• 제목/요약/키워드: Fluorescent lamps

검색결과 382건 처리시간 0.036초

Utilization Efficiencies of Electric Energy and Photosynthetically Active Radiation of Lettuce Grown under Red LED, Blue LED and Fluorescent Lamps with Different Photoperiods

  • Lee, Hye In;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • 제38권4호
    • /
    • pp.279-286
    • /
    • 2013
  • Purpose: This study was conducted to analyze the utilization efficiencies of electric energy and photosynthetically active radiation of lettuce grown under red LED, blue LED and fluorescent lamps with different photoperiods. Methods: Red LED with peak wavelength of 660 nm and blue LED with peak wavelength of 450 nm were used to analyze the effect of three levels of photoperiod (12/12 h, 16/8 h, 20/4 h) of LED illumination on light utilization efficiency of lettuce grown hydroponically in a closed plant production system (CPPS). Cool-white fluorescent lamps (FL) were used as the control. Photosynthetic photon flux, air temperature and relative humidity in CPPS were maintained at 230 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, $22/18^{\circ}C$ (light/darkness), and 70%, respectively. Electric conductivity and pH were controlled at 1.5-1.8 $dS{\cdot}m^{-1}$ and 5.5-6.0, respectively. The light utilization efficiency based on the chemical energy converted by photosynthesis, the accumulated electric energy consumed by artificial lighting sources, and the accumulated photosynthetically active radiation illuminated from artificial lighting sources were calculated. Results: As compared to the control, we found that the accumulated electric energy consumption decreased by 75.6% for red LED and by 70.7% for blue LED. The accumulated photosynthetically active radiation illuminated from red LED and blue LED decreased by 43.8% and 33.5%, respectively, compared with the control. The electric energy utilization efficiency (EEUE) of lettuce at growth stage 2 was 1.29-2.06% for red LED, 0.76-1.53% for blue LED, and 0.25-0.41% for FL. The photosynthetically active radiation utilization efficiency (PARUE) of lettuce was 6.25-9.95% for red LED, 3.75-7.49% for blue LED, and 2.77-4.62% for FL. EEUE and PARUE significantly increased with the increasing light period. Conclusions: From these results, illumination time of 16-20 h in a day was proposed to improve the light utilization efficiency of lettuce grown in a plant factory.

도시철도차량에 LED 광원의 적용에 관한 연구 (A Study on the Application of LED Light Source in Subway Train)

  • 최성국;박대원;길경석;박희철;조은제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.2050-2055
    • /
    • 2009
  • This paper describes the proceeding experimental results to replace the 32 [W] fluorescent lamp installed in subway train to a LED module. We fabricated 25 [W] LED modules to meet the illuminance 300 [lx] specified in the standard for subway train. After the installation of LED modules, comparative analysis with conventional fluorescent lamps was carried out. From the experimental results, illuminances on the height of 0.85 [m] and 1 [m] above floor were 323 [lx] and 360 [lx], respectively. These illuminances satisfied the requirement 300 [lx]. By the application of 25 [W] LED module as a light source in subway train, energy saving about 22 [%] compared with 32 [W] fluorescent is acquired. Also, low cost of maintenance is expected due to 8 times longer lifetime 50,000 hours of LED than that 6,000 hours of fluorescent lamp.

  • PDF

정전류와 부 열저항 특성을 갖는 AC Direct Driver를 이용한 LED 형광등 개발 (Design of a AC driver with constant current and negative temperature resistance for a LED lamp)

