• 제목/요약/키워드: Fluid storage tank

검색결과 144건 처리시간 0.03초

면진 유체 저장 탱크의 지진취약도 분석 (Seismic Fragility Analysis of Base Isolated Liquid Storage Tank)

  • 안성문;최인길;전영선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.453-460
    • /
    • 2005
  • In this study, the seismic fragility analysis of a base isolated condensate storage tank installed in the nuclear power plant. The condensate storage tank is safety related structure in a nuclear power plant. The failure of this tank affect significantly to the core damage frequency of the nuclear power plants. The seismic analysis of the liquid storage tank was performed by the simple calculation method and the dynamic time storage analysis method. The convective and impulsive fluid mass is modeled as added masses proposed by several researchers. To evaluate the effectiveness of the isolation system, the comparison of HCLPF and core damage frequencies in non-isolated and isolated cases are carried out. It can be found from the results that the seismic isolation system increases the seismic capacity of a condensate storage tank and decreases the core damage frequency significantly.

  • PDF

수직다발관형 빙축열 탱크내 물의 응고과정시 열전달특성에 관한 연구 (An Experimental Study on the Heat Transfer Characteristics during the Freezing Process of Water in the Vertical Multi Tube Type Ice Storage Tank)

  • 김영기;임장순
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.95-105
    • /
    • 1998
  • In this study, basic design data which were required for development of highly efficient ice storage system with low temperature latent heat were experimentally obtained. The ice storage system considered in this study was the one that has been widly used in the developed country and called the ice-on-coil type. Using the system, the ice storage performance for various design parameters which were the flow direction and the inlet temperature of the secondary fluid was tested. In addition, the timewise variation of the interface profiles between the solid and the liquid were visualized, and the heat transfer characteristics of the Phase Change Material(PCM) in the ice storage tank were Investigated. During the freezing processes in the ice storage tank with several vertical tubes, decrease of the heat transfer area and the heat resistance of the ice layer made the increasing rate of ice packing factor(IPF) less. The total freezing energy for the upward flow of the secondary fluid was higher than that for the downward flow. The average ice storage efficiency for the upward flow of the secondary fluid was higher than that for the downward flow.

  • PDF

Pilot LNG저장탱크의 모드 형상 파악을 위한 동특성 실험 (Dynamic Experiment for Mode Shape of Pilot LNG Storage Tank)

  • 이강원;김영균;홍성호;김지훈
    • 한국가스학회지
    • /
    • 제7권3호
    • /
    • pp.18-23
    • /
    • 2003
  • 한국에서의 LNG에 대한 수요는 처음 수입된 1986년 이후로 크게 증가하고 있다. 따라서 LNG 소비에 맞추어 LNG 저장탱크의 확충이 요구된다. 그러나 LNG 저장 설비에 대한 설계, 건설 그리고 분석 분야에서는 유체-구조의 상호 작용과 LNG의 저온 특성 때문에 고정도의 선진 기술이 요구된다. 최근 한국가스공사에서는 Pilot LNG 저장탱크를 건설하였으며 실제 운전을 통한 핵심 기술을 개발하여 축척하고 있다. 한 부분의 연구로서 기초 동특성 시험을 실시하였다. 본 연구에서는 동특성 실험을 수행하였으며, Pilot LNG 저장탱크에 대한 동특성을 검증 및 분석하였다.

  • PDF

복합재료 유체 저장 탱크 구조 설계를 위한 RTM 공법 수지 유동 해석 (Resin Flow Analysis of RTM Manufacturing Method for Design of Composite Fluid Storage Tank Structure)

  • 박현범
    • 항공우주시스템공학회지
    • /
    • 제13권1호
    • /
    • pp.69-76
    • /
    • 2019
  • 본 연구에서 복합재료 구조 설계를 위한 수지 이송 성형 공법의 수지 침투 유동 해석을 수행하였다. 대상 복합재료 구조물은 유체 저장 탱크 구조물이다. 유체 저장 탱크 복합재료 구조물 설계를 위해 자연 섬유 복합재료가 적용되었다. 자연섬유 복합재 구조의 제작을 위해 수지 이송 성형 공법을 채택하였다. 탱크의 적절한 RTM 조건을 도출하기 위하여 수지 침투 유동 해석을 수행하였다. 수지 유동 해석은 상용 유한 요소 해석 시뮬레이션 프로그램을 활용하여 수행하였다. 수지 주입구와 배출구의 다양한 변경에 따른 반복적 해석을 수행하여 최적의 수지 주입 시간과 위치를 결정하였다.

수치해석에 의한 심수 탱크구조물의 진동에 관한 연구 (Numerical Analysis of Vibration Characteristics in Deep Water Tank)

  • 배성용
    • 한국소음진동공학회논문집
    • /
    • 제13권10호
    • /
    • pp.791-797
    • /
    • 2003
  • A liquid storage rectangular tank structures are used In many fields of civil, mechanical and marine engineering. Especially, Ship structures have many tanks In contact with Inner or outer fluid, like ballast, fuel and cargo tanks. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance with exciting force of engine and propeller. Vibration characteristics of these thin walled tanks in contact with fluid near engine or propeller are strongly affected by added mass of containing fluid. Therefore it is essentially important to estimate the added mass effect to predict vibration of the tank structures. In the previous report, we have developed numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present report, using the numerical analysis, vibrations characteristics In deep water tank are investigated and discussed.

