• 제목/요약/키워드: Flush Inlet

검색결과 11건 처리시간 0.022초

Flush 흡입관 설계를 위한 매개변수 연구 (A Parametric Study for the Design of Flush inlet)

  • 이진규;정석영;안창수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.132-138
    • /
    • 2004
  • Flush inlet, which has been chosen for modem air vehicles to take advantage of structure compactness and small RCS, gives rise to some aerodynamic problems such as flow separation and distortion due to vortices which deteriorate the performance of both inlet and engine. In this study, pressure recoveries at inlet exit plane were evaluated through numerical analyses of 3D turbulent flow for various inlet shapes and flight conditions. Inlet shape was controlled by changing ramp angle and width of throat, and effects of mass flow rate and angle of attack were investigated.

  • PDF

Effect of Inlet Direction on the Refrigerant Distribution in an Aluminum Flat-Tube Heat Exchanger

  • Kim, Nae-Hyun;Kim, Do-Young;Byun, Ho-Won;Choi, Yong-Min
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권4호
    • /
    • pp.130-136
    • /
    • 2008
  • The refrigerant R-134a flow distributions are experimentally studied for a round header/ten flat tube test section simulating a brazed aluminum heat exchanger. Three different inlet orientations(parallel, normal, vertical) were investigated. Tests were conducted with downward flow for the mass flux from 70 to 130 $kg/m^2s$ and quality from 0.2 to 0.6. In the test section, tubes were flush-mounted with no protrusion into the header. It is shown that normal and vertical inlet yielded approximately similar flow distribution. At high mass fluxes or high qualities, however, slightly better results were obtained for normal inlet configuration. The flow distribution was worst for the parallel inlet configuration. Possible explanation is provided based on flow visualization results.

이차원 물분사 추진장치 입구면 형상에 관한 연구 (A Study on the Configuration of Two-Dimensional Waterjet Inlet)

  • 류재문;홍삼권;김영기
    • 대한조선학회논문집
    • /
    • 제36권2호
    • /
    • pp.9-21
    • /
    • 1999
  • 물분사 추진장치(waterjet)는 현재 고속선의 추진기로 폭넓게 사용되고 있으나, 입구면(inlet) 형상에 따른 효율 문제와 제작상의 어려움으로 인해 제작사는 한정되어 있다. 입구면 형상 설계에 있어서 가장 중요한 문제는 효율에 크게 영향을 주는 공동(cavitation) 발생을 최소화하는 것이다. 본 논문에서는 포텐셜 유동해석에 의해 공동발생이 최소화되는 최적 형상을 찾기 위해, 평접형(flush type) 이차원 물분사 추진장치의 입추면 형상을 수치계산 모델로 택하여 이차원 단면으로 가정하고, 유동해석을 수행하였다. 형상 파라미터의 변화를 통해 얻어진 다양한 입구면 형상에 대해 수치계산을 수행하여, 공동 발생에 미치는 입구면 형상의 영향을 조사하였고, 이를 바탕으로 최적 형상을 얻을 수 있는 형상해석 기법을 확립하였다. 또한 주어진 입구면 주위의 압력분포를 입력자료로 하여 입구면 형상이 찾아지도록 하는 형상 설계법을 확립하였다. 입구면의 형상 해석 및 형상 설계시 이용한 포텐셜 유동해석은 최근 공동문제 해석에 적용되어 좋은 결과를 주고 있는 포텐셜을 기저로 한 패널법[1,2]을 적용하였다. 형상 해석을 수행하여 얻어진 결과와 Kashiwadani[3,4]의 결과를 비교하여 근사한 결과를 얻은 것으로 본 논문의 형상 해석 기법의 우수성을 알 수 있었다. 형상 해석 결과로 얻어진 압력분포를 입력자료로 하여 입구면의 lip과 ramp에 대한 형상 설계를 수행한 결과 모두 만족스러운 결과를 얻었다.

