• 제목/요약/키워드: Fluorescence Intensity

검색결과 575건 처리시간 0.062초

Fluorescence Intensity Changes for Anthrylazacrown Ethers by Paramagnetic Metal Cations

  • 장정호;김해중;박중희;신영국;정용석
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권7호
    • /
    • pp.796-800
    • /
    • 1999
  • Three anthrylazacrown ethers in which the anthracene fluorophore π system is separated from the electron donor atoms by one methylene group were synthesized, and their photophysical study was accomplished. These fluorescent compounds showed a maximum fluorescence intensity at pH=5 in aqueous solutions and a decrease in fluorescence intensity upon binding of paramagnetic metal cations (Mn 2+ (d 5 ), Co 2+ (d 7 ), Cu 2+ (d 9 )). The decrease in fluorescence intensity may be attributed to the paramagnetic effect of metal cations to deactivate the excited state by the nonradiative quenching process. The benzylic nitrogen was found to play an important role in changing fluorescence intensity. From the observed linear Stern-Volmer plot and the fluorescence lifetime independence of the presence of metal ions, it was inferred that the chelation enhanced fluorescence quenching (CHEQ) mechanism in the system is a ground state static quenching process. Enhanced fluorescence was also observed when an excess Na + ion was added to the quenched aqueous solution, and it was attributed to cation displacement of a complexed fluorescence quencher.

복합 광원을 갖는 형광 내시경 개발 (Development of the Fluorescence Endoscope System with Dual Light Source Apparatus)

  • 배수진;강욱
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.222-226
    • /
    • 2007
  • We suggest the fluorescence endoscope system that has light source apparatus providing selectable white or excitation light. White light source generates normal color images and is easily switched over to excitation light with the wide spectrum range from 380 nm to 580 nm. 5-ALA is deposited selectively in the abnormal tissue like cancer and causes fluorescence in the red spectrum range when excited by blue spectrum range. In addition, the others of excitation light make the color background image by reflected light to allow accurate orientation and visualization of the abnormal tissue and around. According to clinical studies, the fluorescence intensity contrast that defines the fluorescence intensity of lesion over the fluorescence intensity of around has more than 2 in tumour. Proposed system is useful and objective way in early diagnosis. Furthermore, it can be used in the biopsy for tumour classification at the highest fluorescence intensity point.

Effects of surfactants on the Fluorescence of Beryllium-Morin Complex

  • Kim, Kang-Jin;Kim, Bok-Hee;Lee, Beom-Gyu;Park, Joon-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • 제9권2호
    • /
    • pp.106-108
    • /
    • 1988
  • The effects of surfactants, CTAB, SDS, and TX-100, on the fluorescence emission intensity of Be-morin complex was studied in terms of pH, temperature, added electrolyte, and concentration of surfactants. The ionic surfactants decreased the fluorescence intensity of the complex. However, the addition of TX-100 caused a substantial increase in the fluorescence intensity without spectral shift, by which means the detection limit of Be was obtained to be 0.3 ppb. Optimum pH for Be determination was near 9.6 and the fluorescence intensity showed a continuous decline with the increase of temperature. Nitrate ion lowered the fluorescence intensity considerably. Mechanism of the interference remains to be elucidated.

Changes in Hydrophobic Surface of Collagen by Chondroitin Sulfate : Fluorescence Intensity Measurements with Bis-ANS as the Probe

