• Title/Summary/Keyword: Flue Gas Recirculation

Search Result 59, Processing Time 0.026 seconds

Conceptual Design of 100 MWe Oxy-coal Power Plant-Youngdong Project (100 MWe 순산소 석탄연소 발전시스템의 개념설계-영동 프로젝트)

  • Choi, Sangmin
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.3
    • /
    • pp.30-45
    • /
    • 2012
  • An existing unit of power plant is considered to refurbish it for possible application of carbon capture and storage(CCS). Conceptual design of the plant includes basic considerations on the national and international situation of energy use, environmental concerns, required budget, and time schedule as well as the engineering concept of the plant. While major equipment of the recently upgraded power plant is going to be reused, a new boiler for air-oxy fired dual mode operation is to be designed. Cryogenic air separation unit is considered for optimized capacity, and combustion system accommodates flue gas recirculation with multiple cleaning and humidity removal units. The flue gas is purified for carbon dioxide separation and treatment. This paper presents the background of the project, participants, and industrial background. Proposed concept of the plant operation is discussed for the possible considerations on the engineering designs.

$NO_x$ Control by Flue Gas Recirculation in Pulverized Coal Combustion (미분탄 연소에서 배기가스 재순환에 의한 질소산화물 제어)

  • 장길홍;장인갑;선칠영;천무환;양관모
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.473-474
    • /
    • 1999
  • 일반적으로 NOx배출은 연소과정에 의해 강력하게 지배되고 있으며, NOx 저감 기술은 1970년대 후반부터 많은 연구들이 수행되어, 그 이론들이 확립되고 있다. 석탄 연소시스템에서는 공기 다단(air staging, OFA), 연료다단(fuel staging, reburning) 및 배기가스 재순환(FGR) 등이 대표적인 NOx 저감 기술이며 [1∼4], 그 중 배기가스 재순환법은 저산소 배기가스를 연소용 공기에 재혼입시키므로써 NO의 생성속도를 저하시켜 NOx를 저감시키는 기법이다.(중략)

  • PDF

Effect of Recirculated Exhaust Gas on Exhaust Emissions of Boiler with FGR System (FGR 시스템 보일러의 배기 배출물에 미치는 재순환 배기의 영향)

  • Bae, Myung-Whan;Kim, Jung-Min;Kim, Yi-Suk;Cho, Yong-Soo;Choi, Seung-Chul
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.390-395
    • /
    • 2003
  • The effect of recirculated exhaust gas on exhaust emissions under four kinds of nozzle tip with the different fuel consumption rate are experimentally investigated by using an once-through boiler with FGR system. The purpose of this study is to develop the FGR control system for reducing NOx in a boiler. Intake and exhaust oxygen concentrations, and equivalence ratio are applied to discuss the effect of FGR rate on exhaust emissions at various fuel consumption rates. It is found that NOx emissions are decreased, while soot emissions are increased owing to the drop of intake and exhaust oxygen concentrations, and the rise of equivalence ratio as FGR rates are elevated.

  • PDF

An Experimental Study on Mode Switching from Air-firing to Oxy-firing in Pilot-scale Combustion Systems (미분탄 순산소 연소 운전 모드 전환 과정에 대한 Pilot 규모 설비에서의 실험적 연구)

  • Choi, Chong-Gun;Na, Ik-Hwan;Lee, Jae-Wook;Chae, Tae-Young;Yang, Won;Kim, Young-Ju;Kim, Jong-An;Seo, Sang-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.3
    • /
    • pp.12-20
    • /
    • 2011
  • Oxy-coal combustion for $CO_2$ capture in coal power plants entails a mode switching from air-firing to oxyfiring. In this study, procedure of the mode switching was investigated and discussed through experiments in pilot scale facilities: (1) a 0.3 $MW_{th}$ furnace with a vertical single burner and a FGR(Flue Gas Recirculation) system (2) a 1 $MW_{th}$ furnace with horizontal 4 burners and a FGR system. Principle of the mode switching was established and performed with control of FD fan, FGR fan, ID fan and oxygen flow rates. We have found that equivalence ratio in the oxy-firing mode should be increased more than that in the air-firing to achieve stable mode switching. Control of FD, ID and FGR fans should be performed carefully in the mode switching, in the sense of complete combustion and flame attachment. Moisture contents in the ash and the flue gas recycled to the primary oxidizer stream should be removed to prevent condensation, corrosion and duct clogging.

Reduction of NO Emission by Two-Stage Combustion (2단 연소에 의한 NO 배출 저감에 관한 연구)

  • 유현석;최정환;오신규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.591-596
    • /
    • 1995
  • In order to investigate the reduction of NO emissions, natural gas was fueled for two-stage combustion apparatus. NO and CO emissions were described by five variables: total air ratio, primary air ratio, secondary air injection position, secondary air injection velocity, and swirl ratio. It was mainly observed that, as the primary air ratios of 0 and 0.4 NO emission decreased with increasing the secondary air injection position and secondary air injection velocity. The effect of weak swirl on NO emission was found to be insignificant.

