• Title/Summary/Keyword: Flushing 방법

Search Result 70, Processing Time 0.03 seconds

Study of Surfactant Enhanced Remediation Methods for Organic Pollutant(NAPL) Distributed over the Heterogeneous Medium (계면활성제를 이용한 불균질 매질에서 유기오염물(NAPL)의 정화효율에 관한 실험)

  • 서형기;이민희;정상용
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.51-59
    • /
    • 2001
  • Column and box tests were performed to investigate the removal efficiency of NAPL using the surfactant enhanced flushing In heterogeneous medium. Homogeneous Ottawa sand and heterogeneous soil were used to verify the increase of remediation efficiency for the surfactant enhanced flushing in column test. Box tests with two different heterogeneous sub-structure were performed to quantify the capability of the surfactant enhanced flushing as a remediation method to remove NAPL from the heterogeneous medium. Two different grain size sand layers were repeated in the box to simulate the heterogeneous layer formation and the modified fault structure was built to simulate the fault system in the box. O-xylene as a LNAPL and PCE as a DNAPL were used and oleamide as a non-ionic surfactant. The maximum NAPL effluent concentration with 1% oleamide flushing in the homogeneous column test increased about 460 times compared to that with only water flushing and about 250 times increased in the real soil column test. In heterogeneous medium, the maximum effluent concentration increased about 150 times in 1% oleamide flushing and most of NAPL were removed from the box within 8 pore volume flushing, suggesting that the removal efficiency increased very much compared to in only water flushing. Results investigated the capability of the surfactant enhanced remediation method to remove NAPL even in heterogeneous medium.

  • PDF

Effect of Periodic $N_2$-back-flushing in Paper wastewater Treatment using Carbon Ceramic Ultrafiltration and Microfiltration Membranes (탄소계 세라믹 한외 및 정밀 여과막으로 제지폐수 처리시 주기적 질소 역세척의 효과)

  • 황현정;박진용
    • Membrane Journal
    • /
    • v.12 no.1
    • /
    • pp.8-20
    • /
    • 2002
  • In this study using $N_2$-back flushing, which wwas not the general back-flushing method of membranes, the discharged wastewater from a paper plant was filtrated by 4 kinds of tubular carbon ceramic ultrafiltration membranes. We could in vestigate effects of $N_2$-back flushing period, transmembrane pressure (TMP)and flow rate and find optimal operating conditions. The $N_2$-back flushing time (BT) was fixed at 40 sec, filtration times (FT) were changed in 4~32 min, TNP in $1.0~3.0kg_f/cm^2$ the flow celocities in 0.53~1.09cm/s. The optimal conditions were discussed in the viewpoints of dimensionless permeate flux ($J/J_0$), toal permeate volume ($V_T$) and resistance of membrane fouling ($R_f$). Optimal back-flushing period was BT/FT=0.167 (FT=8 min ), in which more $V_T$ was obtained than that in BT/FT=0.083 (FT=4 min) which was the most friquent back-flushing condition. Then rising TMP should increase the driving force, and more $V_T$ could be accumulated. And rising flow rate should decrease membrane fouling increase permeate flux, and more $V_T$could be produced. Average rejection rates of pollutants were higher than 95% for turbidity and 45~83% for $COD_{Cr}$, but rejection rates of total dissolved solid (TDS) were lower than 10%.

Development of Electrokinetic-Flushing Equipment for a Remediation of Soil Contaminated with Radionuclides (방사성오염토양 제염을 위한 동전기세정장치 개발)

  • Kim, Gye-Nam;Jung, Yun-Ho;Lee, Jung-Joon;Moon, Jei-Kwon;Jung, Chong-Hun;Chung, Un-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • This study examined the effect of an electrokinetic-flushing remediation for a soil of a high permeability. The soil was sampled from the site around a research atomic reactor which had high hydro-conductivities due to a high content of sand in the soil. The flow rate of the washing reagent was fast at the beginning but it was reduced as time lapsed. In the case of using citric acid as a washing reagent, the flow rate was fastest, 78.7 ml/day. The removal efficiencies of $Co^{2+}$ and $Cs^+$ from a soil cell with acetic acid were the highest, which were 95.2% and 84.2% respectively. The soil waste-solution volume generated from the electrokinetic remediation was reduced to about 1/20 of that from the soil washing remediation. Meanwhile, the electrokinetic-flushing method enhanced the removal efficiencies of $Co^{2+}$ and $Cs^+$ from the soil by about 6% and 2% respectively, compared to those by the electrokinetic method. Consequently, it was found that the electrokinetic-flushing method was more effective for the remediation of a soil with a high permeability.

