• Title/Summary/Keyword: Fluid Management

Search Result 513, Processing Time 0.023 seconds

A Study on Hybrid Characteristics of Public Space in Contemporary Cities Reinterpreted by the Idea of Liminal Space (역공간(Liminal Space) 개념으로 해석한 현대도시 공공공간의 혼성적 특성에 관한 연구)

  • Zoh, Kyung-Jin;Han, So-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.4
    • /
    • pp.49-59
    • /
    • 2011
  • This study is a reinterpretation of characteristics of public space in contemporary cities with a view to liminal space. The conditions of pubic space now cannot be captured through the existing discourses of publicness, and public space. The basic premise of the study is that the idea of liminal space or liminality is useful to grasp the fluid and hybrid attribute of public space in contemporary cities. Liminal space, originally from anthropological studies, is the intermingled stage between two realms and the sustained period of the ritual. The idea has been widely used for various cultural phenomenon and spatial experiences. A literature review on public space and liminal space was carried out. Cases pertaining to public space with a view to liminal space were examined and discussed in detail. Through the careful reading of several public spaces with an angle toward liminal space, the new perspective toward public space will be drawn out. First, we need to emphasize the fluid spectrum of public space rather than the serial stage such as the public, the semi-public, the semi-private, and the private. Second, the idea will contribute to understanding the flexible state depending upon time. What we can learn from case studies is the volatile characteristics in public space as a common phenomenon support its vitality. This interpretation will contribute to the perception of a new horizon of public space. The nature of public space is unpredictable and free. In reality, the spectrum of public space will expand and fluctuate. Ironically, public space can be vitalized through enhancing and activating the private space. The intimate and complicated interface between the two realms is a key issue. The boundary of public space might be redefined to embrace the flexible the fragile nature of changing public space. These research implications will guide the thoughtful design and management of pubic space.

Improvement of Energy Efficiency of Plants Factory by Arranging Air Circulation Fan and Air Flow Control Based on CFD (CFD 기반의 순환 팬 배치 및 유속조절에 의한 식물공장의 에너지 효율 향상)

  • Moon, Seung-Mi;Kwon, Sook-Youn;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2015
  • As information technology fusion is accelerated, the researches to improve the quality and productivity of crops inside a plant factory actively progress. Advanced growth environment management technology that can provide thermal environment and air flow suited to the growth of crops and considering the characteristics inside a facility is necessary to maximize productivity inside a plant factory. Currently running plant factories are designed to rely on experience or personal judgment; hence, design and operation technology specific to plant factories are not established, inherently producing problems such as uneven crop production due to the deviation of temperature and air flow and additional increases in energy consumption after prolonged cultivation. The optimization process has to be set up in advance for the arrangement of air flow devices and operation technology using computational fluid dynamics (CFD) during the design stage of a facility for plant factories to resolve the problems. In this study, the optimum arrangement and air flow of air circulation fans were investigated to save energy while minimizing temperature deviation at each point inside a plant factory using CFD. The condition for simulation was categorized into a total of 12 types according to installation location, quantity, and air flow changes in air circulation fans. Also, the variables of boundary conditions for simulation were set in the same level. The analysis results for each case showed that an average temperature of 296.33K matching with a set temperature and average air flow velocity of 0.51m/s suiting plant growth were well-maintained under Case 4 condition wherein two sets of air circulation fans were installed at the upper part of plant cultivation beds. Further, control of air circulation fan set under Case D yielded the most excellent results from Case D-3 conditions wherein air velocity at the outlet was adjusted to 2.9m/s.

