• 제목/요약/키워드: Fluid Distribution

검색결과 1,682건 처리시간 0.022초

Non-uniform Distribution of Magnetic Fluid in Multistage Magnetic Fluid Seals

  • Zhongzhong, Wang;Decai, Li;Jing, Zhou
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.299-305
    • /
    • 2017
  • Magnetic fluid, a new type of magnetic material, is a colloidal liquid constituted of nano-scale ferromagnetic particles suspended in carrier fluid. Magnetic fluid sealing is one of the most successful applications of magnetic fluid. As a new type of seal offering the advantages of no leakage, long life and high reliability, the magnetic fluid seal has been widely utilized under vacuum- and low-pressure-differential conditions. In practical applications, for improved pressure capacity, a multistage sealing structure is always used. However, in engineering applications, a uniform distribution of magnetic fluid under each tooth often cannot be achieved, which problem weakens the overall pressure capacity of the seals. In order to improve the pressure capacity of magnetic fluid seals and broaden their applications, the present study theoretically and experimentally analyzed the degree of non-uniform distribution of multistage magnetic fluid seals. A mathematical model reflecting the relationship between the pressure capacity and the distribution of magnetic fluid under a single tooth was constructed, and a formula showing the relationship between the volume of magnetic fluid and its contact width with the shaft was derived. Furthermore, the relationship of magnetic fluid volume to capacity was analyzed. Thereby, the causes of non-uniform distribution could be verified: injection of magnetic fluid; the assembly of magnetic fluid seals; the change of magnetic fluid silhouette under pressure loading; the magnetic fluid sealing mechanism of pressure transmission, and seal failure. In consideration of these causes, methods to improve the pressure capacity of magnetic fluid seals was devised (and is herein proposed).

배전용 몰드변압기의 온도특성 파악을 위한 열유동해석 (Thermal Fluid Flow Analysis for Temperature Characterization of Mold Transformer in Distribution Power System)

  • 김지호;이정근;이기식;이욱;이향범
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.6-11
    • /
    • 2013
  • In this paper, the temperature characteristics of mold transformer for the distribution power system have been analyzed by using computational fluid dynamics(CFD). The model has been modeled by coil, cores, insulating materials and frames about 3MVA grade mold transformer and analyzed the temperature distribution of the structure with a heat fluid. The fluid, which is incompressible ideal gas, is analyzed as a turbulent flow phenomenon on the assumption that it is natural cooling of transformer cooling system. Through this study, by examining the temperature distribution and hot-spot of the structure field of the mold transformer, cooling design and temperature distribution information, which are demanded for designing are estimated.

여러가지 자기장 배치 기법에 따른 자성유체 속도 및 압력 분포에 관한 수치해석적 연구 (Numerical analysis of the magnetic fluid velocity and pressure distribution according to the various magnetic field)

  • 송준호;이육형;배형섭
    • 한국기계가공학회지
    • /
    • 제7권2호
    • /
    • pp.31-37
    • /
    • 2008
  • In this paper, we analyzed the dynamic behavior of magnetic fluid in a circular pipe with multiple permanent magnets. Magnetic fluid react on magnetic field against the normal fluid. In other words, magnetic fluid flow has the electromagnetism and fluid mechanics. So magnetic fluids has studied about the fluids properties and experiment. In this paper we studied the magnetic fluids velocity and pressure distribution for the novel type actuator. Because the velocity and pressure distribution is the important element of the magnetic fluids flow. First, we analyzed the Maxwell equation for the multiple permanent magnet and then concluded the governing equations for the magnetic fluid flow using the equation of Navier-Stokes. And, we simulated the dynamic behavior of magnetic fluid flow using the FEM(Finite Element Method). And we illustrated the relation between magnetic field and dynamic behavior of magnetic fluid flow.

  • PDF

연소로의 화염분포가 보일러 관로에 미치는 영향에 관한 연구 (A Study on the Imfluence of the Pipe Line of Boiler for Flame Distribution of Combustion Furnace)

  • 조동현
    • 수산해양교육연구
    • /
    • 제26권6호
    • /
    • pp.1435-1441
    • /
    • 2014
  • The fire took place in the synthetic heat transfer fluid boiler used in production process of medium density fiberboard. This study investigated pressure distribution of the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner. Pressure distribution at steady state in combustion furnace is 2~5mAq and pressure distribution at inverter under fault condition in combustion furnace is 10~-53mAq. The decrement of coil thickness measurement for synthetic heat transfer fluid boiler is 0~5mm.

The effect of nanoparticle in reduction of critical fluid velocity in pipes conveying fluid

  • Ghaitani, M.M.;Majidian, A.;Shokri, V.
    • Advances in concrete construction
    • /
    • 제9권1호
    • /
    • pp.103-113
    • /
    • 2020
  • This paper deal with the critical fluid velocity response of nanocomposite pipe conveying fluid based on numerical method. The pressure of fluid is obtained based on perturbation method. The motion equations are derived based on classical shell theory, energy method and Hamilton's principle. The shell is reinforced by nanoparticles and the distribution of them are functionally graded (FG). The mixture rule is applied for obtaining the equivalent material properties of the structure. Differential quadrature method (DQM) is utilized for solution of the motion equations in order to obtain the critical fluid velocity. The effects of different parameters such asCNT nanoparticles volume percent, boundary conditions, thickness to radius ratios, length to radius ratios and internal fluid are presented on the critical fluid velocity response structure. The results show that with increasing the CNT nanoparticles, the critical fluid velocity is increased. In addition, FGX distribution of nanoparticles is the best choice for reinforcement.

