• Title/Summary/Keyword: Flux-Flow

Search Result 1,680, Processing Time 0.023 seconds

Identification of primary input parameters affecting evacuation in ventilated main control room through CFAST simulations and application of a machine learning algorithm to replace CFAST model

  • Sumit Kumar Singh;Jinsoo Bae;Yu Zhang;Saerin Lim;Jongkook Heo;Seoung Bum Kim;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3717-3729
    • /
    • 2024
  • Accurately predicting evacuation time in a ventilated main control room (MCR) during fire emergencies is crucial for ensuring the safety of personnel at nuclear power plants. This study proposes to use neural networks alongside consolidated fire and smoke transport (CFAST) simulations to serve as a surrogate model for physics-based simulation tools. Our neural networks can promptly predict the evacuation time in MCRs, proving to be a valuable asset in fire emergencies and eliminating the need for time-consuming rollouts of the CFAST simulations. The CFAST model simulates fire and evacuation scenarios in a ventilated MCR with variations in input parameters such as door conditions, ventilation flow rate, leakage area, and fire propagation time. Target output parameters, such as hot gas layer temperature (HGLT), heat flux (HF), and optical density (OD), are used alongside standardized evacuation variables to train a machine learning model for predicting evacuation time. The findings suggest that high ventilation flow rates help to dilute smoke and discharge hot gas, leading to lower target output parameters and quicker evacuation. Standardized evacuation variables exceed the required abandonment criteria for all door conditions, indicating the importance of proper evacuation procedures. The results show that neural networks can generate evacuation times close to those obtained from CFAST simulations.

Experimental Study of Pool Boiling for Enhancing the Boiling Heat Transfer by Hydrophobic Dots on Silicon Surface (실리콘 표면 위에 소수성 점을 이용한 비등 열전달 증진에 관한 실험적 연구)

  • Jo, Hang-Jin;Kim, Hyung-Mo;Ahn, Ho-Seon;Kang, Soon-Ho;Kim, Joon-Won;Shin, Jeong-Seob;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.655-663
    • /
    • 2010
  • Wettability is important to enhance not only CHF but also nucleate boiling heat transfer, as shown by the results of different kinds of boiling experiments. In this regard, an excellent boiling performance (a high CHF and heat transfer performance) could be achieved in the case of pool boiling by some favorable surface modifications that can satisfy the optimized wettability condition. To determine the optimized boiling condition, we design special heaters to examine how two materials, which have different wettabilities (e.g., hydrophilic and hydrophobic materials), affect the boiling phenomena. The special heaters have hydrophobic dots on a hydrophilic surface. The contact angle of the hydrophobic surface is $120^{\circ}$ to water at the room temperature. The contact angle of the hydrophilic surface is $60^{\circ}$ at same conditions. Experiments involving micro hydrophobic dots and two types of milli hydrophobic dots are performed, and the results are compared with a reference surface.

Oxygen Transfer System in Biological Fluidised Bed Using the Deep Shaft as Aeration Device (생물학적(生物學的) 유동층(流動層)을 이용(利用)한 폐수처리(廢水處理)에 있어서의 심층(深層) 폭기장치(曝氣裝置)에 의한 산소전달(酸素傳達) 시스템)

  • Kim, Hwan Gi;Ahn, Song Yeob;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.13-24
    • /
    • 1988
  • This paper is concentrated on the development of oxygen transfer system by U-tube deep shaft in biological fluidised bed process. The depth of the shaft is 32 m, it is composed of downcomer and riser. Not only flow pattern and oxygen transfer in the deep shaft but also oxygen limitation in biofilm and oxygen utilization in biological fluidised bed are investigated. In this investigation, driving force for liquid circulation in the deep shaft is affected by air injection depth and gas hold-up in downcomer. Flow pattern of the deep shaft is revealed to plug flow. When flow velocity in the deep shaft is maintained to 0.52 m/sec, $K_La$ value is peak at 25~30 m depth in riser. The efficiency of dissolved oxygen supply which passed from the deep shaft to biological fluidised bed is estimated to 56~81 % in the organic wastewater treatment using the deep shaft and when dissolved oxygen concentration is 9.2 mg/l and over, limiting factors of flux and substrate within biofilm are organic materials. Terefore, organic loadings could be increase without decreasing of BOD removal efficiency.

