• Title/Summary/Keyword: Fluorescence sensor

Search Result 137, Processing Time 0.027 seconds

Imaging of self-assembled monolayers by surface plasmon microscope (표면 플라즈몬 현미경을 이용한 자기조립 단분자막의 이미징)

  • 표현봉;신용범;윤현철;양해식;김윤태
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.97-102
    • /
    • 2003
  • Multi-channel images of 11-MUA(11-Mercaptoundecanoic acid) and 11-MUOH(11-Mercaptoundecanol) self-assembled monolayers were obtained by using two-dimensional surface plasmon resonance (SPR) absorption. The patterning process was simplified by exploiting direct photo-oxidation of thiol bonding (photolysis) instead of conventional photolithography. Sharper images were resolved by using a white light source in combination with a narrow bandpass filter in the visible region, minimizing the diffraction patterns on the images. The line profile calibration of the image contrast caused by different resonance conditions at each point on the sensor surface (at a fixed incident angle) enables us to discriminate the monolayer thickness in nanometer scale. Furthermore, there is no signal degradation such as photo bleaching or quenching, which are common in the detection methods based on fluorescence.

Comparison of organic EL characteristics of low mass dye and polymer material with the same chromophore (동일한 발광기를 가진 저분자색소와 고분자물질의 유기 EL특성의 비교)

  • Kim, Dong-Uk
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 1999
  • A Polymer material, PU-BCN and a low molar mass material D-BCN with the same chromophore were evaluated by fabricating various electroluminescent(EL) devices. A molecular structure of the chromophore was composed as two cyano groups for electron-injection and transport and two triphenylamine groups for hole-injection and transport. Various kinds of EL devices with two different types of EL materials, PU-BCN and D-BCN were fabricated, which were an Indium-tin oxide(ITO)/PU-BCN or D-BCN/MgAg device as a single-layer device(SL) and an ITO/PU-BCN or D-BCN/oxadiazole ferivative/MgAg as a double-layer device(DL-E) and an ITO/triphenylamine derivative/D-BCN/MgAg as a double-layer device(DL-H) device. Two kinds of materials, PU-BCN and D-BCN showed the same emission characteristics in the high current density and excellent EL characteristics even in the SL devices. Maximum EL peaks revealed red emission of about 640 nm, which were corresponded with the fluorescence peaks of the films of two materials.

  • PDF

A Study on the Correlation between the Harmful Cyanobacterial Density and Phycocyanin Concentration at Recreational Sites in Nakdong River (낙동강 친수활동구간 유해 남조류 분포와 피코시아닌(Phycocyanin) 농도 상관성에 관한 연구)

  • Hyo-Jin Kim;Min-Kyeong Kim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.6
    • /
    • pp.451-464
    • /
    • 2023
  • Harmful cyanobacterial monitoring is time-consuming and requires skilled professionals. Recently, Phycocyanin, the accessory pigment unique to freshwater cyanobacteria, has been proposed as an indicator for the presence of cyanobacteria, with the advantage of rapid and simple measurement. The purpose of this research was to evaluate the correlation between the harmful cyanobacterial cell density and the concentration of phycocyanin and to consider how to use the real-time water quality monitoring system for algae bloom monitoring. In the downstream of the Nakdong River, Microcystis spp. showed maximum cell density (99 %) in harmful cyanobacteria (four target genera). A strong correlation between phycocyanin(measured in the laboratory) concentrations and harmful cyanobacterial cell density was observed (r = 0.90, p < 0.001), while a weaker relationship (r = 0.65, p < 0.001) resulted between chlorophyll a concentration and harmful cyanobacterial cell density. As a result of comparing the phycocyanin concentration (measured in submersible fluorescence sensor) and harmful cyanobacterial cell density, the error range increased as the number of cyanobacteria cells increased. Before opening the estuary bank, the diurnal variations of phycocyanin concentrations did not mix by depth, and in the case of the surface layer, a pattern of increase and decrease over time was shown. This study is the result of analysis when Microcystis spp. is dominant in downstream of Nakdong River in summer, therefore the correlation between the harmful cyanobacteria density and phycocyanin concentrations should be more generalized through spatio-temporal expansion.

