• 제목/요약/키워드: Fluorescence intensity

검색결과 577건 처리시간 0.024초

PLIF를 이용한 희박연소엔진에서의 연료 성층화에 관한 연구 (Fuel Stratification Process in a Lean Burn Internal Combustion Engine by Using Planar Laser Induced Fluorescence)

  • 정경석
    • 한국자동차공학회논문집
    • /
    • 제11권3호
    • /
    • pp.7-12
    • /
    • 2003
  • Mixture formation in the cylinder of a lean bum engine has been observed by Laser Induced Fluorescence technique. XeCl laser (308nm) was used to produce a laser sheet. 3-pentanone has been added to iso-octane fuel to produce fluorescence, the intensity of which is proportional to the concentration of the fuel. The laser sheet was introduced through the piston window and the fuel distribution in the vertical plane was observed through a side window. Comparison has been made for the cases of selected fuel injection timing as 0, 360, 405, and 450 CA. For the case of 0 and 360 CA injection, uniform fuel distribution in the combustion chamber has been obtained at the ignition time which is favorable for the high load mode. And the late injection cases, 405 and 450 CA, revealed the stratified formation of rich mixture around the spark plug. That extends the lean misfire limit and reduces cyclic variation in the low load mode.

CdTe Quantum Dots as Fluorescent Probes for Josamycin Determination

  • Peng, Jinyun;Nong, Keliang;Mu, Guangshan;Huang, Fengying
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2727-2731
    • /
    • 2011
  • A new method for the determination of josamycin has been developed based on quenching of the fluorescence of 3-mercaptopropionic acid-capped CdTe quantum dots (MPA-CdTe QDs) by josamycin in ethanol. Reaction time, interfering substances on the fluorescence quenching, and mechanism of the interaction of CdTe QDs with josamycin were investigated. Under optimum conditions, the relative fluorescence intensity was linearly proportional to the concentration of josamycin between 12.0 and 120.0 ${\mu}g\;mL^{-1}$ with a correlation coefficient of 0.9956 and a detection limit of 2.5 ${\mu}g\;mL^{-1}$. The proposed method was successfully applied to commercial tablets, and the results were satisfactory, i.e. consistent with those of high-performance liquid chromatography (HPLC).

강산성 용액의 pH를 측정할 수 있는 미셀기반의 형광센서 개발 (Self-assembled Micelle-based Fluorescence Sensor for Extremely Acidic pH Range)

  • 이정무;이성호
    • 한국환경과학회지
    • /
    • 제29권8호
    • /
    • pp.801-808
    • /
    • 2020
  • In this study, an effective fluorescence pH sensor based on conjugated polyelectrolyte micelles (CPMs) was devised for detecting extremely acidic conditions. An amphiphilic coumarin derivative (CC12-N), a building block, was prepared, into which an ionizable amino group, aryl amine, was incorporated as a potential hydrophilic moiety. This monomer displays self-assembled micelle formation in extremely acidic pH ranges, giving a hydrophobic π-extended conjugated system at the inner part and hydrophilic functionality at the periphery, resulting in efficient fluorescence intensity enhancement. This new micelle-based fluorescence provides an efficient sensing platform for detecting very low pH values in the presence of competing substances.

Measurements of Temperature and Flow Fields with Sub-Millimeter Spatial Resolution Using Two-Color Laser Induced Fluorescence (LIF) and Micro-Particle Image Velocimetry (PIV)

  • Kim Hyun Jung
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.716-727
    • /
    • 2005
  • Comprehensive measurements for velocity and temperature fields have been conducted. A Micro PIV 2-color LIF system have been setup to measure the buoyancy driven fields in a 1-mm heated channel with low Grashof-Prandtl numbers [$86]. Fluorescence microscopy is combined with an MPIV system to obtain enough intensity images and clear pictures from nano-scale fluorescence particles. The spatial resolution of the Micro PIV system is $75{\mu}m\;by\;67{\mu}m$ and error due to Brownian motion is estimated $1.05\%$. Temperature measurements have achieved the $4.7\;{\mu}m$ spatial resolution with relatively large data uncertainties the present experiment. The measurement uncertainties have been decreased down to less than ${\pm}1.0^{\circ}C$ when measurement resolution is equivalent to $76\;{\mu}m$. Measured velocity and temperature fields will be compared with numerical results to examine the feasibility of development as a diagnostic technique.

SPECTRAL AND PROTOPHYSICAL PROPERTIES OF 1-PYRAZINYL-2-(3- QUINOLINYL)ETHYLENE

  • Bong, Pill-Hoon;Ryoo, Jae-Hwan
    • Journal of Photoscience
    • /
    • 제6권4호
    • /
    • pp.171-176
    • /
    • 1999
  • The spectral and photophysical properties of trans-1-pyrazinyl-2-(3-quinolinyl)ethylene (trans-3- PyQE) are investigated under various conditions in order to obtain information on ground and excited states. The absorption spectrum of trans-3-PyQE changes slightly with varying degree of solvent polarity ; the. fluorescence spectrum is shifted to the red and becomes broad and structureless as the solvent polarity increases. The fluorescence quantum yield increases with increasing solvent polarity. The fluorescence intensity of trans-3-PyQE decreases as the concentration of methyl iodide increases. The fluorescence spectra of trans-3-PyQE changes markedly upon the variation of the excitation wavelength, presumably due to an equilibrium between conformers originating from the rotation of a quasi-single bond between the quinolinyl group and ethylenic carbon atom. These results indicate that the spectral and photophysical properties of trans-3-PyQE are strongly influenced by solvent, heavy atom, and an equilibrium between conformers

