• 제목/요약/키워드: Fluids visualization

검색결과 117건 처리시간 0.023초

ER유체의 클러스터 형성 메커니즘에 관한 연구 (A Study on the Mechanism of Clusters Formation of ER Fluids)

  • 이은준;박명관
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.503-506
    • /
    • 2002
  • Electrorheological fluids(ERFs) show a rapid and reversible increase in viscosity by applied electric field. It is called the electrorheological effect (ER effect). The reason for ER effect is the induction of an electric dipole in each particle, leading to the formation of clusters in the direction of the field, which resist fluid flow. Generally, the behavior of ER fluids has been modeled on those of Bingham fluids. But there are some differences between Bingham fluids and ER fluids. The visualization of ER fliuds are presented and ER effects by the forming, growing and breaking of clusters are discussed. In the low shear rate area, the pressure drop is measured by a pressure sensor and the formation of ER particles is visualized by video camera. The reason for the nonlinear behavior of ER fluids at low shear rate is explained through results of visualization.

  • PDF

가시화를 통한 ER유체의 클러스터 형성 구조에 관한 연구 (A Study on the Mechanism of Clusters Formation of ER Fluid Through Visualization)

  • 이은준;박명관
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1684-1691
    • /
    • 2001
  • Electrorheological fluids(ERFs) show a rapid and reversible increase in apparent viscosity by applied electric field. It is called the electrorheological effect (ER effect). The reason for ER effect is the induction of an electric dipole in each particle, leading to the formation of clusters in the direction of the field, which resist fluid flow. Generally, the behavior of ER fluids has been modeled on those of Bingham fluids. But there are some differences between Bingham fluids and ER fluids. The visualization of ER fliuds are presented and ER effects by the forming, growing and breaking of clusters are discussed. In the low shear rate area, the pressure drop is measured by a pressure sensor and the formation of ER particles is visualized by video camera. The reason for the nonlinear behavior of ER fluids at low shear rate is explained through results of visualization. As result, the behavior of ER fluids is nonlinear at low shear rate with overshoot area because it is different to from the clusters according to the strength of electric field. The gap of electrodes becomes narrow because of the cluster layer occurrence near to electrodes in any conditions.

실시간 홀로그래픽 간섭법을 이용한 유체의 가시화 (Visualization and Measurement of Fluids with Real-time Holographic Interferometry)

  • 엄철;강영준;김동우;유원재;안중근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.539-544
    • /
    • 2001
  • The holographic measurement techniques can be applied to various industrial fields such as automobile, airplane, construction, electronics, medical, mechanics and physics. The visualization of fluids is very important in aerodynamics, heat transfer and stress analysis. There are classically optical methods such as shadowgraph, schlieren method, and Mach-Zehnder interferometry for visualizing the fluid flow phenomena. But, it is difficult to understand the continuous state of fluids well in those methods. In this study, the real-time holographic interferometer with high-speed camera is applied to the flow visualization. In addition, collimated laser beam and rotating wedge are used for recording and formation of carrier fringes, respectively.

  • PDF

객체지향형 2차원 유동 가시화 코드 개발 (Code Development for Two-Dimensional Flow Visualization)

  • 사종엽;허준성
    • 한국전산유체공학회지
    • /
    • 제8권1호
    • /
    • pp.30-37
    • /
    • 2003
  • The post-processor for two-dimensional flow visualization has been developed by using OOP(object-oriented programming) of Visual C++. User-friendly GUI(graphic user interface) has been built on the base of MFC(Microsoft Foundation Class). The number and order of variables can be specified by user because the input style is the free-format. The new variable can be defined and added to the variable list by using the various operators and functions.

3 포트 사각 튜브내에서 ER유체의 유동 가시화 (A Flow Visualization of ER Fluids in 3Port Rectangular Tube)

  • 장성철;염만오;장문제
    • 한국공작기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.30-37
    • /
    • 2006
  • The purpose of this study is to visualize the characteristics of ER fluids as preceding step of developing 3 port ER valves. ER fluids are made with silicone oil and 3 weight fraction starch having hydrous particles. The flow visualization of ER fluids flow is obtained by CCD camera with changing the strength of electric field to ER fluids flow. As the strength of the electric field increases, more clusters in flow are made and these clusters are though to be the reasons of the load flow rate being increased and the outlet flow rate being decreased. The ER Valves and load and outlet flow rate check method are considered to be applied to the fluid power control system.

점탄성 유체에 따른 충돌분무의 분무패턴 및 미립화 특성 (Spray Patterns and Atomization Characteristics of Viscoelastic Fluid with Impinging Jet)

  • 이문희;홍정구
    • 한국분무공학회지
    • /
    • 제24권3호
    • /
    • pp.145-151
    • /
    • 2019
  • Viscoelastic fluid is used in various industrial sites because its cost reduction and environmental benefits by preventing formation of fine droplets that scattered around. However, viscoelastic fluids, unlike newtonian fluids, contain a shear thinning characteristic that decrease in viscosity as shear rate increases and elastic characteristic, making it difficult to predict spray breakup process. In this study we made three test fluids. Boger fluid with viscoelastic characteristics, and two newtonian fluids, were prepared to exclude shear thinning characteristics and study the effects of elastic characteristic only. Flow visualization, spray angle, and SMD were measured for three test fluids using laboratory scale impinging jet test apparatus. As a result, it was confirmed that Boger fluid, unlike the newtonian fluid, was not formed fine droplets that scattered around and the breakup process appeared differently. In addition, SMD was found to be large in Boger fluid, and the SMD according to pressure was confirmed that there is no significant difference.

