• Title/Summary/Keyword: Fluorescence method

Search Result 1,013, Processing Time 0.032 seconds

Quantitation of Antigen-Antibody Reaction Condition for Development of Fluorescence Image-based CD4 Rapid Test (형광 영상 기반 CD4 신속 검사법 개발을 위한 항원-항체 반응 조건 정량화)

  • Kim, Subin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.1
    • /
    • pp.35-42
    • /
    • 2015
  • CD4+ T-cell count determines the effectiveness for antiretroviral therapy (ART) in patients with human immunodeficiency virus (HIV). Although ART slows the progression of HIV to AIDS, rapid counting of CD4+ T lymphocytes with a drop of patient's blood sample is urgently needed to ensure timely ART treatment in rural areas. Recently point-of-care CD4 testing devices have been developed by using non-flow based imaging cytometer incorporated with a sample cartridge where CD4+ T cells are reacted with fluorescently tagged specific antibodies. Here we conducted an experimental study using a conventional fluorescence microscope-based imaging system to quantitate the interaction of CD4 antibodies with CD4+ T cells at different reaction conditions. We demonstrated that a fast and affordable point-of-care CD4 test is feasible with a far less amount of antibodies and a shorter incubation time compared with a conventional sample preparation protocol for flow cytometry. We also proposed a general method to evaluate and compare the detection limit across different CD4 counting platforms by using fluorescently labelled microbeads for intensity calibration.

Remote Real-Time Uranium Concentration Measurement Using the Nitrogen Laser and optode (질소레이저와 광섬유를 이용한 원격제어 실시간 우라늄 농도 측정)

  • Lee, Sang-Mock;Shin, Jang-Soo;Lee, Su-Mi;Koh, Kwang-Nak;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.362-368
    • /
    • 1997
  • The remote real-time uranium concentration analysis using nitrogen laser, optode, photomultiplier and optical fiber is studied. The optode for the remote collection of uranium fluorescence is designed. The fluorescence intensity at time zero is calculated in order to exclude the quenching effect and the temperature fluctuation and used for more precise estimation. The fluorescence change is very sensitive to the uranium concentration change. The method shows the detection limit of 0.06ppm and the linearity between 0.1ppm and 2ppm of the aqueous uranium concentration.

  • PDF

Sex Determination of In Vitro Fertilized Bovine Embryos by Fluorescence In Situ Hybridization Technique

  • Han, M.S.;Cho, E.J.;Ha, H.B.;Park, H.S.;Sohn, S.H.
    • Reproductive and Developmental Biology
    • /
    • v.28 no.2
    • /
    • pp.133-137
    • /
    • 2004
  • Sexing from bovine embryos which were fertilized in vitro implicate a possibility of the sex-controlled cattle production. This study was carried out to investigate the possibility of determining of embryo sex by fluorescence in situ hybridization (FISH) technique. FISH was achieved in in vitro fertilized bovine embryos using a bovine Y-specific DNA probe which constructed from the btDYZ-1 sequences. To evaluate Y-chromosome specificity of the FISH probe, metaphase spreads of whole embryos and lymphocytes were prepared and tested. A male-specific signal was detected on 100% of Y chromosome bearing metaphase specimens. Using the FISH technique with a bovine Y-specific probe, 232 whole embryos of 8 cell- to blastocyst-stage were analyzed. Observing the presence of the Y-probe signal on blastomeres, 102 embryos were predicted as male, and 130 embryos as female. The determining rate of embryo sex by FISH technique was about 93% regardless of embryonic stages. In conclusion, the FISH using a bovine Y-specific DNA probe is an accurate, reliable and quick method for determining the sex of bovine embryos.

Distribution Patterns in the Tumor Tissue and Normal Tissue according to the Administration Methods of ALA and ALA-Methylester (ALA 및 ALA-Methylester의 투여에 따른 종양조직 및 정상조직에의 분포양상에 대한 연구)

  • Chung Phil-Sang;Jung Sang-Oun;Ahn Jin-Chul;Lee Sang-Joon;Yoon Jun-Sik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.21-24
    • /
    • 2003
  • Objectives: In this report, we confirmed the distributed pattern of ALA and ALA-methylester in normal and tumor-bearing region. Materials and Methods: ALA and ALA-methylester were administered to nude mouse by intratumoral, subcutaneous and intravenous injection. After injection, the fluorescence in normal and tumor region was measured by LESA (laser electronic spectrum analyzer). Results: The tumor-specificity of ALA and ALA-methylester was shown in the case of intratumoral injection. In all case, the fluorescence caused by ALA and ALA-methylester was maximally increased in 2 hours after injection. Then while the fluorescence level was rapidly decreased to control level in normal region, it was still remained in tumor region. Conclusion: According to this result, The intratumoral injection was more efficient administration method for PDT/PDD than subcutaneous and intravenous injection.

Kinetic Study on the Low-lying Excited States of Ga Atoms in Ar

  • Kuntack Lee;Ju Seon Goo;Ja Kang Ku
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.8
    • /
    • pp.663-669
    • /
    • 1994
  • Decay kinetics of Ga(5s), Ga(5p) and Ga(4d) atoms in Ar were studied by laser induced fluorescence technique. Theground state gallium atoms in the gas phase were generated by pulsed dc discharge of trimethyl gallium and argon mixtures. Both pulsed discharge and YAG-DYE laser system were controlled by a dual channel pulse generator and the delay time between the end of discharge and laser pulses was set 3.0-6.0 ms. The Ga(5s) and Ga(4d) atoms were generated by single photon excitation from the ground state Ga atoms and radiative lifetimes as well as the total quenching rate constants in Ar were obtained from the pressure dependence of the fluorescence decay rates. The Ga(5p) atoms were populated by a two-photon excitation method and the cascade fluorescence from Ga(5s) atoms were analyzed to extract quenching rate constant of Ga(5p) atoms by Ar in addition to radiative lifetimes of Ga(5p) state. The magnitudes of the quenching rate constants by Ar for the low-lying excited states of Ga atoms are 1.6-3$ {\times}10^{-11}cm^3$ molecul$e^{-1}s^{-1}$, which are much larger than those for alkali, alkaline earth and Group 12 metals. Based on the measured rate constants, kinetic simulations were done to assign state-to-state rate constants.

