• 제목/요약/키워드: Fluorine recovery

검색결과 9건 처리시간 0.027초

왕수분해와 결합한 자동분석법의 토양 중 불소시험 유효성 연구 (The Validation Study of Auto Anlysis Method Combined with Aqua Regia Digestion for Fluorine of Soil)

  • 나경호;윤인철;이정복
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권5호
    • /
    • pp.8-15
    • /
    • 2010
  • The purpose of this research is to check the validation of an auto-analysis method combined with aqua regia digestion apparatus for improvement of water distillation method used as a fluorine test of soil. Fluorine contents of CaO used in the pretreatment course of water distillation method were 120 mg/kg ~ 5,064 mg/kg at the blank test, which was exceeded up to maximum 12.5 times of the soil standard, so it was estimated due to a effect of fluorine existing as impurities of CaO. The recovery test of the same samples indicated that water distillation method and auto-analysis method were 134.5mg/kg and 161.7mg/kg respectively, the recovery ratio of the latter was 16.8% higher than the formal. The validation test of two methods satisfied the standard, but auto analysis method was excellent more than distillation method. Also, auto analysis method could save a analysis time up to maximum 4.7 times by comparison with water distillation method.

불화 온실 가스 저감 및 분리회수 기술의 연구개발 동향 (Separation and Recovery of F-gases)

  • 남승은;박아름이;박유인
    • 멤브레인
    • /
    • 제23권3호
    • /
    • pp.189-203
    • /
    • 2013
  • 과불화질소, 육불화황, 삼불화질소와 같은 불소를 포함한 불화가스는 이산화탄소 온실가스에 비교해 배출량은 적지만 지구온난화지수가 매우 높아 지구온난화에 미치는 영향이 크다. 이러한 불화가스의 주요배출원이 국가 중추산업인 반도체/LCD 산업이나 중전기 산업 등에 집중되어 있어 더욱 심각하다. 따라서 본 논문에서는 불화가스 저감 기술 중 분리막 기반 불화가스 회수 분리 공정을 중심으로 불화가스 저감 기술 개발 현황을 살펴보고자 하였다.

PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가 (Evaluation of PET Image for Fluorine-18 and Gallium-68 using Phantom in PET/CT)

  • 윤석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.321-327
    • /
    • 2018
  • The purpose of this study is to compare PET imaging performance with Fluorine-18 ($^{18}F$) and Gallium-68 ($^{68}Ga$) for influence of physical properties of PET tracer. Measurement were performed on a Siemens Biograph mCT64 PET/CT scanner using NEMA IEC body phantom and Flangeless Esser PET phantom containing filled with $^{18}F$ and $^{68}Ga$. Emission scan duration(ESD) was set to 1, 2, 3, 4 and 5min/bed for $^{68}Ga$ and 1min/bed for $^{18}F$. The PET image were evaluated in terms of contrast, spatial resolution. Under same condition, The percentage of contrast recovery measured in the phantom ranged from 16.88% to 72.56% for $^{68}Ga$ and from 27.51% to 74.43% for $^{18}F$ and The FWHM value to evaluate spatial resolution was 10.96 mm for $^{68}Ga$ and 9.19 mm for $^{18}F$. For this study, $^{18}F$ produces better image contrast and spatial resolution than $^{68}Ga$ due to higher positron yield and lower positron energy ($^{18}F$: 96.86%, 633.5 keV, $^{68}Ga$: 88.9%, 1899 keV), The physical properties of PET tracer effect on the PET image. $^{68}Ga$ image applying ESD of 3, 4, 5min/bed were showed similar to $^{18}F$ image with ESD of 1min/bed. This study suggests that increasing ESD for acquiring $^{68}Ga$ PET image seem to be similar to $^{18}F$ image.

친전자성 치환반응을 위한 $[^{18}F]F_2$ Gas의 생산 연구 (Production of $[^{18}F]F_2$ Gas for Electrophilic Substitution Reaction)

