• Title/Summary/Keyword: Fluid Measure

Search Result 473, Processing Time 0.035 seconds

An experimental study on the viscosity of visco-elastic fluids (점탄성유체의 점성에 관한 실험적 연구)

  • 김춘식;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.21-41
    • /
    • 1982
  • Viscosity, especially characteristic among various properties of visco-elastic fluids such as high polymer solutions, is affected mainly by temperature and concentration. Hence, it is important for fluid engineering to express, by some equations, how the fluid characteristics vary with the change of temperature and concentration and to analyze them to obtain consistent viscous characteristics. High polymer solutions, synthetic products of modern chemical industry, suggest many interesting investigations because they are typical visco-elastic materials. Experimentation was made to derive some useful fluid characteristic equations of SEPARAN-NP10 (polyacylamide) expressed by n (flow behavior index) and K' (consistency index) when it is given temperature and concentration variation. To measure viscosity, capillary viscometer was adopted and the range of experimentation is 0-2,000 P.P.M. in concentration and 15-55 .deg.C in temperature. The experimental results are summarized as follows: The flow behavior index n 1) has nearly constant results irrespective of temperature variation at same conentration and the results are shown in (Table. 4-4-3) 2) has following equation, regardless of temperature, for the variation of concentration. n=-1.0765*10$^{-4}$ P+0.9915 (P:P.P.M.) The consistency index K' 1) has different results for the variation of temperature at same concentration and the results are given in (Table.4-7-2) 2) has following equation for the variation of concentration at same temperature. log 10$^{4}$K' =6.4785*10$^{-4}$ P-1.0529 (P:P.P.M)

  • PDF

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

Solubility Measurement and its Correlation of Disperse Dye in Supercritical HFC-134a (초임계 HFC-134a에 대한 분산염료의 용해도 측정과 모델링)

  • Park, Min-Woo;Bae, Hyo-Kwang
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.715-718
    • /
    • 2002
  • The supercritical dyeing process has been gaining the increasing importance because of environment reason. For further development of this process, it is needed to measure the solubility in supercritical fluids in the extensive ranges of temperature and pressure. In this study, using the semi-flow type apparatus consisted of supercritical fluid equilibrium cell, the solubility of disperse dye(C.I. disperse red 60) in supercritical HFC-134a has been measured at the temperatures of 383.2 K and 413.2 K, and in the pressure range of 50 bar to 160 bar. The solubility data are, with good agreement, correlated by an expanded liquid model which considers the supercritical fluid as compressed liquid.

A study on the water receptivity of Korea coated paper by the fluid bridge method (액체 브릿지법에 의한 국산 도피지의 수리성 측정 연구)

  • Han, Sam-Hwa;Jeon, Su-Kyoung;Youn, Jong-Tae
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.23 no.2
    • /
    • pp.143-159
    • /
    • 2005
  • The printing could not expect the print effect of the specific character of a printing material. Specially, a property of the paper that we are aware of the substrate has controled printability as well as run ability. The objective of this study was to measure substrate properties by measuring the water receptivity in order to know the degree of the uniformity on surface of paper. Therefore, the water receptivity was measured by fluid bridge method. And then the physical properties of samples such as ink set-off, porosity and print mottle of domestic coated papers were measured by Tappi method. Accordingly, this study obtained the outcome of water receptivity. And then we could know that the relations between water receptivity and physical properties of the paper samples have correlations. There are many measurement equipments to find out print mottle by the measurement of the reflected density at this point in time. However, it is thought that the fluid bridge method is the most proper way to find out print mottle, though there are many other ways to figure out.

  • PDF

Assessment of Hydration on the Stratum Corneum and the Influencing Factors in Neonates (신생아의 피부표현 별 수분율 측정과 관련요인 분석)

  • Ahn, Young-Mee;Shin, Eun-Jin
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.5
    • /
    • pp.781-789
    • /
    • 2007
  • Purpose: The study was conducted to investigate the skin hydration level in various body sites and identify the influencing factors in neonates. Methods: An exploratory comparison study was designed to measure the stratum corneum hydration, using a National DM-R2 on the forehead, abdomen, buttocks, and the back of the hands and feet of 198 neonates including 92 premature infants. Results: The results showed 32.7%-36.5% of stratum corneum hydration for all sites. Premature infants revealed a higher hydration level on the peripheral sites (dorsal hand and feet) than those of the full-term infants, possibly resulting from therapeutic regimens including an incubator or radiant warmer. Infants in an incubator showed a higher hydration level than those in radiant warmers, suggesting more attention to fluid management for infants in the open environment. In addition, all stratum corneum hydration measurements except one, from the forehead, showed a positive correlation with postnatal age in full-term infants while showing no relation to any measurements in premature infants. Conclusion: The study demonstrated the very low skin hydration levels in hospitalized neonates, particularly in premature neonates with more susceptible skin hydration instability despite therapeutic interventions for fluid balance. More vigilant fluid management is imperative in neonates, particularly those in the open environment.