A Numerical Analysis of the Characteristics with High Temperature Air Combustion in Counterflow Diffusion Flame (대향류 확산화염의 고온공기 연소특성에 관한 수치해석)

  • Cho, Eun Seong;Kobayashi, Hideaki;Chung, Suk Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.4
    • /
    • pp.9-14
    • /
    • 2003
  • High temperature air combustion technology has been utilized by using preheated air over 1100 K and excessive exhaust gas recirculation. Numerical analysis was performed to investigate the combustion characteristics with high temperature deficient oxygen air combustion by adopting a counterflow as a model problem accounting for detailed chemical kinetics. Methane($CH_4$) was used as a test fuel and calculated oxidizer conditions were low temperature high oxygen (300K, $X_{O2}=0.21$) and high temperature low oxygen (1300K, $X_{O2}=0.04$) conditions. The latter case showed that the flame temperature is lower than the former case and its profile showed monotonic decrease from oxidizer to fuel side, without having local maximum flame temperature at high stretch rate. Also, heat release rate was one order lower and it has one peak profile because of low oxygen concentration and heat release rate integral is almost same for stretch rate. High temperature low oxygen air combustion shows low NO emission characteristics.

  • PDF

An Experimental Study of the Characteristics with High Temperature Air Combustion in Jet Diffusion Flames (제트확산염의 고온공기연소특성에 관한 실험적 연구)

  • Cho, Eun-Seong;Ohno, Ken;Kobayashi, Hideaki;Chung, Suk-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.89-94
    • /
    • 2003
  • For the development of high efficiency and low emission combustion systems, high temperature air combustion technology has been tested by utilizing preheated air over 1100 K and exhaust gas recirculation. In this system, combustion air is diluted with large amount of exhaust gases ($N_2$, $CO_2$), such that the oxygen concentration is relatively low in the reaction zone, leading to low flame temperature. Since, the temperature fluctuations and sound emissions form the flame are small and flame luminosity is low, the combustion mode is expected to be flameless or mild combustion. Experiment was performed to investigate the turbulent flame structure and $NO_X$ emission characteristics in the high temperature air combustion focused on coflowing jet diffusion flames which has a fundamental structure of many practical combustion systems. The effect of turbulence has also been evaluated by installing perforated plate in the oxidizer inlet nozzle. LPG was used as a fuel. Results showed that even though $NO_X$ emission is sensitive to the combustion air temperature, the present high temperature air combustion system produce low $NO_X$ emission because it is operated in low oxygen concentration condition in excess of dilution.

  • PDF

A study on a uniformity of flow field in a duct cooler of FGD system (배연탈황설비 덕트쿨러에서의 유동균일화에 관한 연구)

  • 배진효;김광추;박만흥;박경석;이종원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.120-130
    • /
    • 2000
  • A flow uniformity in a duct cooler of duct system of FGD(Flue Gas Desulfurization) linking a reheater and a absorber has been investigated in the present study. For this purpose, the flow characteristics according to the geometry of a vertical and horizontal vane in a curved duct of the duct system has been examined with the aid of a numerical simulation. The results indicate that the vertical vane with a little deflection toward a recirculation region makes the flow distribution in the duct cooler more uniform than that without deflection, and horizontal vane does not effect the change of the flow distribution for an angle of inclination. The mean flow uniform factor shows its maximum for duct system without the vane(case NP) and its minimum for the vertical vane with a little deflection(case P-0.8-0) .

  • PDF

Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in Power Plant Boilers with FGR System (FGR 시스템 공력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향)

  • Bae, Myung-Whan;Jung, Kwong-Ho;Choi, Seung-Chul;Cho, Yong-Soo;Kim, Yi-Suk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1686-1691
    • /
    • 2004
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air(OFA) damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_{x}$ emissions. To activate the combustion, the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$ , and the OFA with 0 to 20% into the flame is supplied, as the combustion air supplied to burner is reduced. It is found that the fuel consumption rate divided by evaporation rate does not show an obvious tendency to increase or decrease with rising the FOR rate, and $NO_{x}$ emissions are decreased, at the same OF A damper opening, as FOR rates are elevated and boiler loads are dropped.

  • PDF

A Study on the Effect of Recirculated Exhaust Gas upon Exhaust Emissions of Boiler with a FGR System (FGR 시스템 보일러의 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구)

  • Jung, Kwang-Ho;Cho, Yong-Soo;Bae, Myung-Whan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.405-415
    • /
    • 2007
  • The effects of recirculated exhaust gas on exhaust emissions under four kinds of nozzle tip with the different fuel consumption rates are experimentally investigated by using an once-through boiler with a FGR system. The purpose of this study is to develop the FGR control system for reducing $NO_x$ emissions in boilers. Intake and exhaust oxygen concentrations, and equivalence ratio are considered to figure out the effect of FGR rate on exhaust emissions at various fuel consumption rates. It is found that $NO_x$ emissions are markedly decreased, while soot emissions are increased owing to the drop of intake and exhaust oxygen concentrations, and the rise of equivalence ratio as FGR rates are elevated. One can also conclude that the reduction in $NO_x$ emissions is more considerably influenced by the variation of equivalence ratio due to the FGR rate than the fuel consumption rate.