Effects of Intracavitary Urokinase Instillation in Complicated Pleural Effusion (합병성 흉막 삼출에 대한 국소적 Urokinase 주입치료 효과에 관한 연구)

  • Sohn, Dong-Hyun;Yoon, Su-Mi;Kim, Chung-Mi;Park, Ik-Soo;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.3
    • /
    • pp.357-364
    • /
    • 2000
  • Background : Complicated exudative pleural fluid collections have traditionally been treated by either closed tube thoracostomy drainage or by open surgical drainage. Complete drainage is important in order to control pleural sepsis, restore pulmonary function, and entrapment. Recently intracavitary fibrinolytic therapy has been advocated as a method to facillitate drainage of complicated exudative pleural effusion and to allow enzymatic debridemant of the restrictive fibrinous sheets covering the pleural surface. The purpose of this study is to prospectively evaluate the effects of image-guided catheter drainage with high dose urokinase(UK) instillation in the treatment of complicated pleural effusions. Patients : Twenty complicated pleural effusion patients that poorly respond to image-guided drainage were allocated to receive UK. There were 8 pneumonia and 12 tuberculosis. Methods : Drugs were diluted in 250 mL normal saline and were infused intrapleurally through the chest tube or pig-tail catheter in a daily dose of 250,000 IU of UK. Response was assessed by clinical outcome, fluid drainage, chest radiography, pleural ultrasound and/or computed tomography. Results : The mean UK instillation time was $1.63{\pm}0.10$. The mean volume drained UK instillation was $381.3{\pm}314.4\;mL$, and post-UK was $321.6{\pm}489.5\;mL$. The follow up duration after UK therapy was mean $212.9{\pm}194.5$ days. We had successful results in 19 cases (95.0%). There were 12 pleural thickenings (60.0%), 2 markedly decreased effusions (10.0%) and 5 cases of no thickening or effusion. There was recurrence after treatment in only one patient(5%) with complicated pleural effusiondue to tuberculosis. Conclusions : Image-guided drainage with high dose UK instillation (250,000 U/day) in complicated pleural effusion is a safe and more effective method than closed thoracostomy drainage. And this management, in turn, can obviate surgery in most cases.

  • PDF

Clinical Usefulness of Serum Uric Acid in Gastroenteritis Patients with lJehydration (급성장염으로 인한 탈수 환아에서 혈청 요산의 염상적 유용성)

  • Song, Jun Ho;Jang, Myung Wan;Yoo, Hwang Jae;Kim, Cheol Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2006
  • Purpose: The estimation of fluid deficit is crucial to the proper management of dehydrated children. Without well-documented serial weights on the same scale, the estimation of any given child's fluid deficit is imprecise and dependent largely on subjective clinical criteria. Despite the abundance of literature on clinical and laboratory evaluation of dehydration, few studies have focused on serum uric acid. So, we examined the usefulness of scrum uric acid in gastroenteritis patients with dehydration. Methods: Medical records of 90 gastroenteritis patients were retrospectively reviewed. By the body weight loss, we classified patients with mild, moderate, and severe dehydration groups. We studied the relevance of laboratory data (BUN, creatinine, serum bicarbonate, glucose, urine specific gravity, and uric acid) with dehydration. Results: 54 children (60%) were dehydrated mildly, 24 (26%) dehydrated and moderately, and 12 (14%) dehydrated severely. Statistically significant differences in BUN, creatinine, serum bicarbonate, glucose, and urine specific gravity could not be observed. But there was significant relationship between uric acid and the degree of dehydration. Data analysis suggested that the level of 7.0 mg/dL is the best cut-off value for predicting the development of moderate or severe dehydration. At this cut-off value, the sensitivity and specificity were 66.6% and 87.1%. Conclusion: Our study supports that the measurement of serum uric acid with traditional scale is useful for predicting the development of dehydration. But, in order 10 be used as the indicator for proper treatment at an earlier stage, further validation about serum uric acid is necessary.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

Thermal Behavior and Leaf Temperature in a High Pressure Sodium Lamp Supplemented Greenhouse (고압나트륨등 보광 온실의 열적 거동 및 엽온 분석)

