• 제목/요약/키워드: Fluorescence detection system

검색결과 133건 처리시간 0.022초

수질내 초미립자와 미생물의 동시 검출을 위한 광학센서기술 (Optical sensing techniques for simultaneous detection of nanoparticles and microorganisms in water)

  • 손옥재;형기우;김병섭;이종일
    • 센서학회지
    • /
    • 제17권3호
    • /
    • pp.157-161
    • /
    • 2008
  • An optical sensor was developed to detect nanoparticles, turbid materials and microorganisms in water simultaneously. Three different light sources like UV-LED, NIR-LED and laser diode have been employed to develop the optical sensor based on the scattering light and fluorescence light. The sensor system has high selectivity and sensitivity, that it can be used to monitor the quality of drinking water.

Development of a high-performance liquid chromatographic method for the determintion of levosulpiride in plasma

  • Ban, Eun-Mi;Jang, Dong-Jin;Kim, Adele;Park, Jeong-Sook;Kim, Chong-Kook
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.400.3-401
    • /
    • 2002
  • Levosulpiride is the levo-enantiomer from of racemic sulpride. abenzamide derivative selectively inhibition doparninergic D2 receptos at the trigger zone both in the central nervous system and in the gastrointestinal tract. We report a rapid and sensitive HPLC method using reverse phase C 18 column with fluorescence detection for separation and quantitation of levosulpiride in plasma. Tiapride was used as an internal standard. After adding an internal standard. levosulpiride in 800 ${\mu}l$ of plasma was extracted under basic conditions with ethyl acetate and methylene chloride. (omitted)

  • PDF

광 다이오드를 가진 Microfluidic LOC 시스템 제작 (fabrication of the Microfluidic LOC System with Photodiode)

  • 김현기;신경식;김용국;이상렬;김태송;양은경;주병권
    • 한국전기전자재료학회논문지
    • /
    • 제16권12호
    • /
    • pp.1097-1102
    • /
    • 2003
  • In this paper, we used only PR as etching mask, while it used usually Cr/AU as etching mask, and in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. we designed microchannel size width max 10um, min 5um depth max 10um, reservoir size max 100um, min 2mm. Fabrication of microfluidic devices in glass substrate by glass wet etching methods and glass to glass fusion bonding. The p-i-n diode has higher sensitivity than photodiode, Considering these results, we fabricated p-i-n diodes on the high resistive(4㏀$.$cm) wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of pin diode can be decreased by the application of finger pattern has parallel resistance structure from 571Ω to 393Ω.

Production and Degradation of Cyanobacterial Toxin in Water Reservoir, Lake Soyang

  • Pyo, Dong-Jin;Jin, Jung-Eun
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권5호
    • /
    • pp.800-804
    • /
    • 2007
  • Cyanobacterial toxins, microcystins are very potent hepatotoxins and their occurrence has been reported all over the world. They could threaten human health when toxic Microcystis occurs in water supply reservoirs. In this study, the effects of several environmental factors on production and degradation of toxins produced by cyanobacteria in Lake Soyang have been studied. A new rapid quantification method of microcystins using fluorescence for a detection signal and a lateral-flow-type immunochromatography as a separation system was used. Culture age, temperature, light intensity, pH, N-nutrient concentration, P-nutrient concentration, iron and zinc concentration were the most importantly examined factors. The toxin content was the highest on 17-18 days and at temperatures between 20℃ and 25℃, and at pH between 8.4 and 8.8.

초소형 미세형광측정 스캐닝 시스템 (Miniature Fluorescence Detection System for Protein Chip)

  • 김용윤;성천야;김호성;이국녕;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.254-256
    • /
    • 2002
  • 광섬유, 마이크로렌즈, 마이크로 프리즘, 마이크로 스캐너로 구성된 단백질 분석용 초소형 형광측정 시스템을 설계하였다. SNR을 높이기 위해 단백질 패턴에 여기광이 수직이 아닌 비스듬하게 입사하는 구조를 제안하였으며 그 가능성을 실험적으로 확인하였다.

