• Title/Summary/Keyword: Fluid Added Mass

Search Result 169, Processing Time 0.03 seconds

A Study on the Vibration Characteristics of 3-Dimension Submerged Vehicle in Consideration of Fluid-Structure Interaction (유체력을 고려한 3차원 수중압력선체의 진동특성에 관한 연구)

  • 손충렬;김경수;변효인
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • Unlike structures in the air, the vibration analysis of a submerged or floating structure such as offshore structures or ships is possible only when the fluid-structure interaction is understood, as the whole or part of the structure is in contact with water. This paper introduces two methods to find natural frequency in consideration of fluid-structure interaction, direct coupled vibration analysis and fluid-structure modal coupled vibration analysis. The purpose of this study is to analyze the vibration characteristic of a submerged vehicle to obtain the anti-vibration design data, which could be used in the preliminary design stage. The underwater pressure hull of submerged vehicle is used as the model of this study. The F.E.M. model is meshed by shell and beam elements. Also, considering the inner hull weight, the mass element is distributed in the direction of hull length. Numerical calculations are accomplished by using the commercial B.E.M. code. The characteristics of natural frequency, mode shape and frequency-displacement response are analyzed.

  • PDF

A Study on Behavior of Rectangular Liquid Storage Structures (직사각형 단면을 갖는 유체 저장 구조물의 거동에 관한 연구)

  • 박장호
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.101-107
    • /
    • 2003
  • Dynamic behavior of flexible rectangular liquid storage structures is analysed by the developed method. The rectangular liquid storage structures are assumed to be fixed to the ground and a moving coordinate system is used. The irrotational motion of invicid and incompressible ideal fluid is represented by two analytic solutions. One is the solution of the fluid motion in the rigid rectangular liquid storage structure due to ground motions and the other is the solution of the fluid motion by the motion of the wall in the flexible rectangular liquid storage structure. The motion of structure is modeled by finite elements. The fluid-structure interaction effect is reflected into the coupled equation of motion as added fluid mass matrix. The free surface sloshing motion and hydrodynamic pressure acting on the wall in the flexible rectangular liquid storage structure due to the horizontal ground motion are obtained by the developed method and verified.

Damping Effects of a Flexible Structure Interacting with Surrounding Acoustic Fluid (주변 음장과 연동하는 탄성 구조체의 감쇠 효과)

  • Lee, Moon-Seok;Park, Youn-Sik;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.101-105
    • /
    • 2008
  • A flexible structure submerged in acoustic fluid is affected by its surrounding fluid. In transient response of a submerged structure, the coupled effect between structures and surrounding fluid emerges as damping and added mass at early and late time, respectively. Therefore, the characteristics of submerged structure such as natural frequencies and damping coefficients are changed by its surrounding fluid. In this paper, the analytic modal equation of a spherical shell surrounded by water and air is dealt with. Through the example, the damping coefficients and natural frequencies of flexible structures are studied for various external acoustic fluid and structures.

  • PDF

Experimental Modal Analysis of Perforated Rectangular Plates Coupled with Fluid (유체로 연성된 다공 직사각평판의 실험적 모드 해석)

  • 유계형;이명규;정경훈;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.900-903
    • /
    • 2002
  • This study dealt with the experimental modal analysis of the perforated rectangular plate coupled with fluid. The natural frequencies of the perforated plate and solid plate in air were obtained by the analytical method based on the relation between the reference kinetic and maximum potential energy and compared with the experimental results. Good agreement between the results was found for the natural frequencies of the perforated plate in air. It was empirically found the natural frequencies of the perforated plate coupled with fluid. The transverse vibration modes, in-phase and out-of-phase, were observed alternately in the fluid-coupled system. Additionally, the effect of distance between perforated plate and solid plate on the fluid-coupled natural frequency was investigated.

