• Title/Summary/Keyword: Fluorescence Lamp

Search Result 64, Processing Time 0.027 seconds

유기형광법을 이용한 피스톤 유막두께의 이차원적 측정 (Measurement of two dimensional oil film thickness in piston by induced fluorescence method)

  • 민병순;최재권
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.166-174
    • /
    • 1998
  • The distribution of oil film thickness in piston were measured by induced fluorescence method. A Xe lamp was used as light source. Coumarine-6 was mixed with oil as the fluorescent dye. Fluorescent signal which is proportional to the oil film thickness was acquired by CCD camera and transmitted to the personal computer as video signal. In order to solve the problem of measurement system, irregular distribution and unstability of light intensity, as well as to know the relationship between the oil film thickness and output signal, three different calibration techniques were used. Motoring and firing tests were performed in a single cylinder research engine with transparent liner. By analyzing the oil film thickness converted from the photographed image, it was observed that each of three piston rings scrapes the oil both upward and downward and oil film thickness is not uniform horizontally at a given piston land. The amount of oil in each land was considerably affected by the engine load. It is thought that the blow-by gas blows the oil down to the crankcase.

  • PDF

Preconcentration and Detection of Herbicides in Water by Using the On-line SPE-HPLC System and Photochemical Reaction

  • 이승호;이성광;박영훈;김현주;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권10호
    • /
    • pp.1165-1171
    • /
    • 1999
  • The analysis of trace herbicides using the on-line SPE-HPLC system and a photochemical reaction was studied. 18 compounds of herbicides including eight triazines, six phenoxy acids and esters, and four other herbicides were examined. The on-line SPE-HPLC system developed for selection of eluting solvent improved chromatographic efficiency. The recoveries of herbicides were higher than 77%. With 100 mL tap water samples, the detection limits for all analytes were in the 0.1-2.3×10-10 M range. Detection was done by a UV or fluorescence spectrometer after photochemical reaction at the end of the column with 2W or 450W mercury lamp. Without a photochemical reaction, all compounds responded to 230 nm UV detector, but phenoxy acids and esters were weakly detected. However, with a photochemical reaction, these compounds were selectively detected at 320 nm wavelength of UV absorption and 400 nm emission of the fluorescence detectors. This method can be used for the analysis of environmental water containing herbicides at trace levels.

110W용 T5 형광 램프용 전자식 안정기 개발 (Development of Electronic Ballast for 110W T5 Fluorescence Lamp)

  • 이진우;최현배;박재권
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.183-184
    • /
    • 2004
  • 비교적 최근에 개발된 T5 형광 램프를 점등시키기 위한 전자식 안정기를 개발하였다. 램프는 110W의 정격을 갖고, 그 길이는 2300mm이다. 제작한 안정기는 우수한 기동특성을 보였으며 안정된 전기적, 광학적 특성을 얻을 수 있었다.

  • PDF

330W용 UV 램프용 전자식 안정기 개발 (Development of Electronic Ballast for 110W T5 Fluorescence Lamp)

  • 이진우;최현배;박재권
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.185-186
    • /
    • 2004
  • UV 램프 시스템은 산업, 환경분야에서 폭넓게 사용되고 있으며, 램프의 용량이 커지는 추세를 보이고 있다. 이에 본 연구에서는 출력이 보다 안정화되고, 대용량에 적합한 고효율 UV램프 구동시스템을 개발하였다.

