• Title/Summary/Keyword: Fluid Management

Search Result 513, Processing Time 0.027 seconds

Improvement of Capturing Velocity in the Fume Hood using Computational Fluid Dynamics(I) - Uniform flow (전산유체역학을 이용한 흄후드 제어유속 개선(I) - 균일류)

  • Jung, Jong-Hyeon;Lee, Sang-Woon;Lee, Sang-Man;Shon, Byung-Hyun;Lee, Jung-Hee;Jung, Yu-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.962-969
    • /
    • 2013
  • This study used Computational Fluid Dynamics(CFD) to assess the properties of the air current inflow and the flow velocity distribution in the fume hood. In order to verify the effect of improvement, it was also predicted the characteristics of the flow pattern in case the hood face is structurally improved. The assessment of the capture velocity with the existing fume hood confirmed maximum 23 to 30% difference as compared to the root mean square (RMS). And the hood face showed great difference in flow velocity, with the flow velocity in the upper part is 58 to 68% faster than that in the lower part of the hood. So, as a result of the improvement of the hood designed to maintain a steady exhaust at the hood face (that is, installing a baffle on the inner wall and designing the slot type face), a difference of maximum 7% as compared to RMS appeared while maximum 12% differentiation in flow velocity through sections was predicted, showing mitigation of much of the difference in control velocity as compared to the previous structure.

Optimum Management of Greenhouse Environment by the Shading Coat and Two-fluid Fogging System in Summer Season (차광제와 이류체 포그시스템을 이용한 고온기 시설내 환경관리)

  • Kim, Sung Eun;Lee, Jae Eun;Lee, Sang Don;Kim, Hak Sun;Chun, Hee;Jeong, Woo Ri;Lee, Moon Haeng;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.24 no.1
    • /
    • pp.34-38
    • /
    • 2015
  • This research was conducted to establish efficient methods to overcome high temperature and low humidity with light selective shading agent and two-fluid fogging system in greenhouses in hot season. There were four experimental treatments; not treated (Non), fogging by two-fluid fogging system (Fog), spraying onto the greenhouse surface with shading coating agent (Coat), and using fogging and coating together (F&C). The amount of solar radiation entered into the greenhouses was higher in Non, and then Fog, Coat, and F&C in descending order. Fog was more efficient to lower the air temperature and also raise relative humidity than Coat treatment. The crop temperature was about $6^{\circ}C$ higher in Control than the other treatments. F&C revealed as the most efficient method to control the environment inside the greenhouse, but fogging system seemed to be more economic. In stand-alone greenhouses spraying coating agent may be the appropriate choice because of their structural limitations, mainly eave height.

Type I immune-mediated polyarthritis with azathioprine therapy in a Shih-tzu dog

  • Jung, Dong-In;Park, Chul;Kang, Byeong-Teck;Kim, Ju-Won;Kim, Ha-Jung;Lim, Chae-Young;Ko, Ki-Jin;Lee, So-Young;Cho, Sue-Kyung;GU, Su-Hyun;Heo, Ra-Young;Park, Hyo-Jin;Jeon, Hyo-Won;Kim, Jung-Hyun;Han, Sung-Kuk;Yoon, Ah-Ram;Sung, Ju-Heon;Yoo, Jong-Hyun;Park, Hee-Myung
    • Korean Journal of Veterinary Research
    • /
    • v.46 no.4
    • /
    • pp.395-398
    • /
    • 2006
  • A 2-month-old female Shih-tzu dog was referred because of lameness, exercise intolerance, depression, elbow and stifle joint swelling. Physical examination, complete blood counts, serum-chemistry, radiography, synovial fluid analysis, antinuclear antibody test, and rheumatoid factor measurement were initiated. On radiography, soft tissue swelling of elbow and stifle joints without erosiveness were founded. The results of synovial fluid analysis revealed severe neutrophilic pleocytosis (nondegenerative), decreased viscosity, increased turbidity, positive on mucin-clot test, and negative on bacterial culture. The results of rheumatoid factor measurement and antinuclear antibody test were negative and below 1 : 40, respectively. Based on all tests, we diagnosed this case as juvenile onset type I immune-mediated polyarthritis. Azathioprine (1 mg/kg body weight, per os q 24 h, for 4 weeks) was then administered and clinical signs improved gradually. Four weeks after azathioprine administration, clinical signs were disappeared. This report describes the clinical findings, imaging characteristics, synovial fluid findings, and other laboratory results of type I immune-mediated polyarthritis and successful management with azathioprine therapy.

