• Title/Summary/Keyword: Flux2D

Search Result 852, Processing Time 0.031 seconds

Design of Magnet Shape for Axial-Flux Type Permanent-Magnet Synchronous Generator with Dual Air-Gap (횡자속형 2중 공극 영구자석 동기발전기의 마그네트 형상설계)

  • Choi K.H.;Kim K.S.;Jin M.C.;Hwang D.H.;Bae S.W.;Kim D.H.;Ro C.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.828-831
    • /
    • 2003
  • This paper presents a novel design technique and characteristic analysis of Magnet for dual air-gap axial-flux type permanent-magnet synchronous generator. The process of magnet design is applied to the motor design and steady state analysis considering output voltage waveforms and magnetic flux waveforms. Design and construction of an axial-flux permanent-magnet generator with power output at 60 [Hz], 300[r/min] is introduced. Finite-element (FE) method is applied to analyze magnet shape characteristics. The results of FE analysis show generator is feasible for use with dual air-gap axial-flux permanent- magnet synchronous generator.

  • PDF

Analysis of Transient Characteristics in Superconducting AC Generator Using the Compensated 2-D Model (보정된 2차원 모델에 의한 초전도 교류 발전기의 과도특성 해석)

  • Lee, Hyung-Woo;Chun, Yon-Do;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.103-105
    • /
    • 1998
  • This paper presents the compensated 2-D magnetic fields analysis of superconducting AC generator(SCG) by using efficient 2-D model. 3-D analysis is necessary for the accurate analysis because SCG has a large leakage flux owing to the air cored winding and end ring structure. However, in 3-D FEM, considering the movement of rotor is difficult, so efficient 2-D model which can compensate the leakage flux has been proposed and the movement of rotor is easily considered. The characteristics in transient state of SCG and the prime role of damper also have been evaluated.

  • PDF

A Study on Operating Condition of Test-Bed Plant using Membrane filtration of D Water Treatment Plant in Gwang-Ju (D정수장 정밀여과막 실증플랜트의 최적 운전조건 연구)

  • Yang, Hyung-Jae;Yi, Seung-Hoon;Moon, Kyung-Ran
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.155-163
    • /
    • 2017
  • Membrane filtration has become more popular in drinking water treatment recently, since the filtration can control not only particulate matters but also pathogenic microorganisms such as giardia and cryptosporidium very effectively. Pilot-scale ($120m^3/d$ of treatment capacity) and test-bed ($25,000m^3/d$ of treatment capacity) microfiltration experiments were conducted to find optimum operating mode and the critical flux. Optimum operating mode of pilot-test was assessed as inflow 1.0 min, filtration 36.5 min, air backwash 0.9 min, backwash 1.0 min and outflow 1.0 min with 50 LMH ($L/min{\cdot}m3^$) of critical flux. Critical Flux was calculated to be $50L/m^2-h$ (within TMP 0.5 bar) based on the increase formula of the transmembrane pressure difference according to the change of time at Flux 20, 40, 56 and 62 LMH in pilot operation. Chemical cleaning was first acid washed twice, and alkali washing was performed secondarily, and a recovery rate of 95% was obtained in the test-bed plant. The results of operating under these appropriate conditions are as follows. Turbidity of treated water were 0.028, 0.024, 0.026 and 0.028 NTU in spring, summer, autumn and winter time, respectively. Microfiltration has superior treatment capability and performance characteristics in removing suspended solids and colloidal materials, which are the main cause of turbidity and important carrier of metal elements, and it has shown great potential in being an economically substitute to traditional processes (sand filtration).