  • PDF

Improvement of sampling method for bacteriological test in tap water (수도꼭지에서 미생물 검사 목적의 샘플링 방법 개선 연구)

  • Lee, Eun-Sook;Lee, Dong-Sik;Lee, Mok-Young;Lee, Man-Ho;Han, Sun-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.519-525
    • /
    • 2011
  • We studied on the effect of faucet cleanliness, faucet conditions (screen, mixing faucet), and flushing time for bacterial detection in tap water. As results, tap water should be left to run to waste for 2 to 3 minutes and if a questionable cleanliness is questionable, disinfect the faucet by using flaming or other methods before sampling. We proposed sampling method to decrease effect of factors associated with bacterial detection in tap water and contributed to be evaluated more accurate water quality.

Effects of Flushing in Dental Unit Waterlines on the Bacterial Contamination Level (치과용 유니트 수관 물 빼기(Flushing)가 세균 오염도 감소에 미치는 영향)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.659-665
    • /
    • 2015
  • A wide variety of methods have been used to control Dental Unit Waterline (DUWL) contamination. Among the methods, flushing is mainly used because it is simple and easy to use. Generally, flushing of DUWL for 20 or 30 sec before using high speed handpieces or scalers is recommended. However, the appropriateness of flushing time was not investigated thoroughly. The purpose of this study was to check the effective time of flushing for decreasing bacterial contamination. Seven dental unit chairs were randomly selected in student clinical simulation laboratory for this experiment. DUWLs were continuously flushed and water samples were collected at an interval of 30 seconds for 15 minutes. From five dental unit chairs, water samples were collected every 10 seconds for 1 minute. Bacterial levels in water samples were examined by the culture method on R2A plates. After 10 second flushing of DUWLs, the number of bacteria significantly reduced and decreased continuously up to 40 seconds. However, even after the water was flushed for 15 minutes, the bacterial contamination level was not reduced below recommended bacteria level, 200 CFU/ml. In addition to flushing, the periodic chemical disinfection is required to control the DUWL water to the recommended level.

Understanding on TDS Creep Phenomena of Reverse Osmosis Membranes in Water Purifiers (역삼투막 정수기에서 발생하는 총용존고형물 크리프 현상의 이해)

  • Kang, Sanghyeon;Yun, Sunghan
    • Membrane Journal
    • /
    • v.32 no.2
    • /
    • pp.126-132
    • /
    • 2022
  • Water purifiers have a quite different characteristic in comparison with general membrane water treatment processes in which the running and resting are repeated dozens of times a day. In the case of water purifiers using reverse osmosis membranes, this characteristic makes a phenomenon that the total dissolved solids (TDS) of permeate in water purifiers at the beginning of running shows a higher value than a normal value (TDS reduction is lower than a normal value). It is called "TDS creep". The effects of resting times and feed concentrations on the TDS creep were investigated. The feed flushing, the volume increase in permeate side and the flushing with purified water were applied to reduce TDS creep and the effectiveness were observed. Among these trials, the minimization of concentration between feed and permeate side of reverse osmosis membrane like the flushing with purified water can be an ultimate solution to reduce the TDS creep.

분균일한 저널에서의 오일 휩

  • 이병준
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.273-277
    • /
    • 1994
  • 1990년 7월 이후 #2 베어링에서 발생한 오일 휩 현상을 감지하고서도 그 주원인을 일반적으로 흔히 발생하는 사항에서만 해결방안을 찾으려 노력한 결과 3년 반의 시간이 경과되었고, 뜻하지 않게도 저널 직경의 불균일에 의한 오일 휩 현상임 을 뒤늦게 알게 되었다. 철저한 점검의 필요성을 강조하지 않을 수 없다. 증기터빈 의 Overhaul 작업완료 후 Oil Flusning 절차가 있는데 이 Oil Flusning 방법에 문제 가 있다. 보통은 작업완료후 로터를 정지한 상태에서 베어링 앞에 Oil Strainer(Fine Mesh)를 설치하고 오일 펌프를 기동하여 Flushing을 하는데 이때 Strainer를 통과한 작은 이물질이 베어링내에 축적되었다가 터빈 기동시 이 이물질과 로터가 접촉되어 저널이 손상되게 된다. 인천화력3호기 #2 베어링의 오일 휩을 일으키게 한 저널의 편마모 현상도 이와같은 경우임에 틀림없다. 왜냐하면 '90, O/H시 #2 베어링 저널의 직경은 원통형이었기 때문이다. 따라서 Oil Flusning은 터빈 구조상 불가능한 경우 도 있겠지만 베어링 by-pass Oil Flushing 시스템으로 개조 운영되어야 저널 및 베어링 마멸현상을 제거할 수 있고 이로인한 오일 휩 현상도 예방할 수 있을 것으로 판단된다.

