• Title/Summary/Keyword: Flowmeter

Search Result 262, Processing Time 0.026 seconds

Study on the Characteristics of Scroll type Stirling Engine Receiver for Solar Thermal Power (태양열 발전용 스크롤 방식 스터링엔진 흡수기 특성 연구)

  • Seo, Ho-Young;Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.62-67
    • /
    • 2009
  • This paper describes the characteristics of scroll type stirling engine receiver. Scroll type stirling engine operated scroll compressor and expander instead of piston. Pass dimension of the receiver was $14(W){\times}14(H)$ mm and total pass length was 5,049 mm. External dimension of the receiver was $300{\times}300mm$. The experimental facility consisted of parabolic dish concentrator, compressor to supply air, triplex air filter, and flowmeter. In this study, basic experimental conditions were set at a inlet pressure of 5 bar and volume flow rate of $25m^3/hr$. As a result, air temperature in receiver at each measuring position of point 1, 2, 3 were $241^{\circ}C$, $465^{\circ}C$, and $542^{\circ}C$ respectively at inlet pressure of 5.5 bar and volume flow rate of $24.6m^3/hr$. As DNI increasing, heat transfer coefficient of the receiver changed from $695W/m^2K$ to $827W/m^2K$. Average heat transfer coefficient of receiver in the experiment was $798W/m^2K$. In addition, receiver efficiency became about 83%.

  • PDF

Estimation of Ventricular Assist Device Outflow with the Pressures in Air Pressure Line (공압식 박동형 심실보조장치의 공압관 내 압력 측정을 통한 박출량 추정)

  • Kim, Young Il;Her, Keun;Kang, Seong Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.119-124
    • /
    • 2014
  • A Ventricular assist device (VAD) is one of the most efficient treatments to raise the survivability of the end stage heart failure patient. However, some of LVAD patients have died for the failures and improper control of LVAD. To detect critical dangers in LVAD, the monitoring methods of LVAD outflow have been requested, because it can be affected by patient's hemodynamic states and abnormal conditions of LVAD. In the case of an external pulsatile LVAD, the air movement through the air line can be used to estimate LVAD outflow. In this study, the air movement in the air-line of the extracorporeal pulsatile LVAD was measured with a differential pressure sensor between different points. The precise estimation of air movement could be achieved by additional measurement of air pressure. In a series of in-vitro experiments, the LVAD outflow were changed according to the afterload of LVAD and the differential pressure of LVAD didn't have close correlation with the LVAD outflow that were measured with an ultrasonic flowmeter at the same time. However, new precise estimation with the data from differential pressure and one point pressure in the air-line showed higher correlations with LVAD outflow.

Investigation for Streamflow Measurement of Small Stream using Dilution Discharge Method during Low Flow Season (갈수기 소하천에서 희석유량법을 이용한 유량측정의 적용성 검토)

  • Kim, Gee Hyeong;Kim, Jeongkon;Lee, Sanguk
    • Journal of Wetlands Research
    • /
    • v.8 no.4
    • /
    • pp.59-67
    • /
    • 2006
  • In this study, dilution discharge method to measure streamflow using water quality data at small streams during low flow season was applied and compared with the conventional method using flowmeter combined with cross-sectional measurement. Streamflow were measured using both methods in Dal-cheon around Naesok Wastewater Treatment Plant located in Boeun, Chugbuk. This stream is reported to suffer from excessive algal growth in spring. An average flowrate difference of $0.004m^3/sec$ was obtained between the two methods. Once further tested for various conditions, the simple water quality method suggested in this study can be used effectively to estimate stream flowrates during low flow seasons where no measuring facilities such as weirs and flowmeters are not available or water depths are too small to measure flow velocities and exact cross-sections.

