• 제목/요약/키워드: Fluid Management

검색결과 513건 처리시간 0.024초

Role of Catheter's Position for Final Results in Intrathecal Drug Delivery. Analysis Based on CSF Dynamics and Specific Drugs Profiles

  • De Andres, Jose;Perotti, Luciano;Villanueva, Vicente;Asensio Samper, Juan Marcos;Fabregat-Cid, Gustavo
    • The Korean Journal of Pain
    • /
    • 제26권4호
    • /
    • pp.336-346
    • /
    • 2013
  • Intrathecal drug delivery is an effective and safe option for the treatment of chronic pathology refractory to conventional pain therapies. Typical intrathecal administered drugs are opioids, baclofen, local anesthetics and adjuvant medications. Although knowledge about mechanisms of action of intrathecal drugs are every day more clear many doubt remain respect the correct location of intrathecal catheter in order to achieve the best therapeutic result. We analyze the factors that can affect drug distribution within the cerebrospinal fluid. Three categories of variables were identified: drug features, cerebrospinal fluid (CSF) dynamics and patients features. First category includes physicochemical properties and pharmacological features of intrathecal administered drugs with special attention to drug lipophilicity. In the second category, the variables in CSF flow, are considered that can modify the drug distribution within the CSF with special attention to the new theories of liquoral circulation. Last category try to explain inter-individual difference in baclofen response with difference that are specific for each patients such as the anatomical area to treat, patient posture or reaction to inflammatory stimulus. We conclude that a comprehensive evaluation of the patients, including imaging techniques to study the anatomy and physiology of intrathecal environment and CSF dynamics, could become essential in the future to the purpose of optimize the clinical outcome of intrathecal therapy.

함정 수직발사대 화염처리장치 형상에 따른 유동특성 연구 (Design Study on the Flow Characteristics of a Gas Management System for a Vertical Launching System)

  • 양영록
    • 한국군사과학기술학회지
    • /
    • 제16권5호
    • /
    • pp.712-717
    • /
    • 2013
  • The gas management system for a vertical launching system must be safely managed within a ship. The plenum and uptake are capable of containing and surviving a full-burning restrained firing without loss of gas management integrity. To secure the safety, the pressure characteristics with a supersonic under-expanded jet on a gas management system are numerically investigated using computational fluid dynamics. The results of present analysis and the preliminary design of the gas management system are described in this paper.

전산유체해석(CFD) 모의를 이용한 다공형 스크류 노즐 입수관이 적용된 물탱크 내부의 사류구역 최소화에 대한 유동특성 (Fluid Flow Characteristics for Minimizing the Area of Rapid Flow Inside the Water Tank to which the Multiple Hoe Screw Nozzle Incurrent Canal is Applied, by Using the Computational Fluid Dynamics (CFD) Simulation)

  • 송준혁;권종우;최종웅;왕창근
    • 대한환경공학회지
    • /
    • 제37권1호
    • /
    • pp.23-33
    • /
    • 2015
  • 본 연구는 물탱크 내부의 사류구역 최소화에 목적을 두고 진행하였으며 입수관의 형태를 개선하여 물탱크 내부에서 발생하는 유동특성을 전산유체역학(Computational Fluid Dynamics, CFD)모사 기법을 이용하여 분석 하였다. 기존에 물탱크에 사용되던 자유낙하 방식의 입수관을 다공형 스크류 노즐 입수관으로 개선하고 유동 특성을 분석한 결과 노즐 안에 스크류 날개가 설치된 경우 유동흐름의 폭이 넓게 분사 되었으며 원통형 물탱크 내부에서도 넓은 유동 흐름이 나타났다. 또한 사각형 물탱크에 다공형 스크류 노즐 입수관이 1개 설치되어 있을 경우와 2개 설치되어있을 경우의 유동해석과 추적자모의를 수행하였으며 그 결과 입수관을 2개 설치할 경우 MODAL, MORILL index값이 1에 가깝게 나타나 Plug Flow 특성에 근접하단 결과를 얻을 수 있었다.

Analysis of a 2-Unit Standby Redundant System of Reparable 3-State Devices

  • Park, Young Taek
    • 품질경영학회지
    • /
    • 제10권1호
    • /
    • pp.13-15
    • /
    • 1982
  • A device is said to have three states if it has one good state and two mutually exclusive failure modes ; e. g., in one failure mode, it operates when it should not, in the other it doesn't operate when it Should. Some examples of such device include a fluid flow valve, an automatic machine, and an explosive. A Markov model is developed to obtain the availability Function of a 2-unit standby redundant system of such devices.

  • PDF

Pediatric Kidney Transplantation

  • Lee, Yeon Hee;Kang, Hee Gyung
    • Childhood Kidney Diseases
    • /
    • 제25권1호
    • /
    • pp.8-13
    • /
    • 2021
  • Pediatric kidney transplantation is the best option since it can achieve near normal glomerular filtration rate, adequate fluid balance, and autonomic endocrine function of the kidney in end-stage kidney disease. However, pediatric kidney transplantation is difficult because children are developing and growing, management and complications of pediatric kidney transplantation are different from those of adults. This review covers the current status of pediatric kidney transplantation in Korea, key considerations that must be taken before kidney transplantation in children, and management strategy of immunosuppression and common complications.

