• Title/Summary/Keyword: Flowmeter

Search Result 262, Processing Time 0.026 seconds

A Study on Error Characteristic of Flow Disturbance and Velocity for Electromagnetic and Ultrasonic Flowmeters (유속과 유동교란인자에 의한 전자식 및 초음파식 유량계의 오차특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the effect of flow disturbance such as contraction, expansion pipe and velocity deviation from low velocity of $0.1\;^m/s$ to $2.5\;^m/s$ on the error characteristics of the flowmeter was studied. Flow experiments using flowmeter calibration facility of K-water were undertaken for the cases of ultrasonic flowmeter based on transit-time method and electromagnetic flowmeter. Experimental results are presented that measurement error of expansion pipe are larger than contraction pipe. It is shown that the minimum straight length were required to remain of ${\pm}0.5%$ error for electromagnetic flowmeter and ${\pm}2.0%$ error for ultrasonic flowmeter.

A Study on Error Characteristics of Large Size Electromagnetic Flowmeter in the Range of Low Velocity (저유속 영역에서 대구경 전자기유량계의 오차특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • The large size electromagnetic flowmeter was tested to investigate the variation of its error characteristics in the range of low velocity under 0.6 m/s using flowmeter calibration system. For the two case of valve opening rate 100 % and 50 %, these tests were undertaken three times each for twelve velocity condition from $0.05\;^m/s\;to\;0.6\;^m/s$ with increment of $0.05\;^m/s$. It is shown that error characteristic of electromagnetic flowmeter was stabilized within ${\pm}0.4%$ of rate both higher than $0.25^m/s$ of velocity condition and 50 % of valve opening position. But, measurement deviation of flowmeter for ${\Phi}400mm\;and\;{\Phi}600mm$ was out of expected deviation range. It is necessary to correction with calibration. In conclusion, error characteristic of electromagnetic flowmeter wasn't changed proportion to its size.

Installation effects on the characteristics of multi-path ultrasonic flowmeter (배관 형상이 다회선 초음파 유량계의 특성에 미치는 영향)

  • Park, K. A.;Choi, Y. M.;Choi, H. M.;Yoon, B. R.;Hwang, K. B.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.114-117
    • /
    • 1999
  • Five-path ultrasonic flowmeters (200 and 300 mm diameters) were tested to obtain it's characteristics in a water flow standard system. A five-path ultrasonic flowmeter was installed after various pipe fittings (elbow, valve, tee) or a pump. The distance between flow disturbance source and a flowmeter was main experimental parameter. Without a flow conditioner, a five-path ultrasonic flowmeter shows good characteristics as the distance between flow disturbance source and a flowmeter is longer than 10 diameter of a flowmeter.

  • PDF

Numerical analysis of the venturi flowmeter in the liquid lead-bismuth eutectic circuit after long-term operation

  • Zhichao Zhang;Rafael Macian-Juan;Xiang Wang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.1081-1090
    • /
    • 2024
  • The liquid Lead-bismuth eutectic is used as the coolant for Gen-IV reactor concepts. However, due to its strong corrosive and high operating temperature, it is difficult to accurately measure the flow rate in long-term operating conditions. Venturi flowmeter is a simple structured flowmeter, which plays a very important role in the flow measurement of high-temperature liquid metals, especially since the existing flowmeters are difficult to be competent. It has the advantages of easy maintenance and stable operation. Therefore, it is necessary to study the operating conditions of the venturi flowmeter under high-temperature conditions. This work performs a series of simulations of the fluid-solid interaction between the flow liquid metal and venturi flowmeter with COMSOL software, including the dimensional sensitivity analysis of the venturi flowmeter to explore the most suitable structure and parameters for liquid heavy metal, the sensitivity analysis of the geometric parameters of the venturi tube on the varying conditions. It shows that when the contraction angle of the venturi flowmeter is 33°, the diffusion angle is 13°, the diameter of the throat is 8 mm, and the temperature of the lead-bismuth eutectic is 733.15 K, it is most suitable for the measurement in the lead-bismuth circuit.