  • PDF

Improving Flow Property of AlSi10Mg Powder for Additive Manufacturing via Surface Treatment using Methyltrichlorosilane (Methyltrichlorosilane 표면 처리를 통한 적층 제조용 AlSi10Mg 분말의 유동 특성 향상 공정 연구)

  • Park, Sang Cheol;Kim, In Yeong;Kim, Young Il;Kim, Dae-Kyeom;Lee, Kee-Ahn;Oh, Soong Ju;Lee, Bin
    • Journal of Powder Materials
    • /
    • v.29 no.5
    • /
    • pp.363-369
    • /
    • 2022
  • AlSi10Mg alloys are being actively studied through additive manufacturing for application in the automobile and aerospace industries because of their excellent mechanical properties. To obtain a consistently high quality product through additive manufacturing, studying the flowability and spreadability of the metal powder is necessary. AlSi10Mg powder easily forms an oxide film on the powder surface and has hydrophilic properties, making it vulnerable to moisture. Therefore, in this study, AlSi10Mg powder was hydrophobically modified through silane surface treatment to improve the flowability and spreadability by reducing the effects of moisture. The improved flowability according to the number of silane surface treatments was confirmed using a Carney flowmeter. In addition, to confirm the effects of improved spreadability, the powder prior to surface treatment and that subjected to surface treatment four times were measured and compared using s self-designed recoating tester. The results of this study confirmed the improved flowability and spreadability based on the modified metal powder from hydrophilic to hydrophobic for obtaining a high-quality additive manufacturing product.

Aerosol Sampling with Two Stage Filter Sampler and Seasonal Variation of Metal Components in the Atmosphere (이단 필터 샘플러에 의한 대기 부유분진의 포집 및 금속 성분의 계절별 거동에 관한 연구)

  • Lee, Yong-Keun;Kim, Nam-Hoon;Myung, No-Seung;Whang, Kyu-Ja
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.20-27
    • /
    • 1988
  • A simple two stage aerosol filter sampler which allows simultaneous and fractional collection of two different-size particles, coarse and fine, was constructed and applied to the collection of Seoul atmospheric particulate for inorganic analysis. The sampler consist of two 47-mm diameter filter holder, a pneumatic pump, and a flowmeter. Filtering rate normally runs around 20$\ell$/min for 8 hrs. Using the sampler, a series of seasonal aerosol samples were collected from June 1986 to March 1988 at Yonsei University campus, Seoul and subsequently analysed for ten environmentally important metals using an atomic absorption spectrometer and an inductively coupled plasma emission spectrometer. The analysed metals are Al, Cd, Cr, Cu, Fe, Mn, Ni, Pb, V, and Zn. The analytical results showed the following order of metal abundance; Al > Fe > Zn > Pb > Mn > Cu > V > Ni > Cr > Cd. Based upon their size distribution pattern, the analyzed matals could be clasified into two groups, those present primarily in coarse particle and those in fine particle. Fe, Al, Mn, V, and Cr belong to the former group while the rest to the latter. Most metal concentration were highest in spring or winter, and lowest in autumn. Statistical analysis showed strong correlations between Al and Fe, Pb and Zn, and Cu and Mn.

  • PDF

Performance Comparison of Neural Network Models for the Estimation of Instantaneous and Accumulated Powder Exhausts of a Bulk Trailer (벌크 트레일러의 순간 및 누적 분말 배출량 추정을 위한 신경망 모델 성능 비교)

  • Chang June Lee;Jung Keun Lee
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.174-179
    • /
    • 2023
  • Bulk trailers, used for the transportation of powdered materials, such as cement and fly ash, are crucial in the construction industry. The speedy exhaustion of powdered materials stored in the tank of bulk trailers is relevant to improving transportation efficiency and reducing transportation costs. The exhaust time can be reduced by developing an automatic control system to replace the manual exhaust operation. The instantaneous or accumulated exhausts of powdered materials must be measured for automatic control of the bulk trailer exhaust system. Accordingly, we previously proposed a recurrent neural network (RNN) model that estimated the instantaneous exhaust based on low-cost pressure sensor signals without an expensive flowmeter for powders. Although our previous study utilized only an RNN model, models such as multilayer perceptron (MLP) and convolutional neural network (CNN) are also widely utilized for time-series estimation. This study compares the performance of three neural network models (MLP, CNN, and RNN) in estimating instantaneous and accumulated exhausts. In terms of the instantaneous exhaust estimation, the difference in the performance of neural network models was insignificant (that is, 8.64, 8.62, and 8.56% for the MLP, CNN, and RNN, respectively, in terms of the normalized root mean squared error). However, in the case of the accumulated exhaust, the performance was excellent in the order of CNN (1.67%), MLP (2.03%), and RNN (2.20%).

