• 제목/요약/키워드: Flux tower

검색결과 107건 처리시간 0.02초

실제증발산 자료의 불확실성 파악에 관한 연구: flux tower, 인공위성 및 재분석자료 (A study on the analyzing of uncertainty for actual evapotranspiration: flux tower, satellite-based and reanalysis based dataset)

  • 백종진;정재환;박종민;최민하
    • 한국수자원학회논문집
    • /
    • 제52권1호
    • /
    • pp.11-19
    • /
    • 2019
  • 본 연구에서는 인공위성 및 재분석 자료인 Global Land Data Assimilation System (GLDAS), Global Land Evaporation Amsterdam Model (GLEAM), MOD16의 실제증발산량 산출물을 활용하여 한국수자원조사기술원(Korea Institute of Hydrological Survey, KIHS)에서 관리하고 있는 청미천(cheongmicheon farmland site, CFK)과 설마천(seolmacheon site, SMK) flux tower에서 검증하였고, Triple collocation (TC) 방법을 활용하여 자료간의 불확실성 및 상관성분석을 수행하였다. 플럭스타워와의 검증 결과에서는 전반적으로 GLEAM>GLDAS>MOD16순으로 좋은 결과를 나타내었으며, 세가지 산출물의 조합(S1: flux tower vs. GLDAS vs. MOD16, S2: flux tower vs. GLDAS vs. GLEAM, S3: flux tower vs. GLEAM vs. MOD16)을 통한 TC 결과에서는 청미천(설마천)에서 GLEAM>GLDAS>MOD16>flux tower (GLDAS>GLEAM>MOD16>flux tower)순으로 좋은 결과를 나타내었다. TC 분석 결과에서 Flux tower의 error variance와 correlation coefficient가 상대적으로 좋은 결과를 나타내지 못하였으므로, 한반도 지역에서 인공위성과 재분석 자료(GLDAS vs. GLEAM vs. MOD16)만을 활용하여 TC를 적용하였다. 그 결과, GLDAS와 GLEAM이 한반도 영역에서 낮은 error variance 와 높은 correlation coefficient를 나타낸 반면, MOD16의 경우, 농지에서 낮은 correlation coefficient과 높은 error variance를 나타내었다.

타워형 태양열발전을 위한 열유속 분포 측정기술 개발 (Development of Flux Mapping Technique for the Solar Power Tower Plant)

  • 채관교;이현진;김종규;윤환기;이상남;강용혁;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.274-279
    • /
    • 2012
  • Daegu Solar Power Tower Plant of 200 kW thermal capacity was developed for the first time in Korea, 2011. Measurement of the heat flux distribution is essential to evaluate the solar energy concentrated by reflectors and to design a suitable receiver. The flux mapping technique, which uses a radiometer and a diffuse plate, is common for measurement of the heat flux distribution. Because the solar power tower plant has a wide concentration area, the flux mapping technique using a fixed diffuse plate is difficult to apply. Therefore, the flux distribution in the solar power tower plant should be measured by the flux mapping technique using a small moving bar. In this study, we measured flux distributions with the moving-bar system developed at the KIER solar furnace and evaluated its applicability for the solar power tower plant.

  • PDF

FK KoFlux 관측지에서의 지역 규모 열 플럭스의 추정 : 타워 관측에서 MM5 중규모 모형까지 (Inferring Regional Scale Surface Heat Flux around FK KoFlux Site: From One Point Tower Measurement to MM5 Mesoscale Model)

