• 제목/요약/키워드: Fluid injection

검색결과 692건 처리시간 0.025초

사출성형기 유압시스템의 특성 검토를 위한 해석 모델 개발 (Development of Analysis Model for Characteristics Study of Fluid Power Systems in Injection Molding Machine)

  • 장주섭
    • 유공압시스템학회논문집
    • /
    • 제8권4호
    • /
    • pp.1-8
    • /
    • 2011
  • Injection molding machine is the assembly of many kinds of mechanical and fluid power part and electro-electronic control system. From in these, fluid power is a part where becomes the first core of this machine. Fluid power systems of injection molding machine are modelled and analyzed using a commercial program AMESim. The analysis model which is detailed about the parts applied a publishing catalog data. Sub system models which is divided according to functional operation are made and its analysis results shows how design parameters work on operational characteristics like displacement, pressure, flow rates at each node and so on. Total fluid power circuit model is also made and analyzed. The results made by analysis will be used design of fluid power circuit of injection molding machine.

이색 사출성형기 개발을 위한 유압시스템의 특성 검토 (Characteristics Analysis of the Fluid Power System for a Double-color Injection Molding Machine Development)

  • 장주섭
    • 유공압시스템학회논문집
    • /
    • 제8권4호
    • /
    • pp.24-31
    • /
    • 2011
  • Double-color Injection molding machine is the assembly of many kinds of mechanical, fluid power part and electric electronic control system. From in these, fluid power is a part where becomes the first core of this machine. Fluid power systems of double-color injection molding machine are modelled and analyzed using a commercial program AMESim. Partial system models which is divided according to functional operation are made and its analysis results shows how design parameters work on operational characteristics like pressure, flow rates, displacement at each node and so on. Analysis modeling and compared the data which gets from experiment and the analysis result which has a reliability got data. The results made by analysis will be used design of fluid power circuit for developing a double-color injection molding machine.

리저버 탱크의 Die Turning Injection 적용을 위한 Multi-field CAE 해석 (A multi-field CAE analysis for die turning injection application of reservoir fluid tank)

  • 이성희
    • Design & Manufacturing
    • /
    • 제15권1호
    • /
    • pp.66-71
    • /
    • 2021
  • In this study, die turning injection(DTI) mold design for manufacturing reservoir fluid tanks used for cooling in-vehicle batteries, inverters, and motors was conducted based on multi-field CAE. Part design, performance evaluation, and mold design of the reservoir fluid tank was performed. The frequency response characteristics through modal and harmonic response analysis to satisfy the automotive performance test items for the designed part were examined. Analysis of re-melting characteristics and structural analysis of the driving part for designing the rotating die of the DTI mold were performed. Part design was possible when the natural frequency performance value of 32Hz or higher was satisfied through finite element analysis, and the temperature distribution and deformation characteristics of the part after injection molding were found through the first injection molding analysis. In addition, it can be seen that the temperature change of the primary part greatly influences the re-melting characteristics during the secondary injection. The minimum force for driving the turning die of the designed mold was calculated through structural analysis. Hydraulic system design was possible. Finally, a precise and efficient DTI mold design for the reservoir fluid tank was possible through presented multi-field CAE process.

Effects of warmed carrier fluid on nefopam injection-induced pain

  • Cho, Hyung Rae;Kim, Seon Hwan;Kim, Jin A;Min, Jin Hye;Lee, Yong Kyung
    • The Korean Journal of Pain
    • /
    • 제31권2호
    • /
    • pp.102-108
    • /
    • 2018
  • Background: Nefopam is a non-opioid, non-steroidal analgesic drug with fewer adverse effects than narcotic analgesics and nonsteroidal anti-inflammatory drugs, and is widely used for postoperative pain control. Because nefopam sometimes causes side effects such as nausea, vomiting, somnolence, hyperhidrosis and injection-related pain, manufacturers are advised to infuse it slowly, over a duration of 15 minutes. Nevertheless, pain at the injection site is very common. Therefore, we investigated the effect of warmed carrier fluid on nefopam injection-induced pain. Methods: A total of 48 patients were randomly selected and allocated to either a control or a warming group. Warming was performed by diluting 40 mg of nefopam in 100 ml of normal saline heated to $31-32^{\circ}C$ using two fluid warmers. The control group was administered 40 mg of nefopam dissolved in 100 ml of normal saline stored at room temperature ($21-22^{\circ}C$) through the fluid warmers, but the fluid warmers were not activated. Results: The pain intensity was lower in the warming group than in the control group (P < 0.001). The pain severity and tolerance measurements also showed statistically significant differences between groups (P < 0.001). In the analysis of vital signs before and after the injection, the mean blood pressure after the injection differed significantly between the groups (P = 0.005), but the heart rate did not. The incidence of hypertension also showed a significant difference between groups (P = 0.017). Conclusions: Use of warmed carrier fluid for nefopam injection decreased injection-induced pain compared to mildly cool carrier fluid.

