• Title/Summary/Keyword: Flux mapping method

Search Result 19, Processing Time 0.019 seconds

Presentation of a Novel E-Core Transverse-Flux Permanent Magnet Linear Motor and Its Magnetic Field Analysis Based on Schwarz-Christoffel Mapping Method

  • Fu, Dong-Shan;Xu, Yan-Liang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1963-1969
    • /
    • 2017
  • In order to overcome the manufacturing difficulty of the transverse-flux permanent magnet linear motor (TFPMLM) and enhance its performance much better, a novel TFPMLM with E-core and 3 dimension (3D) magnetic structures is proposed in this paper. Firstly, its basic structure and operating principle are presented. Then the equivalent 2D configuration of the TFPMLM is transformed, so that the Schwarz-Christoffel (SC) mapping method can be used to analyze the motor. Furthermore, the air gap flux density distribution is solved by SC mapping method, based on which, the EMF waveform, no-load cogging force waveform and load force waveform are obtained. Finally, the prototyped TLPMLM is manufactured and the results are obtained from the experiment and 3D FEM, respectively, which are used to compare with those from SC mapping method.

A Study of a Heat Flux Mapping Procedure to Overcome the Limitation of Heat Flux Gauges in Fire Tests (화재실험시 열유속 센서 사용의 단점을 보완한 Heat Flux Mapping Procedure에 관한 연구)

  • Choi, Keum-Ran
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.171-179
    • /
    • 2005
  • It is essential to understand the role of wall lining materials when they are exposed to a fire from an ignition source. Full-scale test methods permit an assessment of the performance of a wall lining material. Fire growth models have been developed due to the costly expense associated with full-scale testing. The models require heat flux maps from the ignition burner flame as input data. Work to date was impeded by a lack of detailed spatial characterization of the heat flux maps due to the use of limited instrumentation. To increase the power of fire modeling, accurate and detailed heat flux maps from the ignition burner are essential. High level spatial resolution for surface temperature can be provided from an infrared camera. The objective of this study was to develop a heat flux mapping procedure for a room test burner flame to a wall configuration with surface temperature information taken from an infrared camera. A prototype experiment was performed using the ISO 9705 test burner to demonstrate the developed heat flux mapping procedure. The results of the experiment allow the heat flux and spatial resolutions of the method to be determined and compared to the methods currently available.

Study on magnetic field mapping within cylindrical center volume of general magnet

  • Huang, Li;Lee, Sangjin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.30-36
    • /
    • 2016
  • For the magnetic field analysis or design, it is important to know the behavior of the magnetic field in an interesting space. Magnetic field mapping becomes a useful tool for the study of magnetic field. In this paper, a numerical way for mapping the magnetic field within the cylindrical center volume of magnet is presented, based on the solution of the Laplace's equation in the cylindrical coordinate system. The expression of the magnetic field can be obtained by the magnetic flux density, which measured in the mapped volume. According to the form of the expression, the measurement points are arranged with the parallel cylindrical line (PCL) method. As example, the magnetic flux density generated by an electron cyclotron resonance ion source (ECRIS) magnet and a quadrupole magnet were mapped using the PCL method, respectively. The mapping results show the PCL arrangement method is feasible and convenience to map the magnetic field within a cylindrical center volume generated by the general magnet.

Indirect Detection of Rotor Position of Switched Reluctance Motor Based on Flux Linkage Analytic Model

  • Zhou, Yongqin;Hu, Bo;Wang, Hang;Jin, Ningzhi;Zhou, Meilan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.829-837
    • /
    • 2018
  • In this paper, a flux linkage model based on four magnetization curves fitting is proposed for three-phase 12/8 switched reluctance motor (SRM), with the analysis of the basic principle of flux detection method and function analysis method. In the model, the single value function mapping relationship between position angle and flux is established, which can achieve a direct estimation of rotor position. The realization scheme of SRM indirect position detection system is presented. It is proved by simulation and experiment that the proposed scheme is suitable for rotor position detection of SRM, and has high accuracy of position estimation.

Optical Characterization of a High-Flux Solar Thermal Simulator (고집광 태양열 시뮬레이터의 광학 특성 평가)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Yoon, Hwan-Ki;Kim, Jong-Kyu;Kang, Yong-Heack;Lee, Sung-Wook
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.65-71
    • /
    • 2015
  • A solar thermal simulator is suitable for indoor experiments of solar receivers and reactors when solar insolation and weather conditions are not favorable. Moreover, due to the easy control of electric power input, the solar thermal simulator allows the adjustment of power input incident on solar receivers and reactors and thus the implementation of accurate experiments. We manufactured a solar simulator, which is comprised of three sets of a xenon lamp and an elliptical reflector. In order to serve as a test facility, optical characterization of the solar simulator via radiation heat flux measurement is a critical prerequisite. We applied the flux mapping method to measuring the heat flux distribution of the three lamps. We presented the measurement results in terms of the heat flux distribution, the peak heat flux, the power distribution, the maximum power, and the efficiency for electric power conversion into radiation power. Characterization results show that our solar simulator provides the peak heat flux of $3,019kW/m^2$, the maximum power of 16.9 kW, and the conversion efficiency of 45%, additionally with a 10% operation margin for output increase.