  • PDF

멸구과 8종의 ITS2 DNA 염기서열 비교 분석과 고리매개등온증폭법(LAMP)을 이용한 벼멸구 특이 진단법 (ITS2 DNA Sequence Analysis for Eight Species of Delphacid Planthoppers and a Loop-mediated Isothermal Amplification Method for the Brown Planthopper-specific Detection)

  • 서보윤;박창규;고영호;정진교;조점래;강찬영
    • 한국응용곤충학회지
    • /
    • 제56권4호
    • /
    • pp.377-385
    • /
    • 2017
  • 멸구과(Delphacidae) 8종의 internal transcribed spacer 2 (ITS2) DNA 염기서열로 종간 차이 추정값을 비교하고 분자계통수를 추론하였다. ITS2 DNA 염기서열 길이는 종(species)마다 550 bp (흰등멸구)에서 699 bp (겨풀멸구)까지 차이를 보였다. 같은 Nilaparvata 속의 겨풀멸구와 벼멸구붙이 사이의 염기서열 차이 추정값($d{\pm}S.E.$)은 $0.001{\pm}0.001$로 가장 낮았으며, 사슴멸구와 일본멸구 사이는 $0.579{\pm}0.021$로 가장 높았다. 벼멸구와 다른 멸구류들과의 종간 염기서열 차이 추정값은 $0.056{\pm}0.008$ (겨풀멸구)에서부터 $0.548{\pm}0.021$ (일본멸구)로 구분되었다. 반면, Neighbor-joining 방법으로 추론된 분자계통수에서는 겨풀멸구와 벼멸구붙이를 제외하고 나머지 멸구류들은 독립된 다른 그룹으로 분지되었다. 벼멸구의 ITS2 염기서열을 참고하여 벼멸구 특이 고리매개등온증폭(loop-mediated isothermal amplification, LAMP) 프라이머 4 세트(BPH-38, BPH-38-1, BPH-207 및 BPH-92)를 제작하였다. 이들 각각을 벼멸구, 흰등멸구 및 애멸구의 게놈 DNA와 $65^{\circ}C$에서 60분간 반응시켰을 때, 벼멸구 시료에서만 증폭 산물들이 관찰되었다. BPH-92 LAMP 프라이머 세트로 $65^{\circ}C$에서 벼멸구 DNA의 양(0.1 ng, 1 ng, 10 ng, 100 ng)과 반응시간(20분, 30분, 40분, 60분)을 달리하여 형광반응을 관찰하였을 때, 20분과 30분 반응에서는 100 ng 까지에서도 발광여부 구별이 어려웠다. 그러나 40분 반응에서는 10 ng 이상에서, 60분 반응에서는 0.1 ng 이상에서 발광여부가 명확히 구별되었다.

한국인 피부의 자외선 감수성과 SPF 측정치에 미치는 인자의 영향 (UV Sensitivity of Korean Skin and The Effects of Factors affecting SPF Determination)

  • 이병곤
    • 대한화장품학회지
    • /
    • 제17권1호
    • /
    • pp.1-17
    • /
    • 1991
  • Multiport-600 Solar SimulatorR is one of the most recent and convenient in-strument for evaluation of sun protection factor(SPF). In this study, we examined the practicability of the SPF determining system using Multiport -600 and the effects of several factors-light sources, seasons and experimental animals-on the minimal erythema dose(MED) and SPF. We also tested the UV sensitivity according to the sites of Korean people, And the ultraviolet radiation reaching the earth's surface In Seoul have been observed for one year. As a result of this study, the determinig system for SPF using Multiport-600 was proved to be a good system in accuracy and time-saving. The biological activity of fluorescence UV lamp of PUVA-800R was significantly higher than natural light or solar simulator with Xe arc lamp, and the determined MED became lower in inverse proportion to room temperature rise. Skin sensitivity by ultraviolet adiation was hights. in order \circled1 back \circled2 inns, upper arm \circled3 outer upper arm \circled4 foream. We also observed that UV radiation intensity was highest at noon in july and 1 sun burn unit(MED) was 28 minutes at that time.

