• Title/Summary/Keyword: Flux harmonics

Search Result 103, Processing Time 0.061 seconds

Analysis of Flux Weakening Operating Regions for a PM Synchronous Motor in HEV by considering Back EMF Harmonics (HEV용 영구자석동기전동기의 유기전압 고조파를 고려한 약자속 운전 영역해석)

  • Cho, Kwan-Yuhl;Woo, Byung-Guk;Kim, Gyoung-Man;Kang, Chan-Ho;Shin, Hee-Keun;Yoon, Byung-Chul;Park, Min-Gyu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.152-161
    • /
    • 2011
  • An interior permanent magnet synchronous motor(IPMSM) has been applied to the electric vehicle due to its high efficiency, compact volume, and wide operating speed ranges. This paper presents the analysis of the flux weakening operating regions at high speeds for the IPMSM that has back emf harmonics. The effect of the back emf harmonics on the motor speed and the maximum torque is analyzed. Also the dq currents for maximum torque operation under the voltage and the current limit conditions are analyzed. The conventional analysis and the presented analysis for the flux weakening operating regions are compared and the maximum torque - speeds characteristics for both analysis are verified through the experiment.

The Study On Analysis Of The Characteristics For Capacitor Motor Having Space Harmonics In Its Magnetic Field (공간고주파자속을 가진 콘덴서 전동기의 특성해석에 관한 연구)

  • Keung Yul Oh
    • 전기의세계
    • /
    • v.24 no.1
    • /
    • pp.29-42
    • /
    • 1975
  • In this paper, the electrical angle between two winding axes in the stator of the capacitor motor is put optional angle, deviding the space harmonics in its magnetic field of two windings and the leakage flux into the forward revolving field and the backward one by the revolving-field theory, its equivalent circuit which consider mutual induction between two windings is depicted. In the depicted equivalent circuit, the rotor resistance for the fundamental flux is devided into the resistance for the rotor bar and endring, and the rotor leakage reactance for the fundamental is devided into the skew leadage reactance and the other, and each circuit constants for each harmonics is expressed in terms of the circuit constants for the fundamental, so it mades easy to determine the characteristics for the capacitor motor. As the circuit constant ratios to the magnetizing reactance of the fundamental are used, motors which have same circuit constant ratios should be resembled in their characteristics.

  • PDF

Effect of IPMSM d-q Axis Parameters According to Magnetic Saturation and Armature Reaction

  • Jang, Kibong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.539-544
    • /
    • 2015
  • FEA was used to analyze inductance and torque of IPMSM. Torque and inductance are analyzed on the dq-axis. It was shown that Ld and Lq have harmonic components, and magnitude as well as phase of the harmonics varies according to the current values. This paper shows the relationship between these inductance harmonics and the 6th harmonic component of torque.

Analysis of Single-phase Induction Motor Having Space Harmonics in Its Magnetic Field (고주파자속을 고려한 단순상유도전동기의 해석)

  • Keung Yul Oh
    • 전기의세계
    • /
    • v.22 no.3
    • /
    • pp.25-34
    • /
    • 1973
  • In this paper, the characteristics of a single phase induction motor which is considered the space harmonic flux by the double revolving field theory is analysed. As the rotor resistance for the fundamental flux is separated from the resistance for the rotor bar and end-ring, and the rotor leakage reactnace is separated from the skew leakage reactance and the other, so the circuit constants for the space harmonic flux is expressed by the circuit constants for the fundamentals. As the ratio of the circuit constants for the magnetizing reactance is used, the generalized equivalent circuit is made up. the characteristic equation which is able to analysis the subdivided characteristics by the above circuit is induced. The ratio of the circuit constants and the skew angle being changed, the variations of the torque-speed characteristics for the fundamentals and harmonics is examined by this equation.