Numerical study of fluid behavior on protruding shapes within the inlet part of pressurized membrane module using computational fluid dynamics

  • Choi, Changkyoo;Lee, Chulmin;Park, No-Suk;Kim, In S.
    • Environmental Engineering Research
    • /
    • 제25권4호
    • /
    • pp.498-505
    • /
    • 2020
  • This study analyzes the velocity and pressure incurred by protruding shapes installed within the inlet part of a pressurized membrane module during operation to determine the fluid flow distribution. In this paper, to find the flow distribution within a module, it investigates the velocity and pressure values at cross-sectional and outlet planes, and 9 sections classified on outlet plane using computational fluid dynamics. From the Reynolds number (Re), the fluid flow was estimated to be turbulent when the Re exceeded 4,000. In the vertical cross-sectional plane, shape 4 and 6 (round-type protrusion) showed the relatively high velocity of 0.535 m/s and 0.558 m/s, respectively, indicating a uniform flow distribution. From the velocity and pressure at the outlet, shape 4 also displayed a relatively uniform fluid velocity and pressure, indicating that fluid from the inlet rapidly and uniformly reached the outlet, however, from detailed data of velocity, pressure and flowrate obtained from 9 sections at the outlet, shape 6 revealed the low standard deviations for each section. Therefore, shape 6 was deemed to induce the ideal flow, since it maintained a uniform pressure, velocity and flowrate distribution.

초임계유체의 작동변수가 지방산 에스터의 분배계수에 미치는 영향 (The Effects of Operation Variables of Supercritical Fluid on the Distribution Coefficients of Fatty Acid Esters)

  • 허병기;노덕우;우동진
    • KSBB Journal
    • /
    • 제14권5호
    • /
    • pp.633-637
    • /
    • 1999
  • 초임계 유체 이산화탄소를 이용하여 그 온도와 밀도가 물고기 기름의 구성성분인 각종 지방산 에스터의 분배계수에 미치는 영향을 규명하였다. 각 지방산 에스터의 분배계수는 초임계 유체의 온도와 밀도에 따라서 상당한 차이를 나타내어 이산화탄소유체에 의한 지방산의 초임계 유체 추출분리 가능성을 확인할 수 있었다. 각 지방산의 분배계수 차이가 크게 나타나는 초임계 유체의 밀도는 0.3 g/mL 내지 0.4 /mL사이의 범위에 분포되어 있었다. 또한 각 지방산은 모두 초임계 유체의 밀도가 낮은 쪽보다 높은 쪽에서 온도에 따른 역행응축현상을 나타내었다.

  • PDF

하이브리드법을 이용한 열전냉각의 수치해석 연구 (Computer Simulation Study of the Thermoelectric Cooling by Hybrid Method)

  • 김남진;이재용;김종보
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.97-108
    • /
    • 2000
  • The purpose of this study is to minimize the heat transfer surface area and cold fluid exit temperature of heat exchanger which applied to the refrigeration and air-conditioning system by utilizing the thermoelectric principle. Both uniform and non-uniform current distribution methods which applied to the analysis of the TE elements that incorporates heat exchanger were investigated. The non-uniform current distribution method had the better coefficient of performance and had the lower cold fluid exit temperature of the TE cooling system than the uniform current distribution method. It was found that if a TE cooling system incorporates a heat exchanger, a non-uniform current distribution should guarantee to the lowest cold fluid exit temperature. Also, the hybrid method (combination of the uniform and non-uniform current distribution method) is investigated to achieve the best results by combining the uniform and non-uniform current distributions. The results show that it can lower the cold fluid exit temperature and reduce the heat transfer surface area for the parallel flow arrangement if we apply the constant current in some entry region and the non-uniform increasing current in the direction of the cold fluid flow afterwards.

  • PDF

Estimation of Suitable Methodology for Determining Weibull Parameters for the Vortex Shedding Analysis of Synovial Fluid

  • Singh, Nishant Kumar;Sarkar, A.;Deo, Anandita;Gautam, Kirti;Rai, S.K.
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권1호
    • /
    • pp.21-30
    • /
    • 2016
  • Weibull distribution with two parameters, shape (k) and scale (s) parameters are used to model the fatigue failure analysis due to periodic vortex shedding of the synovial fluid in knee joints. In order to determine the later parameter, a suitable statistical model is required for velocity distribution of synovial fluid flow. Hence, wide applicability of Weibull distribution in life testing and reliability analysis can be applied to describe the probability distribution of synovial fluid flow velocity. In this work, comparisons of three most widely used methods for estimating Weibull parameters are carried out; i.e. the least square estimation method (LSEM), maximum likelihood estimator (MLE) and the method of moment (MOM), to study fatigue failure of bone joint due to periodic vortex shedding of synovial fluid. The performances of these methods are compared through the analysis of computer generated synovial fluidflow velocity distribution in the physiological range. Significant values for the (k) and (s) parameters are obtained by comparing these methods. The criterions such as root mean square error (RMSE), coefficient of determination ($R^2$), maximum error between the cumulative distribution functions (CDFs) or Kolmogorov-Smirnov (K-S) and the chi square tests are used for the comparison of the suitability of these methods. The results show that maximum likelihood method performs well for most of the cases studied and hence recommended.

Fluid Queueing Model with Fractional Brownian Input

  • Lee, Jiyeon
    • Communications for Statistical Applications and Methods
    • /
    • 제9권3호
    • /
    • pp.649-663
    • /
    • 2002
  • We consider an unlimited fluid queueing model which has Fractional Brownian motion(FBM) as an input and a single server of constant service rate. By using the result of Duffield and O'Connell(6), we investigate the asymptotic tail-distribution of the stationary work-load. When there are multiple homogeneous FBM inputs, the workload distribution is similar to that of the queue with one FBM input; whereas for the heterogeneous sources the asymptotic work-load distributions is dominated by the source with the largest Hurst parameter.