Estimating the urban radiation heat flux distribution and the reduction effect of building and tree shade (건물과 수목의 그림자에 의한 도시의 열 분포 산정 및 저감효과 연구)

  • Park, Chae-Yeon;Lee, Dong-Kun;Yoon, June-Ha
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.21 no.6
    • /
    • pp.1-13
    • /
    • 2018
  • Mapping radiation heat flux of urban area is essential for urban design and landscape planning. Because controlling urban geometry and generating green space are important urban design strategies for reducing urban heat, urban planner and designer need to recognize the micro urban heat distribution for adequate urban planning. This study suggests a new methodology for mapping urban radiation heat flux in a micro scale considering buildings and trees' shade. For doing that, firstly, we calculate net radiation for each urban surfaces (building, road (not shaded, building shaded, tree shaded), ground (not shaded, building shaded, tree shaded), tree (not shaded, building shaded)). Then, by multiplying the area ratio of surfaces to the net radiation, we can obtain the radiation heat flux in micro-scale. The estimated net radiation results were found to be robust with a $R^2$ of 90%, which indicates a strong explanatory power of the model. The radiation heat flux map for 12h $17^{th}$ August explains that areas under the building and tree have lower net radiation heat flux, indicating that shading is a good strategy for reducing incident radiation. This method can be used for developing thermal friendly urban plan.

Flux Density Distribution of the Dish Solar Concentrator (KIERDISH II) (KIERDISH II 태양열 집광시스템의 플럭스밀도 분포)

  • Kang, Myeong-Cheol;Kang, Yong-Heack;Yoo, Seong-Yeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.11-18
    • /
    • 2004
  • A solar concentrator, named KIERDISH II, was built at KIER in order to investigate the feasibility of high temperature solar energy application system. The constructed concentrator is a dish type solar concentrator with a focal length of 4.68m and a diameter of 7.9m. To successfully operate KIERDISH II, optimal design of the absorber is very important and flux density distribution has to be known. The focal flux density distribution on the receiver was measured. We have observed the shape and size of flux images and evaluated percent power within radius. Flux density distribution is usually measured by a CCD(charge coupled device) camera and a radiometer. In this paper we present a flux mapping method to estimate the characteristic features of the flux density distribution in the focal region of solar concentrator. The minimum radius of receiver is found to be 0.15m and approximately 90% of the incident radiation is intercepted by receiver aperture.

Effect of stacking sequence on thermal stresses in laminated plates with a quasi-square cutout using the complex variable method

  • Chaleshtari, Mohammad H. Bayati;Khoramishad, Hadi
    • Structural Engineering and Mechanics
    • /
    • v.77 no.2
    • /
    • pp.245-259
    • /
    • 2021
  • In this research, the influence of the laminate stacking sequence on thermal stress distribution in symmetric composite plates with a quasi-square cutout subjected to uniform heat flux is examined analytically using the complex variable technique. The analytical solution is obtained based on the thermo-elastic theory and the Lekhnitskii's method. Furthermore, by employing a suitable mapping function, the solution of symmetric laminates containing a circular cutout is extended to the quasi-square cutout. The effect of important parameters including the stacking sequence of laminates, the angular position, the bluntness, the aspect ratio of cutout, the flux angle and the composite material are examined on the thermal stress distribution. It is found out that the circular shape for cutout may not necessarily be the optimum geometry for all stacking sequences. The finite element analysis results are used to validate the analytical solution.

Concentration Error Assessment by Comparison of Solar Flux Measurement and Modeling (집광 열유속 측정과 모델링의 비교를 통한 집광 오차 평가)

  • Chai, Kwan-Kyo;Yoon, Hwan-Ki;Lee, Hyun-Jin;Lee, Seong-Uk;Kim, Si-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.82-90
    • /
    • 2013
  • Concentration errors critically affect the performance of solar concentrator, so their evaluation is important to the concentrated solar power technology. However, the evaluation is very challenging because error sources are various and not easy to measure individually. Therefore, the integrated effect of concentration errors is often more interesting and useful for large-scale applications. In the present work, we analytically investigate and classify various concentration error sources and then explain that the effect of various concentration errors can be represented in terms of a root mean square value of reflector surface slope error. We present an indirect approach to assessing the reflector surface slope error by comparing solar flux measurement data with modeling calculations. We apply the approach for solar furnaces with different thermal capacity and investigate its advantages and disadvantages.

Modeling approach in mapping groundwater vulnerability

  • Im Jeong-Won;Bae Gwang-Ok;Lee Gang-Geun;Seok Hui-Jun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.304-307
    • /
    • 2005
  • A numerical modelling method using a backward-in-time advection dispersion equation is introduced in assessing the vulnerability of groundwater to contaminants as an alternative to classical vulnerability mapping methods. The flux and resident concentration measurements are normalized by the total contaminants mass released to the system to provide the travel time probability density function and the location probability function. With the results one can predict the expected travel time of a contaminant from up stream location to a well and also the relative concentration of the contaminant at a well. More specific groundwater vulnerability can be mapped by these predicted measurements.

  • PDF