  • PDF

Design Characteristics of Torque Harmonics Reduction of Induction Motors for Electric Vehicle Propulsion

  • Jeon, Kyung-Won;Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.212-215
    • /
    • 2013
  • This paper deals with torque harmonic characteristics and its reduction design of induction motors for electric vehicle (EV) propulsion. For calculating the stator harmonic flux of squirrel-cage induction motor, the numerical methods have been employed on the structural configuration design of stator and rotor teeth. In particular, torque ripples including spatial harmonics are obtained by Finite Element Method (FEM), and their individual harmonic components are identified with Fast Fourier Transform (FFT). In this paper, design modification on the teeth surface gives rise to the significant reduction of torque ripples including spatial torque harmonics, which have been obtained with FEM.

To examine of management standard by the harmonics measured and analyzed in water supply field (수도사업장 고조파 측정, 분석을 통한 관리기준 만족여부 조사)

  • Hong, Sung-Taek;Lee, Eun-Chun;Shin, Gang-Wook;Lim, Jae-Il
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.296-298
    • /
    • 2003
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occured occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power Quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

to examine of management standard by the harmonics measured and analyzed in 22.9kV Power lines (22.9kV 수용가 전력계통별 고조파 발생실태 및 관리기준 조사분석)

  • Lee Eun Chun;Shin Gang Wook;Hong Sung Taek;Hong Young Jae;Park Young Chun;Lim Jae Il
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.270-272
    • /
    • 2004
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occurred occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

Harmonics Analysis of Air Gap Flux and Output Voltage in Generator Taking Account of the Rotor Movement (회전자 이동을 고려한 발전기 공극자속 및 유기전압의 고조파 해석)

  • Kim, C.E.;Jung, Y.B.;Yoon, S.J.;Park, B.S.;Ha, H.S.;Noh, C.W.;Kim, S.W.;Kim, J.H.;Im, D.H.;Ko, Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.205-207
    • /
    • 1994
  • This paper presents an analyzing method of the distortion factor of the output voltage in generator on the basis of the stator coil flux linkage calculation. In the simulation, 2 dimensional finite clement method is used considering the rotor movement. As an application of the proposed method, we calculated the harmonics of air gap flux and the output voltage in the 150KW class synchronous generator.

  • PDF

Analysis and Optimization of the Axial Flux Permanent Magnet Synchronous Generator using an Analytical Method

  • Ikram, Junaid;Khan, Nasrullah;Junaid, Qudsia;Khaliq, Salman;Kwon, Byung-il
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.257-265
    • /
    • 2017
  • This paper presents a 2-D analytical method to calculate the back EMF of the axial flux permanent magnet synchronous generator (AFPMSG) with coreless stator and dual rotor having magnets mounted on both sides of rotor yoke. Furthermore, in order to reduce the no load voltage total harmonics distortion (VTHD), the initial model of the coreless AFPMSG is optimized by using a developed analytical method. Optimization using the 2-D analytical method reduces the optimization time to less than a minute. The back EMF obtained by using the 2-D analytical method is verified by a time stepped 3-D finite element analysis (FEA) for both the initial and optimized model. Finally, the VTHD, output torque and torque ripples of both the initial and optimized models are compared with 3D-FEA. The result shows that the optimized model reduces the VTHD and torque ripples as compared to the initial model. Furthermore, the result also shows that output torque increases as the result of the optimization.

Direct Torque Control according to Flux and Torque of Hysterisis Band (자속 및 토오크 히스테리시스 밴드폭에 따른 직접토오크 제어)

  • Choi, Youn-Ok;Jeong, Sam-Yong;Kim, Dae-Gon;Kim, Pyung-Ho;Cho, Geum-Bae;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1206-1208
    • /
    • 2001
  • Direct torque control(DTC) of AC motor has the fast torque and flux dynamic responses even though it has very simple scheme to implement. DTC is also very simple in its implementation because it needs only two hysteresis comparators and switching vector table for both flux and torque control. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple, switching frequency and current harmonics. Therefore, authors analysis flux and torque hysteresis bands is suggested considering switching frequency and harmonic distortion of currents.

  • PDF