  • PDF

자외선 램프로 식별 가능한 안료코팅용지 개발 (Development of Pigment Coated Paper Recognizable With UV Light)

  • 김선경;조병욱;이용규
    • 펄프종이기술
    • /
    • 제43권4호
    • /
    • pp.76-81
    • /
    • 2011
  • This study was carried out in order to develop a speciality functional coated paper, which can be recognized under a ultraviolet lamp. The special fluorescent whitening agent (FWA) which absorbs ultraviolet light (397~410 nm) and emits it as yellowish light (570~500nm) was used. The special FWA was applied in a coating color in two ways: (1) direct application to a coating color as a FWA; (2) application on pigment surface, drying it and application it as a fluorescence whitening pigments (colored pigments). The effects of the special FWA on coating color properties were tested and the distribution of colored pigments in coated paper was evaluated under a ultraviolet lamp. The results showed that the colored pigments didn't affect on coating color properties. Experimental results showed the possibility of producing a security coated paper using the special FWA. To produce a speciality functional paper, it was found to be proper to apply the special FWA in the form of colored pigment.

형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석 (Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter)

  • 오상우;서동민;안기영;김재우;이문진;전태병;서성규
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권4호
    • /
    • pp.304-309
    • /
    • 2015
  • 해양에서 기름 유출 사고로 인한 오염도를 정량적으로 평가하기 위해서, 사고 현장에서 기름을 직접 탐지할 수 있는 센서의 적용이 필요하다. 여러 형태의 기름 탐지 센서 중에서, 기름 성분에 의한 형광 현상(fluorescence)을 탐지 원리로 하는 센서는 해수 중에 존재하는 기름의 농도를 측정할 수 있으므로 효용성이 높은 장점을 갖고 있다. 그러나 이런 종류의 센서는 기름의 형광 현상을 야기시키기 위해서, 수은 램프(mercury lamp)와 같은 자외선 광원(ultraviolet light source)이 필요하고 다양한 종류의 광학 필터와 광전증배관(photomultiplier tube, PMT)과 같은 광학 센서가 주로 사용된다. 이러한 이유로 형광 측정을 기반으로 하고 있는 센서는 측정 플랫폼의 크기가 크기 때문에 현장에서 원활히 사용하기에 한계가 있으며, 고가의 부품들이 집적되어 있어, 센서의 가격이 높은 단점을 갖고 있다. 이러한 단점을 극복하기 위해서, 본 논문에서는 소형의 크기와 가격 경쟁력을 갖고 있는 형광 광도계 기반의 기름 탐지 센서를 설계하는 방법에 대해서 제시하였다. 형광 광도계의 설계 인자를 파악하기 위한 방법으로, 본 연구에서는 5종의 원유 샘플과 3종의 정제유를 이용하여, 기름의 여기 스펙트럼(excitation spectrum)과 발광 스펙트럼(emission spectrum)을 측정하였다. 여기 스펙트럼과 발광 스펙트럼의 측정을 위해서는 형광 분광기(fluorescence spectrometer)를 이용하였고, 측정된 스펙트럼 자료를 분석하여 형광 광도계(fluorimeter) 설계에 필요한 유종에 따른 공통 스펙트럼 파장 대역을 도출하였다. 본 실험을 통해서 모든 종류의 기름 샘플의 경우, 여기 스펙트럼과 발광 스펙트럼의 최고 값을 갖는 파장의 차이는 약 50 nm인 것으로 파악되었다. 실험 중에서, 여기광의 파장을 365 nm와 405 nm로 고정하였을 경우, 280 nm와 325 nm로 고정하였을 경우에 비해서 최대 발광(emission)의 세기가 작아지는 것을 확인할 수 있었다. 따라서 형광 광도계의 광원 파장을 365 nm 또는 405 nm로 사용할 경우, 광학 센서의 민감도(sensitivity)가 발광되는 빛의 세기를 측정할 수 있도록 설계에 반영해야 할 것으로 판단된다. 본 연구의 실험에서 도출된 결과를 통해서, 기름 탐지를 위한 형광 광도계의 광원, 광학 센서 그리고 광학 필터의 유효 파장 대역을 선택하는데 필요한 설계 인자를 파악할 수 있었다.