  • 김현조;손경민;김민;김관형;변기식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.382-384
    • /
    • 2013
  • LED는 일반 백열등에 비해 훨씬 밝으면서도 저전력이라는 장점을 지니고 있다. 이에 기존 형광등이 지니는 효율적, 환경적 문제점을 개선하기 위해 LED형광등의 개발과 상용화가 이루어 졌다. LED는 형광등과 달리 극성을 지니는 단방향성 소자로 교류전원을 직접 쓸 수 없기 때문에 전원공급장치를 필요로 한다. 이 전원공급장치는 부피가 크고 가격이 비싸기 때문에 유지비용면에서 일반 형광등에 비해 기능성이 떨어진다. 본 연구에서는 이 전원공급장치를 대신하여 간략하게 AC전원을 정류하고, 전압변동에 따른 전류변화로 인한 빛의 밝기가 변하는 현상을 없애기 위해 정전류로 제어할 수 있는 회로를 구성하고 이를 LED모듈과 구분하여 Plug in/out 방식의 교체형 모듈로 구성하여 유지보수에 있어 저렴하고 손쉬운 교체가 가능한 소자개발방법을 제안하고자 한다.

  • PDF

Effects of Light Quality and Intensity on the Carbon Dioxide Exchange Rate, Growth, and Morphogenesis of Grafted Pepper Transplants during Healing and Acclimatization

  • Jang, Yoonah;Mun, Boheum;Seo, Taecheol;Lee, Jungu;Oh, Sangseok;Chun, Changhoo
    • 원예과학기술지
    • /
    • 제31권1호
    • /
    • pp.14-23
    • /
    • 2013
  • This study evaluated the influence of light quality and intensity during healing and acclimatization on the $CO_2$ exchange rate, growth, and morphogenesis of grafted pepper (Capsicum annuum L.) transplants, using a system for the continuous measurement of the $CO_2$ exchange rate. C. annuum L. 'Nokkwang' and 'Tantan' were used as scions and rootstocks, respectively. Before grafting, the transplants were grown for four weeks in a growth chamber with artificial light, where the temperature was set at $25/18^{\circ}C$ (light/dark period) and the light period was 14 hours $d^{-1}$. The grafted pepper transplants were then healed and acclimatized under different light quality conditions using fluorescent lamps (control) and red, blue, and red + blue light-emitting diodes (LEDs). All the transplants were irradiated for 12 hours per day, for six days, at a photosynthetic photon flux (PPF) of 50, 100, or 180 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. The higher PPF levels increased the $CO_2$ exchange rate during the healing and acclimatization. A smaller increase in the $CO_2$ exchange rates was observed in the transplants under red LEDs. At a PPF of 180 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, the $CO_2$ exchange rate of the transplants irradiated with red LEDs was lowest and it was 37% lower than those irradiated with fluorescent lamps. The $CO_2$ exchange rates of transplants irradiated with blue LEDs was the highest and 20% higher than those irradiated under fluorescent lamps. The graft take was not affected by the light quality. The grafted pepper transplants irradiated with red LEDs had a lower SPAD value, leaf dry weight, and dry matter content. The transplants irradiated with blue LEDs had longer shoot length and heavier stem fresh weight than those irradiated with the other treatments. Leaves irradiated with the red LED had the smallest leaf area and showed leaf epinasty. In addition, the palisade and spongy cells of the pepper leaves were dysplastic and exhibited hyperplasia. Grafted pepper transplants treated with red + blue LEDs showed similar growth and morphology to those transplants irradiated with fluorescent lamps. These results suggest that high-quality grafted pepper transplants can be obtained by healing and acclimatization under a combination of blue and red lights at a high PPF level.

무전극 형광램프를 위한 유도코일의 전자계 해석 (Electromagnetic Analysis of Induction Coil for Electrodeless Fluorescent lamps)

  • 김광수;이종찬;박대희;박성목
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.187-190
    • /
    • 2002
  • The Electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. but Increasing awareness of electromagnetic compatibility(EMC) issues in lighting application, the problems of interference generation by electrodeless fluorescent lighting system have been highlighted. In this paper, Maxwell 2D finite element analysis program(Ansoft) is used to obtain electromagnetic properties associated with the coil and nearby structures. and also evaluated Flux B, H by changing the input current.