  • 문병석;김재홍;이교철;안광일;천기정;전권수
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권4호
    • /
    • pp.228-232
    • /
    • 2006
  • 목적 : $[^{18}F]F_2\;(T_{1/2}=110\;min)$ 기체를 이용하여 친전자성 치환반응으로 방사성동위원소 $^{18}F$을 표지하는 방법은 새로운 앙전자방출단층촬영용 방사성의약품 개발 분야에서 유용하게 이용되고 있다. 그림에도 불구하고 $[^{18}F]F_2$를 높은 생산수율과 비방사능으로 생산하기 위한 표적 개발 연구는 아직도 진행 중에 있다. 본 연구에서는 친핵성 치환반응으로 $^{18}F$을 도입하기 어려운 방사성의약품에 친전자성 치환반응으로 방사성동위원소를 도입할 수 있는 $[^{18}F]F_2$ 가스의 효율적인 생산에 관해 연구하였다. 대상 및 방법: 표적은 원추형 모양의 알루미늄 재질로 제작하였다. $[^{18}F]F_2$ 생산을 위한 핵반응으로 $^{18}O(p,n)^{18}F$를 사용하였으며, two-step 빔 조사방법을 이용하였다. 첫 번째 조사는 농축 $[^{18}O]O_2$가스를 표적에 충진한 후 빔 조사하여 $^{18}O(p,n)^{18}F$ 핵반응을 일으킴으로써 $^{18}F$를 생산한다. 생산된 $^{18}F$은 표적 챔버 기벽에 흡착된다. $[^{18}O]O_2$은 재사용을 위하여 냉각포획법으로 회수하였으며, $^{18}F$를 회수하기 위해 $[^{19}F]F_2/Ar$ 가스를 충진한 후, 두 번째 빔을 조사하여 방사성불소를 회수하는 방법으로 구성된다. 본 연구에서는 최적의 방사성불소 생산 조건을 찾기 위해 빔 조사 시간, 빔 전류 세기 농축 $[^{18}O]O_2$ 충진 압력 등의 변화에 따라 생산량을 평가하였다. 결과: 빔 조사 시간, 빔 전류, 농축 $[^{18}O]O_2$ 충진 압력 등의 조건을 변화시키면서 생산량을 평가한 결과 최적의 빔 조사 조건은 다음과 같다. 첫 번째 조사: 농축 $[^{18}O]O_2$을 약 15.0 bar충진, 13.2 MeV, 30 ${\mu}A$로 60-90분 조사; 두 번째 조사: 1% $[^{19}F]F_2/Ar$혼합가스 12.0 bar 충진, 13.2 MeV, 30 ${\mu}A$로 20-30분 조사 후 아르곤 가스로 회수하였을 때 EOB(end of bombardment) 기준으로 약 $34{\pm}6.0$ GBq(n>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.

비료공장의 인산 슬러리로부터 규불산 제조 (Production of Fluorosilicic Acid from Phosphoric Acid Slurry of a Fertilizer Manufacturing Plant)

  • 김세원;문우균;박흥석
    • 한국산학기술학회논문지
    • /
    • 제13권2호
    • /
    • pp.926-933
    • /
    • 2012
  • 일반적으로 비료용 인산은 황산과 인광석의 분해반응에 의해 생산되는데 이 반응은 발열반응으로써 온도가 상승하게 되면 생산수율 저하의 문제점이 따른다. 이를 해결하기 위해 인산제조공정에서는 불산(HF)과 사불화규소(SiF4)가 함유된 증기(vapor, $80^{\circ}C$)를 배출시키는 진공냉각기(vacuum cooler)를 운영하고 있으나, 이 과정에서 냉매 및 폴리실리콘 원료로 활용가능한 귀중한 자원(불소 & 규소)들이 버려지고 있다. 본 연구는 인산제조공정 부산물인 규불산(H2SiF6)으로 회수하기 위한 기초 실험연구로서, 불소회수 후 인산슬러리 내 불소 농도변화를 분석하여 규불산 회수가능량을 예측하였다. 회수 후 불소농도는 약 0.12wt% 감소하였고, 대상 비료공장의 생산규모를 고려할 경우 불소 회수가능량은 약 5,509 톤/년이었다. 한편 현장에서, 규불산의 농도는 0.35wt%에서 7.33wt%까지 농축되었고, 진공냉각기로부터 배출되는 증기유량은 $51,000m^3/hr$이었다. 또한 Pilot실험을 통한 불소 회수효율은 76.74%로 나타나, 실제 회수할 수 있는 규불산량은 5,340 톤/년으로 추정되었다.

국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선 (Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer)

  • 박준형;임기섭;이홍진;정경일;이병철;이인원
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

우라늄 정광의 용해/정제 및 핵연료 분말 가공공정에서 발생된 폐액의 처리에 관한 연구 (A Study on Treatment of Wastes from the Uranium Ore Dissolution/purification and Nuclear Fuel Powder Fabrication)