오리피스와 방향제어밸브를 이용한 미세유량 분사제어시스템 (Infinitesimal Fluid Injection Control System by using an Orifice and a Directional Control Valve)

  • 정은석;오인호;이일영
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.67-68
    • /
    • 2006
  • This study suggests a precision flow control system that enables fluid injection of a few grams at a time in a few ms time duration. The fluid injection system suggested here consists of a high pressure fluid pump, a 3 way 3 position directional control valve, an injector and an orifice. The orifice is located between the directional control valve and the injector. By supplying current signal to the directional control valve, the prescribed small amount of fluid can be supplied to a plant through the injector. The control robustness of the suggested system against the disturbances like the pressure change in a plant and the viscosity variation of the injected fluid is secured easily by using an orifice with very small inside diameter and setting the supply pressure with comparatively high value. The control performances of the suggested system are verified by numerical simulations and experiments. The outcomes of this research could be applied to the common rail injection control of lubrication oil for large size marine diesel engines, and other industrial plants.

  • PDF

암반 그라우팅 주입 설계변수가 주입성능에 미치는 영향의 수치해석적 평가 (Influence of Design Parameters of Grout Injection in Rock Mass using Numerical Analysis)

  • 이종원;김형목;;박의섭
    • 터널과지하공간
    • /
    • 제27권5호
    • /
    • pp.324-332
    • /
    • 2017
  • 본 연구에서는 암반 절리 내 점성유체 주입시 주입 설계변수가 주입 성능에 미치는 영향을 평가할 목적으로 UDEC 프로그램을 사용하여 1차원 선형유동 해석을 수행하였다. 주입 설계변수로는 주입 압력, 유체 압축률, 주입재의 항복강도 및 점성도의 시간의존성, 주입 압력에 의한 절리의 역학적 변형을 설정하였으며, 주입재의 침투거리 및 주입 유량을 통해 주입 성능을 평가하였다. 수치해석 결과는 이론해를 통하여 파악한 주입 성능양상과 유사한 결과를 보였다. 주입재의 항복강도 및 점성도의 시간의존성을 고려하지 않을 경우, 주입재의 누적 주입량은 시간의존성을 고려한 해석에 비하여 약 1.2배 크게 평가되었다. 또한, 수리-역학 연계해석결과로부터 주입 압력에 의한 절리의 역학적 변형이 발생하는 경우, 절리 간극이 일정한 수리유동 해석에 비하여 누적 주입량이 약 4.4배 늘어나는 결과를 보였다.

경막외강(硬膜外腔)에 주입(注入)한 생리식염수(生理食鹽水)가 뇌척수액압(腦脊髓液壓)에 미치는 영향(影響) (Cerebrospinal Fluid Pressure Changes Following the Injection of Saline into the Epidural Space)

  • 전재규;이석강;주영은
    • The Korean Journal of Physiology
    • /
    • 제11권1호
    • /
    • pp.21-26
    • /
    • 1977
  • Many cases have been reported that a post spinal headache can be relieved immediately by an epidural injection of saline; and autologous blood also has recently been used successfully instead of saline. The changes of the cerebrospinal fluid pressure in 40 cases were observed in the present study in support of the concept; that a continuous leakage in association with hypovolemia and hypotension of the cerebrospinal fluid is the primary cause of a post spinal headache. Subarachnoid pressure increased immediately with saline injection into the lumber epidural space. A spinal needle was inserted into the subarachnoid space at the level of $L2{\sim}3$ and opening pressure of the cerebrospinal fluid was read. An epidural Tuohy needle was insertad at the$L3{\sim}4$ and 25m1 of saline was injected into the epidural space and the cerebrospinal fluid pressure was read in the sitting position. $\underline{Sitting\;Position:}$ Mean pressure after injection $555{\pm}(110.9)mm\;H_2O$, Pressure rise rise (%) 51.3%, Mean opening pressure $366{\pm}(52.2)mm\;H_{2}O$, $\underline{Lateral\;position:}$ Mean pressure after injection $308{\pm}(70.8)mm\;H_{2}O$, Pressure(%) 86.7%, Mean opening pressure $165{\pm}(42.6)mm\;H_{2}O$. These pressure changes responded almost simultaneously as saline was injected. This pressure rise of 51.3% in the sitting position and 86.7% in the lateral position are clinically very significant. Therefore, it is most possible that the immediate relieve of post, spinal headache by injection of fluid into the epidural space is simultaneous with the increase of the cerebrospinal fluid pressure.