수치해석에 의한 심수 탱크구조물의 진동에 관한 연구 (Numerical Analysis of Vibration Characteristics in Deep Water Tank)

  • 배성용;홍봉기;배동명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1079-1084
    • /
    • 2003
  • A liquid storage rectangular tank structures are used in many fields of civil, mechanical and marine engineering. Especially, Ship structures have many tanks in contact with inner or outer fluid, like ballast, fuel and cargo tanks. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance with exciting force of engine and propeller. Vibration characteristics of these thin walled tanks ill contact with fluid near engine or propeller are strongly affected by added mass of containing fluid. Therefore it is essentially important to estimate the added mass effect to predict vibration of the tank structures. In the previous report, we have developed numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present report, using the numerical analysis, vibrations characteristics in deep water tank are investigated and discussed.

  • PDF

파이롯트 LNG저장탱크의 동특성 실험연구 (Experimental Study of Dynamic Response for Pilot LNG Storage Tank)

  • 김영균;이강원;홍성호;김지훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.591-597
    • /
    • 2003
  • The demand of LNG in Korea has dramatically increased since it was first imported in 1986. Thus, more LNG storage tanks are required to meet the growing consumption of LNG. However the design, construction, and analysis of LNG storage facility need highly advanced technology compared to the general structures due to the fluid-structure interaction and the low temperature of LNG. Recently Korea Gas Corporation(KOGAS) constructed a pilot LNG storage tank, and it is in operation to develop and accumulate the core technology. As a part of those objects, the fundamental dynamic test for the pilot tank were performed. For this study, dynamic test were carried out and the dynamic characteristics of the pilot tank were verified and analyzed.

  • PDF

태양열 시스템에 적용된 나선재킷형 축열조의 CFD 해석 (CFD Analysis for Spiral-Jacketed Thermal Storage Tank in Solar Heating Systems)

  • 남진현;김민철;김찬중;홍희기
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.645-653
    • /
    • 2008
  • Spiral-jacketed thermal storage tanks can greatly simplify solar heating systems while maintaining the thermal performance at a similar level as conventional systems with an external heat exchanger. Proper design of the spiral-jacket flow path is essential to make the most of solar energy, and thus to maximize the thermal performance. In the present work, computational fluid dynamics (CFD) analysis was carried out for a spiral-jacketed storage tank installed in a solar heating demonstration system. The results of the CFD analysis showed a good agreement with experimentally determined thermal performance indices such as the acquired heat, collector efficiency, and mixed temperature in the storage tank. This verified CFD modelling approach can be a useful design tool in optimizing the shape of spiral-jacket flow path and the flow rate of circulating fluid for better performance.

부식성 유체 누출 사고사례 연구를 통한 저장탱크 레벨게이지 적정설치에 관한 연구 (A Study on the Proper Installation of Storage Tank Measuring Instruments through a Case Study of Corrosive Fluid Leak Accident)

  • 김상령;조규선;양원백
    • 한국가스학회지
    • /
    • 제27권2호
    • /
    • pp.32-38
    • /
    • 2023
  • 수도권 내 화학공장에서 부식성 유체를 펌프로 저장탱크에 공급하던 도중 수위파악이 정확히 되지 않아 상부 배기벤트로 부식성유체가 누출되는 사고가 발생하였다. 누출 사고가 발생한데는 다양한 원인이 있지만 직접 원인인 레벨게이지의 수위 지시계가 고착되는 것에 초점을 맞추었다. 분석 결과 사고가 발생한 사업장에서 사용되는 수위 지시계를 임의로 교체하였으며, 사고발생인 여름에 Tubular 방식의 레벨게이지는 열팽창이 쉽게 일어나서 다른 형태보다 고착이 발생될 수 있는 것으로 파악되었다. 또한 국내에는 저장탱크에 설치되는 계측기기의 설치기준이 명확치 않아 적정설치 검토에 어려움이 있었다. 따라서 본 연구에서는 사고사례 및 해외기준을 바탕으로 저장탱크 계측기기류 설치 시 유의사항에 대해 검토하였다.

내부 부상형 저장탱크(IFRT) 화재·폭발사고 원인 분석: OO송유관공사 저유소 화재·폭발사건을 중심으로 (Analysis of Cause of Fire and Explosion in Internal Floating Roof Tank: Focusing on Fire and Explosion Accidents at the OO Oil Pipeline Corporation)

  • 구채칠;최재욱
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.86-93
    • /
    • 2020
  • 본 연구는 옥외저장탱크에서 발생한 화재·폭발사고의 근본적인 사례분석을 통해 저장탱크의 안전을 유지할 목적으로 수행되었다. 이 사고는 저장탱크 야드에 사업장 외에서 날아온 풍등이 저장탱크 주변 잔디에 떨어지며 발생한 잔재 화재가 서서히 확산되어 탱크 내부의 유증기와 만나 폭발·화재로 이어진 사고였다. 사고의 원인을 밝혀내기 위하여 CCTV영상분석을 통한 대기확산 조건 도출, 전산유체역학을 이용한 풍향 분석, 플러팅 루프가 최저 위치일 때의 탱크 내부 유증기 발생량, 최고 위치일 때의 탱크 내부 유증기 거동을 통하여 저장탱크의 폭발이 일어난 원인을 밝혀내어 저장탱크의 레벨을 내부부상형 지붕 이하로 유지했을 경우 위험물이 충전되면서 그 공간에 있던 유증기가 내부 부상지붕위에 정체될 가능성이 있으므로 저장탱크의 Low liquid level이 폰튠 서포트 밑에 위치하지 않도록 운전절차를 개선하고, 오픈 벤트에는 화염방지기를 설치하여 화염이 저장탱크로 유입하지 못하도록 하는 대책을 제시하고자 한다.