• Title/Summary/Keyword: Flue gas desulfurization (FGD)-gypsum

Search Result 18, Processing Time 0.023 seconds

The Comparison of Analytical Methods for Gypsum and Gypsum Slurry (석고 및 석고 슬러리에 대한 분석방법의 비교)

  • Kim, Kyeongsook;Yang, Seugran;Park, Hyunjoo;Lim, Chunsik
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.158-165
    • /
    • 2000
  • The purity of gypsum and quantitation of impurities of flue gas gypsum will not only play an important role in deciding of the optimal condition during a trial run of FGD (flue gas desulfurization), but also can be utilized in quality control of gypsum. The purity of gypsum can be determined from combined water, sulfur trioxide and calcium concentration. We found that the thermal analysis by TGA (thermogravimetric analysis) was the most accurate and convenient method to determine the purity of gypsum. This method will be done in a hour and the results were reproducible. On the other hand, the best way of the analysis of impurities in gypsum was fusion method using $LiBO_2$ as a fusion agent. We also determined the amount of $CO_2$ gas to analyze magnesium carbonate and calcium carbonate contents. The analyses of combined water by TGA, fusion method followed by ICP-AES (inductively coupled plasmaatomic emission spectroscopy) and determination of $CO_2$ amount can lead to more accurate and convenient method for gypsum analysis.

  • PDF

Improving Quality of Eco-Friendly Mortar using Blast Furnace Slag and Recycled Aggregate Depending on Replacement Ratio of Desulfurized Gypsum (고로슬래그 미분말과 순환잔골재를 사용하는 친환경 모르타르에 탈황석고에 의한 품질향상)

  • Lu, Liang Liang;Baek, Byung Hoon;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.148-149
    • /
    • 2014
  • The aim of this research is to contribute on investment of less cement mortar or concrete in normal strength range using additional hydration of BS with stimulating effect of FGD and OPC based on the previous research result of the BS and RFA using cement mortar. As a test, the composition for normal strength range of mortar was evaluated with 0, 10, and 20 % of FDA and 0, 20 % of OPC replacement.

  • PDF

Quality Increase of Mortar that Uses Cyclic Aggregate and Blast Furnace Slag Due To Changes in Desulfurized Plaster Processing Method (탈황석고의 처리방법 변화에 따른 순환골재와 고로슬래그를 사용한 모르타르의 품질향상)

  • Song, Yuan-Lou;Park, Yong-Jun;Lee, Myung-Ho;Lee, Dong-Yun;Jo, Man-Ki;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.57-58
    • /
    • 2015
  • In this research the processing method of Desulfurized Plaster is changed to cyclotomy, 0.3mm sieve analysis and 500℃ heat exposure, and by changing the mix rate of the binding agent to 0~20%, it was applied to mortar that used cyclic aggregate and blast furnace slag for testing. The test results showed that the flow decreased in the order of cyclotomy, high heat exposure, and sieve analysis according to the mix rate of FGD, and while the air volume decreased for cyclotomy, it was shown to have almost no effect on sieve analysis and high heat exposure. The setting time accelerated as the mixing rate of FGD increased, and the compression strength increased as the mixing rate of FGD increased and especially showed a high trend with cyclotomy and sieve analysis.

  • PDF

Blast Furnace Slag Powder High Volume Substitution Mortar Quality Increase Due To Changes in Desulfurized Plaster Processing Method (탈황석고의 처리방법 변화에 의한 고로슬래그 미분말 다량 치환 모르타르의 품질향상)

  • Song, Yuan-Lou;Park, Yong-Jun;Kim, Sang-sup;Lee, Dong-Yun;Jang, Duk-Bae;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.55-56
    • /
    • 2015
  • In this research the processing method of Desulfurized Plaster is changed to cyclotomy, 0.3mm sieve analysis and 500℃ heat exposure, and by changing the mix rate of the binding agent to 0~20%, it was applied to mortar that used natural aggregate and blast furnace slag for testing. The test results showed that the sieve analysis and high heat exposure of the flow and air volume increased according to the increase of mixing rate of FGD while the cyclotomy decreased. The setting time accelerated as the mixing rate of FGD increased, and the compression strength increased to its maximum when the mixing rate of FGD was right around 10%, and especially showed a high trend with cyclotomy and sieve analysis.

  • PDF

Improving Quality of Eco-Mortar Incorporating Blast Furnace Slag and Recycled Aggregate Depending on Replacement Gypsum and Cement (고로슬래그 미분말과 순환잔골재를 사용하는 친환경 모르타르에 탈황석고 및 시멘트에 의한 품질향상)

  • Baek, Byung Hoon;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.193-199
    • /
    • 2015
  • As a solution of both environmental issue of reducing carbon dioxide emission and sustainable issue of exhausting natural resources, in concrete industry, many research on recycling various by-products or industrial wastes as the concrete materials has been conducted. The aim of this research is feasibility analysis of additional reaction with ordinary Portland cement and flue gas desulfurization gypsum based on the blast furnace slag and recycled fine aggregate based mortar to achieve the normal strength range. Consequently, in the case of mortar replaced 10% FGD and 30% OPC for BS, 80% of plain OPC mortar's compressive strength was achieved. Furthermore, when the water-to-binder ratio is decreased to keep the practically similar level of flow, it is expected to be achieve the equivalent compressive strength to plain OPC mortar.