Implementation of High Magnetization System for Performance Enhancement of Magnetic Flux Leakage Tool

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Kim, Dong-Ku;Park, Dae-Jin;Rho, Yong-Woo;Seo, Kang;Park, Gwan-Soo;Choi, Doo-Hyun;Song, Sung-Jin
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.199-203
    • /
    • 2010
  • This paper discusses the effectiveness of high magnetization saturation in ILI (In-Line Inspection) using an MFL (Magnetic Flux Leakage) tool, and introduces a practical method for improving the magnetization level together with the piggability. Thin steel plates, replacing the conventional wire brushes were used as conductors to transfer the magnetic flux to the pipe wall. The newly designed MFL tool was compared with the conventional version by means of FEM (Finite Element Method) analysis and full-scale experiments. In the results, the newly developed magnetization system obtained a stronger MFL signal amplitude, specially 2.7 times stronger, than that obtained by the conventional magnetization system for the same defect dimensions.

Unbalanced Magnetic Forces in Rotational Unsymmetrical Transverse Flux Machine

  • Baserrah, Salwa;Rixen, Keno;Orlik, Bernd
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.184-192
    • /
    • 2012
  • The torque and unbalanced magnetic forces in permanent magnet machines are resultants of the tangential, axial and normal magnetic forces, respectively. Those are in general influenced by pole-teeth-winding configuration. A study of the torque and unbalanced magnetic forces of a small flux concentrating permanent magnet transverse flux machine (FCPM-TFM) in segmented compact structure is presented in this paper. By using FLUX3D software from Cedrat, Maxwell stress tensor has been solved. Finite element (FE-) magneto static study followed by transient analysis has been conducted to investigate the influence of unsymmetrical winding pattern, in respect to the rotor, on the performance of the FCPM-TFM. Calculating the magnetic field components in the air gap has required an introduction of a 2D grid in the middle of the air gap, whereby good estimations of the forces are obtained. In this machine, the axial magnetic forces reveal relatively higher amplitudes compared to the normal forces. Practical results of a prototype motor are demonstrated through the analysis.

Finite Element Analysis and Dynamics Simulation of Mechanical Flux-Varying PM Machines with Auto-Rotary PMs

  • Huang, Chaozhi;Zhang, Zhixuan;Liu, Xiping;Xiao, Juanjuan;Xu, Hui
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.744-750
    • /
    • 2019
  • A new type of auto-rotary PM mechanical flux-varying PM machine (ARPMMFVPMM) is proposed in this paper, which can overcome the problem where the air-gap magnetic field of a PM machine is difficult to freely adjust. The topology structures of the machine and the mechanical flux-adjusting device are given. In addition, the operation principle of flux-adjusting is analyzed in detail. Furthermore, the deformation of a spring with the speed variation is obtained by virtual prototype technology. Electromagnetic characteristics including the flux distribution, air gap flux density, flux linkage, electromagnetic-magnetic-force (EMF), and flux weakening ability are computed by 2D finite element method (FEM). Results show that the machine has some advantages such as the good field control ability.

A study on characteristic analysis using overhang structure in Line Start Permanent Magnet Motor (오버행 구조를 갖는 단상 유도동기 전동기의 특성해석)

  • Shin, Kwang-Chul;Kwon, Byung-Il;Rhyu, Se-Hyun;Kim, Byung-Teak
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1306-1308
    • /
    • 2005
  • The characteristic of line start permanent magnet(LSPM) motor with overhang structure is analyzed using 3dimensional finite element method(3D FEM). We propose the appropriate overhang length by considering the magnetic flux distribution according to changing overhang length and manufacturing process. 3D FEM analysis is inevitable because the increase of the total flux cannot be appropriately considered in 2D FEM. In equal model specification total flux is recalculated at 3D FEM, because of considering lamination length. This paper compares the characteristic of Back-emf with and without overhang by permanent magnet that has identical volume.

