• 제목/요약/키워드: Fluid Flow System

검색결과 2,231건 처리시간 0.031초

시스템 에어컨 설치 공간의 실내공기질 특성에 관한 연구 (A Study on Characteristics of Indoor- Air-Quality in Interior Space Equipped with System Air-Conditioner)

  • 이상원;김종민;염승원;조대근;최재붕;김석우
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.304-313
    • /
    • 2008
  • This paper investigates the indoor-air-quality (IAQ) characteristics of the interior space equipped with system air-conditioner. The behaviors of individual variables such as temperature, humidity and concentration of carbon dioxide ($CO_2$) that influence on IAQ of the interior space were characterized under various cooling conditions by numerical and experimental studies. The numerical analysis predicting the temperature behavior of the interior space was conducted, and its results showed a good agreement with the experimental ones. The $CO_2$ concentration and humidity were measured and their time dependent behaviors were monitored and analyzed. From the results, it was found that there existed the differences of the time-dependent behaviors of IAQ variables according to the locations. In addition, it is demonstrated that the large discharge angle of $45^{\circ}$ made the temperature profile more irregular and the high discharge flow of 5.34 m/s produced similar temperature profiles at three different sensing locations. Finally, the humidity of interior space was less sensitive to the changes of the air cooling conditions than the case of temperature and the $CO_2$ concentration increase mainly depended on the number of individuals inside the space.

흡음재 두께가 소화노즐 소음도 저감에 미치는 영향 (Effect of Absorbent Thickness on the Noise Level Reduction of Fire-Extinguishing Nozzle)

  • 김학선;황인주;김윤제
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.99-104
    • /
    • 2019
  • 신속한 화재 진압을 목표로 가스계 소화 시스템에서 소화약제는 일반적으로 섭씨 $21^{\circ}C$에서 약 28 MPa의 고압으로 저장되며, 방출시 감압밸브와 오리피스를 지나면서 약 8 MPa의 압력으로 방출한다. 때문에 방출시 약 140 dB 이상의 소음이 발생하게 되는데, 이로 인하여 hard disk drive (HDD)와 같은 전자 부품들이 손상되기도 한다. 따라서 소음문제는 가스계 소화 시스템에 있어서 중요한 문제점으로 대두되고 있다. 소음문제 해결방안으로는 일반적으로 흡음재를 부착하여 소음을 저감시키는 방안이 있으며, 본 연구에서는 흡음재의 두께를 설계 변수로 선정하여 유동소음을 저감하는 방안을 고찰하였다. 관측점에서의 소음도와 노즐내부 유로에 나타나는 유동특성은 상용 코드인 ANSYS CFX ver. 18.1을 이용하여 수치적으로 계산하여 분석하였다.

Viscoelastic Property of the Brain Assessed With Magnetic Resonance Elastography and Its Association With Glymphatic System in Neurologically Normal Individuals

  • Bio Joo;So Yeon Won;Ralph Sinkus;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • 제24권6호
    • /
    • pp.564-573
    • /
    • 2023
  • Objective: To investigate the feasibility of assessing the viscoelastic properties of the brain using magnetic resonance elastography (MRE) and a novel MRE transducer to determine the relationship between the viscoelastic properties and glymphatic function in neurologically normal individuals. Materials and Methods: This prospective study included 47 neurologically normal individuals aged 23-74 years (male-to-female ratio, 21:26). The MRE was acquired using a gravitational transducer based on a rotational eccentric mass as the driving system. The magnitude of the complex shear modulus |G*| and the phase angle 𝛗 were measured in the centrum semiovale area. To evaluate glymphatic function, the Diffusion Tensor Image Analysis Along the Perivascular Space (DTI-ALPS) method was utilized and the ALPS index was calculated. Univariable and multivariable (variables with P < 0.2 from the univariable analysis) linear regression analyses were performed for |G*| and 𝛗 and included sex, age, normalized white matter hyperintensity (WMH) volume, brain parenchymal volume, and ALPS index as covariates. Results: In the univariable analysis for |G*|, age (P = 0.005), brain parenchymal volume (P = 0.152), normalized WMH volume (P = 0.011), and ALPS index (P = 0.005) were identified as candidates with P < 0.2. In the multivariable analysis, only the ALPS index was independently associated with |G*|, showing a positive relationship (β = 0.300, P = 0.029). For 𝛗, normalized WMH volume (P = 0.128) and ALPS index (P = 0.015) were identified as candidates for multivariable analysis, and only the ALPS index was independently associated with 𝛗 (β = 0.057, P = 0.039). Conclusion: Brain MRE using a gravitational transducer is feasible in neurologically normal individuals over a wide age range. The significant correlation between the viscoelastic properties of the brain and glymphatic function suggests that a more organized or preserved microenvironment of the brain parenchyma is associated with a more unimpeded glymphatic fluid flow.