  • Seungri Yoon;Jin Hyun Kim;Minju Shin;Dongpil Kim;Ji Wong Bang;Ho Jeong Jeong;Tae In Ahn
    • Journal of Bio-Environment Control
    • /
    • v.32 no.1
    • /
    • pp.48-56
    • /
    • 2023
  • High-pressure sodium (HPS) lamps have been widely used as a useful supplemental light source to emit sufficient photosynthetically active radiation and provide a radiant heat, which contribute the heat requirement in greenhouses. The objective of this study to analyze the thermal characteristics of HPS lamp and thermal behavior in supplemented greenhouse, and evaluate the performance of a horizontal leaf temperature of sweet pepper plants using computational fluid dynamics (CFD) simulation. We simulated horizontal leaf temperature on upper canopy according to three growth stage scenarios, which represented 1.0, 1.6, and 2.2 plant height, respectively. We also measured vertical leaf and air temperature accompanied by heat generation of HPS lamps. There was large leaf to air temperature differential due to non-uniformity in temperature. In our numerical calculation, thermal energy of HPS lamps contributed of 50.1% the total heat requirement on Dec. 2022. The CFD model was validated by comparing measured and simulated data at the same operating condition. Mean absolute error and root mean square error were below 0.5, which means the CFD simulation values were highly accurate. Our result about vertical leaf and air temperature can be used in decision making for efficient thermal energy management and crop growth.

Intrapleural Doxycycline and Bleomycin in the Management of Malignant Pleural Effusions : A Randomized Study (악성 흉막삼출액에서 Doxycycline과 Bleomycin을 이용한 흉막경화요법의 치료효과 비교)

  • Oh, Won Sup;Choi, Jin;Kim, Yong Su;Do, Yong Hee;Jang, Tae Won;Jung, Maan Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.85-92
    • /
    • 1997
  • Background : The standard treatment of recurrent, symptomatic malignant pleural effusion is intrapleural instillation of a chemical agent in an attempt to achieve a sterile inflammation and pleurodesis. There are many drugs used as pleural sclerosing agents, but the efficiency and side effects are different. The present study was undertaken to compare the commonly used drugs, doxycycline and bleomycin. Methods : Thirty-four patients with malignant pleural effusion who needed repeated thoracentesis were randomized to receive treatment with intrapleural instillation of doxycycline or bleomycin Fluid volumes before and after pleurodesis, drainge time, and side effects were analyzed, and the response to treatment was evaluated by clinical examination and chest radiography during admission in the hospital. Also median survival rime were evaluated according to the responses. Results : The response rate was higher in the patients receiving doxycycline than in those receiving bleomycin (87.5% vs 50.0%, p=0.02), and fever, nausea and vomiting were more common in the patients receiving bleomycin. The median survival time was significantly longer in the patients who responded to the sclerotherapy regardless of sclerosing agents. Conclusions : Chemical pleurodesis with doxycycline or bleomycin could reduce or stop pleural effusions and prolong the median survival rimes in these patients. Doxycycline appeared to be more efficient as sclerosing agent than bleomycin in the short-term follow-up periods. But a prospective study with a larger number of patients is warranted.

  • PDF

A Study on the Trends of Virtual Reality Application Technology for Agricultural Education (가상현실 응용기술의 동향 분석을 통한 국내 시설농업의 교육용 가상현실 활용방안 고찰)

  • Kim, Jun-Gyu;Lee, In-bok;Yoon, Kwang-Sik;Ha, Tae-hwan;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sang-yeon
    • Journal of Bio-Environment Control
    • /
    • v.27 no.2
    • /
    • pp.147-157
    • /
    • 2018
  • With the rapid development of the 4th industrial revolution, the large-sized facilities of agriculture have been developed with high-technologies. However, it is difficult to maintain the optimum environment in large-sized facilities. Although it is essential to control micro-climate properly in large-sized facilities, there are a lot of problems to utilize high-technologies and equipment because of insufficient education for farmers. Most farms have limitations to access to their farm because of prevention of epidemics, exposure of management know-how, and so on. Especially, it is difficult to understand internal environmental factors (airflow, temperature, humidity, etc.) for farmers because these factors are invisible. Recently, Virtual reality technology which allows users to experience various phenomena directly is attracting attention. Virtual reality is very useful technology to visualize airflow and temperature distribution and so on. However, there is no cases applied this technology to agricultural facilities. In this study, research trends of virtual reality in various fields were investigated. In particular, the limitation and possibility of virtual reality technology were analyzed for educating farmers. Finally, the development of virtual reality contents for smart-farm facility were suggested.