A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter(II) -Structural Improvement (반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(II) -구조개선을 중심으로)

  • Kim, Jin-Uk;Jung, Yu-Jin;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.985-992
    • /
    • 2011
  • The 3D computational fluid dynamics (CFD) was performed in relation to the internal fluid characteristics and flow distribution for the development of the most optimal model in the complex post-disposal device. As it is expected that a channeling (drift) would be made by the semi-dry reactor due to the large difference in the flow distribution by the compartment in the bag filter, a structural improvement should be urgently made for more uniformed flow distribution in the bag filter. Three types of modifications such as i) changing the plenum shape, ii) orifice install in the exit part of cleaned gas, iii) increasing the plenum number were established. From the results of computational fluid dynamics, it was revealed that the changing of plenum shape and orifice install in the exit part of cleaned gas was more reasonable than the increasing the plenum number because of the difficulties of retrofit. The complex post-disposal device, modified and supplemented with this analysis, integrated the semi-dry reactor and the bag filter in a single body, so it follows that the improvement can make the device compact, save the installation area, save the operation fee, and management more convenient.

Environmental Prediction in Greenhouse According to Modified Greenhouse Structure and Heat Exchanger Location for Efficient Thermal Energy Management (효율적인 열에너지 관리를 위한 온실 형상 및 열 교환 장치 위치 개선에 따른 온실 내부 환경 예측)

  • Jeong, In Seon;Lee, Chung Geon;Cho, La Hoon;Park, Sun Yong;Kim, Seok Jun;Kim, Dae Hyun;Oh, Jae-Heun
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.278-286
    • /
    • 2021
  • In this study, based on the Computational Fluid Dynamics (CFD) simulation model developed through previous study, inner environmenct of the modified glass greenhouse was predicted. Also, suggested the optimal shape of the greenhouse and location of the heat exchangers for heat energy management of the greenhouse using the developed model. For efficient heating energy management, the glass greenhouse was modified by changing the cross-section design and the location of the heat exchanger. The optimal cross-section design was selected based on the cross-section design standard of Republic of Korea's glass greenhouse, and the Fan Coil Unit(FCU) and the radiating pipe were re-positioned based on "Standard of greenhouse environment design" to enhance energy saving efficiency. The simulation analysis was performed to predict the inner temperature distribution and heat transfer with the modified greenhouse structure using the developed inner environment prediction model. As a result of simulation, the mean temperature and uniformity of the modified greenhouse were 0.65℃, 0.75%p higher than those of the control greenhouse, respectively. Also, the maximum deviation decreased by an average of 0.25℃. And the mean age of air was 18 sec. lower than that of the control greenhouse. It was confirmed that efficient heating energy management was possible in the modified greenhouse, when considered the temperature uniformity and the ventilation performance.

A Study on Development of a GIS based Post-processing System of the EFDC Model for Supporting Water Quality Management (수질관리 지원을 위한 GIS기반의 EFDC 모델 후처리 시스템 개발 연구)

  • Lee, Geon Hwi;Kim, Kye Hyun;Park, Yong Gil;Lee, Sung Joo
    • Spatial Information Research
    • /
    • v.22 no.4
    • /
    • pp.39-47
    • /
    • 2014
  • The Yeongsan river estuary has a serious water quality problem due to the water stagnation and it is imperative to predict the changes of water quality for mitigating water pollution. EFDC(Environmental Fluid Dynamics Code) model was mainly utilized to predict the changes of water quality for the estuary. The EFDC modeling normally accompanies the large volume of modeling output. For checking the spatial distribution of the modeling results, post-processing for converting of the output is prerequisite and mainly post-processing program is EFDC_Explorer. However, EFDC_Explorer only shows the spatial distribution of the time series and this doesn't support overlay function with other thematic maps. This means the impossible to the connection analysis with a various GIS data and high dimensional analysis. Therefore, this study aims to develop a post-processing system of a EFDC output to use them as GIS layers. For achieving this purpose, a editing module for main input files, and a module for converting binary format into an ASCII format, and a module for converting it into a layer format to use in a GIS based environment, and a module for visualizing the reconfigured model result efficiently were developed. Using the developed system, result file is possible to automatically convert the GIS based layer and it is possible to utilize for water quality management.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Management of Elderly Patients with Intracranial Aneurysm (고령군 뇌동맥류 환자의 치료)