Estimation of Washing Duration of Desulfurized Absorber in a Heavy Oil Power Plant (중유화력발전소 탈황 흡수탑 세정시기예측)

  • Jang, Yeong Gi;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.24-28
    • /
    • 2016
  • In desulfurization facilities of oil-fired power plant, gypsum scale is attached in the absorber inner surface as the operating time increases. For this reason, the maximum possible load of the power generation is set down, resulting in further generation stop. Cleaning of absorber for scale removal can be determined at the time of setting down of the maximum possible load. In this study, 6 weeks before the maximum possible load of the power generation was down set, at the same time and desulfurization facilities outlet $SO_2$ concentration value was more than 130ppm, absorber differential pressure exceeded $380mmH_2O$, it was confirmed to be the time that has elapsed 44 weeks after the previous absorber cleaning. Cleaning time of the absorber was predicted to be a time which has elapsed 50 weeks from the previous cleaning time.

  • PDF

Evaluation of SO2 Absorption Efficiency for Calcined Oyster Shell Slurry Using a Simulated Spray Type-flue Gas Desulfurization (FGD) System: A Comparative Study with Limestone Slurry (모사 Spray Type 배연탈황설비를 이용한 소성패각 슬러리의 SO2 흡수능 평가: 석회석과의 비교연구)

  • Kim, Seok-Hwi;Hong, Bum-Uh;Lee, Jin-Won;Cha, Wang-Seok;Kim, Kangjoo;Moon, Bo-Kyung
    • Economic and Environmental Geology
    • /
    • v.52 no.2
    • /
    • pp.119-128
    • /
    • 2019
  • About 300,000 tones of oyster shell are annually produced in Korea and, thus, a massive recycling plan is required. Many desulfurizing studies using oyster shells with chemical composition of $CaCO_3$ have been performed so far; however, most of them have focused on dry desulfurization. This study investigates the possibility of using oyster shells for wet desulfurization after calcination. For this, a simulated wet desulfurization facility of spray type was devised and compared the SOx-stripping characteristics of calcined oyster shell with those of limestone. The calcined oyster shell slurry indicate a better desulfurizability than the slurries of raw shell or limestone because the oyster shell transformed to a more reactive phase ($Ca(OH)_2$) by the calcination and hydration. Because of this reason, when the calcined oyster shell slurries were used, the reaction residue showed the higher gypsum ($CaSO_4{\cdot}2H_2O$) contents than any other cases. In the continuous desulfurization experiments, calcined oyster shell slurry showed a wider pH variation than limestone or raw oyster shell slurries, another clear indication of high reactivity of calcined oyster shells for $SO_2$ absorption. Our study also shows that the efficiency of wet desulfurization can be improved by the use of calcined oyster shells.

Analysis of Radioactivity Concentration in Naturally Occurring Radioactive Materials Used in Coal-Fired Plants in Korea (국내 석탄연소 발전소에서 취급하는 천연방사성물질의 방사능 농도 분석)

  • Kim, Yong Geon;Kim, Si Young;Ji, Seung Woo;Park, Il;Kim, Min Jun;Kim, Kwang Pyo
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.173-179
    • /
    • 2016
  • Coals and coal ashes, raw materials and by-products, in coal-fired power plants contain naturally occurring radioactive materials (NORM). They may give rise to internal exposure to workers due to inhalation of airborne particulates containing radioactive materials. It is necessary to characterize radioactivity concentrations of the materials for assessment of radiation dose to the workers. The objective of the present study was to analyze radioactivity concentrations of coals and by-products at four coal-fired plants in Korea. High purity germanium detector was employed for analysis of uranium series, thorium series, and potassium 40 in the materials. Radioactivity concentrations of $^{226}Ra$, $^{228}Ra$, and $^{40}K$ were $2{\sim}53Bq\;kg^{-1}$, $3{\sim}64Bq\;kg^{-1}$, and $14{\sim}431Bq\;kg^{-1}$ respectively in coal samples. For coal ashes, the radioactivity concentrations were $77{\sim}133Bq\;kg^{-1}$, $77{\sim}105Bq\;kg^{-1}$, and $252{\sim}372Bq\;kg^{-1}$ in fly ash samples and $54{\sim}91Bq\;kg^{-1}$, $46{\sim}83Bq\;kg^{-1}$, and $205{\sim}462Bq\;kg^{-1}$ in bottom ash samples. For flue gas desulfurization (FGD) gypsum, the radioactivity concentrations were $3{\sim}5Bq\;kg^{-1}$, $2{\sim}3Bq\;kg^{-1}$, and $22{\sim}47Bq\;kg^{-1}$. Radioactivity was enhanced in coal ash compared with coal due to combustion of organic matters in the coal. Radioactivity enhancement factors for $^{226}Ra$, $^{228}Ra$, and $^{40}K$ were 2.1~11.3, 2.0~13.1, and 1.4~7.4 for fly ash and 2.0~9.2, 2.0~10.0, 1.9~7.7 for bottom ash. The database established in this study can be used as basic data for internal dose assessment of workers at coal-fired power plants. In addition, the findings can be used as a basic data for development of safety standard and guide of Natural Radiation Safety Management Act.