• Title/Summary/Keyword: Fluorescent Light Source

Search Result 168, Processing Time 0.026 seconds

Basic Dose Response of Fluorescent Screen-based Portal Imaging Device (섬광판을 사용하는 조사문영상기구의 기본적인 선량반응성)

  • Yeo, In-Hwan J.;Yohannes, Yonas;Zhu,Yunping
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.249-255
    • /
    • 1999
  • Purpose : The purpose of this study is to investigate fundamental aspects of the dose response of fluorescent screen-based electronic portal imaging devices (EPIDS). Materials and Methods : We acquired scanned signal across portal planes as we varied the radiation that entered the EPID by changing the thickness and anatomy of the phantom as well as the air gap between the phantom and the EPID. In addition, we simulated the relative contribution of the scintillation light signal in the EPID system. Results : We have shown that the dose profile across portal planes is a function of the air gap and phantom thickness. We have also found that depending on the density change within the phantom geometry, errors associated with dose response based on the EPID scan can be as high as $7\%$. We also found that scintillation light scattering within the EPID system is an important source of error. Conclusion : This study revealed and demonstrated fundamental characteristics of dose response of EPID, as relative to that of ion chambers. This study showed that EPID based on fluorescent screen cannot be an accurate dosimetry system.

  • PDF

A Study on Growth of the Green Leaf Lettuce Depends on PPFD and Light Quality of LED Lighting Source for Growing Plant (식물재배용 LED 광원의 광질과 PPFD에 따른 청치마상추의 성장에 관한 연구)

  • Yang, Jun-Hyuk;Choi, Won-Ho;Park, Noh-Joon;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.142-147
    • /
    • 2015
  • The artificial light sources for growth of plant are usually high-pressure sodium lamp, metal haloids lamp, and fluorescent light; however, these light sources have relatively weaker Red and Blue lights that are necessary for growth of plants. Especially the effect of Photosynthetic Photon Flux Density (PPFD) is pointed out as the weakness. Meanwhile, LED light source can be selected by specific wavelength to greatly improve the effect of PPFD. In this regard, this paper aims to investigate the promotion of plant growth by measuring photosynthetic photon flux density (hereafter referred to as PPFD) according to changes in light quality of the LED light sources. Towards this end, LED light sources for plant growth were produced with 4 kinds of mono-chromatic lights and 6 kinds of combined lights by mixing red, blue, green and white lights. A comparative analysis was conducted to investigate the effects of optical properties and PPFD on plants (green leaf lettuce) using the produced light sources. The results monochromatic light has fastest growth rate, but plant growth conditions have poor. This being so, mixed light is suitable for the green leaf lettuce.

Growth Characteristics of Microalgae Scenedesmus obliquus by LED Light Source (LED 광원에 따른 미세조류 Scenedesmus obliquus의 성장 특성)

  • Yoo, Yong Jin;Kim, Song Yi;Lee, Geon Woo;Lee, Young Bok;Kim, Jin Woo;Kim, Ho Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.70-77
    • /
    • 2020
  • Microalgae are independent organisms that perform photosynthesis and can alter the culture environment to increase accumulation of useful substances derived from microalgae. In this study, cell growth was measured by incubation for 39 days using MBBM, Neo medium, and seven light sources, which is the main factor affecting cell growth of microalgae S. obliquus. In the case of S. oliquus, which grew in MBBM and Neo medium, cell growth was highest under fluorescent light sources and Red2 LED (R660) light sources, and cell growth was lowest under Infra Red LED (R741) light sources. The average cell growth rate was 17.7% for MBBM and 15.4% for Neo. Comparing the effects of dry cell weight of Neo medium containing nutrients on the production of aquatic plants, MBBM and dry cell weight of Neo resulted in higher cell growth than Neo medium under all LED light sources except for Blue LED (B450). This proves that MBBM is more suitable for increasing the cell growth of microalgae than Neo medium and confirms that light source selection is important in the production of useful materials through mass cultivation of microalgae in the future.

Growth of plug seedlings raised under fluorescent lamps as artificial light source for close illumination (근접조명용 인공광원으로 형광등하에서 육묘된 플러그묘의 생장 특성)

  • 김용현
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.10a
    • /
    • pp.47-54
    • /
    • 1998
  • 인공광형 식물공장의 광원으로는 고압나트륨등, 메탈할라이드등, 형광등이 주로 사용되고 있다. 고압나트륨등과 메탈할라이드등은 램프효율은 높으나 각각 청색광 또는 적색광이 부족하여 식물공장의 근접 조명용 단독 광원으로서는 부적합하다. 형광등은 고압나트륨등과 같은 고휘도 방전등에 비해서 광속은 낮으나 광이용효율이 높기 때문에 조직배양묘의 광원으로 널리 사용되고 있다. (중략)

  • PDF

Technology Trend and Prospect of Electrodeless Lamp (무전극 램프의 기술동향과 전망)

  • 황명근;이종찬;박대희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.23-26
    • /
    • 2001
  • 1879년 T. Edison이 백열전구(incandescent lamp)의 발명, 1920년대에는 형광램프(fluorescent lamp)의 개발에 이어 1990년대에는 무전극(electrodeless) 형광램프가 처음으로 실용화 되어진 비교적 새로운 광원(light source)으로 종래의 광원이 지니지 못하는 특징들이 있다. 본 보고는 그의 원리와 특징, 실용화, 제 문제점 등을 소개하고, 금후의 전망에 대하여 언급한다.