선박용 SCR 시스템에서 스월형 혼합기의 날개 각도가 유동혼합 및 압력강하에 미치는 영향 (Effect of Vane Angle of Swirl Type Mixer on Flow Mixing and Pressure Drop in Marine Selective Catalytic Reduction Systems)

  • 박태화;성연모;김태경;최철용;김덕줄;최경민
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.443-448
    • /
    • 2015
  • 선박용 질소산화물 저감장치의 혼합영역에서 유동혼합 성능을 개선하기 위해 스월형 혼합기가 개발되었다. 본 연구에서는 스월형 혼합기와 각단의 날개 각도가 조절 가능한 다단 스월형 혼합기가 고려되었다. 두 스월형 혼합기의 최적 날개 각도를 도출하기 위해 날개 각도가 균일지수 및 압력강하에 미치는 영향을 수치해석 기법을 이용하여 조사하였다. 스월형 혼합기에서는 혼합기의 날개 각도를 $10^{\circ}$ 에서 $80^{\circ}$ 까지 변화시킬 때, 최적의 유동혼합 성능은 베인 각도 $30^{\circ}$에서 $60^{\circ}$ 범위에서 나타났으나, 압력강하는 베인 각도 증가에 따라 선형적으로 증가하였다. 반면 다단 스월형 혼합기에서는 각 단의 날개각도를 조절함으로써 압력강하를 낮추면서도 높은 혼합성능의 유지가 가능함을 보였다.

선박용 로터세일 주위의 난류 유동특성에 관한 수치해석적 연구 (Numerical Analysis Study on the Turbulent Flow Characteristics around the Rotor Sail for Vessels)

  • 김정은;조대환;이창용
    • 해양환경안전학회지
    • /
    • 제28권4호
    • /
    • pp.648-656
    • /
    • 2022
  • 국제해사기구(IMO)의 온실가스(GHG) 감축 전략과 같은 환경규제를 강화함에 따라 친환경 선박 및 대체 연료 등 기술 개발이 확대되고 있다. 그의 일환으로 해운사와 조선사를 중심으로 에너지 저감과 풍력 추진 기술을 활용한 선박 추진 기술이 대두되고 있다. 풍력 추진 기술의 확보와 실증 연구를 조선 및 해운 분야에 도입함으로써 친환경 기술을 활용한 고부가가치 시장을 창출할 수 있으며, 운항선박의 연료 소비율을 줄임으로써 연비를 약 6~8 % 정도 향상시켜 GHG의 감축을 기대할 수 있다. 로터 세일(Rotor Sail, RS) 기술은 원형 실린더가 일정한 속도로 회전하여 유체를 통과할 때 실린더의 수직 방향으로 유체역학적 힘을 발생시키는 기술이다. 이를 마그누스 효과(Magnus Effect)라고 하며, 본 연구에서는 선박에 설치된 풍력보조추진 시스템인 RS 주위의 난류 유동특성에 관한 수치해석적 연구를 통하여 추진효율을 높일 수 있는 방안을 제시하고자 하였다. 그래서 RS의 공기 역학적 힘에 영향을 미치는 매개변수로써 속도비(Spin Ratio, SR)와 종횡비(Aspect Ratio, AR) 변화에 따른 양력계수(CL)와 항력계수(CD)를 도출하였고, RS 끝단 플레이트(End Plate, EP) 적용에 따른 RS 주변 유동특성을 비교하였다.

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

연동펌프를 이용한 비료염 공급 관비재배기술 연구 (Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics)

  • 김동억;이공인;김현환;우영회;이운용;강인철
    • 현장농수산연구지
    • /
    • 제17권1호
    • /
    • pp.57-71
    • /
    • 2015
  • 본 연구에서는 산업분야에서 다양하게 이용되고 있는 연동펌프를 농축양액 주입장치로 사용한 관비장치를 개발하고 성능시험을 실시하였으며, 얻어진 결과는 다음과 같다. 튜브 내경별, 회전수별, 롤러수별 유량특성 시험결과 펌프 회전속도가 빨라짐에 따라 유량은 직선적으로 증가하였으며, 튜브 내경이 커질수록 기울기도 커졌으며, 롤러수가 3개일 때가 4개일 때의 유량 보다 더 많은 것으로 나타났다. 또한 튜브재질에 있어서는 복원력이 우수한 재질의 노프렌 튜브에서 유량이 많은 것으로 나타났다. 관비장치의 농축양액 주입위치에 따른 혼삽성능 실험결과 안정화 시간은 농축양액을 공급펌프의 흡입 측에 주입한 경우에는 17초, 공급펌프의 토출 측에 주입한 경우에는 16초 이었으며, EC는 안정화 구간에서 각각 1.42±0.05, 1.39±0.02 dS/m로 나타나 주입위치에 따른 영향은 크지 않은 것으로 판단된다. 측정 센서 설치위치에 따른 안정화시간은 주관에 삽입 설치한 경우에는 17초, 여수관에 설치한 경우에는 27초로 나타나 센서는 주관에 삽입 설치하는 것이 바람직한 것으로 판단된다. EC는 안정화 구간에서 각각 1.43±0.05, 1.45±0.07dS/m의 근소한 차이를 보였다. 시작기의 제어성능 실험결과 제어정밀도가 ±0.05dS/m로 나타나 제어성능이 우수한 것으로 나타났다. 농가 현장시험결과 개발한 관비장치에 의해 재배한 오이가 정상적인 생육을 하는 것으로 나타나 개발한 시험용 장치의 실용화가 이루어진다면 관비재배 농가에서 활용할 수 있을 것으로 판단된다.