  • Kim, Sung-Koo
    • 한국식품영양과학회지
    • /
    • 제24권3호
    • /
    • pp.446-453
    • /
    • 1995
  • The improtant components of extracellular matrix(ECM) are collagen and chondroitin sulfate. The hydrophobic surface of collagen is one of the determining factors of diameter of collagen fiber and also is closely related to the aging phenomena. The controlling mechanism of the diameter of collagen fiber influenced by the interaction with chondroitin sulfate was evaluated using bis-ANS as a hydrophobic probe. Hydrophobic surface area of collagen molecule shielded by chondroitin sulfate was evaluated. Relative fluorescence intensity of collagen in thepresence of chondroitin sulfate was measured using bis-ANS as a hydrophobic probe. The fluorescence intensity decreased with the increase in chondroitin sulfate up to 3.8 chondroitin sulfate/collagen(mole/mole). Further increase in the ratio of chondroitin sulfate to collagen did not change the fluorescence intensity. Similar changes in the relative fluorescence intensity were observed for both rat tail and lathyrific rat skin collagen. The fluorescence intensity indicated by the binding between bis-ANS and hydrophobic sites of collagen was pH dependent, and the shielding effect of collagen-chondroitin sulfate interaction could not be detected at pH above 6.0. This is probably due to the charge repulsions caused by negative charged collagen molecules at higher pH.

  • PDF

Excimer 형광법을 이용한 연료증기 농도측정법에 대한 연구 (Measurement of Fuel Vapor Concentration by Excimer Fluorescence Method)

  • 황승민
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.437-445
    • /
    • 2018
  • Laser induced-exciplex-fluorescence (EXCIPLEX) proposed by Melton is used to visualize fuel vapor in spray combustion. However, in the EXCIPLEX method based on TMPD/naphthalene system, the TMPD : naphthalene ratio is strictly restricted to 1 : 9. In addition, fluorescence intensity due to the vapor phase is extremely weak. To overcome these drawbacks, we propose a new laser-induced-excimer fluorescence (EXCIMER) method to visualize the liquid and vapor phases simultaneously. The spatial distributions of liquid and vapor in fuel spray suspended by ultrasonic waves are compared using the EXCIPLEX and EXCIMER methods. The correlation between fuel vapor concentration and fluorescence intensity is experimentally investigated by measuring the fluorescence intensity of saturated vapor formed over liquid fuel at a controlled temperature. These experimental results indicate that the EXCIMER method is effective for evaluating fuel vapor visualization in spray combustion. Furthermore, the quantitative distribution of fuel vapor concentration can be correctly estimated by the EXCIMER method.

Kinetics of Cl Atom Reactions. Anomaluous Fluorescence Behavior of Some Cl Atomic Transitions

  • Kwang-Yul Choo
    • Bulletin of the Korean Chemical Society
    • /
    • 제1권1호
    • /
    • pp.1-4
    • /
    • 1980
  • During the study of the kinetics of Cl atom reactions by atomic fluorescence method we observed anomalous fluorescence emission for some atomic transitions. Instead of usual decrease of the fluorescence intensity by adding substrate, 1363 A transition $(^2P^{\circ}_{3/2}{\to}^2P_{1/2})$ intensity increased by adding substrate. From the normally behaved fluorescence lines the absolute rate constant for the reaction, Cl + $CH_3Cl{\to}$, was found to be $4.2{\times}10^{-13}$ cc/molecule sec at $20^{\circ}C$.

반다공성 재질에 유류된 지문의 CA 훈증 후 p-dimethylaminobenzealdehyde(DMAB) 형광시약 적용 시 표면적과 주변 온도, 기압이 형광착색에 미치는 효과에 관한 연구 (Enhancement of cyanoacrylate-developed marks using p-dimethylaminobenzaldehyde (DMAB) on semi-porous surfaces and analysis of the influence factors on fluorescence intensity)