  • Jinkyu Hong;Hee Choon Lee;Joon Kim;Baekjo Kim;Chonho Cho;Seongju Lee
    • 한국농림기상학회지
    • /
    • 제5권2호
    • /
    • pp.138-149
    • /
    • 2003
  • KoFlux는 생태계와 대기 사이에 교환되는 이산화탄소, 수증기 및 에너지에 대한 우리의 이해를 높이고, FLUXNET과 CEOP등의 지역, 대륙 및 전구 규모의 관측망에 기여하기 위해서 시작되었다. 그거나 한반도의 지형적 특성 때문에 KoFlux의 대부분의 플럭스 타워는 관측에 이상적이지 못한 장소에 위치하고 있다. 탄소 및 에너지 교환의 정량화를 위해서 뿐만 아니라 군락 규모에서 지역 규모로 확장하기 위해서는 관측과 모델링을 병용한 다양한 접근 방법의 적용이 필요하다. 본 연구에서는 지역 규모의 현열 플럭스를 추정하기 위해 타워 플럭스 관측, 대류 경계층(CBL) 수지 방법, MM5 중규모 모형, 그리고 NCAR/NCEP 재분석 자료의 네 가지의 방법을 사용하여 다양한 면적을 대표하는 현열 플럭스를 산출하여 비교하였다. 비록 제한된 짧은 기간의 자료를 사용하였으나, 예비 분석을 통하여 (1) 해남 농경지 플럭스 타워에서 관측된 현열 플럭스가 지표의 불균질성을 보였고, (2) CBL 수지 방법으로 얻어진 지역 규모의 현열 플럭스는 수평 이류 효과의 계산 방법에 따라 다른 결과를 보였으며, (3) MM5 중규모 모형은 타워 플럭스 관측 값과 아주 유사한 현열 값을 수치 모사하였다. 그러나 관측지의 불균질성과 두 방법이 대표하는 면적의 근본적인 차이를 고려할 때, 플럭스 발자국 분석, 지리정보 시스템 및 관측지의 위성 영상 분석에 근거한 타워 플럭스의 공간 대표성을 정량화하는 것이 시급한 것으로 나타났다.

Membrane distillation of power plant cooling tower blowdown water

  • Ince, Elif;Uslu, Yasin Abdullah
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.321-330
    • /
    • 2019
  • The objective of this study was to examine the recovery of the power plant cooling tower blowdown water (CTBD) by membrane distillation. The experiments were carried out using a flat plate poly vinylidene fluoride (PVDF) membrane with a pore diameter of $0.22{\mu}m$ by a direct contact membrane distillation unit (DCMD). The effects of operating parameters such as transmembrane temperature difference (${\Delta}T$), circulation rate and operating time on permeate flux and membrane fouling have been investigated. The results indicated that permeate flux increased with increasing ${\Delta}T$ and circulation rate. Whereas maximum permeate flux was determined as $47.4L/m^2{\cdot}h$ at ${\Delta}T$ of $50^{\circ}C$ for all short term experiments, minimum permeate flux was determined as $7.7L/m^2{\cdot}h$ at ${\Delta}T$ of $20^{\circ}C$. While $40^{\circ}C$ was determined as the optimum ${\Delta}T$ in long term experiments. Inorganic and non-volatile substances caused fouling in the membranes.

플럭스 타워 설치 유역을 대상으로 탄소수지 분석을 위한 위성영상자료기반의 CO2 정량화 연구 (Quantitative Study of CO2 based on Satellite Image for Carbon Budget on Flux Tower Watersheds)

  • 정충길;이용관;김성준;장철희
    • 한국농공학회논문집
    • /
    • 제57권3호
    • /
    • pp.109-120
    • /
    • 2015
  • Spatial heterogeneous characteristics of solar radiation energy from Climate Change gives rise to energy imbalance in the general ecological system including water resources. This study is to estimate the $CO_2$ flux of South Korea using Terra MODIS image and to assess the reliability of MODIS data from the ground measured $CO_2$ flux by eddy covariance flux tower data at 3 locations (two at mixed forest area and one at rice paddy area). The MODIS Gross Primary Productivity (GPP) product (MOD17A2), 8-day composite at 1-km spatial resolution was adopted for the spatial $CO_2$ flux generation. The MOD17A2 data by noise like cloud and snow in a day were tried to fill by Inverse Distance Weighted (IDW) method from valid pixels and the damping effect of MOD17A2 data were corrected by Quality Control (QC) flag. The MODIS $CO_2$ flux was estimated as the sum of GPP and Re (ecosystem respiration) by Lloyd and Taylor method (1994). The determination coefficient ($R^2$) between MODIS $CO_2$ and flux tower $CO_2$ for 3 years (2011~2013) showed 0.55 and 0.60 in 2 mixed forests and 0.56 in rice paddy respectively. The $CO_2$ flux generally fluctuated showing minus values during summer rainy season (from July to August) and maintaining plus values for other periods. The MODIS $CO_2$ flux can be a useful information for extensive area, for example, as a reliable indicator on ecological circulation system.

