• Title/Summary/Keyword: Flushing flow

Search Result 86, Processing Time 0.031 seconds

Impact of a Flushing Discharge from an Upstream Dam on the NH3-N Concentrations during Winter Season in Geum River (상류 댐 플러싱 방류가 금강의 겨울철 암모니아성 질소 농도 저감에 미치는 효과분석)

  • Chung, Se Woong;Kim, Yu-kyung
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.609-616
    • /
    • 2005
  • A high ammonia nitrogen ($NH_3-N$) concentration has been recursively observed every winter season in Geum River, which hindered chemical treatment processes at a water treatment plant. A flushing discharge from Daecheong Dam was often considered to dilute $NH_3-N$, but information on the quantitative effect of flushing on the downstream water quality was limited. In this study, the impact of a short-term reservoir flushing on the downstream water quality was investigated through field experiments and unsteady water quality modeling. On November 22, 2003, the reservoir discharge was increased from $30m^3/sec$ to $200m^3/sec$ within 6 hours for the purpose of the experiment. The results showed that flushing flow tends to reduce downstream $NH_3-N$ concentrations considerably, but the effectiveness was limited by flushing amount and time. An unsteady river water quality model was applied to simulate the changes of nitrogen concentrations in response to reservoir flushing. The model showed very good performance in predicting the travel time of flushing flow and the effect of flushing discharge on the reduction of downstream $NH_3-N$ concentrations at Maepo and Geumnam site, but a significant discrepancy was observed at Gongju site.

Prediction of a Flushing Rate in an Embayment System for Construction of an Environmentally Sound Harbor (환경친화적 항만건설을 위한 항내 희석률 예측)

  • Jeong, Mi-Hoon;Park, Seok-Soon
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.215-228
    • /
    • 2000
  • This paper presents a novel method to predict a flushing rate in an embayment system, which can be utilized to assess an environmental impact caused by harbor construction. The method was successfully applied to the Ulsan-Onsan coastal area. The flushing rate was computed on the basis of water quality changes predicted by US Army Corps of Engineers' RMA-2/RMA-4 models. After calibration and verification to the measured tidal elevation and current velocity, the model was used to estimate the flushing rate in the proposed harbor. The water quality was simulated for 96 hours and the flushing rate was computed. The results indicated that the proposed harbor would significantly reduce the flushing rate in the Onsan harbor, especially at the small embayment area near the south breakwater. The flushing rate was evaluated for several alternatives, of which the tidal flow channel of 1,000 $m^2$ in the south pier appeared to be the best mitigation measure. This study proposes that the prediction of flushing rate would be a novel method to assess a water quality impact caused by harbor construction.

  • PDF

A study on the simulation method for the flushing flowrate and velocity in the watermain using a hydrant and a drain valve (소화전과 이토변을 이용한 플러싱 적용 시 관 내 세척유량과 유속 모의 방안에 관한 연구)

  • Gim, ARin;Lee, Eunhwan;Lee, SongI;Kim, kwang hyun;Jun, Hwandon
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1251-1260
    • /
    • 2022
  • Recently, due to the deterioration of watermains and the detachment of scale which is accumulated on the watermain surface, water quality accidents in a water supply network occur frequently. As scale accumulated on watermains is stabilized, it may not cause water quality accidents under the normal operating condition. However, due to water hammer or transient flow caused by the abrupt velocity and/or direction of flow change, it can be detached from the watermain surface resulting in water quality accidents. To prevent these kinds of water quality accidents, it is required to remove scale by watermain cleaning regularly. Many researches about flushing which is the most popular water cleaning method are focused on the desirable velocity criteria and the cleaning condition to accomplish the effect of flushing whereas less amount of research effort is given to develop a method to consider whether the desirable velocity for flushing can be obtained before flushing is performed. During flushing, the major and minor headloss is occurred when flushing water flows through a hydrant or drain valve. These headloss may slow down the velocity of flushing water so that it can reduce the flushing effect. Thus, in this study, we suggest a method to simulate the flow velocity of flushing water using "MinorLoss Coefficient" and "Emitter Coefficient" in EPANET. The suggested method is applied to a sample network and the water supply network of "A" city in Korea to compare the flushing effect between "flushing through a hydrant" and "flushing through a drain valve". In case of "flushing through a hydrant", if the hydraulic condition ocurring from a watermain pipe connecting to the inlet pipe of a hydrant to the outlet of a hydrant is not considered, the actual flowrate and velocity of a flow is less than the simulated flowrate and velocity of a flow. In case of "flushing through a drain valve", the flushing velocity and flowrate can be easily simulated and the difference between the simulated and the actual velocity and flowrate is not significant. Also, "flushing through a drain valve" is very effective to flushing a long-length pipe section because of its efficiency to obtain the flushing velocity. However, the number and location of a drain valve is limited compared to a hydrant so that "flushing through a drain valve" has a limited application in the field. For this reason, the engineer should consider various field conditions to come up with a proper flushing plan.

토양의 종류에 따른 초음파토양세척의 투수특성 분석

  • 정하익;송봉준;이용수;유준;강동우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.258-261
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique onto simple soil flushing was studied for the enhancement of water and liquid flows and the removal of contaminants in contaminated soils. The ultrasonic technique has been used to increase liquid flow and remove pollutants in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory permeability experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests.