  • Park, Hyeon Seon;Lee, Jae Whan;Kim, Jin Young;Shin, Yong Sam;Joo, Jin Yang;Huh, Seung Kon;Lee, Kyu Chang
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.786-793
    • /
    • 2000
  • Objectives : A clinical analysis was performed to provide management strategy and to improve management outcome of elderly patients with intracranial aneurysm. Patients and Methods : We reviewed medical records of 746 consecutive patients with intracranial aneurysm who were admitted from July 1991 to December 1996. They were divided into two age groups : elderly(120 patients aged 65 years or older) and non-elderly(626 patients aged 64 years or younger). We investigated the differences between the two groups in clinical characteristics, management outcome and surgical results. Results : Female(80.0%), internal carotid artery aneurysm(48.9%), poor clinical grade(Hunt and Hess Grade IV, V : 39.8%), postoperative subdural fluid collection(38.2%), and postoperative hydrocephalus(39.7%) were more frequent in the elderly patients. There were no significant differences in the incidence of hypertension, multiple aneurysm, unruptured aneurysm, rebleeding, delayed ischemic neurological deficits, postoperative hemorrhage, and low density on the postoperative brain CT scan. In some cases, surgical clipping of ruptured aneurysm could not be performed due to moribund state or refusal of surgery by the elderly patient's family. Both management outcome and surgical results in elderly aneurysm patients at 3 months after rupture were worse than those of the non-elderly group. The most common reason of unfavorable outcome was poor clinical grade in both groups, while serious medical illness causing unfavorable outcome was more common in the elderly group. Conclusion : Surgical treatment of a ruptured aneurysm should not be avoided in elderly patient solely on the basis of advanced age. If the patients are in good clinical grade, early aneurysm surgery followed by early ambulation should be recommended. Further improvements in outcome may be achieved by thorough knowledge of poor resilience of brain, CSF flow dynamics, and diminished cardiopulmonary reserve in elderly patients with intracranial aneurysm.

  • PDF

Implementation and Application of the EDISON platform's integrated file management service (EDISON 플랫폼의 통합 파일관리 서비스 구현 및 적용)

  • Ma, Jin;Seo, Jerry;Ruth-Lee, Jong suk;Park, Min jae
    • Journal of Internet Computing and Services
    • /
    • v.17 no.6
    • /
    • pp.71-79
    • /
    • 2016
  • As computer technology continues to evolve, the Computational Sciences utilized in Physics, Chemistry, Materials Science, and Life Sciences have been attracting more attention. In Korea, to compensate for the drawbacks in Computational Science, students and researchers have been using the EDISON platform. The EDISON platform provides a web portal service for education and research and an environment for addressing complex issues involving five fields, e.g., Computational Fluid Dynamics (CFD), Nanophysics, Computational Chemistry, Structural Dynamics, and Computational Design. As the platform and user scale increase beyond service provision, the need for efficient operation of its currently running data management system is on the rise. In this study, we resolve the data synchronization issues between the existing EDISON platform and web portal. As the EDISON platform is integrated with the web portal, a file management service is implemented to integrate the management of user data and files, which ultimately improves the overall efficiency of file management.

A Study for the Present Conditions and the Service Satisfaction with Hospital Home Care Service (병원가정간호사업 운영 현황 및 서비스 만족도에 관한 연구)

  • Hong, Chun-Sil;Oh, Kyong-Ok;Park, Mi-Young;Sim, Hee-Sook;Cha, Young-Nam
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.8 no.2
    • /
    • pp.121-134
    • /
    • 2001
  • The purpose of this study were to analyze the home care services and to evaluate the client's satisfaction with the home care services provided by home care service center in the C hospital. The data were collected by reviewing charts of 128 home care clients who were receiving home care services at C hospital from October 1997 to September 2000. The subjects for satisfaction of home care service were 20 clients from July 10 to September 30, 2000. The tool for measurement of present condition of home care service was developed by the researchers. The satisfactions of the home care services were measured by using the instrument developed by Im(997). The data were analyzed by using the SPSS/PC+. The results of this study were as followings : 1. Majority of the subjects was female(61.7%). The average of age was 63.5 years. The service has been used mostly by the elderly 60 years of age or older(71.1%). The economic level of most of subjects was in middle class(94.5%). 2. Majority of the subject had a cancer(55.4%), following stroke(25.0%). The average duration of disease for the subjects was 31 months. The average time of hospitalization for the subjects was 3.3 times. The duration of hospitalization was 10$\sim$30 days(26.6%), 30$\sim$60 days(23.4%) and above of the 210 days(9.4%). 3. Most of the subjects used his/her doctor (47.7%), as a consultant, following his/her nurse (28.1%), other patients or their family (21.9%). Most of reasons for a consultation were supportive management(Infusion or medication, 60.94%), following tube management(L-tube or T-tube, 25%), Foley catheter management (15.63%) etc. 4. 28 types of nursing diagnoses were used by the home care service. The nursing diagnosis altered nutrition: less than body requirement were used mostly by the home care service, following risk for infection, impaired skin integrity, impaired swallowing, ineffective airway clearance altered comfort: pain, impaired physical mobility. By the human-response pattern, exchanging(63.2%), moving(7.5%), feeling(10.4%), knowing(5.2%), communicating (2.6%), relating(0.5%) perceiving(0.4%) and choosing(0.3%). There were 42 nursing intervention types were performed by the home care service. By the NIC(nursing intervention classification. McCloskey. Bulech. 1996). physiologic: complex (30.3%) was the most, safety(28.3%), behavioral(20.0%), physiologic: basic(10.8%) and health system(1.7%). Observation or assessment was the most nursing intervention performed by the home care service. following IV infusion. vital sign observation. infusion management and fluid-electrolyte balance management. 5. The level of client's satisfaction with provided home care services showed considerably high(2.67/ 3).

  • PDF