  • PDF

Aeration Control of Thermophilic Aerobic Digestion Using Fluorescence Monitoring

  • Kim, Young-Kee;Oh, Byung-Keun
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권1호
    • /
    • pp.93-98
    • /
    • 2009
  • The thermophilic aerobic digestion (TAD) process is recognized as an effective method for rapid waste activated sludge (WAS) degradation and the deactivation of pathogenic microorganisms. Yet, high energy costs due to heating and aeration have limited the commercialization of economical TAD processes. Previous research on autothermal thermophilic aerobic digestion (ATAD) has already reduced the heating cost. However, only a few studies have focused on reducing the aeration cost. Therefore, this study applied a two-step aeration control strategy to a fill-and-draw mode semicontinuous TAD process. The NADH-dependent fluorescence was monitored throughout the TAD experiment, and the aeration rate shifted according to the fluorescence intensity. As a result, the simple two-step aeration control operation achieved a 20.3% reduction in the total aeration, while maintaining an effective and stable operation. It is also expected that more savings can be achieved with a further reduction of the lower aeration rate or multisegmentation of the aeration rate.

Synthesis of Chemosensor Based on Pyrene and Study for Its Sensing Properties Toward Fluoride Ion

  • Kim, Hyungjoo;Li, Xiaochuan;Son, Young-A
    • 한국염색가공학회지
    • /
    • 제25권3호
    • /
    • pp.153-158
    • /
    • 2013
  • In this study, pyrene based chemosensor was synthesized by two step reaction. The chemosensor showed that high selectivity toward fluoride in DMSO. The fluorescence intensity was drastically increased by binding between chemosensor and fluoride ion. Absorption and fluorescence spectra were obtained by UV-Vis spectrometer and fluorescence spectrophotometer. The binding ratio between chemosensor and fluoride ion was also investigated by job's plot method and Benesi-Hildebrand plot. The HOMO/LUMO energy levels and electron distribution were calculated and simulated by Material studio 6.0 Package.

Phantom에서 Laser Induced Fluorescence의 스펙트라에 관한 연구 (A Study on Spectra of Laser Induced Fluorescence in Phantom)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.329-335
    • /
    • 1999
  • The influences of fluorophor, scatterer, and absorber in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength. The molecular properties have been studied by laser induced fluorescence spectroscopy in phantom. It has been found that the effects of optical properties in scattering media could be investigated by the optical parameters(${\mu}_a$, ${\mu}_a$, ${\mu}_t$). Experimental and Monte Carlo Simulation method for modelling light transport in tissue was applied. The experimental results using a phantom were discussed and compared with those obtained through Monte Carlo Simulation. It may also aid in designing the best model for oil chemistry, medicine and application of medical engineering.

Spray Structures and Vaporizing Characteristics of a GDI Fuel Spray

  • Park, Dong-Seok;Park, Gyung-Min;Kim, Duck-Jool
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.999-1008
    • /
    • 2002
  • The spray structures and distribution characteristics of liquid and vapor phases in non-evaporating and evaporating Gasoline Direct Injection (GDI) fuel sprays were investigated using Laser Induced Exciplex Fluorescence (LIEF) technique. Dopants were 2% fluorobenzene and 9% DEMA (diethyl-methyl-amine) in 89% solution of hexane by volume. In order to study internal structure of the spray, droplet size and velocity under non-evaporating condition were measured by Phase Doppler Anemometry (PDA). Liquid and vapor phases were visualized at different moments after the start of injection. Experimental results showed that the spray could be divided into two regions by the fluorescence intensity of liquid phase: cone and mixing regions. Moreover, vortex flow of vapor phase was found in the mixing region. About 5㎛ diameter droplets were mostly distributed in the vortex flow region. Higher concentration of vapor phase due to vaporization of these droplets was distributed in this region. Particularly, higher concentration of vapor phase and lower one were balanced within the measurement area at 2ms after the start of injection.

Development of Liposome Immunoassay for Salmonella spp. using Immunomagnetic Separation and Immunoliposome

  • Shin, Jung-Hee;Kim, Myung-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권10호
    • /
    • pp.1689-1694
    • /
    • 2008
  • The ability to detect Salmonella spp. is essential in the prevention of foodborne illness. This study examined a Salmonella spp. detection method involving the application of immunomagnetic separation and immunoliposomes (IMS/IL) encapsulating sulforhodamine B (SRB), a fluorescent dye. A quantitative assay was conducted by measuring the fluorescence intensity of SRB that was produced from an immunomagnetic bead-Salmonella spp.-immunoliposome complex. The results indicated detection limits of $2.7{\times}10^{5}$ and $5.2{\times}10^{3}$ CFU/ml for Salmonella enterica subsp. enterica serovar Enteritidis (S. Enteritidis) and Salmonella enterka subsp. enterka serovar Typhimurium (S. Typhimurium), respectivley. The signal/noise ratio was improved by using 4% skim milk as a wash solution rather than 2% BSA. In addition, higher fluorescence intensity was obtained by increasing the liposome size. Compared with the conventional plating method, which takes 3-4 days for the isolation and identification of Salmonella spp., the total assay time of to h only including 6 h of culture enrichment was necessary for the Salmonella detection by IMS/IL. These results indicate that the IMS/ IL has great potential as an alternative rapid method for Salmonella detection.