Characteristics of organic pollutants in discharged industrial waste in Korea - Focuse on metallic and plastic manufacturing processes and wastewater treatment plants - (국내 사업장 폐기물 중 유기오염물질의 배출특성 연구 - 금속과 플라스틱 제조공정 및 폐수처리시설 중심으로 -)

  • Yeon, Jin-Mo;Kang, Young-Yeul;Kim, Woo-Il;Shin, Sun-Kyoung;Jeong, Seong-Kyeong;Cho, Yoon-A;Kim, Na;Kim, Min-Sun
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.421-428
    • /
    • 2012
  • In this study, PCDD/PCDFs, PAHs and PCBs in wastes from metal, plastic and wastewater treatment facilities were analyzed. The concentrations of PCDD/PCDFs ranged from 7.37~432.20 ng-TEQ/kg in fly ash, 0.51~855.01 ng-TEQ/kg in incinerated ash and 0.37~385.81 ng-TEQ/kg in dust. Dioxin content was lower, compared to data in foreign countries. PAHs concentration was in the range of 0.0075~2.9225 mg/kg for process sludge and 0.0035~1.6716 mg/kg for wastewater sludge, which satisfied all of the two standards (Nap, Ant, B(a)F:4/0.8, Phen, B(a)A:5/1, Flt:10/2.5, B(a)P:4.5/0.9) of the Marine Environment Management Act. PAHs concentration in process sludge and wastewater sludge were slightly lower than those abroad. According to the analysis of seven types of PCBs (in comparison with the first standard, 0.15 mg/kg), concentration was found in the range of 0.0~0.65 mg/kg, while PCB-52, PCB-101, PCB-138, PCB-153 and PCB-180 isomers were detected in excessive value in some machine oil and hydraulic fluid.

Streptococcal Toxic Shock Syndrome Occurred during Postoperative Radiotherapy in a Cancer Patient with Preexisting Lymphedema and Chronic Illness -Case Report- (수술 후 림프부종과 만성질환을 동반한 종양 환자에서 방사선치료 기간 동안 발생한 연쇄구균독소충격증후군 예)

  • Jang, Ji-Young;Oh, Yoon-Kyeong;Kim, Dong-Min
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.317-321
    • /
    • 2006
  • A case is reported of a man with malignant fibrous histiocytoma (MFH) in right thigh who developed streptococcal toxic shock syndrome (STSS) during postoperative radiotherapy. Before radiotherapy, a patient complained wax and wane lymphedema following wide excision of tumor mass which was confirmed as MFH. He took some nonsteroidal antiinflammatory drug (NSAID) for about one month. He suffered preexisting hepatitis C virus (HCV) infection, diabetes and well-controlled hypertension. The patient received conventional radiotherapy to right thigh with a total dose of 32.4 Gy at 1.8 Gy per day. At last radiotherapy fraction, cutaneous erythematous inflammation was suddenly developed at his affected thigh. At that time, he also complained of oliguria, fever and chills. The patient was consulted to internal medicine for adequate evaluation and management. The patient was diagnosed as suggested septic shock and admitted without delay. At admission, he showed hypotension, oliguria, constipation, abnormal renal and liver function. As a result of blood culture, Streptococcus pyogenes was detected. The patient was diagnosed to STSS. He was treated with adequate intravenous antibiotics and fluid support. STSS is one of oncologic emergencies and requires immediate medical intervention to prevent loss of life. In this patient, underlying HCV infection, postoperative lymphedema, prolonged NSAID medication, and radiotherapy may have been multiple precipitating factors of STSS.