Concentration of water flow to improve flowmeter accuracy and International Performance Standards (Q2/Q1) 1.6multiple Correlation of Reliability Securing (유량계측 정확도 향상을 위한 유로집중과 국제성능기준 전이유량비(Q2/Q1)1.6배수 신뢰성 확보의 상관관계)

  • Seo, Man Je
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.237-237
    • /
    • 2020
  • 수도계량기(이하 "수량계")는 액체용 적산부피계로 물 사용량을 적산 계량하기 위한 기계기구 또는 장치이며 수량계 검정기준에 의해 검사기준 합격제품을 사용하서 수도요금을 징수합니다. 사실상 국내계량에 관한 법률에 의거하여 전이유량비가 6.3배수(2014년) > 4.0배수(2016년) > 1.6배수(2017년)로 점점 향상되며 2017년 기준으로 국제법정계량기구(OIML)의 성능과 같은 1.6배수까지 향상되어 국내의 수량계 기술기준이 많은 부분 향상되었습니다. 그러나 국제법정계량기구(OIML)는 현재 1.6배수의 80배수까지 검사기준에 합격에 반하여 현제 국내의 검사기준은 1.6배수의 100배수까지만 합격기준을 가지고 있습니다. 이러한 기준은 점차 발전해가고 있는 후발국가에 속하는 자국의 검사기준이 너무 갑작스럽게 국제법정계량기구(OIML)의 기준보다 높은 검사기준을 시행하며 많은 문제가 발생한 것 같습니다. 위와 같은 문제를 해결하기 위하여 여러 복합적인 부품으로 이루어진 수량계의 유량 및 유속에 영향력이 있다고 보여지는 특정 부품 혹은 부위의 개선 및 개발로 해결할 수 있지 않을까 하는 의구심에 연구를 시작되었습니다. 유량 및 유속에 영향을 끼치는 유입부의 스트레이너, 내부 임펠러의 변경으로 성능검사에서 영향을 끼치는지를 유체역학 및 유동해석 등을 통하여 테스트 후 각각 단계 및 상황별 목업금형을 제작하여 현재 국내검사기준으로 진행되는 성능테스트인 기차테스트를 진행하였습니다. 먼저 수량계의 특성상 수량계 내부의 유량을 유체역학 및 유동해석으로 정확히 뽑아내는 것이 불가능하여 유입부 유출부의 유량의 흐름을 기준으로 유체역학 및 유동해석을 진행하였습니다. 테스트 후 그 결과 값으로 유입부의 스트레이너의 삽입 각도를 0°, 90°, 135°, 180°, 270°로 각각 제작하여 테스트를 진행하였으며, 내부 임펠러는 straight, SR, SL, SL R70, SL R60, R75, SR R65 형상으로 각각 제작하여 테스트를 진행하였습니다. 전반적으로 기존의 수량계보다 높은 성능을 보여주었으며, 특정 스트레이너의 삽입각도 및 임펠러의 형상에서는 기존보다 훨씬 유수율이 절감되는 결과값이 나왔습니다. 그로 인해 검사기준에 쉽게 부합할 수 있으며 물 사용량을 보다 정확히 계측하여 정확한 수도요금을 부과하여 국세 낭비로 인한 경제적 손실을 감소할 수 있을 것 같습니다.