  • 유제설;김주하
    • 분석과학
    • /
    • 제27권4호
    • /
    • pp.187-195
    • /
    • 2014
  • 잠재지문이 유류된 배경과 지문과의 대조비를 높이기 위한 증강작업 시에 잠재지문의 훼손을 최소화하는 것은 매우 중요하다. 본 실험은 반다공성 표면에 유류된 잠재지문을 시아노아크릴레이트 훈증 처리 후 p-dimethylaminobenzealdehyde (DMAB) 증강시약을 사용하여 그 효과를 확인하고, 증강효과에 미치는 환경적 요인을 분석한 것이다. 실험에 사용된 모든 지문은 시아노아크릴레이트 진공 훈증 후 실온에서 24 시간 건조해 사용하였다. 시아노아크릴레이트 훈증물의 DMAB 형광염색을 위해 표면적, 온도, 기압을 달리한 조건에서 12 시간 단위로 48 시간 동안 승화시켰다. 표면적 영향에 대한 실험에서 물질의 입자크기와 용기의 크기는 DMAB의 승화속도와 형광세기에 영향을 주었다. 또한 무용매접촉법을 적용한 DMAB 형광염색은 36 시간 승화 후 최대 형광세기를 보였고, 일정 표면적 이상에서는 형광세기에 미치는 영향이 저조하였다. 온도에 관한 실험에서 DMAB는 $20^{\circ}C$의 실온에서 가장 잘 승화하였고, 최대형광 세기를 얻을 수 있는 승화시간이 48 시간에서 36 시간으로 단축되었다. 또한 $30^{\circ}C$이상의 상온에서는 오히려 적정 형광세기를 나타내는 승화시간이 길어지고, 형광세기에 미치는 영향도 미약했다. 또한 압력에 관한 실험에서는 압력의 변화가 매우 크지 않는 이상 형광세기가 비진공상태에서의 형광세기보다 약했다.

Fluorescence Quenching of Green Fluorescent Protein during Denaturation by Guanidine

  • Jung, Ki-Chul;Park, Jae-Bok;Maeng, Pil-Jae;Kim, Hack-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권3호
    • /
    • pp.413-417
    • /
    • 2005
  • Fluorescence of green fluorescent protein mutant, 2-5 GFP is observed during denaturation by guanidine. The fluorescence intensity decreases exponentially but the fluorescence lifetime does not change during denaturation. The fluorescence lifetime of the denatured protein is shorter than that of native form. As the protein structure is modified by guanidine, solvent water molecules penetrate into the protein barrel and protonate the chromophore to quench fluorescence. Most fluorescence quenchers do not affect the fluorescence of native form but accelerate the fluorescence intensity decay during denaturation. Based on the observations, a simple model is suggested for the structural change of the protein molecule during denaturation.

형광 나노 포러스 박막을 이용한 표면 온도 센서의 제작 및 성능 연구 I (Fabrication and Performance Investigation of Surface Temperature Sensor Using Fluorescent Nanoporous Thin Film I)

  • 김현정;유재석;박진일
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.668-673
    • /
    • 2013
  • In this study, specimens with nano-sized porous thin films were manufactured by injecting fluorescence solution into the pores. We intended to find out the difference of the fluorescence intensity in each region of the specimen through an experimental apparatus that makes a temperature field. Before conducting experiments, the optimized manufacturing conditions were determined by analysis of all parameters that influence the emission intensity, and the experiments were carried out with the specimens produced in the optimized conditions. Then, the calibration curves of the fluorescence intensity versus temperature were performed by taking the intensity distributions from the specimen in various temperature fields. The surfaces of specimens were coated with Rhodamine-B (Rh-B) fluorescent dye and measured based on the fluorescence intensity. Silica (SiO2) nanoporous structure with 1-um thickness was constructed on a cover glass, and fluorescence dye was absorbed into these porous thin films.

The Fluorescent Effects on the N-Substituents of Polyarylenevinylenes Having 1,2-Diphenylmaleimide Moieties

  • Lee, Jun-Kyu;Yang, Nam-Choul;Park, Ho-Wook;Suh, Dong-Hack
    • Macromolecular Research
    • /
    • 제11권2호
    • /
    • pp.92-97
    • /
    • 2003
  • Model compounds and polymers having N-substituted 1,2-diphenylmaleimide moieties were synthesized and characterized by NMR, IR, UV, and fluorescence spectroscopy. The fluorescence intensity could be controlled by N-substituents of model compounds and polymers. As the structure of an N-substituent of them was bulkier, or the electron density of an N-substituent was denser, the photoluminescence intensity was increased. All the compounds showed greenish yellow photoluminescence with the maximum intensity between 510 and 537 nm. From quantum efficiency data of the model compounds and the polymers, the fluorescence intensity of the polymer 11 was higher than that of the model compound 4.