  • PDF

Secondary Flow Patterns of Liquid Ejector with Computational Analysis (액체상 이젝터의 2차측 액체 송출량 특성 전산해석)

  • Kwon, Kwisung;Yun, Jinwon;Sohn, Inseok;Seo, Yongkyo;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.183-190
    • /
    • 2015
  • An ejector is a type of non-powered pump that is used to supply a secondary flow via the ejection of a primary flow. It is utilized in many industrial fields, and is used for fueling the vehicle because of less failures and simple structure. Since most of ejectors in industry are gas-to-gas and liquid to gas ejector, many research activities have been reported in optimization of gas ejector. On the other hand, the liquid ejector is also applied in many industry but few research has been reported. The liquid ejector occurs cavitation, and it causes damage of parts. Cavitation has bees observed at the nozzle throat at the specified pressure. In this study, a two-dimensional axisymmetric simulation of a liquid-liquid ejector was carried out using five different parameters. The angle of the nozzle plays an important role in the cavitation of a liquid ejector, and the performance characteristics of the flow ratio showed that an angle of $35^{\circ}$ was the most advantageous. The simulation results showed that the performance of the liquid ejector and the cavitation effect have to be considered simultaneously.

A Study about Effectiveness and Usefulness of a FEM Slug Test Model (유한 요소기법을 이용한 Slug시험 모델의 타당성 및 유용성 연구)

  • 한혜정;최종근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.89-96
    • /
    • 2000
  • Slug tests are the most widely used field method for quantification of hydraulic conductivity of porous media. Well recovery is affected by well casing, borehole radii, screened length, hydraulic conductivity, and specific storage of porous media. In this study, a new slug tests model was developed through finite element approximation and the validity and usefulness of the model were tested in various ways. Water level fluctuation in a well under slug test and cons-equent groundwater flow in the surrounding porous medium were appropriately coupled through estimation of well-flux using an iteration technique. Numerical accuracy of the model was verified using the Cooper et al. (1967) solution. The model has advantages in simulations for monitored slug tests, partial penetration, and inclusion of storage factor. Volume coverage of slug tests is significantly affected by storage factor. Magnitude and speed of propagation of head changes from a well increases as storage factor becomes low. It will be beneficial to use type curves of monitored head transients in the surrounding porous formation for estimation of specific storage. As the vertical component of groundwater flow is enhanced, the influence of storage factor on well recovery decreases. For a radial-vertical flow around a partially penetrated well, deviations between hydraulic estimates by various methods and data selection of recovery curve are negligible on practical purposes, whereas the deviations are somewhat significant for a radial flow.

  • PDF

Control of Membrane Fouling in Submerged Membrane Bioreactor(MBR) using Air Scouring (침지형 생물 반응기 공정에서 플럭스 향상을 위한 공기 세척 효과에 관한 연구)

  • Shin, Dong-Hwan;Baek, Byung-Do;Chang, In-Soung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.948-954
    • /
    • 2008
  • Membrane bioreactor(MBR) processes have been widely applied to wastewater treatment for last decades due to its excellent capability of solid-liquid separation. However, membrane fouling was considered as a limiting factor in wide application of the MBR process. Excess aeration into membrane surface is a common way to control membrane fouling in most MBR. However, the excessively supplied air is easily dissipated in the reactor, which results in consuming energy and thus, it should be modified for effective control of membrane fouling. In this study, cylindrical tube was introduced to MBR in order to use the supplied air effectively. Membrane fibers were immersed into the cylindrical tube. This makes the supplied air non-dissipated in the reactor so that membrane fouling could be controlled economically. Two different air supplying method was employed and compared each other; nozzle and porous diffuser which were located just beneath the membrane module. Transmembrane pressure(TMP) was monitored as a function of airflow rate, flux, and ratio of the tube area and cross-sectioned area of membrane fibers(A$_m$/A$_t$). Flow rate of air and liquid was regulated to obtain slug flow in the cylindrical tube. With the same flow of air supply, nozzle was more effective for controlling membrane fouling than porous diffuser. Accumulation of sludge was observed in the tube with the nozzle, if the air was not suppled sufficiently. Reduction of membrane fouling was dependent upon the ratio, A$_m$/A$_t$. For diffuser, membrane fouling was minimized when A$_m$/A$_t$ was 0.27, but 0.55 for nozzle.