설마천 유역 CO2 Flux 실측 자료에 의한 총일차생산성 (GPP)과 MODIS GPP간의 비교 평가 (Evaluation of MODIS Gross Primary Production (GPP) by Comparing with GPP from CO2 Flux Data Measured in a Mixed Forest Area)

  • 정충길;신형진;박민지;조형경;김성준
    • 한국농공학회논문집
    • /
    • 제53권2호
    • /
    • pp.1-8
    • /
    • 2011
  • In this study, In order to evaluate reliable of MODIS GPP, the MODIS GPP and Flux tower measured GPP were compared to evaluate the use of method on 8 days composite MODIS GPP. The 2008 Flux data ($CO_2$ Flux and air temperature) measured in Seolmacheon watershed ($8.48\;km^2$) were used. The Flux tower GPP was estimated as the sum of $CO_2$ Flux and $R_{ec}$ (ecosystem respiration) by Lloyd and Taylor method (1994). The summer Monsoon period from June to August mostly contributed the underestimation of MODIS GPP by cloud contamination on MODIS pixels. The 2008 MODIS GPP and Flux tower GPP of the watershed were $1133.2\;g/m^2/year$ and $1464.3\;g/m^2/year$ respectively and the determination coefficient ($R^2$) after correction of cloud-originated errors was 0.74 (0.63 before correction). Even though effect of Cloud-Originated Errors was eliminated, Solar radiation and Temperature are affected at GPP. Measurement of correct GPP is difficult. But, If errors of MODIS GPP analyze on Cloud Moonsoon Climate in korea and eliminated effect of Cloud-Originated Errors, MODIS GPP will be considered GPP increasing of 9 %. There, Our results indicate that MODIS GPP show reliable and useful data except for summer period in Moonsoon Climate.

농림생태계와 대기간의 상호 작용 연구를 위한 에디 공분산 방법의 사용에 관하여 (On Using the Eddy Covariance Method to Study the Interaction between Agro-Forest Ecosystems and the Atmosphere)

  • 최태진;김준;윤진일
    • 한국농림기상학회지
    • /
    • 제1권1호
    • /
    • pp.60-71
    • /
    • 1999
  • The micrometeorological tower flux network is the cornerstone of the global terrestrial vegetation monitoring. The eddy covariance technique used for tower fluxes is derived from the conservation of mass and is most applicable for steady-state conditions over flat, extended, and uniform vegetation. This technique allows us to obtain surface fluxes of energy budget components, greenhouse and trace gases, and other pollutants. The quality-controlled flux data are invaluable to validate various models with temporal scales ranging from minutes to years and spatial scales ranging from a few meters to hundreds of kilometers. In this paper, we review the theoretical background of this important eddy covariance technique, examine the measurement criteria and corrections, and finally suggest some measurement strategies that may facilitate coordinated flux measurements among different disciplines and provide a strong infrastructure for the global flux network.

  • PDF

북극 다산기지에서의 플럭스 발자취 기후도와 플럭스 자료 품질 (Flux Footprint Climatology and Data Quality at Dasan Station in the Arctic)

  • 이방용;최태진;이희춘;윤영준
    • 지구물리
    • /
    • 제8권4호
    • /
    • pp.201-205
    • /
    • 2005
  • Turbulent fluxes of heat, water vapor, and CO2 have been measured since August, 2003 at Dasan Station (78o 55’ N, 11o50’E) in the Arctic. These data can allow us to better understand the interactions between the Polar ecosystems and the atmosphere together with those at King Sejong Station in the Antarctic. Due to the buildings and measurement platforms around the flux tower, it is required to evaluate how they influence measured flux data. By using one-year turbulence statistics data and footprint model, flux footprint climatology was analyzed together with data availability. The upwind distance of source area ranged from 150 to 300 m, where the buildings and measurement platforms existed. However, flow distortion due to them may be not a major factor to reduce the data availability significantly. Based on, the dominant wind direction of SW and footprint climatology, the location of flux tower is considered suitable for flux measurement.