Signal Analysis of Optical Biosensor to Detect Peroxide Using Electrically Controlled Release System (전기적 방출 조절 시스템을 이용한 광 페록사이드센서의 개발)

  • Min, Jun-Hong;Lim, In-Hee;Kim, Hyo-Han;Lee, Sang-Beak;Choi, Jeong-Woo;Lee, Won-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.35-42
    • /
    • 1997
  • The optical biosensor using the electrically controlled release of reactive reagent is developed for the detection of peroxide. Rapid degradation of polymer complex of PEOx and PMAA occurs as the applied current increases and thus released amount of HPA increases. The degradation velocity of polymer and the amount of HPA released are linearly proportional to the applied current. Peroxide is reacted with the released reagent by peroxidase and then the product, a fluorescent dimer DBDA, is formed. The monochromic light from light source (150W Xe arc ramp) excites the DBDA and the excited light is transmitted through an optical fiber to be detected by a photodiode array. The change of fluorescence intensity is related to the change of peroxide concentration. The peroxidase is entrapped in Ca-alginate get on the inner surface. The biosensor has the linear signal range of 0.025mM-10.mM peroxide. By applying the step function of peroxide, reproducibility of biosensor has been investigated. The mathematical model is constructed by the combination of enzyme kinetics with reactor flow model. Good agreement is obtained between the experimental result and model prediction in the sensor signal.

  • PDF

Current Statues of Phenomics and its Application for Crop Improvement: Imaging Systems for High-throughput Screening (작물육종 효율 극대화를 위한 피노믹스(phenomics) 연구동향: 화상기술을 이용한 식물 표현형 분석을 중심으로)

  • Lee, Seong-Kon;Kwon, Tack-Ryoun;Suh, Eun-Jung;Bae, Shin-Chul
    • Korean Journal of Breeding Science
    • /
    • v.43 no.4
    • /
    • pp.233-240
    • /
    • 2011
  • Food security has been a main global issue due to climate changes and growing world population expected to 9 billion by 2050. While biodiversity is becoming more highlight, breeders are confronting shortage of various genetic materials needed for new variety to tackle food shortage challenge. Though biotechnology is still under debate on potential risk to human and environment, it is considered as one of alternative tools to address food supply issue for its potential to create a number of variations in genetic resource. The new technology, phenomics, is developing to improve efficiency of crop improvement. Phenomics is concerned with the measurement of phenomes which are the physical, morphological, physiological and/or biochemical traits of organisms as they change in response to genetic mutation and environmental influences. It can be served to provide better understanding of phenotypes at whole plant. For last decades, high-throughput screening (HTS) systems have been developed to measure phenomes, rapidly and quantitatively. Imaging technology such as thermal and chlorophyll fluorescence imaging systems is an area of HTS which has been used in agriculture. In this article, we review the current statues of high-throughput screening system in phenomics and its application for crop improvement.