  • PDF

A Study on the Characteristics of Pollutant Loads in Kamak Bay Watershed (駕莫灣 流域의 汚染負荷 特性에 관한 硏究)

  • 이대인;조현서
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.945-954
    • /
    • 2002
  • The objective okgf this study is understanding and evaluation of temporal and spatial variation of pollutant loads by input sources for water quality management in Kamak Bay. Flow rate of rivers and ditches ranges from about $2,592-63,072m^3/d$ in October to $864-55,296m^3/d$ in January. In particular, the R2 predominated flow rate among input sources. Total COD, BOD, DIN and DIP loadings in January were about 896kg/d, 718kg/d, 2,152kg/d, and 154kg/d, respectively, which exceeded those of October. Lower POC/TOC levels are estimated in R2, and also in October. Temporal variation of pollutant loads were closely related to the human activity. Total discharging loadings of BOD, TN and TP by unit loading estimation were 4,993.0kg/d, 2,558.7kg/d, and 289.2kg/d, respectively, and were mainly affected by the population. Runoff ratio of BOD was about 0.14 in January Mean $NH_4^+_-N$ and $PO_4\;^{3-}-P$ loadings from sediment were 16.23mg/$m^2$/d and 7.26mg/$m^2$/d, respectively. For the improvement of water quality in this area, not only pollutant loads of rivers and ditches but also benthic flux from sediment should be reduced within the limits of the environmental capacity.

Reuse of Weaving Wastewater by Membrane Bioreactor Equipped with a Hollow-fiber MF Membrane (중공사 정밀여과 MBR공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.365-369
    • /
    • 2004
  • Submerged membrane bio-reactor equipped with a hollow fiber microfiltration was applied to reuse weaving wastewater of water jet loom, where two parameters such as the concentration of MLSS and the flux were controlled. While the flux at the concentration of MLSS around 900mg/L was constantly kept over 0.4m/d and 0.8m/d in a short time, the stable flux at around 300mg/L of MLSS was shown at the 8 days later. Regardless of MLSS and flux, BOD, CODcr and Turbidity of the permeate were 1~2mg/L, 7~10mg/L and below 1 NTU, which were 85~90%, 87~90% and 98% of removal efficiency, respectively. The stable operation without fouling was achieved because the contents of ECP were smaller than those of common MBR processes and the composition(saccharide/protein) was kept constantly. In this study, 0.5~1.0m/d of flux and 400~900mg/L of MLSS were considered as the most recommendable operating condition for the reuse of weaving wastewater.

A Study on the Effect of the Development of Anaerobic Respiration Processes in the Sediment with the Water-column Stratification and Hypoxia and Its Influence on Methane at Dangdong Bay in Jinhae, Korea (진해 당동만의 성층과 빈산소에 따른 퇴적물내 혐기층 발달이 메탄 거동에 미치는 영향 연구)

  • Kim, Seoyoung;An, Soonmo
    • Ocean and Polar Research
    • /
    • v.44 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • Hypoxia can affect water-atmosphere methane flux by controlling the production and consumption processes of methane in coastal areas. Seasonal methane concentration and fluxes were quantified to evaluate the effects of seasonal hypoxia in Dangdong Bay (Gyeongsangnamdo, Jinhae Bay, South Korea). Sediment-water methane flux increased more than 300 times during hypoxia (normoxia and hypoxia each 6, 1900 µmol m-2 d-1), and water-atmospheric methane flux and bottom methane concentration increased about 2, 10 times (normoxia and hypoxia each 190, 420 µmol m-2 d-1; normoxia and hypoxia each 22, 230 nM). Shoaling of anaerobic decomposition of organic matter in the sediments during the hypoxia (August) was confirmed by the change of the depth at which the maximum hydrogen sulfide concentration was detected. Shoaling shortens the distance between the water column and methanogenesis section to facilitate the inflow of organic matter, which can lead to an increase in methane production. In addition, since the transport distance of the generated methane to the water column is shortened, consumption of methane will be reduced. The combination of increased production and reduced consumption could increase sediment-aqueous methane flux and dissolved methane, which is thought to result in an increase in water-atmospheric methane flux. We could not observe the emission of methane accumulated during the hypoxia due to stratification, so it is possible that the estimated methane flux to the atmosphere was underestimated. In this study, the increase in methane flux in the coastal area due to hypoxia was confirmed, and the necessity of future methane production studies according to oxygen conditions in various coastal areas was demonstratedshown in the future.