  • PDF

계면활성제를 이용한 토양내 유기오염물 (NAPL) 정화 방법의 연구

  • 이민희
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.96-98
    • /
    • 2000
  • Column experiments were peformed to evaluate the efficiency of surfactant flushing for remediation of non-aqueous phase liquid (NAPL) in the soil under controlled conditions. In column experiment less than 0.1 % of the original mass of tetrachloroethylene (PCE), remained in the column after 15 pore volumes of 1% sorbitan monooleate solution were passed through columns. To determine the influence of soil parameters that may affect the remediation process, column tests were repeated with different values of grain size, application rate, surfactant type, surfactant concentration, and solution viscosity (polymer mixed with surfactant). Experimental works suggest that surfactant flushing has a great potential to rapidly remove mass from NAPL in the soil.

  • PDF

Membrane Diffusion through Flexible-Wall Permeameter for Soil Flushing Tests (연성벽체 투수기를 이용한 흙세척 실험시 벽막을 통한 확산량 산정)

  • Junboum Park;Jee-Sang Kim
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.2
    • /
    • pp.95-103
    • /
    • 1997
  • Solvent extraction using aqueous solutions is presumed as one of the most effective methods applicable to in situ conditions without excavation of contaminated soils. Laboratory permeameter soil flushing test is performed to describe the process of solvent extraction of contaminants absorbed on soil particles. When the permeameter tests conducted, diffusion of contaminants through the permeameter flexible-wall was considered for adjusting the remediation percentage. Input and output balance for concentration was well matched in the permeameter tests. Nitrobenzene diffused so excessively (approximately 75%) that it was not suitable for the permeameter desorption tests. No biodegradation was detected in the soil samples.

  • PDF

Characteristics of Flow and Turbulence near the Movable Weir Gate (가동보 주변에서의 흐름 및 난류 특성에 관한 연구)

  • Seo, Il-Won;Park, Sung-Won;Kim, Tae-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.143-143
    • /
    • 2012
  • 최근 우리나라 주요하천에 걸쳐 수행된 '4대강 살리기 사업'에서는 하천에서 발생하는 홍수 및 가뭄재해의 방지를 위한 다양한 사업이 추진되었다. 특히 안정적인 용수공급과 재해방지를 위한 수위확보를 목적으로 4대강 16 개 구간에 걸쳐서 일반적 형태의 고정보와 함께 다양한 형상과 운영방식이 적용된 가동보로 이루어진 다목적보가 설치되었다. 본 연구에서는 4대강 유역(한강, 낙동강, 영산강, 금강)에 설치된 16 개 가동보의 형식 중 4곳(강정고령보, 강천보, 합천창녕보, 창녕함안보)에 적용된 라이징 섹터 게이트(rising sector gate)의 수리학적 특성을 분석하고자 가동보의 수리실험 모형을 개수로에 설치하여 보 주변에서의 흐름 및 난류 특성을 분석하고자 하였다. 4대강 유역에 설치된 라이징 섹터 게이트의 설치목적은 일반적인 고정보의 문제점으로 대두되고 있는 보 상류부의 퇴적토를 신속하게 배사(sediment flushing)하는 데 있다. 이를 위해서는 우선 배사 시에 보 하단부에서 최대유속을 발생시키면서 동시에 최적의 상하류 수위조건을 만족시키는 것이 매우 중요하다. 본 연구에서는 개수로에 설치된 가동보의 수문개방도에 따른 유속분포를 측정하였다. 보 주변에서의 보다 정밀한 유속장의 측정을 위해서 비접촉식 유속측정 방법인 PIV 측정방법을 이용하였다. PIV 측정방법은 일정한 입경과 밀도를 가지며 레이저 반사율이 높은 입자를 흐름에 투입하고 laser 발생장치로 laser sheet를 생성하여 레이저가 반사되어 나타나는 입자 각각의 시간변화에 따른 변위를 CCD 카메라로 가시화한 뒤 유속벡터값을 추출할 수 있게 한다. PIV 측정방법으로 유체의 흐름을 파악하고 시간평균된 유속결과를 바탕으로 난류 특성을 분석하였다. 수로전체 구간에 대하여 3차원 수치해석 프로그램인 FLOW-3D 모의결과와 비교하여 분석하였다. 실험을 통한 유속결과와 수치해석결과는 실험을 통한 유속결과와 비교 분석하였으며, 적용성을 검증한 후 다양한 조건에 대한 설계방안 및 유지관리에 활용하고자 한다.

  • PDF