• 제목/요약/키워드: Fluctuation characteristics

검색결과 886건 처리시간 0.025초

접지임피던스의 변동이 최소가 되는 동축형 탄소접지전극의 길이의 산정 (Determination of the Length of Coaxial Type Carbon Grounding Electrode to Minimize the Fluctuation of Grounding Impedance)

  • 이강수;김종호;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.164-170
    • /
    • 2010
  • For the surge currents like lightning or ground fault currents containing high frequency components which cause the electromagnetic interferences for the electronic devices and communication equipment, the grounding impedances give the significantly composite characteristics which are dependent on the frequency of surge currents. In this paper, the analytical model and method for determining the optimal length of the newly developed coaxial type carbon ground electrode which has a little fluctuation in grounding impedance with frequency. The length of minimizing the fluctuation of grounding impedance by changing frequency from 100[Hz] to 1[MHz] was determined, and the validity of this proposed method was confirmed by comparing with the simulated and measured data.

관내 희박 예혼합 프로판/공기와 메탄/공기 화염의 거동에 관한 실험적 연구 (Experimental Study on the Behaviors of Lean Premixed Flame of Propane/Air and Methane/Air in a Tube)

  • 곽영태;오광철;신현동
    • 한국연소학회지
    • /
    • 제10권2호
    • /
    • pp.35-41
    • /
    • 2005
  • Behaviors of lean premixed flame of propane/air and methane/air flame anchored by a pilot flame in a tube were investigated experimentally varying the mean velocity from 10 to 140 cm/s and the equivalence ratio from 0.45 to 0.8. Behaviors of both flames are divided into five regions of stable, flash-back, tail-out, flickering and vibrating. General characteristics of each region and Le number effect are investigated. Two main instabilities, flickering and vibration, are both unstable but the instability mechanism, the frequency and the amplitude of pressure fluctuation are different. In the edge of the vibrating region, pressure fluctuation repeats generation and extinction. Repeated growth and decrease of the amplitude of pressure fluctuation are explained by Rayleigh#s index.

  • PDF

통증 완화 치료기용 인체 부하 변동에 따른 피드백 제어가 가능한 고주파 회로 설계 (High Frequency Circuit Design using Feedback Control with Body Load Fluctuation for Pain Relief Therapy)

  • 박철원;원철희
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.45-49
    • /
    • 2013
  • High frequency system has been used for the purpose of skin care and obesity treatment, by high-frequency energy is applied to the human body generates deep heat. Conventional high frequency system could not selection control by depending on the body load fluctuations. Such as burns and side effects have been reported by system instability and then therapeutic effect is insufficient. During treatment, objective information about the status of the patient was no. Because of treatment methods are subjective, and so tailored treatments were impossible. In this paper, high frequency medical system with sinusoidal frequency characteristics without distortion of the Push pull switching scheme for pain relief therapy was designed. And control circuit that was designed by feedback using the output changes according to the body-load fluctuation. Last, power circuit for efficient control the heat generated from the hardware was proposed.

필터뱅크기법에 기반한 전력신호 플리커 검출 (Power Signal Flicker Detection Based on Filter Bank Technique)

  • 최훈;배현덕
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.179-193
    • /
    • 2016
  • In power quality monitoring, voltage fluctuation is one of the power quality problems, which cause light flickers. To determine the flicker severity, the flicker meter concept was developed in an IEC 61000-4-15 standard. Generally, voltage fluctuations are described as an amplitude modulation(AM). The flicker meter of IEC 61000-4-15 as an international standard for flicker measurement recommends square demodulation method to detect flicker signals from voltage fluctuation signals. This paper suggests a new effective method using filter bank to detect and estimate flicker signals, which do not need square demodulation. For the accurate detection of flicker signals, the filter bank is designed with a full consideration of the spectrum characteristics of voltage fluctuation signals described as AM. The frequency and magnitude of the detected flicker signals are estimated using recursive method. Computer simulations were performed on synthesized signals to prove validity of the proposed method.

선회류 유입에 대한 원추디퓨저의 정압회복 특성 (The characteristics of static pressure recovery in a conical diffuser with a swirling flow)

  • 정효민;정한식
    • 대한기계학회논문집B
    • /
    • 제22권7호
    • /
    • pp.937-945
    • /
    • 1998
  • The purpose of this paper is to investigate the relationship between pressure recovery and turbulent characteristic value of velocity and pressure, in the case where a swirling flow streams into a conical diffuser. The results of both measurements of the wall pressure fluctuation and velocity fluctuation revealed them to role the large part of the total pressure loss of the flow. The cause of the fluctuation of flow was showed to be the flow separation at the inlet of diffuser at low intensity of swirl, but the flow of diffuser center was instable at high intensity of swirl. The static pressure recovery depends strongly on the magnitude of the turbulent energy in the diffuser, and that this magnitude of the turbulent energy varies as the intensity of swirl at the diffuser inlet.