  • PDF

알루미늄 평행류 열교환기 헤더 내 냉매 분배에 관한 연구 (A Study on the Refrigerant Distribution in an Aluminum Parallel Flow Heat Exchanger Header)

  • 김도영;김내현;김수환;변호원;이을종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1123-1128
    • /
    • 2009
  • The refrigerant R-134a flow distributions are experimentally studied for a round header/ten flat tube test section simulating a brazed aluminum heat exchanger. Three different inlet orientations (parallel, normal, vertical) were investigated. Tests were conducted with downward flow for the mass flux from 70 to $130\;kg/m^2s$ and quality from 0.2 to 0.6. In the test section, tubes were flush-mounted with no protrusion into the header. It is shown that normal and vertical inlet yielded approximately similar flow distribution. At high mass fluxes or high qualities, however, slightly better results were obtained for normal inlet configuration. The flow distribution was worst for the parallel inlet configuration. Possible explanation is provided based on flow visualization results.

  • PDF

도시 지역특성을 고려한 빗물받이 유입구의 막힘계수 산정 (An Estimation of Clogging Factors at Stormwater Grate Inlets with Consideration of Urban Area Characteristics)

  • 김정수;송주일;윤세의
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.595-598
    • /
    • 2007
  • Urban storm water collection and conveyance systems are critical components of the urban infrastructures. During a storm event, street grate inlets are usually loaded with debris by the first-flush runoff volume. Grate inlets are subject to clogging effects. Effective interception area of grate inlets was decreased by clogging. It also decreased the interception capacity of grate inlets and increased the inundation area in street. Therefore, it is necessary to analyze the clogging characteristics and interception capacity change by clogging for appropriate design and management of grate inlets. In this study, field survey was executed to investigate debris and clogging pattern of grate inlet in 9 areas. The clogging factor with consideration of urban area characteristics was estimated with the field survey results.

  • PDF

침투형 빗물받이의 배수 및 비점오염물질 저감 효과 (Reduction Effect of Nonpoint Source Pollutants and Drainage of Infiltration Grate Inlet)

  • 이원용;임봉수;박인성
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.474-480
    • /
    • 2017
  • This study was to estimate the reduction effect of nonpoint source pollutants according to the rainfall intensity and drainage of infiltration grate inlet. Soil infiltration flow was measured on-site and SS load by the filter part was calculated by the experimental data in laboratory reactor test. Soil infiltration flow was measured to be about $1m^3/hr$ in soil condition saturated with water. The filter part of the infiltration grate inlet was a hydraulic equipment unhindered by soil infiltration on the bottom of the storage tank, because the infiltration flow was measured to be about $3m^3/hr$ continuously in the closing infiltration hole condition. Infiltration flow and SS load were over about $1m^3/hr$ and 1.71 kg according to laboratory results by the filter part using the artifical sample. Therefore, the above values could be presented as the limitted value to start the reduction of filtration effect. Reduction efficiencies of SS load by the filter part for the rainfall intensity were about 87 % at 5 mm/hr and about 61 % at 10 mm/hr in consideration of one infiltration grate inlet got the drainage area about $200m^2$. The reduction efficiency of nonpoint source pollutants was very effective in the first flush rainfall. However, the reduction efficiency by rainfall density was higher than by flow.

합류식 하수관거 월류수 처리를 위한 와류형 분리장치의 최적 운전조건 (Optimal Operating Condition of Vortex Separator for Combined Sewer Overflows Treatment)

  • 한정균;주재영;이범준;나지훈;박철휘
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.557-564
    • /
    • 2009
  • A combined sewer system can quickly drain both storm water and sewage, improve the living environment and resolve flood measures. A combined sewer system is much superior to separate sewer system in reduction of the non-point source pollutant load. However, during rainfall. it is impossible in time, space and economic terms to cope with the entire volume of storm water. A sewage system that exceeds the capacity of the sewer facilities drain into the river mixed with storm-water. In addition, high concentration of CSOs by first-flush increase pollution load and reduce treatment efficiency in sewage treatment plant. The aim of this study was to develope a processing unit for the removal of high CSOs concentrations in relation to water quality during rainfall events in a combined sewer. The most suitable operational design for processing facilities under various conditions was also determined. With a designed discharge of 19.89 m/min, the removal efficiency was good, without excessive overflow, but it was less effective in relation to underflow, and decreased with decreasing particle size and specific gravity. It was necessary to lessen radius of vortex separator for increasing inlet velocity in optimum range for efficient performance, and removal efficiency was considered to high because of rotation increases through enlargement of comparing height of vortex separator in diameter. By distribution of influent particle size, the actual turbulent flow and experimental results was a little different from the theoretical removal efficiency due to turbulent effect in device.