Numerical Experiments of Coastal Upwelling Occurred by Summer Winds in the East Sea of Korea (한국 동해 연안에서 하계 바람에 의해 발생하는 연안용승에 관한 수치실험)

  • Seo, Ho-San;Lim, Woo-Hyun;Kim, Dong-Sun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.4
    • /
    • pp.347-353
    • /
    • 2017
  • In this study, numerical experiments were conducted to identify distribution of rising flow and flux in the East Sea of Korea, where the coastal upwelling occurs. Temperature and salinity data from CTD observations and NIFS during summer 2013 were applied to the model. Numerical experiments were carried out with different wind speed (3, 6 m/s and 9 m/s) and direction (southerly and southwesterly), which represent the most frequent in summer conditions. As a result of calculation, upwelling flow rate was found to be highest in Pohang between five coasts(Hupo, Youngduk, Pohang, Ulsan and Busan). Comparing with southerly wind conditions, the rising flow rate is about 1.5 times greater when southwesterly wind was applied. Horizontal diffusion of the upwelling area is expected to have a speed of 17~22 km/day when a 9 m/s southwesterly wind is applied. If this wind continues over one week, a cold pool will be generated by upwelling that may reach to the Ulleung area.

Analysis of the Characteristics of the River Bed Variation by Flow Direction Changes at a Channel Junction (합류부내에서 유로 흐름방향 변경에 따른 하상변화 특성 분석)

  • Choi, Gye-Woon;Ahn, Kyung-Hoon;Jung, Jae-Kawng
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.117-124
    • /
    • 2010
  • Most of the rivers which exist in nature are not a single river but the network that is composed of several branches and mainstreams. The river network are more complicated than other sigle rivers and streams. Therefore the hydraulic characteristics are sensitively changed by reduction and expansion of the width in the confluence or the variation of the flux. In this paper, the hydraulic characteristics were calculated by the change of the width and length in the confluence and the hydraulic model test. The deposit of confluence emerged at the left bank, right bank and the stagnation sector. As the total flow in the branch have increased, stagnation of the left bank and right bank have decreased. When the width of the downstream have been get smaller from 3 m to 2 m, the deposit of the left bank and right bank and stagnation sector have decreased. But as the eddy flow in the center of the confluence is occurred, the erosion has been increased. The result of this paper can be used as a basic data of water management around the junction and for maintenance on the ground of development of the river.

A Study on the Optimization of Heat Flux in Engine Room of Auxiliary Power Unit for Self-Propelled Artillery (자주포용 보조동력장치 엔진룸의 열유동 최적화에 관한 연구)

  • Noh, Sang Wan;Park, Young Min;Kim, Sung Hoon;Lee, Jae Dong;Kim, Byung Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.629-635
    • /
    • 2019
  • In this study, we analyzed the effect of FAN and oil cooler application on APU. MIL-STD-810 was applied to the atmospheric environment and radiation dose in order to perform thermal flow analysis. The heat flow was analyzed for the case in which the inlet / outlet fan was applied (Case 1), the case in which the inlet fan and the oil cooler were applied (Case 2), and the case in which the inlet / outlet fan and the oil cooler were applied (Case 3). As a result, it was confirmed that the cylinder head temperature of Case 3 was 21.4 times lower than that of Case 1 and 8.0 times lower than that of Case 2. Experiments were conducted under the same ambient conditions in order to examine the validity of the results. The numerical values and experimental results showed a difference of less than 7%. Through this, we were able to confirm that the APU heat flow optimization model satisfies the design conditions. The results of this study are expected to be used as basic data for optimizing heat flow of APU.

Seepage Behavior with Unsaturated Soil-Water Characteristic in Reclaimed Deep Excavation Area (해안매립지 대심도 굴착지역의 불포화 함수특성에 따른 침투류 거동)

  • Shin, Bang-Woong;Lee, Heung-Gil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.4
    • /
    • pp.47-58
    • /
    • 2005
  • Development of underground space is conducted for various useful facility and underground structures and deep excavation technology for reclaimed area has been researched and developed. The seepage flow and behavior of phreatic line in reclaimed area was predominated by transient flow caused by tidal action. Also the soil-water characteristic relation is most important factor for transient flow analysis, therefore the research about the soil-water characteristic is strongly required. In this paper, laboratory tests (pressure cell, desiccator, and tensiometer test) and theoretical analysis were performed to investigate the soil-water characteristic such as air-entry value, metric suction, and residual water content. And the feasibility of prediction method for soil-water characteristic are presented by transient seepage analysis and comparison between analysis results and in-situ measured seepage flux in LNG TK-00 storage tank. Based on the result of laboratory and theoretical analysis, Fredlund and Xing's method provide to work out well for reclaimed ground soils. Also, the transient analysis result is more reasonable and effective for design of deep excavation work in coastal and reclaimed ground.

  • PDF