  • 정경채;황성태
    • 공업화학
    • /
    • 제8권1호
    • /
    • pp.99-107
    • /
    • 1997
  • 핵연료분말 변환공정 중 우라늄 정광의 용해/정제 및 가공공정에서 발생하는 폐액의 처리에 대한 연구가 수행되었다. 우라늄 정광의 용해/정제공정에서 발생된 폐액은 pH 1 이하의 강산성으로 AUC 분말 제조공정에서 발생된 폐액 중의 우라늄을 ADU 형태로 회수한 후 발생된 2차 여액 속의 미세 ADU 입자 용해를 위해 사용된다. 2차 여액 속의 미세 ADU 입자들의 용해를 위해 용해/정제 공정의 폐액을 사용해서 pH 4로 전처리한 후, lime을 이용하여 pH 9.2로 30분 정도 반응시킬 경우 여액 중의 우라늄 농도를 3ppm 이하로 처리할 수 있었다. 가공 폐액은 미세 oil droplet들이 emulsion 형태로 발생하며, 약 300ppm의 우라늄 농도를 나타내었다. 먼저, emulsion을 파괴시키는 방법은 질산을 가하여 급속가열시키는 것이 효과적이었다. Emulsion 파괴 후 1mole NaOH를 가하여 $Na_2U_2O_7$형태로 우라늄을 회수하였으며, pH11.5에서 최적 처리조건을 나타내었으나 최종 여액 중의 우라늄 농도는 5ppm을 나타냈다. 여액 중의 우라늄 농도를 최소화하기 위해 lime으로 처리하는 방법이 연구되었으며, 가공폐액을 직접 lime 처리하기 위해 4N 질산으로 emulsion을 파괴 시킨 후, pH 1.6에서 lime을 1.5g/100ml로 반응시킬 경우 여액 중의 우라늄 농도를 1ppm까지 낮출 수 있었다. 한편, 경수로형 분말 제조공정 중 우라늄 회수공정에서 발생된 폐액 중의 미량 우라늄은 NaOH를 가하여 우라늄을 침전시킨 결과, $Na{\cdot}U{\cdot}F{\cdot}NH_4$등이 혼합된 침전물이 얻어졌으며, 여과후 상등액에서는 우라늄은 감지할 수 없었다.

  • PDF

68Ga 표지 PET/CT 검사의 최적화된 매개변수에 대한 연구 (Study of 68Ga Labelled PET/CT Scan Parameters Optimization)

  • 곽인석;이혁;김시활;문승철
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.111-127
    • /
    • 2023
  • Purpose: Gallium-68 (68Ga) is increasingly used in nuclear medicine imaging for various conditions such as lymphoma and neuroendocrine tumors by labeling tracers like Prostate Specific Membrane Antigen (PSMA) and DOTA-TOC. However, compared to Fluorine-18 (18F) used in conventional nuclear medicine imaging, 68Ga has lower spatial resolution and relatively higher Signal to Background Ratio (SBR). Therefore, this study aimed to investigate the optimized parameters and reconstruction methods for PET/CT imaging using the 68Ga radiotracer through model-based image evaluation. Materials and Methods: Based on clinical images of 68Ga-PSMA PET/CT, a NEMA/IEC 2008 PET phantom model was prepared with a Hot vs Background (H/B) ratio of 10:1. Images were acquired for 9 minutes in list mode using DMIDR (GE, Milwaukee WI, USA). Subsequently, reconstructions were performed for 1 to 8 minutes using OS-EM (Ordered Subset Expectation Maximization) + TOF (Time of Flight) + Sharp IR (VPFX-S), and BSREM (Block Sequential Regularized Expectation Maximization) + TOF + Sharp IR (QCFX-S-400), followed by comparative evaluation. Based on the previous experimental results, images were reconstructed for BSREM + TOF + Sharp IR / 2 minutes (QCFX-S-2min) with varying β-strength values from 100 to 700. The image quality was evaluated using AMIDE (freeware, Ver.1.0.1) and Advanced Workstation (GE, USA). Results: Images reconstructed with QCFX-S-400 showed relatively higher values for SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), count, RC (Recovery Coefficient), and SUV (Standardized Uptake Value) compared to VPFX-S. SNR, CNR, and SUV exhibited the highest values at 2 minutes/bed acquisition time. RC showed the highest values for a 10 mm sphere at 2 minutes/bed acquisition time. For small spheres of 10 mm and 13 mm, an inverse relationship between β-strength increase and count was observed. SNR and CNR peaked at β-strength 400 and then decreased, while SUV and RC exhibited a normal distribution based on sphere size for β-strength values of 400 and above. Conclusion: Based on the experiments, PET/CT imaging using the 68Ga radiotracer yielded the most favorable quantitative and qualitative results with a 2 minutes/bed acquisition time and BSREM reconstruction, particularly when applying β-strength 400. The application of BSREM can enhance accurate quantification and image quality in 68Ga PET/CT imaging, and an optimization process tailored to each institution's imaging objectives appears necessary.