알루미늄 평판관 증발기 헤더 내 공기-물 2상류 분지 실험 (Distribution of Air-Water Two-Phase Flow in a Header of Aluminum Flat Tube Evaporator)

  • 김내현;신태룡;심용섭
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.55-65
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a round header - flat tube geometry simulating a parallel flow heat exchanger. The number of branch flat tube is thirty. The effects of tube outlet direction, tube protrusion depth as well as mass flux, and quality are investigated. The flow at the header inlet is identified as annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted configuration, most of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, however, most of the water flows through rear part of the header. The protrusion depth, mass flux, or quality does not significantly alter the flow pattern. Possible explanations are provided based on the flow visualization results. Negligible difference on the water flow distribution was observed between the parallel and the reverse flow configuration.

Container System Actively Maintaining High CO2 Concentration for Improved Sensory Quality of Kimchi

  • Lee, Hye Lim;An, Duck Soon;Jung, Yong Bae;Lee, Dong Sun
    • 한국포장학회지
    • /
    • 제22권3호
    • /
    • pp.79-84
    • /
    • 2016
  • A kimchi container actively controlling $CO_2$ concentration by timely flushing of $CO_2$ gas was structured and tested in its capability and effectiveness because high $CO_2$ concentration enhances the sensory flavor of the product. The inlet and outlet valves of $CO_2$ gas were programmed to open and close allowing synchronous vent/$CO_2$ flush according to the requirements of its dissolution in the contained kimchi. During the chilled storage, the headspace of container could be maintained at desired high $CO_2$ concentration providing the preferred kimchi in sensory quality compared to control of the conventional container. However, there was no significant difference between the high $CO_2$ container and control (container simply closed with air) in kimchi quality attributes of pH, titratable acidity, total viable bacterial count, Lactobacillus sp. count and Leuconostoc sp. count. The flow rate and time interval of $CO_2$ flushing need to be adjusted considering the kimchi amount, headspace volume and ripening time. The designed system has potential to be applied in refrigerator appliances in homes and food service industry.

파라핀 슬러리를 사용한 다칩모듈의 냉각특성 (Cooling characteristics of the multichip module using paraffin slurry)

  • 조금남;최민구
    • 대한기계학회논문집B
    • /
    • 제22권6호
    • /
    • pp.888-898
    • /
    • 1998
  • The present study investigated the effects of the experimental parameters on the cooling characteristics of the multichip module cooled by the indirect liquid cooling method using water and paraffin slurry. The experimental parameters are mass fraction of 2.5 ~ 7.5% for paraffin slurry, heat flux of 10 ~ 40 W/cm$^{2}$ for the simulated VLSI chips and Reynolds numbers of 5,300 ~ 15,900. The apparatus consisted of test section, paraffin slurry maker, pump, constant temperature baths, flowmeter, etc. The test section made of in-line, four-row array of 12 heat sources for simulating 4 * 3 multichip module which was flush mounted on the top wall of a horizontal rectangular channel with the aspect ratio of 0.2. The inlet temperature was 20 deg. C for all experiments. The size of paraffin slurry was constant as 10 ~ 40 .mu.m befor and after the experiment. The chip surface temperatures for paraffin slurry with the mass fraction of 7.5% showed lower by 16 deg. C than those for water when the heat flux is 40 W/cm$^{2}$. The local heat transfer coefficients for the paraffin slurry with the mass fraction of 7.5% were larger by 17 ~ 25% than those for water at the first and the fourth row. The local heat transfer coefficients reached to a row-number-independent, thermally fully developed value approximately after the third row. The local Nusselt numbers at the fourth row for paraffin slurry with the mass fraction of 7.5% were larger by 23 ~ 29% than those for water.