개방형 구조의 진동형 히트파이프의 응축부 길이에 따른 추력 및 유동 가시화 (Thrust and Flow Visualization according to Length of Condenser Section of Open Pulsating Heat Pipe)

  • 손민재;최종욱
    • 한국가시화정보학회지
    • /
    • 제21권3호
    • /
    • pp.57-64
    • /
    • 2023
  • An open pulsating heat pipe operates continuously by inflow and outflow fluids through an open-type condenser. The open pulsating heat pipe is a device capable of obtaining the thrust due to the variation of internal pressure during phase change. Therefore, the open pulsating heat pipe is a suitable device to move fluids if the heat source such as waste heat exists. Many numerical studies have not been sufficiently conducted on the open pulsating heat pipe. In this study, the numerical analysis of the open pulsating heat pipe is performed according to the length of the condenser section. The OpenFOAM software is used to obtain the thrust and the flow visualization for the open pulsating heat pipe.

몰입 환경을 위한 3차원 데이터 후처리 소프트웨어의 데이터 글로브에 의한 제어 구현 (CONTROL OF A 3-DIMENSIONAL POSTPROCESSING SOFTWARE USING DATA GLOVES FOR IMMERSIVE ENVIRONMENT)

  • 김기영;김병수
    • 한국전산유체공학회지
    • /
    • 제11권2호
    • /
    • pp.56-61
    • /
    • 2006
  • As the size and dimension of target problems in the field of computational engineering including CFD gets bigger and higher, it is needed to have more efficient and flexible data visualization environment in terms of software and hardware. Even though it is still manageable to use a mouse in controlling 3-dimensional data visualization, it would be beneficial to use 3-D input device for 3-D visualization. 'Data Glove' is one of the best 3-D input devices, because human hands are best tools for understanding 3-D space and manipulating 3-D objects. Signals coming from 'Data Glove' are analog and very sensitive to finger motions, therefore signal filtering using a digital filter is applied. This paper describes our experience and benefits of using data gloves in controlling 3-dimensional postprocessing softwares.

웹 환경에서의 입체적 가시화를 위한 3-D 가상현실 기법의 적용 (STUDY ON 3-D VIRTUAL REALITY FOR STEREOSCOPIC VISUALIZATION ON THE WEB)

  • 이장훈;박인철;김정훈;김병수
    • 한국전산유체공학회지
    • /
    • 제16권1호
    • /
    • pp.30-35
    • /
    • 2011
  • In this paper, our effort to apply 3-D Virtual Reality system for stereoscopic visualization of mesh data on the web is briefly described. This study is an extension of our previous and on-going research efforts to develop an automatic grid generation program specialized for wing mesh, named as eGWing. The program is developed by using JAVA programming language, and it can be used either as an application program on a local computer or as an applet in the network environment. In this research advancing layer method(ALM) augmented by elliptic smoothing method is used for the structured grid generation. And to achieve a stereoscopic viewing capability, two graphic windows are used to render its own viewing image for the left and right eye respectively. These two windows are merged into one image using 3D monitor and the viewers can see the mesh data visualization results with stereoscopic depth effects by using polarizing glasses. In this paper three dimensional mesh data visualization with stereoscopic technique combined with 3D monitor is demonstrated, and the current achievement would be a good start-up for further development of low-cost high-quality stereoscopic mesh data visualization system which can be shared by many users through the web.

다양한 작동유체로 충전된 폐쇄 루프 맥동 히트파이프 내부 유동패턴 비교 (A comparative study on the flow patterns in closed loop pulsating heat pipe charged with various working fluids)

  • 강석구;김성근;히발 아흐메드;정성용
    • 한국가시화정보학회지
    • /
    • 제17권3호
    • /
    • pp.52-58
    • /
    • 2019
  • Thermal performance and flow patterns inside the closed loop pulsating heat pipe (CLPHP) were experimentally investigated. For investigating the effect of working fluids, CLPHP was filled with various working fluids including methanol, acetone and ethanol. The thermal resistance was calculated by temperatures in evaporator and condenser and flow patterns were visualized by a digital camera. The thermal resistances for all fluids were decreased as the heat increases. Flow patterns change from static slug to elongated slug flows, bulk circulation and annular flows as the heat increases. Dry-out occurs after annular flows. For reasonable comparison of thermal performances, normalized CHF, Kutateladze number (Ku), was compared. Even though ethanol has smallest CHF, Ku of ethanol is similar with that of methanol. In addition, acetone has the highest Ku that means CLPHP with acetone provides the higher thermal performance compared with CLPHP with other fluids.