광학 분석 시스템용 수.발광 소자 집적 모듈 개발

  • Song, Hong-Ju;Lee, Jun-Ho;Park, Jong-Hwan;Han, Cheol-Gu;Park, Jeong-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.311-312
    • /
    • 2012
  • 본 발표에서는 광학적 분석 시스템에 적용 가능한 발광소자(광원)과 수광소자(광센서)를 집적화시키는 모듈(수 발광 집적모듈) 기술을 제시하고자 한다. 이러한 수-발광 집적모듈은 다양한 응용 분야에 적용 될 수 있다. 예를 들어, 광신호 감지를 위한 광통신용 송-수신 모듈(optical communication), 의료/진단 분야에서 단백질/DNA/박테리아 등의 검출 및 분석에 관한 바이오 센서(bio-sensor), 그리고 대기(가스)/수질 모니터링에 관한 환경센서 등 매우 광범위한 분야에 해당되는 요소 기술이라 할 수 있다. 특히, 이들 분야들 중 바이오 물질을 분석하고 검출하는 광학적 바이오 센서 기술은 높은 경제적 가치와 산업적 성장 잠재력으로 인해 오랫동안 활발한 연구가 진행되어 오고 있다. 이러한 광학적 바이오 센서에서 가장 범용적인 방법 중 하나가 항온-항체 면역반응을 기반으로 하는 형광 검출(fluorescence detection) 기법이다. 이러한 시스템은 전체적으로 광원, 광학계, 그리고 센서로 구성되는데 기존에 일반적으로 사용되고 있는 형광 현미경의 경우는 민감도가 우수하다는 장점은 있으나 상당히 고가이고 부피가 크며 복잡한 광학구성으로 이루어져 있다는 한계점을 가지고 있다. 이러한 맥락에서 고민감도를 확보하면서 휴대성, 고속처리, 저가 등의 특성을 가진 시스템에 대한 요구가 갈수록 증가하고 있다. 이를 해결하기 위한 핵심기술 중의 하나가 수-발광 부분을 집적화 시키는 기술이라 할 수 있다. 본 연구에서는 바이오 센서 기술의 하나로서 형광을 측정하여 혈액내의 진단 지표인자를 검출할 수 있는 휴대용 혈액진단기기에 적용되는 소형 수 발광 집적 모듈을 개발하였다. 혈액내의 검출 성분의 양에 따라 형광의 세기가 변화하게 됨으로써 정량적인 검출이 가능한 원리이다. 모듈의 구조는 크게 광원(발광소자), 광학계, 그리고 광센서(수광소자) 세 영역으로 나누어 진다. 광원은 635 nm 적색 레이저다이오드로서 형광체(Alexa Fluor 647/발광파장: 668 nm)를 여기 시키는 기능을 하며 장착된 볼렌즈 의해 샘플의 형광체 영역으로 집광된다. 광학계는 크게 시준렌즈(collimating lens)와 광학필터로 구성됨으로써 샘플로부터 발생되는 광을 적절하게 수광소자로 전달하는 기능을 하게 된다. 여기서 광학필터의 경우는 기본적으로 Distributed Bragg's Reflector(DBR) 구조로써 실리콘(Si) 포토다이오드 상부에 모노리식(monolithic)하게 형성되며 검출 샘플로부터 진행되는 레이저 광(잡음의 주원인)은 차단하고 형광(광신호)만 통과 시키는 기능을 하게 된다. 따라서 신호 대 잡음비(S/N ratio)를 향상시키기 위해서는 정밀한 광 필터링 기능이 요구됨으로써 박막의 세밀한 공정 조건과 구조적-광학적 특성 분석이 수행되었다. 마지막으로 포토다이오드 소자는 일반적인 구조 이외에 중앙에 원형 구멍이 형성된 특별한 구조가 적용된다. 이것은 포토다이오드 구조에 변화를 줌으로써 모듈 구조를 효율적으로 응용할 수 있다는 의미를 갖는다. 또한 포토다이오드의 전기적-광학적 측정 분석을 통해 잡음 및 감도 특성이 세부적으로 조사되며 형광신호를 효과적으로 측정할 수 있음을 확인하였다. 최종적으로 제작된 모듈은 약 $1{\times}1{\times}1cm^3$ 내외 정도의 크기를 갖는다. 요약하자면 본 발표에서는 광학적 바이오센서에 적용할 수 있는 소형 수-발광 소자 집적모듈을 소개한다. 전체 모듈 설계는 최소한의 부피를 가짐과 동시에 측정의 정밀성을 향상시키는데 초점을 맞추어 진행하였다. 세부요소인 광학필터와 포트다이오드의 경우 잡음 및 민감도에 미치는 중요성 때문에 세밀한 공정 및 특성분석이 수행되었다. 결론적으로 독자적인 설계 및 공정을 통해 휴대성 및 정밀성 등의 목적에 부합한 경쟁력 있는 수-발광 소자 집적모듈 제작 기술을 확보하였다.