  • PDF

A study on the removal of particulate matters using unidirectional flushing (단방향 플러싱에 의한 입자성 물질의 제거에 관한 연구)

  • Kim, Dooil;Cheon, Subin;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.371-380
    • /
    • 2015
  • Particulate matters in a water distribution system are main causes of turbidity and discoloration of tap water. They could be removed by conventional or uni-directional flushing in a water distribution system. The behaviors and required flow velocity of particles are not well known for their flushing. A model water main and hydrant were made from transparent acrylic pipe of 30mm and 16mm in diameter, respectively. We analyzed the effect of flushing velocity, particle density, and particle diameter. We found that the existence of break-though velocities at which particles begin to be removed, and which are affected by their physical properties. The removal efficiencies seemed to be influenced by resuspension capabilities related to their upward movement from the bottom. Heavy particles like scale were hard to remove through upflow hydrant because the falling velocity, calculated using Stokes' law, was higher. Particle removal efficiencies of upward hydrant and downward drain showed minor differences. Additionally, the length between hydrant and control valve affected flushing efficiency because the particulate matters were trapped in this space by inertia and recirculating flow.

Improvements of Electro Discharge Machining Process using Side flushing Devices (방전가공시 측면 플래싱 장치를 활용한 가공성 향상)

  • Shin, Seung-Hwan;Park, Keun;Maeng, Hee-Young
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.334-343
    • /
    • 2003
  • The discharge gap clearly is to order and to promote the improvement of processing feature of die-sinking electro discharge machining(EDM). If creation carbon, which generated by Pyrolysis of EDM oil and processing pace power which is generated in between an electrode and a workpiece, are overproduced, they will lower the processing speed and roughness of the surface. Therefore, it is gone through an experiment and the flow analysis of EDM oil in order to improve the treatment of processing chips, which is an important problem by contriving a new flushing method. The condition of an electric discharge is not considered to be a progressing of processing. It is assumed that the flow of processing fluid is equal to the flow of processing chip, which is remaining in the discharge gap, and thus, analyzing then comparing with the data of the experiment and investigate its correlation.

  • PDF

A Quasi-Steady Model for Sedimentation and Flushing of Reservoirs (저수지 퇴배사 모의를 위한 준정류모형)

  • Choi, Sung-Uk;Choi, Seong-Wook
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.2
    • /
    • pp.217-227
    • /
    • 2012
  • This paper presents a quasi-steady model for numerical simulations of reservoir sedimentation and reservoir flushing. The quasi-steady model is based on the assumption that the flow is steady with time-dependent stream morphology change. This is reasonable because stream morphology changes over a long period, while the flow changes rapidly. The proposed model is first applied to two laboratory experiments for reservoir sedimentation. The channel is shown to be adjusted to new sediment supply at the upstream by changing both the flow depth and slope. Simulated water surface and bed profiles compare favorably to measured data. The model is also applied to reservoir flushing. Good agreement between simulated and measured data is not obtained due to time variation of outflow generated to facilitate the flushing in the experiment. Finally, relationships for equilibrium flow depth and bed slope are proposed and tested through numerical experiments.

The Characteristics of Soil Remediation by Soil Flushing System Using PVDs (연직배수재를 이용한 토양세정시스템의 오염토양정화 특성)

  • Park, Jeong-Jun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.5
    • /
    • pp.76-86
    • /
    • 2007
  • For the purpose of ground improvement by means of soil flushing systems. Incorporated technique with prefabricated vertical drains have been used for dewatering from fine-grained soils. The laboratory model tests were performed by using the flushing tracer solutions for silty soils and recorded the tracer concentration changes with the elapsed time and flow rates. A mathematical model for prediction of contaminant transport using the PVD technology has been developed. The clean-up times for the predictions on both soil condition indicate more of a sensitivity to the dispersivity parameter than to the extracted flow rate and vertical velocity parameters. Based on the results of the analyses, numerical analysis indicate that the most important factor to the in-situ soil remediation in prefabricated vertical drain system is the effective diameter of contaminated soil.

Improvements of Electro Discharge Machining characteristics using Side Flushing Devices (측면 플래싱 장치를 이용한 형조 방전특성의 향상)

  • Maeng Heeyoung;Park Keun;Kim Sungdong
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.272-277
    • /
    • 2005
  • The discharge gap clearly is to order and to promote the improvement of processing feature of die-sinking electro discharge machining(EDM). If creation carbon, which generated by pyrolysis of EDM oil and processing pace power which is generated in between an electrode and a workpiece, are overproduced, they will lower the processing speed and roughness of the surface. Therefore, it is gone through the .flow analysis of EDM oil in order to improve the treatment of processing chips, which is an important problem by contriving a new flushing method. The condition of an electric discharge is not considered to be a progressing of processing. It is assumed that the flow of processing fluid is equal to the flow of processing chip, which is remaining in the discharge gap, and analyzing its correlation.

  • PDF

The assessment of self cleaning velocity and optimal flushing velocity in water distribution system (상수관망의 자가세척 유속과 적정 플러싱 유속 평가)

  • Bae, Cheol-Ho;Choi, Doo Yong;Kim, Ju-Hwan;Kim, Do-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.441-451
    • /
    • 2014
  • The flushing is important to maintain good water quality in water main. It is a technique of using water velocity to remove sediments in water distribution system. The variety of water quality problems can occur in a distribution system, so too can a variety of benefits be gained by system flushing. In order to effectively perform the flushing, the contaminants to be removed to set up and it can be solved, it is necessary to ensure the proper flow rate. In this study, the removal of contaminants present in the inner water pipe attached loose deposits such as fine particles of granular activated carbon, sand and iron corrosion product sought to derive flow rates. Thus, the constant observation of using pilot plant scale water distribution plant for the movement of floating characteristics of particles were assessed.