  • PDF

Numerical simulation of 2-D fluid-structure interaction with a tightly coupled solver and establishment of the mooring model

  • Tsai, I-Chen;Li, Sing-Ya;Hsiao, Shih-Chun;Hsiao, Yu
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.433-449
    • /
    • 2021
  • In this study, a newly enhanced Fluid-Structure Interaction (FSI) model which incorporates mooring lines was used to simulate a floating structure. The model has two parts: a Computational Fluid Dynamics (CFD) model and a mooring model. The open-source CFD OpenFOAM® v1712 toolbox was used in the present study, and the convergence criteria and relaxation method were added to the computational procedure used for the OpenFOAM multiphase flow solver, interDyMFoam. A newly enhanced, tightly coupled solver, CoupledinterDyMFoam, was used to decrease the artificial added mass effect, and the results were validated through a series of benchmark cases. The mooring model, based on the finite element method, was established in MATLAB® and was validated against a benchmark analytical elastic catenary solution and numerical results. Finally, a model which simulates a floating structure with mooring lines was successfully constructed by connecting the mooring model to CoupledinterDyMFoam.

Vibration Analysis of Rotary Specimen Rack (RSR) in a Still Fluid and Stress Analysis of Clamp Part of RSR (정지 유체 내에 있는 회전시료조사대의 진동해석 및 지지부의 응력해석)

  • 김성균;이동규;이근우;정운수;박진호
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.23-28
    • /
    • 2003
  • In this paper, in-air and in-water vibration characteristics of Rotary Specimen Rack (RSR) are estimated through 3D finite element modeling by using ANSYS software. Added mass is calculated by using Blevins' equation. To confirm the reasonability of the results presented in this study, obtained results are compared to those of using a theoretical equation. It is confirmed that in-water natural frequencies of the RSR are lower than in-air ones due to the added mass effect of the fluid. Also, to design clamp which needs to fix RSR, Von-Mises stress and displacement of RSR to clamp pressure are calculated.

Hydroelastic vibration analysis of wetted thin-walled structures by coupled FE-BE-Procedure

  • Rohr, Udo;Moller, Peter
    • Structural Engineering and Mechanics
    • /
    • v.12 no.1
    • /
    • pp.101-118
    • /
    • 2001
  • The reliable prediction of elastic vibrations of wetted complex structures, as ships, tanks, offshore structures, propulsion components etc. represent a theoretical and numerical demanding task due to fluid-structure interaction. The paper presented is addressed to the vibration analysis by a combined FE-BE-procedure based on the added mass concept utilizing a direct boundary integral formulation of the potential fluid problem in interior and exterior domains. The discretization is realized by boundary element collocation method using conventional as well as infinite boundary element formulation with analytical integration scheme. Particular attention is devoted to modelling of interior problems with both several separate or communicating fluid domains as well as thin-walled structures wetted on both sides. To deal with this specific kind of interaction problems so-called "virtual" boundary elements in areas of cut outs are placed to satisfy the kinematical conditions in partial connected fluid domains existing in realistic tank systems. Numerical results of various theoretical and practical examples demonstrate the performance of the BE-methodology presented.

Vibration Measurements of an Intelligent Cantilever Beam in Contact with Fluid

  • Kwon, Tae-Kyu;Park, Seong-Hwa;Yu, Gye-Hyoung;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.97.3-97
    • /
    • 2002
  • This paper presents the vibration characteristics of an intelligent cantilever beam in contact with a fluid using a PZT actuator and PVDF film. The dynamic behaviors of a flexible beam-water interaction system are examined. The effect of the liquid level on free vibration of the composite beam in a partially liquid-filled circular cylinder is investigated. The coupled system is subject to an undisturbed boundary condition in the fluid domain. It was found that the coupled natural frequencies decreased with the fluid level for the identical composite beam due to added mass effect. In case of the free-free boundary condition, the natural frequency gently decreased at fluid water level betw...

  • PDF

Dynamic Analysis of Rectangular Liquid Storage Structures Excited by Horizontal and Vertical Ground Motions (수평 및 수직 지반운동을 받는 직사각형 유체 저장 구조물의 동적 해석)

  • Park, Jang-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.108-117
    • /
    • 2004
  • Dynamic analysis method is Presented for analyzing rectangular liquid storage structures excited by horizontal and vertical ground motions. The irrotational motion of invicid and incompressible ideal fluid in rigid rectangular liquid storage structures subjected to horizontal and vertical ground motions and the motion of fluid induced by structural deformation are expressed by analytic solutions. Analysis methods are obtained by applying analytic solutions of the fluid motion to finite element equation of the structural motion. The fluid-structure interaction effect is reflected into the coupled equation as added fluid mass matrix. The free surface sloshing motion, hydrodynamic pressure acting on the wall and structural behavior due to horizontal and vertical ground motions are obtained by the presented method.