  • PDF

오일샌드 저류층 지질특성화를 위한 기초연구 소개

  • Choe, Jae-Yong;Kim, Dae-Seok;Gwon, Lee-Gyun;Jeong, Gong-Su
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.106-106
    • /
    • 2010
  • 오일샌드는 비투멘(bitumen), 물, 점토, 모래의 혼합체로 이루어진 비재래형 탄화수소 자원으로 세계적인 고유가 시대에 큰 관심을 받고 있는 석유자원 중 하나이다. 오일샌드는 대부분이 캐나다 앨버타주에 분포하고 있으며 주요 저류층으로는 아스바스카(Athabasca), 콜드레이크(Cold Lake) 지역의 멕머레이층(McMurray Formation), 클리어워터층(Clearwater Formation), 그랜드래피드층(Grand Rapid Formation)과 피스리버(Peace River) 지역의 블루스카이층(Bluesky Formation), 게팅층(Gathing Formation)이 있다. 오일샌드 저류층은 고생대 탄산염 기반암 위에 하성-에스츄어리에 이르는 다양한 퇴적환경에서 형성되어 매우 복잡한 지질특성이 나타난다. 오일샌드 저류층의 효율적인 개발을 위해서는 저류층의 복잡한 지질학적 특성의 이해가 반드시 필요하다. 본 연구에서 캐나다 오일샌드 시추코어 분석 DB, 물리검층 자료, 현장 및 현생 시추코어를 통하여 오일샌드 저류층의 지질특성화 정보의 도출을 시도하였다. 우선 캐나다 앨버타 전역에 분포하는 시추공의 기본 정보(표고, 위경도, 층서별 최상부 심도, 생산광구명, 광구개발업체)를 제공하는 AccuMap DB 프로그램을 이용하여 광역적인 오일샌드 저류층의 분포 특성을 이해하고자 주요층서에 대한 고지형도 및 층후도를 생산광구별로 도면화하여 분석하였다. 또한 캐나다 ENCANA사와 국제공동연구의 일환으로 확보된 크리스티나 레이크(Christina Lake)광구의 현장 시추코어를 이용하여 코어의 상세기재, 비파괴 물성측정, 입도/비투멘 함유량 분석과 같은 다양한 실내 시추코어분석 실험을 수행 중이다. 비파괴 물성측정은 현장 시추코어의 물리적/화학적 특성을 파악하고자 MSCL(Multi sensor core logger)과 XRF 코어 스캐너(X-ray fluorescence core scaner)를 통해 이루어지며, 분석결과로 시추코어의 감마밀도(gamma density), P파 속도(P-wave velocity), 전기비저항(resistivity), 대자율(magnetic susceptibility) 및 색지수의 물성과 정량적 화학조성을 측정한다. 현장 시추코어의 일부는 유기용매를 이용하여 퇴적물 내의 비투멘을 완전히 추출하고 퇴적물 입도와 저류층 비투멘 함유량 측정에 이용되었다. 현장 시료 분석 결과들은 물리검층 자료와 대비를 통하여 저류층의 지질특성을 규명하는 연구에 이용될 예정이다. 마지막으로 오일샌드의 현생 유사 퇴적환경으로 알려진 서해 경기만 조간대에서 시추코어 퇴적물을 획득하여 상세 기재하였으며, 이를 통해 오일샌드 저류층의 퇴적 모델을 제시하고자 퇴적층서 연구를 진행 중이다. 향후 오일샌드 관련 시추코어의 분석 결과들이 종합되면 기존 보다 비투멘 회수효율을 향상시킬 수 있는 정밀한 오일샌드 저류층 지질모델을 수립할 수 있을 것으로 기대된다.

  • PDF