  • PDF

에디공분산 방법 기반의 플럭스 타워 순 복사에너지 검증: 설마천, 청미천 유역 (Validation of Net Radiation Measured from Fluxtower Based on Eddy Covariance Method: Case Study in Seolmacheon and Cheongmicheon Watersheds)

  • 변규현;신지예;이연길;최민하
    • 한국수자원학회논문집
    • /
    • 제46권2호
    • /
    • pp.111-122
    • /
    • 2013
  • 최근 들어 기후변화로 인해 물과 에너지 순환에 관한 정확한 이해가 요구되고 있다. 현재 미기상학적 플럭스 타워 네트워크는 수문학적, 생태학적 분석에 있어서 주춧돌역할을 하고 있다. 하지만 플럭스 타워의 에디공분산 방법을 활용한 잠열 플럭스 측정은 여러 가정사항에 따른 시스템적 오류를 내포하고 있고 이에 따라 과소평가된 잠열 플럭스 원시자료의 보정이 필요하다. 몇몇의 보정방법 중 보엔비를 활용한 방법이 가장 유용한 방법 중 하나로서 여기에는 플럭스타워에서 측정한 순 복사에너지 및 기타 플럭스(현열, 지열) 등이 요구되며 이러한 자료에 대한 정확한 측정 및 검증이 필요하다. 본 연구에서는 설마천, 청미천 유역의 플럭스타워에서 측정된 순 복사에너지를 검증하기 위해 두 가지 형태의 이론적으로 계산된 순 복사에너지와의 비교검증을 실시하였다-(1) FAO 56 기반의 일평균 순 복사에너지 (2) Bastiaansen (1995)가 제안한 순간 순 복사에너지. 본 연구의 결과는 플럭스타워에서 측정된 순 복사에너지는 이론적으로 계산된 순 복사에너지와 상당히 비슷한 경향성을 보인다는 것을 제시했다. 또한, 측정된 순 복사에너지를 이용하여 관측된 잠열플럭스를 보엔비 보정방법에 적용시킨 결과 에너지수지에 더욱 부합하는 것을 알 수 있었다.

보성 농업지역에서의 장기간 플럭스 특성 분석 (Long Term Flux Variation Analysis on the Boseong Paddy Field)

  • 이영태;황성은;김병택;김기훈
    • 대기
    • /
    • 제34권1호
    • /
    • pp.69-81
    • /
    • 2024
  • In this paper, Annual flux variations in the Boseong Tall Tower (BTT) from 2016 to 2020 were analyzed using data from three levels (2.5 m, 60 m, and 300 m). BTT was installed in Boseong-gun, Jeollanam-do in February 2014 and continued to conduct energy exchange observations such as CO2, sensible heat, and latent heat using the eddy covariance method until March 2023. The BTT was located in a very flat and uniform paddy field, and flux observations were conducted at four levels: 2.5 m, 60 m, 140 m, and 300 m above ground. Surface energy balance was confirmed from observed data of net radiation flux, soil heat flux, sensible heat flux, and latent heat flux. Additionally, 2.5 m height surface fluxes, which are most influenced by agricultural land, were compared with data from Local Data Assimilation and Prediction System (LDAPS) of the Korea Meteorological Administration to evaluate the accuracy of LDAPS flux data. The correlation coefficient between LDAPS flux data and observed values was 0.95 or higher. Excluding summer latent heat flux data, there was a general tendency for LDAPS data to be higher than observed values. The footprint areas estimated below 60 m height mainly covered agricultural land, and flux observations at 2.5 m and 60 m heights showed typical agricultural characteristics. In contrast, the footprint estimated at 300 m height did not show agricultural characteristics, indicating that observations at this height encompassed a wide range, including mountains, sea, and roads. The analysis results of long-term flux observations can contribute to understanding the energy and carbon dioxide fluxes in agricultural fields. Furthermore, these results can be utilized as essential data for validating and improving numerical models related to such fluxes.