  • PDF

수리자극에 의한 지열저류층에서의 유도지진과 단층대의 변형에 관한 입자기반 개별요소법 모델링 연구 (Particle Based Discrete Element Modeling of Hydraulic Stimulation of Geothermal Reservoirs, Induced Seismicity and Fault Zone Deformation)

  • 윤정석;아미르 하킴하쉐미;아노 짱;귄터 찜머만
    • 터널과지하공간
    • /
    • 제23권6호
    • /
    • pp.493-505
    • /
    • 2013
  • 본 수치해석논문에서는 절리와 단층대를 포함한 지열저류층에 수리자극을 가할 시 수반되는 유도지진과 단층대의 변형을 개별요소법을 사용하여 모델링하였다. 수채해석기법은 2차원 입자유동코드를 기반으로 하며 수리역학적 상호작용기법과 미소파괴음의 모멘트텐서 역산알고리즘이 결합되었다. 수치해석의 주요결과로는 시공간적으로 변하는 유도지진의 분포와 규모 그리고 단층대의 변형(파괴 및 전단변위)과 주입유체압력의 시공간적 분포와의 상관관계이다. 첫 번째 수치해석으로부터 절리가 분포하는 지열저류층에서의 수리자극에 의한 유도지진의 분포는 주입유체의 점성에 상당한 영향을 받는 것으로 나타났다. 주입유체의 점성이 낮은 경우 (1 cP), 유도지진의 발생범위가 큰 것으로 나타났으며, 주입 후 발생하는 유도지진의 개수와 규모 또한 높게 나타났다. 단층대가 존재하는 지열저류층의 수리자극 모델링의 결과, 주입정의 위치가 단층대와 가까운 경우 작은 주입수 압력분포(<0.1 MPa)로도 단층대의 파괴와 전단변형을 일으킬 수 있는 것으로 나타났다. 본 논문에서 소개한 수치해석기법은 수리자극을 통한 지열저류층 개발 시 유도지진의 분포와 규모를 실제 유체주입작업전에 예측할 수 있게 함으로써 지열에너지개발 분야에서 유용하게 사용될 수 있을 것으로 기대한다.

수압작용에 따른 지반내 공동생성 및 수리거동에 대한 개별요소해석 (Distinct element simulation of cavity development and fluid behavior caused by fluid injection)

  • 전제성;김기영;김재홍;이종욱
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.676-679
    • /
    • 2008
  • Numerical simulations of fluid injection into particulate materials were conducted to observe cavity initiation and propagation using distinct element method. After generation of initial particles and wall elements, confining stress was applied by servo-control method. The fluid scheme solves the continuity and Navior-Stokes equations numerically, then derives pressure and velocity vectors for fixed grid by considering the existence of particles within the fluid cell. Fluid was injected as 7-step into the assembly in the x-direction from the inlet located at the center of the left boundary under confining stress condition, 0.1MPa and 0.5MPa, respectively. For each simulation, movement of particles, flow rate, fluid velocity, pressure history, wall stress including cavity initiation and propagation by interaction of flulid-paricles were analyzed.

  • PDF

위치기반서비스를 활용한 효율적인 수액 모니터링 단말기 디자인에 관한 연구 (Studies on Effective Fluid Monitoring Terminal design with the Use of location-based service)

  • 이효승;오재철
    • 한국전자통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.421-426
    • /
    • 2016
  • 수액은 일반적으로 환자에게 특정 주사를 일정 시간동안 주입하기위해 사용되어진다. 환자나 보호자는 수액의 투입종료 시점을 예상하여 의료진을 호출하여야 하는 경우가 많고, 취침시간 등 특정 시간에 수액투여가 종료될 경우 환자나 보호자에게 더 많은 피로를 줄 수 있다. 또한 의료진은 수액의 투입종료시점을 확인하기 위하여 몇 번이고 현장에 찾아가 수액의 양을 모니터링 해야 하는 수고로움으로 업무의 비효율성을 가져올 수 있을 것이다. 본 논문에서는 이러한 문제를 해결하기 위해서 수액의 수위를 감시하는 최소한의 장비와 능동형 RFID를 결합한 형태의 위치기반 서비스 시스템을 제안하고, 환자별 수액의 양과 환자의 위치를 실시간 파악하여 환자나 보호자 또는 의료인(간호사)에게 정확한 정보를 제공하여 수액 투여가 마무리될 시점에 의료진이 환자의 위치로 찾아가는 서비스로 의료서비스의 질을 향상시킬 수 있을 것으로 기대한다.