• Title/Summary/Keyword: Flowmeter test

Search Result 72, Processing Time 0.033 seconds

Custody Transfer Hydrocarbon Flow Measurement with Multi-path Ultrasonic Flow Measurement (다회선 초음파 유량계를 이용한 거래용 오일유량 측정)

  • Hwang, Shang-Yoon;Lee, Ho-June;Park, Ki-Hwan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.149-153
    • /
    • 2003
  • As the fastest growing flowmeter technology, multi-path ultrasonic flow-meters are gaining wider range in petroleum industry for liquid hydrocarbon custody transfer measurement. This paper describes the mult-path ultrasonic flowmeter, URO-Ex1000 the requirements necessary to prove and test in Korea & China. URO-Ex1000 haver a good results with accuracy range, but a little exceed with repeatability.

  • PDF

THE RELIABILITY OF LASER DOPPLER FLOWMETER IN PULP VITALITY TEST OF TEETH (치수생활력 검사 방법으로서 laser Doppler flowmeter의 신뢰도)

  • Nam, Dong-Woo;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.683-690
    • /
    • 1998
  • The purpose of this study was to evaluate the reliablity of laser Doppler flowmeter on the permanent maxillary central incisors with open apex. Laser Doppler flowmeter and electric pulp tests were done in 35 elementary students aged between 8 and 9 years and 35 females and males aged between 23 and 24 years. Teeth with open apex were confined to root developmental stage 5 and 6 by Moorrees classification. The threshold of electric pulp tests was decided the time of tingling sensation. More than three different electric pulp tests applied on every teeth with more than 3 minutes interval between each teeth due to the false response. Laser Doppler flowmeter test stablilzation and observation stages took more than 5 minutes each LDF values and electric pulp test thresholds were analyzed with student t-test. The results were as follows: 1. The electric pulp test threshold on teeth with immature and mature roots showed 28.4% and 100% response respectively, and the the LDF values on teeth with immature and mature roots showed 100% response. 2. The EPT thresholds on teeth with immature roots were larger than thresholds on teeth with mature roots(p<0.01). 3. No significant differences were found in the LDF values on teeth with immature and mature roots.

  • PDF

A Study of the Precise Flow Measurement using Coriolis flowmeter (코리올리 유량계를 이용한 정밀유량측정에 관한 연구)

  • Kim, In-Tae;Cho, Dae-Kee;Jeong, Min-Je;Lee, Jae-Won;Seo, Hyuk;Yu, Myoung-Jong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.61-64
    • /
    • 2008
  • For the performance evaluation of liquid mono-propellant thruster, Vacuum Hot-fire test is necessarily required. An accurate flow measurement is one of the key parameters to the successful T&E program. This paper describes the characteristics of the coriolis flowmeter, explains the cold-flow test using simulant propellant (DIW), and presents the test results. Finally, the cold test results have been verified in comparison with the hot-fire test data.

  • PDF

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter (코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구)

  • Lim, Ki-Won;Lee, Woan-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.

시추공 지구물리 방법에 의한 결정질암의 대수 특성 정밀

  • Kim Yeong-Hwa;Gong Nam-Yeong;Lee Seong-Jin
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.92-96
    • /
    • 2006
  • Borehole geophysical techniques were adopted for characterizing aquifer properties of crystalline rock formation in Bongmyong borehole test site, Kangwon National University. Specific fractures and/or fracture zones accompanying groundwater flow were delineated well by high resolution flowmeter and dilution measurements, and could be confirmed fromconventional well log methods. These geophysical techniques have been proved to be the most effective in aquifer characterization in crystalline rock formation.

  • PDF

RELATIONSHIP BETWEEN LASER DOPPLER FLOWMETER OUTPUT AND STAGE OF ROOT DEVELOPMENT (치근 발육정도와 Laser Doppler Flowmeter 측정치의 상호 관련성)

  • Su, Wan-Jong;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.437-445
    • /
    • 1999
  • The purpose of this study was to evaluate the changes of laser doppler flowmeter output associated with stage of root development. Laser Doppler Flowmeter was done in 40 elementary students aged between 7 and 8 years and in 20 adults aged between 23 and 24 years. Among 40 elementary students, 20 had apical foramens with $1{\sim}2mm$ diameters and another 20 had ones with larger diameters than 2mm. The LDF values were analyzed with ANOVA and paired t-test. The results were as follows. 1. Immature root apecies group had a higher tendency than mature root apecies group in LDF values, but there was no statistical significance (p>0.05). 2. There was no statistical significance in LDF values comparing groups with immature root apecies (p>0.05). 3. There were no significant differences between right and left central incisors in LDF values (p>0.05).

  • PDF

An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters (터빈형과 기어모터형 유량계의 동특성 검토)

  • 예용택
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF

Characteristics of Uni-directional Diverter for Gravimetric Calibration Facility (액체용 중량식 유량계 교정장치의 일방향 Diverter 특성연구)

  • Nam, Ki Han;Park, Jong Ho;Kim, Hong Jip
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.59-64
    • /
    • 2017
  • Diverter is an essential element in gravimetric calibration method of flowmeter. Error of diverter are influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. That's why, time detection position of diverter is tuned through repetitive test for minimizing error of diverter. Further the diverter must be compared with the other institutions test since the influence on the accuracy of the flow meter used in the test. In this paper, errors (flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location) of diverter are decreased by produced uni-direction diverter and error of gravimetric calibration system is decreased. Uni-direction diverter is calibrated by gravimetric calibration system with precision flowmeter, the flowmeter is calibrated by pipe prover and other institutions and uni-direction diverter is evaluated. Uni-direction diverter is not influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. As a result, Uni-direction diverter can calibrate in wider scope since increasing ratio of maximum and minimum flow rate of uni-direction diverter.

A Study on the Reverse Engineering and Performance Test in the Development of Screw Flowmeter (스크류유량계 개발에서의 역공학 및 성능평가에 관한 연구)

  • Hwang, Jong-Dae;Jung, Jong-Yoon;Lee, Sang-Ryul;Jung, Yoon-Gyo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.2
    • /
    • pp.24-30
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flowmeter.

  • PDF