  • PDF

A Study on the Application of Gastrodiae rhizoma for Food Stuffs - Effects of Gastrodiae rhizoma on the Regional Cerebral Blood Flow and Blood Pressure - (천마의 식품학적 활용을 위한 기초 연구 - 포제천마 열수 추출물이 국소 뇌혈류량과 혈압에 미치는 영향 -)

  • Park, Sung-Hye;Cho, Choa-Hyoung;Ahn, Byung-Yong
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.17 no.4
    • /
    • pp.554-562
    • /
    • 2007
  • This study was performed to provide basic data for predicting the usefulness of Gastrodiae rhizoma as a materials for functional foods. Changes in regional cerebral blood flow(rCBF) and blood pressure(BP) were measured in rats, following the intravenous injection of processed Gastrodiae rhizoma water extract. In its processing, we used rice water, Sderotium Poriae Cocos and Radix Ligustici Chuanxiaong. The rCBF and BP measurements were continually monitored by a laser-doppler flowmeter and a pressure transducer in the anesthetized adult Sprague-Dawley rats for approximately about two to two and a half hours, through a data acquisition system composed of a MacLab and Macintosh computer. The results of the experiment are as follows: the processed Gastrodiae rhizoma significantly increased changes in rCBF in the rats. The rCBF with processed Gastrodiae rhizoma did not change by pretreatment with propranolol, atropin, methylene blue, and indomethacin. But the rCBF of the processed Gastrodiae rhizoma was increased by pretreatment with L-NNA. The processed Gastrodiae rhizoma significantly decreased the changes in BP. However, BP with the processed Gastrodiae rhizoma did not change by pretreatment with propranolol, atropin, methylene blue and indomethacin. On the other hand, BP decreased with the processed Gastrodiae rhizoma pretreatment with L-NNA. These results indicate that processed Gastrodiae rhizoma might increase the rCBF and the BP which are related to nitric oxide synthesis. Also these results indicate that the used of processed Gastrodiae rhizoma in safe, as well as clinically applicable in diet therapy for cerebral related disease and hypertension.

  • PDF

Intraoperative Measurement and Analysis of Coronary Artery Bypass Graft Flow (수술중 측정한 관상동맥 우회도관 혈류량의 분석)

  • Park, Kye-Hyun;Chae, Hurn;Yun, Yang-Ku;Lee, Jae-Woong;Kim, Kwhan-Mien;Jun, Tae-Gook;Kim, Jhin-Gook;Shim, Young-Mog;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.760-769
    • /
    • 1997
  • This study aimed to determine factors that influence blood flow through coronary bypass grafts and to analyze relationship between the graft flow and postoperative outcome. Blood flow through 146 bypass grafts(GBF) was measured with transit-time ultrasound flowmeter during coronary artery bypass grafting operations in 50 patients. Single and multiple regression analyses were done for relationships between the GBF and four variables: internal diameter of recipient coronary artery, myocardial value of bypassed branch(es), type of graft, and finding of preoperative myocardial perfusion scan. The relationship between GBF and postoperative scan finding was also analyzed. 1. The mean GBF was significantly higher in sequential grafts than in single vein grafts or in internal thoracic artery grafts(61.5 vs. 46.9 and 42.5 ml/min). 2. Myocardial value and recipient artery diameter were found to be the factors determining GBF. There was no correlation between GHF and presence of perfusion defect in the preoperative scan. 3. Myocardial value was found to be more important than recipient artery diameter in determinintg GBF. 4. Reversible perfusion defects were more frequently found in the areas upplied by grafts with low GBP. But this fact had only mild statistical significance. These results suggest that blood flow through a bypass graft is more determined by the size of its supplyinf: myocardium than by the size of recipient artery. So, we can expect effective improvement in myocardial flow reserve after grafting of small(1~1.5mm) coronary arteries, if they supply substantial area of myocardium.

  • PDF

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.