Effect of Inoculum and Carbon Sources Difference on Characteristics of Anaerobic Digestion (접종원 및 탄소원의 차이가 혐기소화 특성에 미치는 영향)

  • Choi, Yong Jun;Ryu, Jeong Won;Lee, Sang Rak
    • Journal of Korea Society of Waste Management
    • /
    • v.34 no.5
    • /
    • pp.474-481
    • /
    • 2017
  • This study was conducted to investigate the effects of inoculum and carbon sources on anaerobic digestion characteristics. The treatments were combinations of inoculum (digestate of cattle manure and rumen fluid) with carbon sources (starch, cellulose, and xylan). Anaerobic digestion was performed in triplicate at $37^{\circ}C$ for 18 days at 100 rpm. Sampling was performed at 0, 1, 2, 3, 4, 5, 7, 9, 12, 15, and 18 days to measure pH, ammonia-N, volatile solids reduction, the cumulative methane content, and the cumulative methane production. There was a significant difference in methane content depending on the carbon source and there was a significant difference in pH, ammonia-N, methane production, and methane content depending on the inoculum (P < 0.05). The results of methane production were higher in the digestate of cattle manure treatment than in the rumen fluid treatment (P < 0.05). In this study, different digestive patterns depending on the type of carbon source could be used as basic research data to set the hydraulic residence time of anaerobic digestion facilities. In addition, the use of ruminal fluid as an inoculum may help accelerate the hydrolysis and acid production steps.

Numerical analysis of the thermal fluid characteristics of phase change material in can type container (수치해석과 실험을 통한 Can type container 내부 상변화 물질의 열유체적 특성분석)

  • Seung Min Heo;Su Woong Hyun;Hee Jun Jeong;Dong Ho Shin
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.63-71
    • /
    • 2023
  • Energy storage and distribution technologies are emerging as important factors as research on renewable energy continues. Analyzing the thermal flow of phase change material inside a latent heat storage device and to predict the phase change time is an important part for improvement of thermal performance. However, most of the current research is based on the trial-and-error experimental investigation to measure the phase change time. Therefore, in this study, a can-type phase change material container was designed, and the numerical method for analyzing the thermal flow of phase change material was established and validated. The error rate of the phase change time between the numerical and experimental results was within 5%, which proves its reliability. As a result, the phase change finishing times were found to be 78 minutes with inlet fluid temperature of 80℃ during charging process, and 126 minutes with inlet fluid temperature of 9℃ during discharging process.

Optimization of Control Parameters for Hydraulic Systems Using Genetic Algorithms (유전알고리듬을 이용한 유압시스템의 제어파라메터 최적화)

  • Hyeon, Jang-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.9
    • /
    • pp.1462-1469
    • /
    • 1997
  • This study presents a genetic algorithm-based method for optimizing control parameters in fluid power systems. Genetic algorithms are general-purpose optimization methods based on natural evolution and genetics. A genetic algorithm seeks control parameters maximizing a measure that evaluates system performance. Five control gains of the PID-PD cascade controller fr an electrohydraulic speed control system with a variable displacement hydraulic motor are optimized using a genetic algorithm in the experiment. Optimized gains are confirmed by inspecting the fitness distribution which represents system performance in gain spaces. It is shown that optimization of the five gains by manual tuning should be a task of great difficulty and that a genetic algorithm is an efficient scheme giving economy of time and in labor in optimizing control parameters of fluid power systems.

The Effect of Upstream Disturbances on the Performance of Swing Check Valves (상류측 교란요소가 스윙형 역지밸브의 성능에 미치는 영향)

  • Song, Seok-Yoon;Yoo, Seong-Yeon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.1 s.40
    • /
    • pp.41-48
    • /
    • 2007
  • The effect of the upstream flow conditions on the disc stability of the swing check valves was investigated at various upstream flow disturbance sources and distances from the tested check valves. The experimental loop was designed and installed to measure the disc positions, disc back stop load, and differential pressure at flow velocities lot 3 inch and 6 inch swing check valves. The selected disturbance sources are elbow and globe valve. The effect of the disc fluctuation is different depending on the type of disturbance and the distance between the disturbance and the check valve. Disturbances generated by elbow and globe valve located upstream from check valve create greater and more violent disc motion than uniform flow.

The Flow Characteristics in a Vaneless Diffuser by PIV Measurements (PIV측정에 의한 깃 없는 디퓨저에서의 유동특성)

  • Yoon, Ji-In;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.2
    • /
    • pp.45-50
    • /
    • 2012
  • The flow characteristics in a vaneless diffuser with a backswept radial impeller have been experimentally investigated according to the variation of discharge flow rate. Particle image velocimetry(PIV) system was applied to measure velocity fields with several operating conditions and on some diffuser horizontal planes. Pressure transducers were installed on hub wall of the diffuser in order to analyze the pressure fluctuations and their corresponding velocity fields. The results show that the location of the main flow center moves from the hub to the shroud side as the flow rate decreases, and the reverse flow is locally generated on the hub side.