Development and Application of an Ultrasonic Gas Flowmeter (초음파 가스 유량계 개발과 활용)

  • Hwang, Won-Ho;Park, Sang-Gug;Jeong, Hee-Don;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.246-253
    • /
    • 2002
  • This paper describes the development and the field application of the ultrasonic gas flowmeter for accurate measurement of the volumetric flow rate of gases in a harsh environmental conditions in iron & steel making company. This ultrasonic flowmeter is especially suited for measuring LDG, COG, BFG gases produced in iron & steel making process. This is a transit time type ultrasonic flowmeter. We have developed the transmitting & receiving algorithm of ultrasonic wave and the ultrasonic signal processing algorithm to develope a transit time type ultrasonic flowmeter. We have evaluated the performance of ultrasonic flowmeter by the calibration system with Venturi type standard flowmeter. We has confirmed its reliability by extensive field tests for a year in POSCO, iron & steel making company. Now we have developed the commercial model of ultrasonic flowmeter and applied to the POSCO gas line.

Wireless Automatic Flowmeter Using PICBASIC (PICBASIC을 이용한 무선자동 유량시스템)

  • 박정희
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.2
    • /
    • pp.229-234
    • /
    • 2001
  • The flowmeter is being widely used from water flowmeter for homeuse to many other applications for industry such as petrochemistry. In particular, a wireless automatic flowmeter is highly in demand. This paper suggests a gearwheel wireless automatic flowmeter using PICBASIC which can be simply implemented for manufacturing. It is confirmed by experiment that the automatic flowmeter using by a wireless chip works well in a local area within 300 meters.

  • PDF

Installation Effects on the Characteristics of Multi-path Ultrasonic Flowmeter with Valve (밸브후단에서의 다회선 초음파 유량계의 특성변화)

  • Hwang, S. Y.;Seo, K. H.;Kim, B. C.;Kim, K. S.;Tyan, H. S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.65-74
    • /
    • 2000
  • A five path ultrasonic and/or magnetic flowmeter were installed after valve. Five path ultrasonic flowmeter were tested to obtain it's performance in a water flow standard system and magnetic flowmeter. It's varied with straight pipe length(nD), install direction and valve position. All the results are summerized. The multi-path flowmeters(MUF) showed up to $\pm0.5{\%}$ at a 2, 4, 8, 15D spacing : the MUF was significantly better than magnetic flowmeter at disturbed flow conditions.

  • PDF

A Real-Time Measurement of Slug Flow Using Electromagnetic Flowmeter with High frequency Triangular Excitation (고주파 삼각파 여자법을 사용한 실시간 슬러그 유동 측정용 전자기유량계)

  • Ahn, Yeh-Chan;Cha, Jae-Eun;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1570-1577
    • /
    • 2002
  • In order to investigate the characteristics of two-phase slug flow, an electromagnetic flowmeter with 240Hz triangular AC excitation was designed and manufactured. The signals and noise from the flowmeter were obtained, and analyzed in comparison with the observations with a high speed CCD camera. The uncertainty of the flowmeter under single-phase flow was $\pm$ 2.24% in real-time. For two-phase slug flow, electromagnetic flowmeter provided real-time simultaneous measurements of the mean film velocity around Taylor bubble and the relative location and the length of the bubble. Besides, it is an easier and cheaper method for measuring mean film velocity than others such as photochromic dye activation method or particle image velocimetry.

Study on the Development of Multi-Path Ultrasonic Gas Flowmeter (전달 시간차 방식 다회선 초음파 가스 유량계 개발)

  • 황원호;박상국;이치환;장경영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1046-1050
    • /
    • 2003
  • In this paper, we describe study on the development or multi-path ultrasonic gas flowmeter using a transit time method. This system includes 5 pairs of ultrasonic transducers. ultrasonic signal processing unit using switch matrix method, computation algorithm of gas flow rate, spool piece type multi-path pipe unit. We have developed enhanced type of main ultrasonic signal processing unit using switch matrix method fer multi-path ultrasonic gas flowmeter. Also, we have developed the new transmitting & receiving method of ultrasonic waves and the new signal processing algorithm for the computation of ultrasonic transit time from received ultrasonic waves. In this study, we have designed more compact signal processing unit compared with the conventional hardware system of multi-path ultrasonic gas flowmeter. We have confirmed its reliability for multi-path ultrasonic gas flowmeter through the laboratory test using calibration system. In the future. we will perform the field test for the developed system in the POSCO gas line.

  • PDF

Study on the development of ultrasonic gas flowmeter (초음파 가스 유량계 개발 연구)

  • Hwang, Won-Ho;Park, Sang-Gug;Yang, Kyu-Hong;Jhang, Kyung-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.76-81
    • /
    • 2001
  • Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG, COG, BFG gases produced in iron & steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has already well been proven by extensive field tests for several months in POSCO, iron & steel making company.

  • PDF