  • PDF

Fabrication of high brightness multi-lamp backlight system for a large size LCD panel inspection equipment

  • Chun, Young-Tea;Lim, Sung-Kyoo;Lee, Kwang-Kyu;Lee, Hwan-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.787-790
    • /
    • 2004
  • The large size and high brightness backlight system for LCD panel inspection equipment was designed, fabricated, and evaluated. The cold cathode fluorescent lamp (CCFL) instead of the hot cathode fluorescent lamp (HCFL) were used as the light source. The inverters for driving multi-lamp CCFL backlight systems were also designed and fabricated. The measured luminance of the fabricated CCFL backlight system was 20,000 cd/$m^2$ and the uniformity of the backlight was 85%. The fabricated backlight system was successfully applied to the LCD panel inspection equipment.

  • PDF

A new Areal Selective Dimming Method of Mercury-free Flat Fluorescent Lamps for LCD Backlighting

  • Jung, Jae-Chul;Seo, In-Woo;Oh, Byung-Joo;Kim, Hyuck;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1189-1192
    • /
    • 2008
  • A new mercury-free flat fluorescent lamp with a single cell having dimension 2.2inches across the diagonal, had been developed which shows a wide, stable operating voltage margin, high luminance and luminous efficacy by adopting the bipolar pulse drive scheme. In this paper, the single cell is expanded into a multi-structured configuration to realize a 32inch sized panel across the diagonal by a simple repetition of the single cells. A driving scheme is proposed for a 2-bit areal selective dimming using dual auxiliary electrodes and bipolar drive scheme.

  • PDF

Simultaneous measurement of velocity and temperature fields in micro-scale flow and its application to electrokinetic flow (마이크로 스케일 유동에서의 속도장 온도장 동시 측정 기법과 동전기 유동에의 적용)

  • Lee, Beom-Joon;Jin, Song-Wan;Kim, Young-Won;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2585-2590
    • /
    • 2007
  • In this paper, a technique of simultaneously measuring the velocity and the temperature in micro-scale flow is proposed. This method uses particle tracking velocimetry (PTV) for measuring the velocity and laser induced fluorescence (LIF) for measuring the temperature. To measure the accurate velocity and temperature, images for PTV and for LIF are separated by using two light sources and a shutter which is synchronized with a camera. By using only one camera, measurement system can be simplified and the error from complicate optical system can be minimized. Error analyses regarding the concentrations of fluorescent dye and particle and the light source fluctuation are also conducted. It is found that the error of the temperature and the velocity highly depends on the concentration of fluorescent particles which are used for PTV. This technique is applied to the simultaneous measurement of the velocity and the temperature in the electrokinetic flow. It is found that the velocity and temperature vary with the electric field strength and the concentration of electrolyte.

  • PDF

Simultaneous Measurement of Velocity and Temperature Fields in Micro-Scale Flow and Its Application to Electrokinetic Flow (마이크로 스케일 유동에서의 속도장 온도장 동시 측정 기법과 동전기 유동에의 적용)

  • Lee, Beom-Joon;Jin, Song-Wan;Kim, Young-Won;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.7 s.262
    • /
    • pp.644-652
    • /
    • 2007
  • In this paper, a technique of simultaneously measuring the velocity and the temperature in micro-scale flow is proposed. This method uses particle tracking velocimetry (PTV) for measuring the velocity and laser induced fluorescence (LIE) for measuring the temperature. To measure the accurate velocity and temperature, images for PTV and for LIE are separated by using two light sources and a shutter which is synchronized with a camera. By using only one camera, measurement system can be simplified and the error from complicate optical system can be minimized. Error analyses regarding the concentrations of fluorescent dye and particle and the light source fluctuation are also conducted. It is found that the error of the temperature and the velocity highly depends on the concentration of fluorescent particles which are used for PTV. This technique is applied to the simultaneous measurement of the velocity and the temperature in the electrokinetic flow. It is found that the velocity and temperature vary with the electric field strength and the concentration of electrolyte.

The Effect of Color Reproduction Properties at TFT-LCD using High Color Reproduction CCFL

  • Han, Jeong-Min;Ok, Chul-Ho;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.215-217
    • /
    • 2007
  • Recently, color reproduction properties have attracted lots of attention with mass production of LCD especially corresponding to TV application and achievement of color reproduction properties such as CRT have been considered one of technical goals for high quality display. However, revision of the color reproduction properties only with CF(color filter) have fundamental limitations and resultant decrease in the transmittance of panel causes demand on high brightness of BL(Back Light). In this paper, we present such a method in which by optimization of original light spectrum from the BL source will improves the color reproduction properties corresponding to them of the CRT. When the intensity of RED and Green-Blue from ramp is revised densely, the characteristics different from CCFL(Cold Cathode Fluorescent Lamp) used before become added so that about 11 % of the color reproduction properties is improved compare to the existing LCD panel.