밀폐된 동시 회전 디스크 내의 주기적 유동 교란의 분포 (Distributions of oscillating flow fluctuation in the flow between corotating disks confined)

  • 공대위;주원구
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.392-395
    • /
    • 2006
  • The configuration of coaxial co-rotating contained in shroud provides a useful model for investigating the characteristics of flow in the HDD. Reynolds number is defined as $Re_R={\Omega}{R_o}^2/{\upsilon},\;Re_H={\Omega}R_oH/{\upsilon}$ in present study. An experimental investigation was performed for turbulence profiles and PSD distribution and vortices frequency behavior for various range of $Re_R=2.43{\times}10^4{\sim}3.61{\times}10^5$. A laser Doppler anemometry (LDA) is used to obtain the velocity field of unobstructed co-rotating disks flow. Airflow pattern visualization between inner and outer region was compared with turbulence profiles measured from LDA. Outer detached shear layer and dead-zone without oscillating velocity fluctuation to circumferential mean were quantitively traced.

  • PDF

연소실 압력 변동이 버너내부의 당량비 변조에 미치는 영향 (An Effect of Pressure Fluctuations of a Combustion Chamber on the Modulation of Equivalence Ratio in the Channel of the Burner)

  • 홍정구;오광철;신현동
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.202-207
    • /
    • 2007
  • In order to understand the phenomena of combustion instability, an experimental study was conducted at the moderate pressure and ambient temperature conditions. The flame behavior and the pressure fluctuations were measured in a dump combustor. Various types of combustion modes occurred in accordance with the equivalence ratio and the fuel supplying conditions. The fluctuation of pressure, heat release and equivalence ratio were measured by piezoelectric pressure sensor, high speed Intensified Charge Coupled Device (HICCD) camera and gas chromatography respectively. Two representative modes were self-excited pressure oscillations at the resonance of combustion chamber (200Hz) and instabilities related to the modulated fuel flow rate through the fuel holes (10Hz). It is found that, especially in an unchoked fuel flow condition, the modulation of the fuel flow rate affects the characteristics of flame behavior and pressure fluctuations in a lean premixed flame.

태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템 (Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation)

  • 김홍성;최규하;유권종
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

개략견적 기법 개발을 위한 신한옥 특성 분석 (Characteristics of Modernized Hanok for development Estimate system.)

  • 김효선;정영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.124-125
    • /
    • 2013
  • The purpose of this research is to propose an approximate estimation system for Modernized Hanok. Mock-up (Jisinjae) site data has been collected and analysed to characterize the modernized Hanok and to examine the range of cost fluctuation rate with each work items. As a result, number of floor, area (㎥), shape, methods and materials were considered as key factors for price change on the total construction cost. Furthermore, wood structure (34%) and roof (17%) account for major cost percentage. The cost fluctuation rate of two factors were -3.3%~+5.6% (wood structure) and -4.1%~+4.2% (roof). For further research, existing method will be analysed in order to developing the Hanok estimation system. And the cost fluctuation rate of every work items will be continually evaluated.

  • PDF

수소압축기 스너버 관로 내부의 맥동파 특성에 관한 연구 (A Study on Gas Pressure Fluctuation Characteristics inside Pipe Line Passing Through a Snubber at Hydrogen Compressor)

  • 심규진;이중섭;악바르 완다 알리;정한식;정효민
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.165-171
    • /
    • 2006
  • An experiment to observe reduction of pressure fluctuation in the compressing system utilizing snubber has done. The experiment measured pressure at inlet and outlet of snubber. It used an air compressor as a model of hydrogen one. Snubber with buffer and snubber without buffer were used to get comprehensive comparison between both of that snubber. An analysis by using Fast Fourier Transform (FFT) method was conducted to verify working pressure frequency. With this method pure signal of static pressure was filtered from noisy signal. The experiment was run for several speeds of piston movement. It was controlled by adjustable frequency regulator that controled rotation of actuator motor. This was connected to the piston-reciprocating compressor with V-belt. From result obtained, the fluctuation was increasing proportionally when frequency of driver motor was increased.

  • PDF