콩의 광질에 대한 엽 색소 및 엽록소 형광반응 연구 (Response of Leaf Pigment and Chlorophyll Fluorescence to Light Quality in Soybean (Glycine max Merr. var Seoritae))

  • 박세준;김도연;유성녕;김현희;고태석;심명룡;박소현;양지아;엄기철;홍선희;김태완
    • 한국토양비료학회지
    • /
    • 제43권3호
    • /
    • pp.400-406
    • /
    • 2010
  • 서리태콩 (Glycine max Merr. var Seoritae)에서 광원에 따른 엽의 광합성 변화를 구명하기 위하여 콩의 제 1복엽이 완전 전개되었을 때 3일 동안 빛을 차단한 후 UV-B 와 일반광에 노출시켜 색소 함량과 엽록소 형광반응의 변화를 측정하였다. 암처리에서 엽록소 함량은 감소하고, 일반 광에서 회복하였다. 카로티노이드와 안토시아닌 함량은 UV-B 조사한 처리구에서 증가하였다. 엽록소 형광분석을 이용한 광합성 능률을 분석한 결과, 암처리가 진행 됨에 따라 Fv/Fm, F'v/F'm, ${\Phi}_{PSII}$ 및 NPQ는 감소하였다. 모든 변수들은 일반광에 노출되면서 회복하였으나 UV 처리한 것은 암처리 72시간의 수치와 큰 변화가 없었다. 이를 통하여 암처리 48시간 경과함으로 엽록체가 에티오플라스트로 전환되며, 일반광을 조사하였을 시 광합성 관련 광계가 복구되지만, UV-B의 강한 광이 조사되었을 때 광계가 회복되지 못하는 것으로 사료되었다.

고리매개등온증폭법(LAMP)을 이용한 흰등멸구 특이 판별법 (A Loop-mediated Isothermal Amplification Method for White-backed Planthopper-specific Detection)

  • 서보윤;박창규;정진교;조점래;이관석;김광호
    • 한국응용곤충학회지
    • /
    • 제57권4호
    • /
    • pp.393-399
    • /
    • 2018
  • 고리매개등온증폭법(LAMP)으로 흰등멸구를 특이적으로 구별해낼 수 있는 프라이머 세트(WBPH-65)가 핵내 ITS2영역의 전체염기서열(KC417469.1)을 바탕으로 설계 제작되었다. WBPH-65는 총 6개의 프라이머, F3 (18 bp), B3 (18 bp), FIP (43 bp), BIP (40 bp), LF (21 bp), LB (25 bp)로 구성되는데, 전체 합한 길이가 165 bp이다. WBPH-65를 흰등멸구, 벼멸구 및 애멸구의 게놈 DNA와 $65^{\circ}C$에서 60분간 고리매개등온증폭 반응시켰을 때, 흰등멸구 시료에서만 증폭 산물들이 관찰되었다. $65^{\circ}C$에서 WBPH-65와 흰등멸구 게놈 DNA의 양과 반응시간을 달리하여 형광반응을 관찰하였을 때 40분 반응에서는 10과 100 ng DNA에서, 60분 반응에서는 0.01, 0.1, 1, 10, 100 ng DNA에서 발광여부가 명확히 구별되었다. 그러나 20분과 30분 반응에서는 준비된 모든 DNA 양에서 발광여부 구별이 어려웠다. 한편, WBPH-65에서 LF와 BF 프라이머를 뺀 경우 60분 반응에서는 벼멸구, 애멸구 뿐만 아니라 흰등멸구의 게놈 DNA에서도 발광되지 않았다. 본 연구 결과로부터 WBPH-65가 60분 이내 반응에서 흰등멸구를 특이적으로 구별하기 위해서는 6개의 프라이머가 모두 필요하며 최소한 벼멸구와 애멸구를 구별해낼 수 있음을 확인하였다.