Development of a pH/dissolved- oxygen Monitoring System Using HPTS and Rudpp (HPTS, Rudpp를 활용한 pH 및 용존산소 모니터링 시스템 연구)

  • Dong Hyuk Jeong;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.82-87
    • /
    • 2023
  • This study proposes a pH-dissolved-oxygen monitoring system using 8-HydroxyPyrene-1,3,6-trisulfonic acid Trisodium Salt (HPTS) and tris(4,7-diphenyl-1,10-phenanthroline)Ruthenium(II) chloride (Rudpp). Commercial water-quality sensors are electrochemical devices that require frequent calibration and cleaning, are subject to high maintenance costs, and have difficulties conducting measurements in real-time. The proposed pH-dissolved-oxygen monitoring system selects a thin-film sensing layer to measure the change in fluorescence intensity. This change in fluorescence intensity is based on reactions with hydrogen ions in an aqueous solution at a given pH and specific amount of dissolved oxygen. The change in fluorescence intensity is then measured using light-emitting diodes and photodiodes in response to HPTS and Rudpp. This method enables the development of a relatively small, inexpensive, and real-time measureable water-quality measurement system.

Development of a Fluorescence Measurement System Capable of Rapid Red Tide Monitoring (신속한 적조 예찰이 가능한 형광 측정시스템 개발)

  • Kyung-hoon Baek;Yeongji Oh;Hyeonseo Cho;Yoonja Kang;Joon-seok Lee
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.30-33
    • /
    • 2024
  • The occurrence of harmful algae on the coast of Korea has been a cause of damage to the aquaculture industry and deterioration of the coastal ecosystem environment. A method is required to predict their outbreak in real-time at the site. Therefore, this study attempted to develop a small hybrid optical sensor and real-time monitoring system based on LiDAR that can be used in the field and laboratory and can be applied to various platforms. FMS-L specifically suggested the amount of Chlorophyll a (Chl a) in the sample by measuring and analyzing the fluorescence emitted by the irradiating light. The accuracy of FMS-L was verified by measuring the concentrations of standard Chlorophyll a substances and Margalfidinium polykirkoids. In addition, the precision was verified by comparing the measurement results of FMS-L using commercial equipment Phyto-PAM-II. This equipment is compact and easy to move. Therefore, it can be easily applied to field surveys, allows short time measurements (10 s), and can be applied at a distance of 10 m from the measurement site.

A study on simultaneous determination of carbamate pesticides by HPLC (HPLC를 이용한 carbamate계 농약의 다성분 동시분석)

  • Song, Young-Gak;Seo, Young-Chul;Hyun, Gong-Yul;Cho, Woo-Young;Lee, Jong-In
    • Korean Journal of Veterinary Service
    • /
    • v.26 no.2
    • /
    • pp.145-149
    • /
    • 2003
  • To explore the most sensitive and useful method for simultaneous determination of 8 carbamate pesticides in livestock productions, the mixture of 8 carbonates was determined by HPLC with scanning fluorescence detector. For mobile phase water, acetonitrile and methanol program gradient showed more applicable sensitivity than water and acetonitrile program gradient used ExW 339 nm and EmW 445 nm for fluorescence detector. On using carbamate columns, the retention time was within 4 to 20 minutes. And this made it possible to separate and detect simultaneously. therefore we could analyze it exactly and efficiently and reduce time. The preparation process of MSPD method showed that the high recovery rate was more than 88.5% in most of the carbamate pesticides. Therefore we could say that it was an efficient and fast method analyzing out of lots of samples.

X-ray fluorescence spectrum of the block algorithm to apply the interval threshold method using DWT (DWT를 이용한 형광 X-선 스펙트럼의 interval Threshold를 적용하기 위한 블록화 알고리즘)

  • Yang, Sang-Hoon;Lee, Jae-Hwan;Park, Dong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2291-2297
    • /
    • 2012
  • X-ray fluorescence sprectrum signal include the continuum. XRF analysis the components of material by the amplitude of peaks. XRF remove the noise and background. To remove the noise, we apply the smoothing filter. And background removal methods applied such as SNIP, Morphology, Threshold methods. In this paper, we applied Threshold using DWT. Interval threshold method divide the some blocks in particular levels. We propose the method that is divided the particular level.

Lane Detection and Tracking Algorithm for 3D Fluorescence Image Analysis (3D 형광이미지 분석을 위한 레인 검출 및 추적 알고리즘)

  • Lee, Bok Ju;Moon, Hyuck;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.1
    • /
    • pp.27-32
    • /
    • 2016
  • A new lane detection algorithm is proposed for the analysis of DNA fingerprints from a polymerase chain reaction (PCR) gel electrophoresis image. Although several research results have been previously reported, it is still challenging to extract lanes precisely from images having abrupt background brightness difference and bent lanes. We propose an edge based algorithm for calculating the average lane width and lane cycle. Our method adopts sub-pixel algorithm for extracting rising-edges and falling edges precisely and estimates the lane width and cycle by using k-means clustering algorithm. To handle the curved lanes, we partition the gel image into small portions, and track the lane centers in each partitioned image. 32 gel images including 534 lanes are used to evaluate the performance of our method. Experimental results show that our method is robust to images having background difference and bent lanes without any preprocessing.