• 제목/요약/키워드: Fluid Space

검색결과 975건 처리시간 0.027초

구심터빈의 노즐 내부 유동에 대한 시험 연구 (An Experimental Study on Flow in the Nozzle of a Radial Turbine)

  • 강정식;임병준;안이기
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.35-41
    • /
    • 2010
  • Experimental study on the flow field inside the nozzle for radial turbine was performed. At design point, the pressure is high and the Mach number is low at the pressure side of the nozzle inlet semi-vaneless space as the flow turns through the nozzle vanes. As the flow accelerates through the nozzle passage to the throat the pressure level at the pressure and suction sides becomes similar. The flow continued accelerating from the throat to the inlet of turbine wheel and the pressure field became uniform in the circumferential direction in the vaneless space. In high expansion ratio condition, strong favorable pressure gradient band region occurred just after the throat in the semi-vaneless space in the circumferential direction and the pressure became uniform in the circumferential direction after this band. In low expansion ratio condition, core flow acceleration is dominant after the throat and this non-uniform pressure field reached to the inlet of turbine wheel.

Giant plunging ranula: a case report

  • Kim, Seong-Ha;Huh, Kyung-Hoe;An, Chang-Hyeon;Park, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • 제43권1호
    • /
    • pp.55-58
    • /
    • 2013
  • A ranula is a bluish, transparent, and thin-walled swelling in the floor of the mouth. They originate from the extravasation and subsequent accumulation of saliva from the sublingual gland. Ranulas are usually limited to the sublingual space but they sometimes extend to the submandibular space and parapharyngeal space, which is defined as a plunging ranula. A 21-year-old woman presented with a complaint of a large swelling in the left submandibular region. On contrast-enhanced CT images, it dissected across the midline, and extended to the parapharyngeal space posteriorly and to the submandibular space inferiorly. Several septa and a fluid-fluid level within the lesion were also demonstrated. We diagnosed this lesion as a ranula rather than cystic hygroma due to the location of its center and its sublingual tail sign. As plunging ranula and cystic hygroma are managed with different surgical approaches, it is important to differentiate them radiologically.

건축 내$\cdot$외부공간 경계의 모호성에 관한 연구 (A Study on the Ambiguity of the Boundary in the Architectural Interior and Exterior Space)

  • 곽기표
    • 한국실내디자인학회논문집
    • /
    • 제14권2호
    • /
    • pp.20-28
    • /
    • 2005
  • This paper investigates that the ambiguity of the boundary between interior space and exterior space in architecture appears universally in history and reveals the various aspects of ambiguous boundary in architecture. The space is formed by the relationship with the surroundings and the boundary of two opposite spaces is apt to be ambiguous according to lots of complex factors. Before Modern Architecture the boundary of interior and exterior space had a tendency to be ambiguous by modifying compositional method of material boundary, that is semi interior-exterior space, the reversion of interior and exterior space and space in space. After Modern Architecture the meaning of physical boundary in space is lost along with dissolution of boundary over the society and the boundary of space comes to be dematerialized by the technology and the change of space perception. The phenomenon of deconstruction in spacial boundary accelerate increasingly according to fluid space, mutually interpenetrated space, visual transparency and adjustment of layers. And contemporary technology is collapsing the meaning itself of space division fundamentally.

Conversion of Extraordinary Waves into Upper Hybrid Waves in Inhomogeneous Plasmas

  • Kim, Gyeong-Seop;Kim, Eun-Hwa;Lee, Dong-Hun
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권1호
    • /
    • pp.35-35
    • /
    • 2004
  • Inhomogeneity Is important in wave coupling and mode conversion. We numerically examine the conversion of extraordinary(X) waves into upper hybrid(UH) waves in inhomogeneous plasmas by using a three-dimensional multi-fluid numerical model. A one-dimensional Inhomogeneous density profile is assumed in a cold and collisionless plasma. The density gradient is taken to be perpendicular to the magnetic field. An impulsive input is assumed to excite the X waves in the inhomogeneous box model. (omitted)

  • PDF

비대칭 전극계에서의 1차원적 RF 플라즈마 모델링에 관한 연구 (Study on RF Plasma Modeling Between Unequal-Sized Electrodes Using One-dimensional Fluid Method)

  • 소순열;임장섭
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.35-41
    • /
    • 2004
  • 본 연구에서 사용된 방전 기체는 오염물의 제거 및 박막 표면 정제 등의 연구 분야에 응용되고 있는 질소 가스를 사용하였으며, 1차원 동심구 모델의 개발로 인하여, 접지 면적을 넓게 함에 따라 경방향으로의 플라즈마 분포가 중심축의 분포와 동일하다는 1차원적 가정이 적절하지 못하다는 Barnes 모델을 보완할 수 있었다. 일정한 인가 전압하에서는 입체각($\omega$)의 증가에 따라 질소 플라즈마를 구성하는 각 입자의 수밀도 분포, 전계 및 포텐셜이 감소함을 볼 수 있었다. 그러나 면적비가 증가하면서 구동 전극에서의 각 입자들의 움직임은 상대적으로 높은 전계로부터 더욱 활발하게 형성됨에 따라 직렬 연결된 블로킹 콘덴서에서 발생하는 자기 바이어스 전압은 증가하는 것을 알 수 있었다.

