• 제목/요약/키워드: Fluid Power Cylinder

검색결과 149건 처리시간 0.02초

카운터밸런스밸브와 차동실린더회로를 포함한 호이스트 유압장치의 최적설계 (Optimal Design of the Hoist Hydraulic System Including the Counter Balance Valve and Differential Cylinder Circuit)

  • 이성래
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2008
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, counter balance valve, and flow control valves. The flow capacity coefficients of flow control valves should be adjusted so that the hoist is operated at moderate speed and the hydraulic energy loss is minimized. However, it is difficult to adjust the flow coefficients of flow control valves by trial and error for optimal operation. Here, the steady state model of the hoist hydraulic system including the differential cylinder circuit is derived and the optimal flow capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

Rotating cylinder를 이용한 탄소강의 유동가속부식 평가 (Evaluation of Flow Accelerated Corrosion of Carbon Steel with Rotating Cylinder)

  • 박태준;이은희;김경모;김홍표
    • Corrosion Science and Technology
    • /
    • 제11권6호
    • /
    • pp.257-262
    • /
    • 2012
  • Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. Rotating cylinder FAC test facility was designed and fabricated and then performance of the facility was evaluated. The facility is very simple in design and economic in fabrication and can be used in material and chemistry screening test. The facility is equipped with on line monitoring of pH, conductivity, dissolved oxygen(DO), and temperature. Fluid velocity is controlled with rotating speed of the cylinder with a test specimen. FAC test of SA106 Gr. B carbon steel under 4 m/s flow velocity was performed with the rotating cylinder at DO concentration of less than 1 ppb and of 1.3 ppm. Also a corrosion test of the carbon steel at static condition, that is at zero fluid velocity, of test specimen and solution was performed at pH from 8 to 10 for comparison with the FAC data. For corrosion test in static condition, the amount of non adherent corrosion product was almost constant at pH ranging from 8 to 10. But adherent corrosion product decreased with increasing pH. This trend is consistent with decrease of Fe solubility with an increase in pH. For FAC test with rotating cylinder FAC test facility, the amount of non adherent corrosion product was also almost same for both DO concentrations. The rotating cylinder FAC test facility will be further improved by redesigning rotating cylinder and FAC specimen geometry for future work.

사판식 피스톤형 유압펌프에서의 실린더내 압력, 맥동, 소음에 관한 실험적 연구 (A Study on Pressure, Flow Fluctuation and Noise in the Cylinder of Swash Plate Type Axial Piston Pump)

  • 장동혁;이상규;권정호;박성환
    • 유공압시스템학회논문집
    • /
    • 제6권3호
    • /
    • pp.1-9
    • /
    • 2009
  • Noise reduction for hydraulic pump is strongly demanded in the market with its efficiency and durability. In order to meet this demand, it is necessary to reveal mechanism for noise and relationship between the important factors. In this paper, mathematical model for cylinder pressure which is primary reason of pulsation and sound noise were established, and examined its pressure profile by simulation. Also, the valve plate of three kind types are manufactured and tested for piston pressure, pressure pulsation, and sound power level based on the tentative standard which is officially recognized.

  • PDF

사축식 유압 피스톤 펌프의 디스크 편심률에 따른 실린더블록 구동영역에 대한 연구 (A Study on Driving Range of Cylinder Block to Eccentricity Ratio of Disk in Bent axis Type Oil Hydraulic Piston Pump)

  • 정재연;백일현;조인성;송규근;오석형;정용욱
    • 유공압시스템학회논문집
    • /
    • 제5권2호
    • /
    • pp.1-7
    • /
    • 2008
  • To improve the performance of the bent axis type axial piston pump driven by the tapered piston, it is necessary to know the driving characteristics and mechanism of the tapered piston and the cylinder block. Since each piston not only rotates on its axis and reciprocates in the cylinder bore, but also revolves around the axis of the driving shaft, it is difficult to analyze the driving mechanism theoretically. The theoretical mechanism far the bent axis type axial piston pump is studied by using the geometrical method. The driving range of the tapered piston is determined by theoretical equations. The results show that the cylinder block is driven by one tapered piston in a limited range and the core parameters such as driving factor of the piston and the ahead delay angle influenced performance of the bent axis type axial piston pump.