다양한 작동유체를 이용한 20 kW급 해양온도차 발전 사이클 성능 분석 (Performance analysis of 20 kW OTEC power cycle using various working fluids)

  • 윤정인;예병효;허정호;김현주;이호생;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권8호
    • /
    • pp.836-842
    • /
    • 2013
  • 본 연구에서는 고효율 20 kW급 해양온도차 발전사이클을 새롭게 제안하고, 발전사이클의 성능이 최대가 되는 작동유체를 선정하기 위해서 단일냉매 15종과 혼합냉매 16종을 적용하여 발전사이클의 성능을 비교 분석하였다. 시스템 효율, 필요 냉매순환량, 그리고 TPP와 같은 인자를 사용하여 발전사이클의 특성을 분석하였다. 우선, 발전사이클의 효율 측면에서는 R32/R152a(87:13)이 가장 높으며, 필요 냉매 순환량은 R717이 가장 낮다. 그리고 논문에서 새롭게 제시한 TPP의 분석 결과에서는 R32/R134a 70:30이 가장 적합한 냉매로 나타났다. 이상의 결과로부터, 각각의 분석인자에 적합한 냉매는 그 목적에 따라서 다르다는 것을 확인할 수 있었다. 따라서 이러한 분석인자에 맞는 냉매의 선정이 필요하다.

농업용 트랙터의 프론트 로더 충격 저감을 위한 유압 회로의 설계 개선 (Improved Design of Hydraulic Circuit of Front-end Loader for Bump Shock Reduction of an Agricultural Tractor)

  • 조봉진;안성욱;이창주;윤영환;이수성;김학진
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권2호
    • /
    • pp.10-18
    • /
    • 2016
  • A front-end loader (FEL) mounted on an agricultural tractor is one of the most commonly used implements to mechanize routine agricultural tasks. When the FEL is used with a loaded bucket, careful operation is required to maintain safety and avoid spillage when the tractor passes a bump because a change in the gravity center of the tractor due to varied loadings can affect the stability of the tractor. Use of a boom suspension system consisting of accumulators and orifice dampers can be instrumental in reducing pitching vibrations while increasing the handling performance of the FEL-mounted tractor. The objective of this research was to reduce bump shocks by adding an orifice and a flow control valve to the original hydraulic circuit composed solely of accumulators. A simulation study was performed using the SimulationX program to investigate the effects of an accumulator and an orifice-throttle damper on bump shocks. Results showed that the peak pressure on a boom cylinder and the vertical acceleration of a bucket were significantly affected by use of both an accumulator and an orifice damper. In a field test conducted with a 75-kW tractor, the peak pressure of the boom cylinder, and the root mean square (RMS) vertical acceleration of the bucket and seat were reduced by on average, 23.0, 42.2, and 44.9% respectively, as compared to those measured with the original accumulator system, showing that an improved design for the accumulator hydraulic circuit can reduce bump shocks. Further studies are needed to design a tractor suspension system that includes the effects of cabin suspension and tires as well as dynamic analysis.

시설하우스 에너지 절감을 위한 열유동 수치 해석 심층 연구 (Indepth Study of Numerical Heat Transfer and Fluid Flow for Energy Saving of Greenhouse)

  • 신미수;김혜숙;최준호;장동순
    • 대한환경공학회지
    • /
    • 제29권4호
    • /
    • pp.466-471
    • /
    • 2007
  • 본 연구의 목적은 시설하우스에 대한 기본적이면서도 중요한 운전 자료를 얻기 위한 것이다. 특히 시설하우스 에너지 절감을 위해 실용적으로 쉽게 적용할 수 있는 방법에 중점을 두었다. 이러한 목적에 의해 하우스내의 온도분포를 평가하기 위한 방법으로 조직적인 수치해석연구를 수행하였다. 이러한 연구에서 고려한 중요한 변수는 시설하우스의 일반적인 형상과 함께 시설하우스내의 열유동을 조절하는 다양한 배플 조건을 가정하였다. 아울러 난방가열시스템의 배관배치에 따른 열유동 특성과 효율을 상호 비교하였다. 이러한 연구의 결과로 얻어진 몇 가지의 유용한 결론을 정리하였다. 특히 시설하우스 천장에서 내린 배플은 최소한의 시설로서 에너지 효율에 실질적인 기여를 할 수 있었으며 또한 난방배관의 구조는 시설하우스내의 균일한 온도 분포을 얻기 위하여 크게 영향을 미치고 있음을 확인하였다. 기타 본연구의 여러 수치해석 결과들은 물리적인 면에서 의미가 있었으며 실용적인 면에서 시설하우스의 최적 운전조건의 설정에 도움이 된다고 판단하였다.