연구개발 특성을 고려한 품질경영 모형 (A Quality Management Model Contingent to R&D Characteristics)

  • 윤재욱
    • 대한산업공학회지
    • /
    • 제43권2호
    • /
    • pp.90-99
    • /
    • 2017
  • As the importance of R&D has increased, there have been various efforts to apply the quality management principles and tools to R&D activities in order to manage them effectively. The R&D sector differs from other value chains, so it may be difficult to apply quality management without proper considerations of R&D characteristics. This study describes the characteristics of R&D as high uncertainty and risk, diversity of R&D types, project-based activities, importance of strategic goals and business models, and importance of intangible assets. Three well accepted R&D quality management models are reviewed and implications for quality management and R&D characteristics are summarized. Based on these findings, the management targets of R&D quality management are classified into management level (organization, project) and management focus (process, output), and the contexts of R&D quality management are classified into R&D type (research, development) and market/customer requirement clarity (fluid, specific), and appropriate R&D quality management activities in each situations have been suggested.

합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현 (Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection)

  • 박노진;유동근;유홍근
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

광섬유-탐침과 근적외선(NIR) 분광기를 이용한 약제분말 유동층 혼합공정의 인라인 모니터링 연구 (In-line Monitoring of Fluid-Bed Blending Process for Pharmaceutical Powders using Fiber Optics Probe and NIR Spectroscopy)

  • 박초롱;김아영;이민정;이혜은;서다영;신상문;최용선;권병수;방규호;강호경;김종국;이상길;최광진
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권1호
    • /
    • pp.29-36
    • /
    • 2009
  • Since the quality of final products is significantly affected by the homogeneity of powder mixture, the powder blending process has been regarded as one of the critical pharmaceutical unit processes, especially for solid dosage forms. Accordingly, the monitoring to determine a blending process' end-point based on a faster and more accurate in-line/on-line analysis has attracted enormous attentions recently. Among various analytical tools, NIR (near-infrared) spectroscopy has been extensively studied for PAT (process analytical technology) system due to its many advantages. In this study, NIR spectroscopy was employed with an optical fiber probe for the in-line monitoring of fluid-bed blending process. The position of the probe, the ratio of binary powder mixture, the powder size differential and the back-flush period of the shaking bag were examined as principal process parameters. During the blending process of lactose and mannitol powders, NIR spectra were collected, corrected, calibrated and analyzed using MSC and PLS method, respectively. The probe position was optimized. A reasonable end-point was predicted as 1,500 seconds based on 5% RSD value. As a consequence, it was demonstrated that the blending process using a fluid-bed processor has several advantages over other methods, and the application of NIRS with an optical fiber probe as PAT system for a fluid-bed blending process could be high feasible.

소뇌 종양 적출 후 두개강 내 발생한 난치성 뇌척수액 고임의 치험례 (Management of Intractable Cerebrospinal Fluid Collection after Cerebellar Tumor Resection: A Case Report)

  • 라은영;오득영;김혜영;이중호;문석호;서제원;이종원;안상태
    • 대한두개안면성형외과학회지
    • /
    • 제11권2호
    • /
    • pp.95-98
    • /
    • 2010
  • Purpose: CSF (Cerebrospinal fluid) leakage is the most common complication of neurosurgery. Early management with conservative care or surgery must be followed appropriately due to the increased risk of lethal complications, such as meningitis. We report a case of intractable CSF leakage that occurred after a cerebellar tumor resection, which was treated successfully. Methods: A 53-year old male consulted our department for continuous CSF leakage for 3 months after having received conservative care and lumbar drainage. CSF collection was observed in the dead space of the posterior fossa after a cerebellar tumor resection and postoperative radiotherapy. Using a free latissimus dorsi muscle flap, the dead space within the skull was filled and the defects were covered successfully. Results: At 6 weeks after surgery, the follow-up MRI and CT revealed proper coverage and filling in the area where cerebellar tumor had been removed. No CSF leakage was observed at the postoperative 3 month follow-up. Conclusion: Recurrent CSF leakage was treated after cerebellar tumor resection with a relatively satisfactory result. In terms of the patient's treatment, much better results can be achieved by performing dead space filling using a flap with a sufficient size, in addition to coverage of the defects of the dura.

The Incidence and Management of Dural Tears and Cerebrospinal Fluid Leakage during Corrective Osteotomy for Ankylosing Spondylitis with Kyphotic Deformity

  • Jo, Dae-Jean;Kim, Ki-Tack;Lee, Sang-Hun;Cho, Myung-Guk;Seo, Eun-Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권1호
    • /
    • pp.60-64
    • /
    • 2015
  • Objective : To present the incidence and management of dural tears and cerebrospinal fluid leakage during corrective osteotomy [Pedicle Subtraction Osteotomy (PSO) or Smith-Petersen Osteotomy (SPO)] for ankylosing spondylitis with kyphotic deformity. Methods : A retrospective study was performed for ankylosing spondylitis patients with fixed sagittal imbalance, who had undergone corrective osteotomy (PSO or SPO) at lumbar level. 87 patients were included in this study. 55 patients underwent PSO, 32 patients underwent SPO. The mean age of the patients at the time of surgery was 41.7 years (21-70 years). Of the 87 patients, 15 patients had intraoperative dural tears. Results : The overall incidence of dural tears was 17.2%. The incidence of dural tears during PSO was 20.0%, SPO was 12.5%. There was significant difference in the incidence of dural tears based on surgical procedures ( PSO vs. SPO) (p<0.05). The dural tears ranged in size from 12 to $221mm^2$. A nine of 15 patients had the relatively small dural tears, underwent direct repair via watertight closure. The remaining 6 patients had the large dural tears, consequently direct repair was impossible. The large dural tears were repaired with an on-lay graft of muscle, fascia or fat harvested from the adjacent operation site. All patients had a successful repair with no patient requiring reoperation for the cerebrospinal fluid leak. Conclusion : The overall incidence of dural tears during PSO or SPO for ankylosing spondylitis with kyphotic deformity was 17.2%. The risk factor of dural tears was complexity of surgery. All dural tears were repaired primarily using direct suture, muscle, fascia or fat graft.