• 제목/요약/키워드: Flue Tube

검색결과 44건 처리시간 0.021초

석탄화력 탈황설비 Non-leakage Type Gas-Gas Heater(GGH) 운영 및 개선사례 (Operation and Improvement Cases of FGD Non-leakage Type Gas-Gas Heater(GGH) for Coal Fired Power Plants)

  • 성기종;이창식
    • 한국연소학회지
    • /
    • 제22권4호
    • /
    • pp.35-42
    • /
    • 2017
  • This case covers the issues related to the operation problem, cause analysis and improvement cases of the FGD that employed the non-leakage type GGH in coal-fired power plant for the first time in Korea. In the Cooler, there was a main problem that the tube is damaged by the ash cutting due to the high velocity of flue gas in the duct and by the weak wear resistance of material. In the Reheater, there was a main problem that the tube was corroded due to chlorine and sulfur in the circumstance of the low temperature. In order to solve those problems, we have improved the Reheater tube and tube fins by coating enamel to reduce corrosion rate.

테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes)

  • 이장호;김형대;김정배;김무환
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

석회석 분말을 이용한 노내 고온 건식 탈황 특성 연구 (Effect of Limestone Characteristics on In-Furnace Desulfurization under Hot Gas Combustion)

  • 김상인;이병화;안기주;황민영;김승모;전충환
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.43-45
    • /
    • 2012
  • The effect of limestone characteristics on in-furnace desulfurization was experimentally investigated at hot gas combustion condition in a drop tube furnace (DTF). Flue gas was measured by Gas analyzer in order to figure out $SO_2$ content. The experiments were performed under excess sulfur 3000ppm condition to examine the effect of operating variables such as reaction temperatures, Ca/S ratios on the $SO_2$ removal efficiencies. The results show that the $SO_2$ removal efficiency increased with reaction temperature and Ca/S ratio increase. When considering the economics, $1200^{\circ}C$ and Ca/S ratio 2 condition is optimized to reduce $SO_2$ emission.

  • PDF

입자 순환식 열교환기의 상승관 설계방법 (Riser Design Approach for Particle-Circulation-Type Heat Exchangers)

  • 전용두
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.311-312
    • /
    • 2002
  • In this paper a systematic design approach to determine the optimum size (height) of circulating fluidized bed heat exchanger for exhaust gas heat recovery is prososed. Unlike the convensional heat exchangers where the length of the heat exchanger section is not very much emphasized, the vertical length of heat exchanger tube in the case of fluidized bed heat exchangers is important because this length determines the time interval during which particles reside and transfer heat in the heat exchanger section. For particles initial conditions are nearly stationary, accelerating particles motion should be considered rather than simply assuming fully developed condition. A way to estimate optimum tube length at different fluid velocity and particle sizes is suggested based on the required conditioning time for heat transfer from the flue gas to solid particles.

  • PDF

미연분 및 NOx배출 특성에 대한 고회분탄의 영향 연구 (Effect of High Ash Coal on Unburned Carbon and NOx Emission)

  • 김상인;이병화;임호;안기주;김만철;송주헌;전충환
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.341-342
    • /
    • 2012
  • The effect of high ash coal which has relatively high ash content and low combustibility on unburned carbon and NOx emission was experimentally investigated at several excess air ratio and particle size conditions of four coals containing different ash content in a drop tube furnace. Flue gas was measured by Gas analyzer in order to figure out unburned carbon characteristics. The results show that the higher content of ash makes the higher unburned carbon rate, subsequent changes in NOx emission characteristics was investigated.

  • PDF

중유 싱글 버너 수관식 보일러에서의 합성가스 혼합연소 특성 연구 (A Study on Syngas Co-Combustion Characteristics in a 0.7 MWth Water-Tube Boiler with Single Heavy Oil Burner)

  • 최신영;양동진;방병열;양원
    • 한국수소및신에너지학회논문집
    • /
    • 제21권5호
    • /
    • pp.452-459
    • /
    • 2010
  • This study is aimed to investigate changes of combustion characteristics and heat efficiency when syngas from gasification process using low-rank fuel such as waste and/or biomass is applied partially to an industrial boiler. An experimental study on syngas co-combustion was performed in a 0.7 MW (1 ton steam/hr) water tube boiler using heavy oil as a main fuel. Three kinds of syngas were used as an alternative fuel: mixture gas of pure carbon monoxide and hydrogen, syngas of low calorific value generated from an air-blown gasification process, and syngas of high calorific value produced from an oxygen-blown gasification process. Effects of co-combustion ratio (0~20%) for each syngas on flue gas composition were investigated through syngas injection through the nozzles installed in the side wall of the boiler and measuring $O_2$, $CO_2$, CO and NOx concentrations in the flue gas. When syngas co-combustion was applied, injected syngas was observed to be burned completely and NOx concentration was decreased because nitrogen-containing-heavy oil was partially replaced by the syngas. However, heat efficiency of the boiler was observed to be decreased due to inert compounds in the syngas and the more significant decrease was found when syngas of lower calorific value was used. However, the decrease of the efficiency was under 10% of the heat replacement by syngas.

