, Jin-Young;Park, Won-Kee;Im, Myung-Shin;Pak, Soo-Jong
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.62.2-62.2
    • /
    • 2010
  • The CQUEAN (Camera for QUasars in EArly uNiverse) is an optical CCD camera optimized for the observation of high redshift QSOs to understand the nature of early universe. The focal reducer, which is composed of four spherical lens, is allowed to secure a wider field of view for CQUEAN, by reducing the focal length of the system by one third. We designed the lens configuration, the lens barrel, and the adapters to assemble to attach focal reducer to the CCD camera system. We performed tolerance analysis using ZEMAX. The manufacturing of the focal reducer system and its lab test of optical performance were already finished. It turned out that the performance can meet the original requirement, with the aberration and alignment error taken into account. We successfully attached the focal reducer and CQUEAN to the cassegrain focus of 2.1m telescope at McDonald Observatory, USA, and several tests of CQUEAN system were carried out. In this presentation, I will show the process of focal reducer fabrication and the result of performance test.

  • PDF

단시간의 경련성 실어증을 반복적으로 보이는 초점성 경련환자의 치험 1례 (A Clinical Case Report of a Patient with Focal Seizure who Repeatedly Shows Ictal Aphasia for a Short Time)

  • 유희정;공경환;경혁수
    • 대한한방내과학회지
    • /
    • 제27권4호
    • /
    • pp.1007-1013
    • /
    • 2006
  • Seizure can be categorized in various ways. Seizures are divided into those that are generalized and those affecting only part of the brain (focal seizure). Focal (partial) seizures are subdivided into simple seizures and complex seizures. Simple focal seizures may be manifested by focal motor, sensory or autonomic symptoms and consciousness is preserved. The above symptoms may be preceded, accompanied or followed by, and consciousness is impaired in, complex focal seizures. Ictal aphasia can arise from epileptiform discharge on cortical language areas. Generally next to the ictal aphasia, generalized seizures occur, but without losing consciousness, only aphasia takes place. A 61-year-old woman was admitted due to ictal aphasia and facial spasm, and she showed a little palpitation and was startled easily. We diagnosed her as Shimdamgiheo (心膽氣虛) and Damhwashimyo (痰火心擾), so we prescribed Chungsimondam-tang. It was effective on that case. so we report.

  • PDF

Numerical Study of a Novel Bi-focal Metallic Fresnel Zone Plate Having Shallow Depth-of-field Characteristics

  • Kim, Jinseob;Kim, Juhwan;Na, Jeongkyun;Jeong, Yoonchan
    • Current Optics and Photonics
    • /
    • 제2권2호
    • /
    • pp.147-152
    • /
    • 2018
  • We propose a novel bi-focal metallic Fresnel zone plate (MFZP) with shallow depth-of-field (DOF) characteristics. We design the specific annular slit patterns, exploiting the phase-selection-rule method along with the particle swarm optimization algorithm, which we have recently proposed. We numerically investigate the novel characteristics of the bi-focal MFZP in comparison with those of another bi-focal MFZP having equivalent functionality but designed by the conventional multi-zone method. We verify that whilst both bi-focal MFZPs can produce dual focal spots at $15{\mu}m$ and $25{\mu}m$ away from the MFZP plane, the former exhibits characteristics superior to those of the latter from the viewpoint of axial resolution, including the axial side lobe suppression and axial DOF shallowness. We expect the proposed bi-focal MFZP can readily be fabricated with electron-beam evaporation and focused-ion-beam processes and further be exploited for various applications, such as laser micro-machining, optical trapping, biochemical sensing, confocal sensing, etc.

Image quality assessments of focal spot size on radiographic images in dogs

  • Park, Sujin;Hwang, Tae Sung;Lee, Hee Chun
    • 대한수의학회지
    • /
    • 제62권1호
    • /
    • pp.8.1-8.6
    • /
    • 2022
  • The aim of this prospective study was to investigate the effects of focal spot size of X-ray tube on sharpness of clinical radiographic images of dogs and cats. Radiographic images of 24 stifle joints, 15 carpi, 18 lumbar spines, 61 thoraxes, and 47 abdomens of 102 dogs and 4 cats were obtained in the present study, using 2 X-ray tubes with nominal focal spots of 2.0 mm and 0.6 mm, respectively. The sharpness of specific anatomical structures in all the images of 5 projections was assessed. The radiographic sharpness of various anatomical structures of lumbar spine and cortex of stifle with fine focal spot was increased significantly compared with broad focal spot images. In addition, the blurred motion was significantly higher in the fine focal spot images of thorax. In conclusion, our study suggests that a selective use of fine foci for imaging of lumbar spine or cortex of stifle enhanced radiographic sharpness.

FOCAL SURFACES AND EVOLUTES OF CURVES IN HYPERBOLIC SPACE

  • Hayashi, Ryota;Izumiya, Shyuichi;Sato, Takami
    • 대한수학회논문집
    • /
    • 제32권1호
    • /
    • pp.147-163
    • /
    • 2017
  • We define de Sitter focal surfaces and hyperbolic focal surfaces of hyperbolic space curves. As an application of the theory of unfoldings of function germs, we investigate the singularities of these surfaces. For characterizing the singularities of these surfaces, we discover a new hyperbolic invariants and investigate the geometric meanings.

Brain somatic mutations in MTOR leading to focal cortical dysplasia

  • Lim, Jae Seok;Lee, Jeong Ho
    • BMB Reports
    • /
    • 제49권2호
    • /
    • pp.71-72
    • /
    • 2016
  • Focal cortical dysplasia type II (FCDII) is a focal malformation of the developing cerebral cortex and the major cause of intractable epilepsy. However, since the molecular genetic etiology of FCD has remained enigmatic, the effective therapeutic target for this condition has remained poorly understood. Our recent study on FCD utilizing various deep sequencing platforms identified somatic mutations in MTOR (existing as low as 1% allelic frequency) only in the affected brain tissues. We observed that these mutations induced hyperactivation of the mTOR kinase. In addition, focal cortical expression of mutant MTOR using in utero electroporation in mice, recapitulated the neuropathological features of FCDII, such as migration defect, cytomegalic neuron and spontaneous seizures. Furthermore, seizures and dysmorphic neurons were rescued by the administration of mTOR inhibitor, rapamycin. This study provides the first evidence that brain somatic activating mutations in MTOR cause FCD, and suggests the potential drug target for intractable epilepsy in FCD patients.

MTF 방법에 의한 카메라 렌즈 초점 자동 측정 시스템 개발 (Focal Length Measurement System for Camera Lens using the MTF)

  • 이석원;이동성;박희재;문호균;김영식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.264-270
    • /
    • 1996
  • In this paper, a computer automated system has been developed for measuring the focal length of camera lens using the MTF(Modurar Transfer Function) based on the signal processing around a line CCD and autocollimator. An optical Path for the focal length measurement system has been designed around thelight sourec, collimator, camera, mirror and the line CCD. The eyepiece of the collimator is replaced byline CCD, and the mirror is moved along the focal axis by a PC driven step motor. An efficient method has been designed for finding the optimum MTF value for the focal length based on the least squares approach. The developed system is fullycomputer automated: signal transmission to and from the camera, MTF evaluation based on the line CCD, step motor contorl, etc. The developed system has been applied to a practical camera manufacturing process and demonstrated its performance

  • PDF