Slat Noise Source Modeling of Multi-element Airfoil in High-lift Configuration

  • Hwang, Seung Tae;Han, Chang Kyun;Im, Yong Taek;Kim, Jong Rok;Bae, Youngmin;Moon, Young J.
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권2호
    • /
    • pp.197-205
    • /
    • 2017
  • We investigate the slat noise generation mechanism by using large-eddy simulation (LES) and simple source modeling based on linearized Euler equations. An incompressible LES of an MD 30P30N three-element airfoil in the high-lift configuration is conducted at $Re_c=1.7{\times}10^6$. Using the total derivative of the hydrodynamic pressure (DP/Dt) acquired from the incompressible LES, representative noise sources in the slat cove region are characterized in terms of simple sources such as frequency-specific monopoles and dipoles. Acoustic radiation around the 30P30N multi-element airfoil is effectively computed using the Brinkman penalization method incorporated with the linearized Euler equation. The directivity pattern of $p^{\prime}_{rms}$ at $r=20c_{slat}$ in the multiple sources is closely compared to that obtained by the application of the LES/Ffowcs-Williams and Hawking's methods to the entire flow field. The power spectrum of p' at ${\theta}=290^{\circ}$ is in good agreement with the data reported in BANC-III, especially the broadband part of the spectrum with a decaying slope ${\propto}f^{-3}$.

유체-구조 연성 해석을 위한 common-refinement 기반 불일치 격자 경계면에서의 정보 전달 기법 연구 (The study of data transfer method non-matching meshes interface using common-refinement method for fluid-structure interface)

  • 한상호;김동현;이창수;김종암
    • 한국항공우주학회지
    • /
    • 제42권3호
    • /
    • pp.191-198
    • /
    • 2014
  • 본 연구는 유체-고체 연성 해석이 활발히 진행되고 있는 고체로켓의 3차원 연소실 상경계면 형상에 대해 정보 전달 기법 중 하나인 공통세분 기법의 적용을 목적으로 수행되었다. 본 기법은 불일치하는 경계면간 정보 전달에도 보존성과 정확도를 동시에 만족시킬 수 있다는 장점을 갖는다. 기법 구현은 상경계면에 공통표면을 구성하고 특정 오차를 최소화 시키는 최소화 내삽법을 적용하는 과정으로 수행되었다. 이를 바탕으로 다양한 다차원 상경계면 형상에서 연속 및 불연속 함수를 이용한 정보 전달 실험을 수행하였고, 다른 기법들과 해석 결과를 비교하였다.

2유체 미세 물분무 소화노즐의 분무유동 특성 (Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression)

  • 김봉환;최효성;김동건
    • 한국기계가공학회지
    • /
    • 제10권3호
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

첨단 유동가시화 기법들과 Blue Ocean 전략 (Advanced Flow Visualization Technologies and Blue Ocean Strategy)

  • 이상준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.145-146
    • /
    • 2006
  • Recently, the next-generation advanced flow visualization techniques such as holographic PIV, dynamic PIV, echo-PIV, micro/nano-PIV, and X-ray PIV have been introduced. These advanced measurement techniques have a big potential as the core technology for analyzing outmost thermo-fluid flows in future. These would be indispensable in solving complicated thermo-fluid flow problems not only in the industrial fields such as automotive, space, electronics, aero- and hydro-dynamics, steel, and information engineering, but also in the research fields of medical science, bio-medical engineering, environmental and energy engineering etc. Especially, NT (Nano Technology) and BT (Bio Technology) strongly demand these advanced measurement techniques, because it is impossible for conventional measurement methods to observe most complicated nano- and bio-fluidic phenomena. In this presentation, the basic principle of these high-tech flow visualization techniques and their practical applications which cannot be resolved by conventional methods, such as blood flows in a micro-tube, in vivo analysis of micro-circulation, and flow around a living body will be introduced as a blue ocean strategy.

  • PDF

Analytical Head-space Supercritical Fluid Extraction Methodology for the Determination of Organochlorine Compounds in Aqueous Matrix

  • Ryoo, Keon-Sang;Ko, Seong-Oon;Hong, Yong-Pyo;Choi, Jong-Ha;Kim, Yong-gyun;Lee, Won-Kyoung
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권5호
    • /
    • pp.649-656
    • /
    • 2006
  • The proposed head-space supercritical fluid extraction (SFE) methodology as an alternative to an existing conventional procedure was explored for the determination of organochlorine compounds in aqueous matrix. In this study, polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) were utilized as target analytes. To enhance the recovery efficiency, the factors such as the $CO _2$ density, the extraction time, and the extraction mode were investigated. Furthermore, the analytical procedures and the results obtained were compared with those provided by the conventional method (the U.S. EPA method 8080). Under the optimized conditions, i.e., a combination of static with dynamic SFE mode at 2,000 psi and 40 ${^{\circ}C}$, the head-space SFE methodology gave equivalent or better to the conventional method in recovery efficiencies with clear advantages such as simple sample treatment and fast analysis time as well as reduced solvent and reagent consumption.