멀티버너 보일러용 열교환기 모듈 특성 시험 - 모듈 순서에 따른 특성결과 - (Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler)

  • 강새별;김종진;안준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3053-3058
    • /
    • 2008
  • We develop a heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 1 MPa and tested steam pressure is 0.7 MPa. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). We tested the heat exchanger module with changing the position of each heat exchanger module. We measured the inlet and outlet temperature of each heat exchanger module and calculated the heat exchange rate. The results show that if module C is placed at second stage (the 1st stage is always module O, bare tube module), there is no need to attach an additional heat exchanger module. In this case the exit temperature of module C is low enough to enter an economizer which is more effective in heat recovery than a heat exchanger module.

  • PDF

국내 수입탄 촤의 산화반응률 측정을 위한 해석기법 비교 (Determination of Char Oxidation Rates with Different Analytical Methods)

  • 이병화;송주헌;강기태;장영준;전충환
    • 대한기계학회논문집B
    • /
    • 제33권11호
    • /
    • pp.876-885
    • /
    • 2009
  • Char oxidation experiments were performed with a sub-bituminous roto-middle coal in the Drop Tube Furnace (DTF) at atmospheric pressure condition. While temperatures varied between 900, 1100, 1400 $^{\circ}C$, particle size, mass, particle temperature, and CO/$CO_2$ concentration were obtained to be used for kinetic analysis of the char oxidation. This study addresses several different methods to analyze the char consumption rate, which are classified as energy balance method, ash-traced mass method, flue-gas based method, and particle size based method. The char consumption rate obtained with such methods was compared with the results of Monson et al.$^{(24)}$ While there are some differences between them because of differences in experimental apparatus and parameters to be measured, the kinetic results seems to be reasonable enough to be incorporated in a numerical modeling of coal combustion.

Drop Tube Furnace에서 석탄의 순산소 연소 특성 (A Study on the Oxy-Combustion of the Coal in Drop Tube Furnace)

  • 노선아;윤진한;이정규;길상인;민태진;김상복;박인용;한방우;김진태
    • 청정기술
    • /
    • 제27권4호
    • /
    • pp.367-371
    • /
    • 2021
  • 순산소 석탄 화력 발전 시스템은 CO2 가스 회수 및 저장 기술(CCS: carbon capture & storage)의 하나로 순산소와 재순환된 연소가스를 이용하여 석탄 연소를 수행하는 기술이다. 이는 이산화탄소와 질소가 혼합된 배출 가스를 생산하는 기존의 공기 연소 시스템과 달리 공기 중의 산소를 먼저 분리하여 생산된 순산소와 재순환된 연소 가스를 이용하여 석탄을 연소하면 이산화탄소와 질소를 분리하는 후처리 공정 없이 이산화탄소만으로 이루어진 배출 가스를 생성하여 이의 저장을 용이하게 하는 기술이다. 본 연구에서는 O2/CO2 혼합 모의 가스를 이용하여 순산소 연소 시 발생되는 대기오염물질인 NO, SO2의 생성 특성을 살펴보았다. 반응 온도를 900 ℃ ~ 1200 ℃, 산소 분율을 30% ~ 50%로 변화시키면서 실험한 결과 생성 가스 내 NO 및 SO2의 농도는 반응 온도와 산소 분율이 증가할수록 증가하는 현상을 나타내었으며 CO2의 분율도 증가하는 현상을 나타내었다. 순산소 연소에서 30% O2/CO2를 이용한 연소와 air 조건인 21% O2/N2 연소에서 NO 발생을 비교한 결과 양쪽 모두 반응 온도에 따라서 NO 발생이 증가하게 되며 순산소 연소 조건에서 air 연소에 비하여 약 40 ~ 80 ppm까지 NO 발생이 낮아지는 현상을 나타내었다.

양방향 펄스전원을 이용한 NO 가스의 방전처리 (Discharge Processes of NO Gas Using Bidirectional Pulsed Voltage)

  • 주홍진;박정호;심재학;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1682-1684
    • /
    • 2001
  • In removing the flue-gas using electrical discharge method, it is important to dissociate or ionize the atoms and molecules by the collisions with energetic electrons and it produces the radicals that are used to decompose the pollutants. For that purpose, a bidirectional pulsed voltage is used to produce lots of energetic electrons efficiently and increase the power efficiency. The simulation is performed with changing the pulsewidth under the fixed applied voltage. The particle-mesh model coupling the NGP(nearest-grid-point) to FEM(finite element method) is used to simulate the behavior of electrons and the spatio-temporal variation of the electric field for the streamer in discharge tube.

  • PDF