  • PDF

펄스 레이저 기반 담수용 미세 플라스틱 실시간 센서 모니터링 시스템 연구 (Study on Real Time Sensor Monitoring Systems Based on Pulsed Laser for Microplastic Detection in Tap Water)

  • 한승헌;김대근;정행윤;김선훈
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.294-298
    • /
    • 2019
  • Pulsed laser-based optical sensor monitoring systems for real time microplastic particle counting are proposed and developed in this study. To develop our real time monitoring system, we used a 450 nm pulsed laser and a photomultiplier with very high quantum efficiency. First, we demonstrated that the microplastic particle counting system could detect standard micro bead samples of 100, 250, and $500{\mu}m$ in river water. We then performed research concerning pulsed laser-based optical spectral sensor systems for real time microplastic monitoring. Additionally, we demonstrated that the real time microplastic remote monitoring system using LoRa communications could detect microplastic in the tap water resource protection area.

Detection of transgene in early developmental stage by GFP monitoring enhances the efficiency of genetic transformation of pepper

  • Jung, Min;Shin, Sun-Hee;Park, Jeong-Mi;Lee, Sung-Nam;Lee, Mi-Yeon;Ryu, Ki-Hyun;Paek, Kee-Yoeup;Harn, Chee-Hark
    • Plant Biotechnology Reports
    • /
    • 제5권2호
    • /
    • pp.157-167
    • /
    • 2011
  • In order to establish a reliable and highly efficient method for genetic transformation of pepper, a monitoring system featuring GFP (green fluorescent protein) as a report marker was applied to Agrobacteriummediated transformation. A callus-induced transformation (CIT) system was used to transform the GFP gene. GFP expression was observed in all tissues of $T_0$, $T_1$ and $T_2$ peppers, constituting the first instance in which the whole pepper plant has exhibited GFP fluorescence. A total of 38 T0 peppers were obtained from 4,200 explants. The transformation rate ranged from 0.47 to 1.83% depending on the genotype, which was higher than that obtained by CIT without the GFP monitoring system. This technique could enhance selection power by monitoring GFP expression at the early stage of callus in vitro. The detection of GFP expression in the callus led to successful identification of the shoot that contained the transgene. Thus, this technique saved lots of time and money for conducting the genetic transformation process of pepper. In addition, a co-transformation technique was applied to the target transgene, CaCS (encoding capsaicinoid synthetase of Capsicum) along with GFP. Paprika varieties were transformed by the CaCS::GFP construct, and GFP expression in callus tissues of paprika was monitored to select the right transformant.

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제1권4호
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

Prospective Multicenter Feasibility Study of Laparoscopic Sentinel Basin Dissection after Endoscopic Submucosal Dissection for Early Gastric Cancer: SENORITA 2 Trial Protocol

  • Eom, Bang Wool;Yoon, Hong Man;Min, Jae Seok;Cho, In;Park, Ji-Ho;Jung, Mi Ran;Hur, Hoon;Kim, Young-Woo;Park, Young Kyu;Nam, Byung-Ho;Ryu, Keun Won;Sentinel Node Oriented Tailored Approach (SENORITA) Study Group
    • Journal of Gastric Cancer
    • /
    • 제19권2호
    • /
    • pp.157-164
    • /
    • 2019
  • Purpose: Although standard radical gastrectomy is recommended after noncurative resection of endoscopic submucosal dissection (ESD) for early gastric cancer in most cases, residual tumor and lymph node metastasis have not been identified after surgery. The aim of this study is to evaluate the feasibility of sentinel node navigation surgery after noncurative ESD. Materials and Methods: This trial is an investigator-initiated, multicenter prospective phase II trial. Patients who underwent ESD for clinical stage T1N0M0 gastric cancer with noncurative resections were eligible. Qualified investigators who completed the prior phase III trial (SENORITA 1) are exclusively allowed to participate. In this study, 2 detection methods will be used: 1) intraoperative endoscopic submucosal injection of dual tracer, including radioisotope and indocyanine green (ICG) with sentinel basins detected using gamma-probe; 2) endoscopic injection of ICG, with sentinel basins detected using a fluorescence imaging system. Standard laparoscopic gastrectomy with lymphadenectomy will be performed. Sample size is calculated based on the inferior confidence interval of the detection rate of 95%, and the calculated accrual is 237 patients. The primary endpoint is detection rate, and the secondary endpoints are sensitivity and postoperative complications. Conclusions: This study is expected to clarify the feasibility of laparoscopic sentinel basin dissection after noncurative ESD. If the feasibility is demonstrated, a multicenter phase III trial will be initiated to compare laparoscopic sentinel node navigation surgery versus laparoscopic standard gastrectomy in early gastric cancer after endoscopic resection.

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권6호
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.