  • PDF

사축식 유압 피스톤 펌프의 저속 마찰 특성 개선 (Improvement of the Low-speed Friction Characteristics of a Bent-Axis Type Hydraulic Piston Pump)

  • 홍예선;이상율;김치붕;김성훈;임현식;김성대
    • 유공압시스템학회논문집
    • /
    • 제1권3호
    • /
    • pp.7-13
    • /
    • 2004
  • The hydraulic pump for a Electro-hydrostatic Actuator for aircrafts should be able to quickly feed large volume of oil into hydraulic cylinder in order to reduce the response time. On the other hand, it should be also able to precisely dispense small amount of oil by low-speed operation so that the steady state position control error of the EHA can be accurately compensated. This paper is focused on the investigation how the plasma coating surface treatment of cylinder barrel with CrSiN can contribute to the reduction of low-speed friction torque of a bent-axis type piston pump. The results showed that the reduction of the friction torque was not remarkable, but that the anti-wear characteristics of the CrSiN-coated cylinder barrel were much better that those of the original one.

  • PDF

콤플렉스법에 의한 롤러-링크 부착형 전도수문 구동용 유압실린더의 최적 설치점 설계 (Design of Optimal Locating Point of the Hydraulic Cylinder Actuating a Roller-Link Type Rotating Floodgate)

  • 이성래
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권3호
    • /
    • pp.29-36
    • /
    • 2012
  • The hydraulic cylinder is used for actuating the roller-link type rotating floodgate which controls the volume of water in the reservoir. The locating points of hydraulic cylinder are restricted to the limited space and determined to minimize the cylinder force necessary for actuating the floodgate. Generally, the head end point of cylinder is fixed at underground and the rod end point of cylinder is connected to the support link. Therefore there exist three design variables to be determined to minimize the cylinder force within the rotating range of floodgate. First, the mathematical model of the roller-link type rotating floodgate is derived to find the cylinder force corresponding to the floodgate angle. Then, the optimal locating point of hydraulic cylinder is searched using the complex method that is one kind of constrained direct search method.

유체-구조 상호작용을 적용한 튜브다발의 유체탄성불안정성 과도적 전산해석 (Multi-Physics Simulations of Fluidelastic Instability for Tube Bundles in Cross-Flow)

  • 이민형;김용찬
    • 대한기계학회논문집B
    • /
    • 제28권2호
    • /
    • pp.174-180
    • /
    • 2004
  • Failure of tube bundles due to excessive flow-induced vibrations continues to affect the performance of nuclear power plant Early experimental studies concentrated on rigid structures and later investigators dealt with elastic structures because of their importance in many engineering fields. On the other hand, much less numerical work has been carried out, because of the numerical complexity associated with the problem. Conventional approaches usually decoupled the flow solution from the structural problem. The present numerical study proposes the methodology in analyzing the fluidelastic instability occurring in tube bundles by coupling the Computational fluid Dynamics (C%) with the tube equation of motions. The motion of the structures is modeled by a spring-damper-mass system that allows transnational motion in two directions (a two-degree-of-freedom system). The fluid motion and the cylinder response are solved in an iterative way, so that the interaction between the fluid and the structure can be accounted for property. The aim of the present work is to predict the fluidelstic instability of tube bundles and the associated phenomena, such as the response of the cylinder, the unsteady lift and drag on the cylinder, the vortex shedding frequency.

시일이 없는 유압 실린더용 피스톤의 이론해석 (Theoretical Analysis of Sealless Piston for Hydraulic Cylinders)

  • 박태조
    • 유공압시스템학회논문집
    • /
    • 제3권3호
    • /
    • pp.1-7
    • /
    • 2006
  • In this paper, a theoretical analysis is carried out to study the lubrication characteristics of sealless piston for hydraulic cylinders. The analytical pressure distributions are obtained solving one-dimensional Reynolds equation with partially tapered moving piston. Nearly analytical expressions for lateral forces acting on the piston and leakage flow rate through the clearance are also presented. Using the analytical expressions, the influence of design parameters on lubrication characteristics can be easily evaluated without numerical analysis. Composite-shaped piston which minimizes the leakage flow rate is the optimum in sealless piston for hydraulic cylinder.

  • PDF

공압시스템의 설계 파라미터 최적화 (Optimization of Design Parameters of a Pneumatic System)

  • 엄태준
    • 유공압시스템학회논문집
    • /
    • 제2권4호
    • /
    • pp.1-6
    • /
    • 2005
  • This paper presents optimization of a pneumatic control system whose design parameters have been optimized so that the desired dynamic characteristics of cylinder position was obtained. The pneumatic system is used as transferring and stacking equipment for solid freeform fabrication system which has been widely used in design verification applications. The pneumatic system mainly consists of pneumatic control valves and cylinders. The system was modeled by using several principles for pneumatic components. The system was optimized to obtain dynamic performance with enough damping to reduce cylinder vibration. A fuzzy controller has been applied to fulfill the dynamic performance requirements of the pneumatic system. The simulation results show that the fuzzy controller is more effective than a PD controller.

  • PDF