  • PDF

무전극 램프의 방전가스 연구 (A Study on discharge gas of Fluorescent Induction Lamp)

  • 김근;전병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1481_1482
    • /
    • 2009
  • Pure Xe, Kr and Ne atoms and Mixures of Xe-Ne used in fluorescent induction lamps(FILs). However standard regulation of FILs is not made up until now. Therefore, the electron transport coefficients, the electron drift velocity W, the longitudinal diffusion coefficient NDL and the ionization coefficient $\alpha$/N in pure Xe, Kr, Ne gases and Xe-Ne mixtures(1:9, 5:5, 7:3) were calculated over the wide E/N range from 0.01 to 500 Td at 1 Torr by two-term approximation of the Boltzman equation.

  • PDF

Electro-optic Characteristics of External Electrode Fluorescent Lamps Depending on the Glass Thickness

  • Yu, Mi-Yeon;Ko, Jae-Hyeon;Kim, Young-Youb;Kim, Kyung-Ran
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.703-706
    • /
    • 2009
  • The external electrode fluorescent lamp(EEFL) has recently been applied to backlight of LCD TV as a new light source. The dependence of the electro-optic characteristics of the EEFL used in direct-lit backlights on the glass thickness was examined in detail, and the ultraviolet(UV)-light efficiency was estimated. It was found that the lamp efficiency became larger as the glass thickness decreased if other conditions were the same.

  • PDF

형광램프의 점등방식에 대한 특성비교에 관한 연구 (A study on the characteristics by Ignition type of Fluorescent Lamps)

  • 황명근;임종민;신상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2156-2158
    • /
    • 2000
  • Proposals on optimized ignition type of fluorescent fixtures by comparing electrical and optical characteristics for magnetic ballast and electronic starter type, magnetic ballast and glow starter and electronic ballast.

  • PDF

무전극 형광등 시스템의 구동 주파수 및 방식에 따른 특성 분석 (Analysis of the Electrodeless Fluorescent Lamps' Radio Interference Characteristics by Operating Frequencies and Structures)

  • 목진담;전상봉;박승근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.45-48
    • /
    • 2011
  • 무전극 형광등은 수명이 매우 길고 에너지 효율이 높아 점차 활용이 늘고 있는 친환경적인 새로운 광원에 속하지만 자기유도 방전을 위해서는 최소한의 구동 주파수를 확보해야 하므로 인접주파수와의 간섭문제가 유발될 수 있다. 또한 이 전구는 교체주기가 긴만큼 본격적인 확산이 이루어지기 전에 해당 주파수를 이용하는 서비스와의 간섭 보호거리 및 방식에 따른 특성 등을 사전에 인지하고 활용함으로써 미래 전파환경에 대비하는 것이 바람직한 것으로 판단된다. 이러한 목적으로 본 논문에서는 250 kHz의 구동 주파수를 갖는 무전극 형광등의 전파간섭 특성에 대해 측정하여 해당 기기의 전파간섭 보호거리를 산출함으로써 무전극 형광등의 안전한 미래 활용에 대비하고자 한다.

  • PDF

방전램프의 역률 보상용 콘덴서를 이용한 저가형 LED 구동회로 (Low-Cost LED Driver Circuit using Power Factor Compensation Capacitor of Discharge Lamp)

  • 고재하;황정구;박성미;박성준
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.16-25
    • /
    • 2013
  • Now it's a trend to install a series of white fluorescent light and orange high pressure sodium lamps because tunnel lighting should be opaque to the safety of drivers from soot, dust, humidity, and fog. Also fluorescent lighting is replaced to LED due to the fact that it improves amenity and object recognition and LED lighting has gradually been improved its nature. In this paper, we have implemented the circuits of the yellow series of high-pressure sodium lamps and white series of LED lights at one board to improve the transparency and recognition of objects. It is possible for inductive high-pressure sodium lamps and the capacitive LED drivers to circuit without power factor compensation. Two circuit parts share only a small number of parts, so low cost LED drivers compared to conventional ones are possible. Therefore, the implementation of the hybrid lighting with high-pressure sodium lamps and LED lights that can be driven at the same time by one driving circuit is possible. The LED capacitive power factor was 0.91 while individually implemented the sodium lamp power factor was 0.98. It shows not only the 2% improvement of hybrid forms but also the efficiency and THD.